Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Micro-Pulse DIAL for Atmospheric Water Vapor Profiling (Phase I Final Report)

Water vapor plays a key role in Earth’s climate and weather patterns. Accurate, high resolution measurements of the water vapor vertical profiles in a region have been found to significantly improve the numerical weather prediction models’ short-term forecasts, precipitation forecasts, as well as severe weather forecasts. However, current measurement techniques provide very coarse resolution in space, time, and/or altitude. A network of continuously sampling water vapor profilers would greatly expand the scientific knowledge of the atmosphere and serve as a valuable input into numerical weather models. This would be of interest not only to the Department of Energy’s Environmental Sciences Division but to other institutions such as the National Weather Service, the National Center for Atmospheric Research, the Federal Emergency Management Agency, and the military.

54 ENVIRONMENTAL SCIENCES↗

Preliminary investigation of pilot scanning techniques of dial pointing instruments

Two pilots' methods of looking at instruments with needle pointers in a fixed base helicopter simulation were observed. A total of 45 runs were analyzed for each pilot. The data indicated that two apparently different techniques were being used; one looking at the needle point, the other looking at a fixed spot on the instrument and reading the needle direction parafoveally. The latter technique is found to be somewhat faster with both pilots accomplishing the flying task.

Harris, R. L., Sr.↗

Assessment of relative error sources in IR DIAL measurement accuracy

An assessment is made of the role the various error sources play in limiting the accuracy of infrared differential absorption lidar measurements used for the remote sensing of atmospheric species. An overview is presented of the relative contribution of each error source including the inadequate knowledge of the absorption coefficient, differential spectral reflectance, and background interference as well as measurement errors arising from signal fluctuations.

Menyuk, N.↗

High Spectral Purity, Narrow Linewidth Laser Transmitter for Dial Measurements

A laser transmission with very high degree of spectral purity was described. Amplified Spontaneous Emission (ASE) dependence on the oscillator energy and the detuning away from the gain curve center are demonstrated. The effects of both finite laser linewidth and spectral purity on humidity measurements are experimentally demonstrated.

Singh, U. N.↗

Multifrequency dial sensing of the atmospheric gaseous constituents using the first and second harmonics of a tunable CO2 laser radiation

The results of field measurements of concentration of some gaseous components of the atmosphere along the paths, in Sofia, Bulgaria, using a gas analyzer based on the use of a CO2 laser radiation frequency-doubled with ZnGeP2 monocrystals are presented. The gas analyzer is a traditional long path absorption meter. Radiation from the tunable CO2 laser of low pressure and from an additional He-Ne laser is directed to a colliminating hundredfold Gregori telescope with a 300 mm diameter of the principal mirror. The dimensions of the mirrors of a retroreflector 500 x 500 mm and a receiving telescope allow one to totally intercept the beam passed through the atmospheric layer under study and back.

Zuev, V. E.↗

CO2 DIAL measurements of water vapor

CO2 lidars have heretofore been used to measure water vapor concentrations primarily using the 10R(20) line at 10.247 microns, which has a strong overlap with a water vapor absorption line. This paper discusses the use of that line as well as other CO2 laser lines for which the absorption coefficients are weaker. The literature on measurement of water vapor absorption coefficients using CO2 lasers is reviewed, and the results from four laboratories are shown to be generally consistent with each other after they are normalized to the same partial pressure, temperature, and ethylene absorption coefficent for the 10P(14) CO2 laser line; however, the agreement with the Air Force Geophysics Laboratory's HITRAN and FASCOD 2 spectral data tapes is not good either for the water vapor absorption lines or for the water vapor continuum. Demonstration measurements of atmospheric water vapor have been conducted using the Mobile Atmospheric Pollutant Mapping System, a dual CO2 lidar system using heterodyne detection. Results are discussed for measurements using three sets of laser line pairs covering a wide range of water vapor partial pressures.

Grant, William B.↗

Gated photomultiplier response characterization for DIAL measurements

The characteristics of various detector responses are studied to understand the cause of various systematic biases and to minimize these undesirable effects in measurements of transient signals with large dynamic range. Signal-induced bias, gain variation, and the linearity of commonly used gated photomultipliers in the current integrating mode are quantitatively evaluated. Analysis of the results indicates that impurity ions inside the photomultiplier tubes (PMT) are the source of the signal induced bias and gain variation. Two different PMTs used in this study show significant differences in the magnitude and decay behavior of signal-induced bias. It was found that it can be minimized by using an external amplifier to reduce PMT gain, and by applying a low potential between the cathode and first dynode. The linearity of a PMT is also studied over a large dynamic range of input intensities employing a new technique which does not require an absolute calibration. The result of this study shows that the photomultiplier response is linear only for a limited input intensity range below a certain anode current.

Lee, H. Sang↗

Ground-based laser DIAL system for long-term measurements of stratospheric ozone

A ground-based differential absorption lidar system has been implemented to make long-term, precise measurements of stratospheric ozone concentration profiles from about 20 to 50 km altitude. This lidar is located at an elevation of 2300 m in the San Gabriel Mountains, Southern California, and has been in operation since January 1988. A high power (100-W) excimer laser system and a 90-cm diam telescope are used to achieve the desired performance levels. This paper describes the implementation of the system and its operation including the procedures for data analysis. Examples of ozone profiles measured, and intercomparisons with measurements made by other instruments, are presented which show that the lidar, in its present configuration, is capable of producing high quality ozone measurements from 20 km up to at least 45 km.

Mcdermid, Stuart I.↗