Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIODE LASERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Diode Laser Measurements of Concentration and Temperature in Microgravity Combustion

Diode laser absorption spectroscopy provides a direct method of determinating species concentration and local gas temperature in combustion flames. Under microgravity conditions, diode lasers are particularly suitable, given their compact size, low mass and low power requirements. The development of diode laser-based sensors for gas detection in microgravity is presented, detailing measurements of molecular oxygen. Current progress of this work and future application possibilities for these methods on the International Space Station are discussed.

Silver, Joel A.↗

Stable CW Single-Frequency Operation of Fabry-Perot Laser Diodes by Self-Injection Phase Locking

Previously, single-frequency semiconductor laser operation using fiber Bragg gratings has been achieved by two methods: 1) use of the FBG as the output coupler for an anti-reflection-coated semiconductor gain element'; 2) pulsed operation of a gain-switched Fabry-Perot laser diode with FBG-optical and RF-electrical feedback. Here, we demonstrate CW single frequency operation from a non-AR coated Fabry-Perot laser diode using only FBG optical feedback. We coupled a nominal 935 run-wavelength Fabry-Perot laser diode to an ultra narrow band (18 pm) FBG. When tuned by varying its temperature, the laser wavelength is pulled toward the centerline of the Bragg grating, and the spectrum of the laser output is seen to fall into three discrete stability regimes as measured by the side-mode suppression ratio.

Duerksen, Gary L.↗

Diode Laser Velocity Measurements by Modulated Filtered Rayleigh Scattering

The ability of solid-state lasers to be tuned in operating frequency at MHz rates by input current modulation, while maintaining a relatively narrow line-width, has made them useful for spectroscopic measurements. Their other advantages include low cost, reliability, durability, compact size, and modest power requirements, making them a good choice for a laser source in micro-gravity experiments in drop-towers and in flight. For their size, they are also very bright. In a filtered Rayleigh scattering (FRS) experiment, a diode laser can be used to scan across an atomic or molecular absorption line, generating large changes in transmission at the resonances for very small changes in frequency. The hyperfine structure components of atomic lines of alkali metal vapors are closely spaced and very strong, which makes such atomic filters excellent candidates for sensitive Doppler shift detection and therefore for high-resolution velocimetry. In the work we describe here we use a Rubidium vapor filter, and work with the strong D(sub 2) transitions at 780 nm that are conveniently accessed by near infrared diode lasers. The low power output of infrared laser diodes is their primary drawback relative to other laser systems commonly used for velocimetry. However, the capability to modulate the laser frequency rapidly and continuously helps mitigate this. Using modulation spectroscopy and a heterodyne detection scheme with a lock-in amplifier, one can extract sub-microvolt signals occurring at a specific frequency from a background that is orders of magnitude stronger. The diode laser modulation is simply achieved by adding a small current modulation to the laser bias current. It may also be swept repetitively in wavelength using an additional lower frequency current ramp.

Mach, J. J.↗

Radiation Degradation Mechanisms in Laser Diodes

Degradation mechanisms are investigated for laser diodes fabricated with different materials and wavelengths between 660 and 1550 nm. A new approach is developed that evaluates degradation below the laser threshold to determine the radiation-induced recombination density. This allows mechanisms at high injection, such as Auger recombination, to be separated from low-injection damage. New results show that AlGaInP lasers in the visible region are nearly an order of magnitude more resistant to radiation than devices fabricated with AlGaAs or AlGaAsP at longer wavelengths.

laser degradation↗

Mathematical optimization of photovoltaic converters for diode lasers

The mathematical optimization of vertical-junction photovoltaic converters for use with diode laser arrays supplying powers up to 1 MW is discussed. Photovoltaic parameters were optimized using a mathematical model. The optimized converters have 500 single junctions connected in series. The efficiency varies from 41 percent for a 0.73-micron diode laser to 46 percent for a 0.83-micron diode laser. The optimum width of the single-junction converter is small, 3.0 microns, in order for the p-n junction to be within a diffusion length of the light-generated carriers. Another critical parameter is the series resistance; the optimum value of 0.001 ohms should be achievable. Another critical parameter is the donor carrier concentration, for which an optimum value of 5 x 10 to the 15th carriers/cu cm has been chosen.

Walker, Gilbert H.↗

Facet effects on generation-recombination currents in semiconductor laser diodes

The contribution of facet defect currents to the overall generation-recombination current of laser diodes operating near 800 nm is quantified experimentally, using the dependence of current on cavity length to isolate facet effects. Here the results show that facet currents exhibit an ideality factor much greater than 2, while currents associated with the interior of the laser diode stripes exhibit an ideality factor of 2. These differences in behavior provide an approach to infer additional details of defect evolution in aging studies of semiconductor laser diodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative Detection of Combustion Species using Ultra-Violet Diode Lasers

Southwest Sciences is developing a new microgravity combustion diagnostic based on UV diode lasers. The instrument will allow absolute concentration measurements of combustion species on a variety of microgravity combustion platforms including the Space Station. Our approach uses newly available room temperature UV diode lasers, thereby keeping the instrument compact, rugged and energy efficient. The feasibility of the technique was demonstrated by measurement of CH radicals in laboratory flames. Further progress in fabrication technology of UV diode lasers at shorter wavelengths and higher power will result in detection of transient species in the deeper UV. High sensitivity detection of combustion radicals is provided with wavelength modulation absorption spectroscopy.

Pilgrim, J. S.↗

Diode-Laser-Based Spectrometer for Sensing Gases

A diode-laser-based spectrometer has been developed for measuring concentrations of gases and is intended particularly for use in analyzing and monitoring combustion processes under microgravitational conditions in a drop tower or a spacecraft. This instrument is also well suited for use on Earth in combustion experiments and for such related purposes as fire-safety monitoring and monitoring toxic and flammable gases in industrial settings. Of the gas-sensing spectrometers available prior to the development of this instrument, those that were sensitive enough for measuring the combustion gases of interest were too large, required critical optical alignments, used far too much electrical power, and were insufficiently rugged for use under the severe conditions of spacecraft launch and space flight. In contrast, the present instrument is compact, consumes relatively little power, and is rugged enough to withstand launch vibrations and space flight. In addition, this instrument is characterized by long-term stability, accuracy, and reliability. The diode laser in this spectrometer is operated in a wavelength-modulation mode. Different gases to be measured can be selected by changing modular laser units. The operation of the laser is controlled by customized, low-power electronic circuitry built around a digital signal-processor board. This customized circuitry also performs acquisition and analysis of data, controls communications, and manages errors.

Silver, Joel A.↗

Arrangement for damping the resonance in a laser diode

An arrangement for damping the resonance in a laser diode is described. This arrangement includes an additional layer which together with the conventional laser diode form a structure (35) of a bipolar transistor. Therein, the additional layer serves as the collector, the cladding layer next to it as the base, and the active region and the other cladding layer as the emitter. A capacitor is connected across the base and the collector. It is chosen so that at any frequency above a certain selected frequency which is far below the resonance frequency the capacitor impedance is very low, effectively shorting the base to the collector.

Katz, J.↗

Controlling Fringe Sensitivity of Electro-Optic Holography Systems Using Laser Diode Current Modulation

Electro-Optic Holography (EOH) is a non-intrusive, laser-based, displacement measurement technique capable of static and dynamic displacement measurements. EOH is an optical interference technique in which fringe patterns that represent displacement contour maps are generated. At excessively large displacements the fringe density may be so great that individual fringes are not resolvable using typical EOH techniques. This thesis focuses on the development and implementation of a method for controlling the sensitivity of the EOH system. This method is known as Frequency Translated Electro-Optic Holography (FTEOH). It was determined that by modulating the current source of the laser diode at integer multiples of the object vibration, the fringe pattern is governed by higher order Bessel function of the first kind and the number of fringes that represent a given displacement can be controlled. The reduction of fringes is theoretically unlimited but physically limited by the frequency bandwidth of the signal generator, providing modulation to the laser diode. Although this research technique has been verified theoretically and experimentally in this thesis, due to the current laser diode capabilities it is a tedious and time consuming process to acquire data using the FTEOH technique.

Bybee, Shannon J.↗

Atmospheric solar absorption measurements in the 9-11 micron region using a diode laser heterodyne spectrometer

A tunable diode laser heterodyne radiometer was developed for ground based measurements of atmospheric solar absorption spectra in the 9 to 12 micron spectral range. The performance and operating characteristics of this tunable infrared heterodyne radiometer (TIHR) is discussed along with recently measured heterodyne solar absorption spectra in the 10 to 11 micron spectral region.

Harward, C. N.↗

Atmospheric solar absorption measurements in the 9 to 11 mu m region using a diode laser heterodyne spectrometer

A tunable diode laser heterodyne radiometer was developed for ground-based measurements of atmospheric solar absorption spectra in the 8 to 12 microns spectral range. The performance and operating characteristics of this Tunable Infrared Heterodyne Radiometer (TIHR) are discussed along with atmospheric solar absorption spectra of HNO3, O3, CO2, and H2O in the 9 to 11 microns spectral region.

Harward, C. N.↗

Reliability of constricted double-heterojunction AlGaAs diode lasers

Constricted double-heterojunction diode lasers have been life tested at 70 C heatsink temperature and 3-4 mW/facet in CW operation. A median life of 7800 h is obtained at 70 C, which extrapolates to 400,000 h median life at room temperature. The extrapolated mean time to failure at room temperature is in excess of 1,000,000 h. Single-longitudinal-mode CW operation is maintained after 10,000 h of accelerated aging at 70 C.

Botez, D.↗

Tunable-diode laser absorption spectrometry

Tunable-diode laser absorption spectrometry (TDLAS) affords a number of advantages for atmospheric measurements. It is a universal method, applicable, in principle, to all gases of atmospheric interest. Because of its extremely high spectral resolution it provides unequivocal identification of the target species, with no interferences from other gases. It provides real-time, in situ measurements with time resolutions better than 1 minute. The sensitivity of the current TDLAS system is marginally capable of measuring HO2. This species exists in the troposphere at concentrations which are up to 2 orders of magnitude higher than those of HO and, in addition, is much less susceptible to removal by the surfaces of the instrument and its sampling system. HO2 is an important HO sub x species in its own right but can also give direct information on the HO concentration by virtue of the rapid partitioning between these two species. The addition of the high-frequency modulation technique to the TDLAS system would ensure its ability to measure HO2 under most atmospheric conditions. The ability of the TDLAS to measure hydrogen peroxide (H2O2) in the ambient atmosphere was also demonstrated. H2O2 measurements give a clear indication of HO sub x mixing ratios and are also important as a photolytic source of HO and as an important oxidant for other atmospheric consitituents such as SO2.

Schiff, H. I.↗

Fast-response, high-precision carbon monoxide sensor using a tunable diode laser absorption technique

A tunable diode laser instrument, denoted as DACOM (Differential Absorption CO Measurement), has been developed to meet the fast-response, high-precision CO measurement needs of the GTE (Global Tropospheric Experiment) program. Under the GTE program, DACOM participated in the three field missions of CITE 1 (Chemical Instrumentation Test and Evaluation 1), a project involving the intercomparison of trace gas measurement techniques. DACOM performance, including analyses of measurement error sources, is discussed for the ground-based mission at Wallops Island, VA (summer 1983), and two missions on the NASA CV-990 (fall 1983 and spring 1984). Examples of fast-response (about 1 s), high-precision (+ or - 1 part per billion by volume, + or - 1.5 percent of reading) airborne data are included to illustrate the capability of this instrument.

Sachse, Glen W.↗

Intrusions in the active layer of channeled-substrate-planar laser diodes

Channeled-substrate-planar laser diodes from various wafers were observed to develop a node or dark spot in their near-field patterns after failure during lifetesting. 'Node' devices from each wafer were angle-lapped and stained in an attempt to uncover a physical mechanism for this common failure symptom. Optical microscopic examination of the beveled cross sections revealed that an intrusion, in the form of a spike at the tip of the zinc diffusion front, had penetrated into the active layer of these diodes. The node observed in the near-field pattern appears to be in a position correspondig to the location of the spike in the active region. In addition, cathodoluminescence measurements on other 'node' diodes revealed a dark line region approximately 2-micron-wide running parallel to and in the middle of the 5-micron contact stripe. It is believed that this dark line region is representative of an area of nonradiative recombination which occurs in the portion of the active layer containing the intrusion.

Slavin, S. E.↗

Continuous-wave operation of a room-temperature, diode-laser-pumped, 946-nm Nd:YAG laser

Single-stripe diode-laser-pumped operation of a continuous-wave 946-nm Nd:YAG laser with less than 10-mW threshold has been demonstrated. A slope efficiency of 16 percent near threshold was shown with a projected slope efficiency well above a threshold of 34 percent based on results under Rhodamine 6G dye-laser pumping. Nonlinear crystals for second-harmonic generation of this source were evaluated. KNbO3 and periodically poled LiNbO3 appear to be the most promising.

Fan, T. Y.↗

Self-Collimating Unstable-Resonator Diode Lasers

Proposed unstable-resonator diode lasers produce solid, collimated output beams without external collimating optics. Simpler to construct, used as pumps for optical-fiber amplifiers in telecommunications, for other solid-state lasers, and sources of light for free-space communications.

Lang, Robert J.↗