Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOSIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A neutron fluence map of the Los Alamos National Laboratory Godiva IV critical assembly

A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Review of the Resuspension of Radioactively Contaminated Particles by Vehicle and Pedestrian Traffic—Current Theory, Practice, Gaps, and Needs

Here, the resuspension of radioactively contaminated particles in a built environment, such as from urban surfaces like foliage, building exteriors, and roadways, is described empirically by current plume and dosimetry models used for hazard assessment and long-term risk purposes. When applying these models to radiological contamination emergencies affecting urban areas, the accuracy of the results for recent contamination deposition is impacted in two main ways. First, the data supporting the underlying resuspension equations was acquired for open, quiescent conditions with no vehicle traffic or human activities, so it is not necessarily representative of the urban environment. Second, mechanical disturbance by winds in urban canyons and during emergency operations caused by vehicle traffic and human activities are not directly considered by the equations. Accordingly, plume and dosimetry models allow the user to input certain compensating values, but the models do not necessarily supply users instructions on what values to use. This manuscript reviews the available literature to comprehensively and consistently pool data for resuspension due to mechanically induced resuspension applicable to urban contamination. Because there are few studies that directly measured radioactive resuspension due to vehicles and pedestrians, this review novelly draws on a range of other studies involving non-radioactive particles, ranging from outdoor air pollution emissions to indoor allergen transport. The results lead to tabulated, recommended values for specific conditions in the emergency phase to help users of plume and dosimetry models maintain the conservativeness needed to properly capture the potential radiation dose posed by mechanically induced resuspension. These values are of benefit to model users until better data are available. The results also suggest the types of data that may result in improved plume and dose modeling.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of ionising radiation exposure in offspring and next generations: dosimetric aspects and uncertainties

The impact of the exposure to ionizing radiation in the offspring and next generation has been investigated in the last decades and currently is the subject of study of the ICRP Task Group 121. Studying the effects of radiation exposure in pre-conceptional and post-conceptional phases can be a challenge since potential effects to the fetus vary depending on the stage of fetal development. Epidemiology and radiobiology studies are the two sources of information one can use to correlate the radiation dose to the human body and tissues and the resulting effects. For a proper evaluation of the outcomes of such studies, and a correct appraisal of the exposure/dose-effect relationship, (i) reliable dosimetry, (ii) accurate reporting, and (iii) reproducibility of results are required. Although variables related to dose, including for instance source of radiation, geometry of irradiation, dose rate etc., are usually known, especially in radiobiology studies, often important details of the irradiation are not reported. In conclusion, based on standards developed by the National Cancer Institute (NCI), the National Institute of Allergy and Infectious Disease (NIAID) and the National Institute of Standards and Technology (NIST), a review of the scientific studies used by the UNSCEAR to estimate the risk of hereditary effects, and by the ICRP in its current recommendations, was conducted to evaluate the way dosimetry was reported. Dosimetry and the related uncertainties were not adequately described in the vast majority of those studies. This does not necessarily mean that they do not provide relevant information, however it prevents from a thorough verification and reproduction of their findings. In order to guarantee the reliability and robustness of the process of revision of the estimates of risk and detriment it is therefore considered mandatory to include a careful check of the new relevant literature with regard to the criteria on the completeness and reproducibility of the dosimetric information.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Evaluation of Triage Methods for Criticality Accidents

Studies indicate that early identification of persons involved in and receiving high doses of radiation in accidents is key to providing life-saving medical treatment. Although the risk of criticality accidents is low the potential impact to workers is significant. For facilities that employ large numbers of workers a key element in the response to a radiological emergency is identifying personnel that received significant, and potentially harmful, doses. Also important is having the ability to screen large numbers of workers to identify persons that did not receive significant exposure so as to reduce the impact on emergency response efforts. At the Y-12 National Security Complex the focus on criticality accident response is the rapid triage of personnel in order to identify persons exposed to large radiation doses and to prioritize those persons receiving the highest exposures. Once identified personnel are transported to local medical facilities including the Radiation Emergency Assistance Center/Training Site (REAC/TS) for medical evaluation and treatment. The Y-12 external dosimetry program utilizes a number of techniques to identify and prioritize workers and these methods were evaluated at a criticality dosimetry intercomparison exercise. Finally, the methods used were shown to perform as intended and other sites may consider incorporating these methods into their accident dosimetry response procedures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Human in vitro metabolism of an environmental mixture of polycyclic aromatic hydrocarbons (PAH) found at the Portland Harbor Superfund Site

Polycyclic aromatic hydrocarbons (PAHs) are widespread environmental contaminants that pose health risks to humans. Toxicity testing approaches of PAHs have evolved from traditional rodent models to New Approach Methodologies (NAMs), such as high-throughput screening in zebrafish, enabling rapid evaluation of chemical hazards. However, translating toxicity findings from laboratory systems to humans remains difficult due to complexity and species-specific differences. Chemical dosimetry modeling offers a quantitative framework to bridge this gap, but its accuracy depends on robust knowledge of PAH metabolism. The objective of this study was to measure human metabolism rates of Supermix-10, the ten most abundant PAHs found at the Portland Harbor Superfund Site, to support development of human pharmacokinetic models. We incubated individual PAHs from Supermix-10 in pooled human liver microsomes and quantified parent PAH disappearance using high-performance liquid chromatography (HPLC) with UV and florescent detection. To assess the potential of mixture interactions, we also measured metabolism of all 10 compounds in an equimolar mixture and compared rates of parent disappearance to those observed for individual PAHs. All Supermix-10 PAHs demonstrated rapid parent compound disappearance in human hepatic microsomes. PAHs grouped into three metabolism patterns: high metabolism rates and capacity (2-methylnaphthalene, acenaphthylene, fluorene, naphthalene), high affinity metabolism that rapidly achieves low-level saturation (benzo[a]anthracene, chrysene), and moderate metabolism rates and capacity (fluoranthene, pyrene, retene, phenanthrene). Smaller PAHs exhibited faster metabolism, and higher metabolism rates correlated inversely with molecular weight. When incubated in an equimolar mixture, Supermix-10 demonstrated significantly slower metabolism (47–89 %) compared to metabolism of individual PAHs at the same concentration. These findings enhance our understanding of PAH metabolism in humans and demonstrate significant mixture interactions under the conditions tested. Furthermore, our findings offer insights into the metabolic behavior of Supermix-10 and provide critical metabolism rate data to support the development of physiological based pharmacokinetic (PBPK) models. Dosimetry models can translate PAH chemical dosimetry from high-throughput testing platforms, like zebrafish and cellular system assays, to human exposures enhancing the accuracy and reliability of PAH risk assessments.

2-methylnaphthalene↗

Lung Cancer in the Mayak Workers Cohort: Risk Estimation and Uncertainty Analysis

The workers at the Mayak nuclear facility near Ozyorsk, Russia are a primary source of information about exposure to radiation at low-dose rates, since they were subject to protracted exposures to external gamma rays and to internal exposures from plutonium inhalation. Here we re-examine lung cancer mortality rates and assess the effects of external gamma and internal plutonium exposures using recently developed Monte Carlo dosimetry systems. Using individual lagged mean annual lung doses computed from the dose realizations, we fit excess relative risk (ERR) models to the lung cancer mortality data for the Mayak Workers Cohort using risk-modeling software. We then used the corrected information matrix (CIM) approach to widen the confidence intervals of ERR by taking into account the uncertainty in doses represented by multiple realizations from the Monte Carlo dosimetry systems. Findings of this work revealed that there were 930 lung cancer deaths during follow-up. Plutonium lung doses (but not gamma doses) were generally higher in the new dosimetry systems than those used in the previous analysis. This led to a reduction in the risk per unit dose compared to prior estimates. The estimated ERR/Gy for external gamma-ray exposure was 0.19 (95% CI: 0.07 to 0.31) for both sexes combined, while the ERR/Gy for internal exposures based on mean plutonium doses were 3.5 (95% CI: 2.3 to 4.6) and 8.9 (95% CI: 3.4 to 14) for males and females at attained age 60. Accounting for uncertainty in dose had little effect on the confidence intervals for the ERR associated with gamma-ray exposure, but had a marked impact on confidence intervals, particularly the upper bounds, for the effect of plutonium exposure [adjusted 95% CIs: 1.5 to 8.9 for males and 2.7 to 28 for females]. In conclusion, lung cancer rates increased significantly with both external gamma-ray and internal plutonium exposures. Accounting for the effects of dose uncertainty markedly increased the width of the confidence intervals for the plutonium dose response but had little impact on the external gamma dose effect estimate. Adjusting risk estimate confidence intervals using CIM provides a solution to the important problem of dose uncertainty. This work demonstrates, for the first time, that it is possible and practical to use our recently developed CIM method to make such adjustments in a large cohort study.

uncertainty, radiation risk estimation, Mayak Prod↗

Modeling and Design of Micro Flux Monitors for Neutron Fluence Measurements

Measuring neutron flux is critical to understanding the characteristics of nuclear reactors and can provide information on the energy spectrum, total neutron fluence, and operational history of a facility. Such measurements are typically performed by irradiating high-purity materials in an operating reactor for a known length of time. By measuring and identifying activation products in the irradiated materials and referencing the energy-dependent cross section of each isotope, the neutron energy spectrum and total fluence can be determined. Historical techniques use a variety of small, individually pressed foils or wires for dosimeter devices, which can result in excessively high levels of radioactivity and complications in handling after irradiation. The present work describes a new neutron dosimetry concept, named the micro flux monitor, that uses semiconductor device fabrication processes to deposit thin films of flux monitoring materials in precise geometries onto a SiC wafer. This approach allows multiple dosimetry materials to be located on a single device, simplifying irradiation and subsequent analysis. The geometry, and therefore mass, of each material can be custom-tailored for a specific application—considering the expected neutron flux, duration of irradiation, and device retrieval time of a facility. Additionally, hundreds of identical dosimetry monitors can be produced simultaneously, reducing fabrication costs. Finally, the extremely thin metal dimensions of these devices could improve the fidelity of neutron fluence measurements by reducing neutron self-shielding and gamma self-attenuation effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative assessment of neutron flux sensor technologies for advanced reactors

This report documents the comparative assessment of the rhodium-based self-powered neutron detectors (Rh-SPND), micro-pocket fission detectors (MPFD), and dosimetry wires in heated irradiations at the Neutron Radiography reactor facility at Idaho National Laboratory. The sensors performances are evaluated high-temperature environments (upwards of 850°C) during maximum reactor power to simulate use in advanced reactor applications. The performance of the Rh-SPNDs indicates the experiment cartridge heater power supply interferes with the SPND signals. This interference become increasingly significant at temperatures above 500°C with minimal interference observed for temperatures below 500°C. This work also demonstrated the fabrication process for the updated design of the MPFD, but issues related to the seal welds were identified and usable data was limited. Finally, the dosimetry measurements were within the expected range correlated with reactor power; thus, the dosimetry results were used to provide preliminary SPND calibration factors. The results from this experiment serves as a reference for developing and testing of flux sensors that are designed for high-temperature irradiations and advanced reactor deployments. This includes upcoming FY22 irradiations at the Massachusetts Institute of Technology Reactor and the Neutron Radiography (NRAD) reactor utilizing additional fission chambers from Photonis Technologies and fission chambers and SPNDs from The French Alternative Energies and Atomic Energy Commission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary analysis of TREAT free-field experiments using openmc

This work analyses activation calculations for dosimetry materials during a steady-state irradiation in the Transient Reactor Test (TREAT) reactor core. Hence, we developed a workflow based on the Monte Carlo code OpenMC alongside a custom depletion solver. The irradiation-induced activity as a function of time is computed, and several sensitivity studies are performed to evaluate uncertainty. This study has shown activity computations are sensitive to flux amplitude, irradiation time, atoms quantity and microscopic cross sections. Stochastic uncertainties have been propagated to evaluate the activity uncertainty for each dosimetry material. Most uncertainties are below our target of 3%, which demonstrates OpenMC as a powerful predictive and analysis tool. The precise results obtained through this newly developed computation scheme will be used in future experiments to characterize quantities of interest when operating the TREAT reactor in new configurations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Biokinetic and Dosimetric Models [Slides]

Presentation describes internal dosimetry as an intersection of disciplines involving Physiology, Anatomy, Physics, Mathematics and Computer Science, which some people call "The art of Internal Dosimetry". The basic components for internal dose calculations are: Biokinetic (metabolic) models describing the intake, distribution, retention and excretion of radionuclides in the body, Dosimetric models describing the interaction of radiation within the several body organs and tissues, and System of dose limitation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Au-198 and TLD-600 results from IER-593 Godiva irradiations

This report summarizes the results from dosimetry packets deployed during a nominally 250 ◦C temperature rise Godiva IV burst. Dosimetry packets including Bare Au foils, Cd covered Au foils, and Thermoluminescent Dosimeters (TLDs) were deployed at five positions around Godiva at a height corresponding to the center height of the HEU fuel.

61 RADIATION PROTECTION AND DOSIMETRY↗

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications

Polylactic acid (PLA) as a “green,” renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1–100 kGy range–of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12–16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0–11 kGy; and to 193 °C for the extended Dg range: 11–120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0–11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0–120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0–16 kGy experiments, and compressed 2 min at 232 °C in the 16–110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0–16 kGy range and from ~0 to ~18% over the 16–114 kGy range. These results provide evidence for utilizing “green”/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5–10%) gamma dosimetry over a wide 0–120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tensioned metastable fluid detector sensing technology for multifarious-multiscale applications in the nuclear fuel cycle

The nuclear fuel cycle presents formidable 10 30+ multiscale challenges for high-efficiency spectroscopic sensing of alpha-neutron-fission radiation signatures amidst extreme gamma-beta radiation backgrounds at various stages of the cycle; it involves diverse arenas ranging from continuous/pulsed power production, security/safeguards, spent fuel, environmental remediation, and personnel health-dosimetry. This paper discusses the novel tensioned metastable fluid detector (TMFD) sensor technology. It discusses the results of studies demonstrating extreme (10 4 Sv/h) gamma-beta field blind high intrinsic efficiencies (80–100%) for neutron-alpha-fission radiation spectrometric detection. Example studies discussed in this paper include Neutron detection with spectroscopy; H*10 neutron radiation dosimetry upwards from ultra-low10 −2 µSv/h levels; Air and/or liquid-borne trace (10 –3 Bq/mL) quantity, 1 keV energy resolved alpha/fission spectroscopy for Rn/Po/U/Pu/Am environmental isotope assays at 106:1 (β:α) ratios; Directional-position enabled extended standoff tracking of neutron emitting (shielded/unshielded) special nuclear materials while stationary or moving at highway speeds; and, U.S. Department of Energy nuclear complex wide nuclear waste reprocessing, criticality safety, health physics, and environmental applications.

Alpha-fission-neutron spectrometry↗

Integrating HPC simulations and physical experiments to characterize the effects of gamma radiation on seismic protective devices

Seismic protective systems, composed of seismic isolators and dampers, can substantially reduce the effects of earthquake shaking on nuclear power plants and components therein. To enable the use of these devices to protect equipment inside a plant and close to a source of radiation, the U.S. Department of Energy (DOE) funded a project at the Idaho National Laboratory (INL) and the University at Buffalo to characterize the effects of absorbed gamma dose on their mechanical properties. An early task in the project was to determine the exposure time required in the INL Foss Therapy Services (FTS) 60 Co gamma irradiator to achieve a target absorbed dose in the materials used to construct isolators and dampers, including fluids, polymers, composites, and metals. This task required the novel integration of high-performance computing (HPC), Monte Carlo N-Particle (MCNP) simulations, and irradiation experiments using Fricke dosimetry. An MCNP model of the FTS irradiator at INL was developed and validated using Fricke dosimetry. Simulations of three experiments in the irradiator, two with Fricke vials only and one with Fricke vials and a large-size isolator, predicted the Fricke-measured absorbed dose rate to within 15% in all three cases, providing high confidence in the calculation of the gamma dose absorbed in the materials comprising the seismic protective devices. The simulations demonstrated that the effects of photon scattering on absorbed dose rate in the FTS irradiator are negligible for test articles installed close to the cobalt sources and near the rear of the irradiator. The validated MCNP model of the FTS irradiator is being used to support ongoing DOE-funded experiments on seismic protective devices and could be applied to future, non-seismic-related experiments. In conclusion, the novel validation process successfully deployed for the FTS irradiator at INL could be applied to other irradiators, requiring new MCNP models and simulations, and irradiation experiments using dosimeters.

42 - ENGINEERING↗

Thermoluminescence and optically stimulated luminescence response of Al 2 O 3 coatings deposited by mist-chemical vapor deposition

Aluminum oxide (Al 2 O 3 ) is a widely used ceramic material which can be applied as a protective coating on metallic structures to improve corrosion resistance and mechanical properties. Al 2 O 3 also has great potential as a functional thin film device in optoelectronics. When it is doped with carbon (Al 2 O 3 :C), this material system can serve as a reliable radiation dosimeter. The combination of optoelectronic, dosimetric, and protective properties demonstrated by Al 2 O 3 uniquely positions it for dual use applications in nuclear forensics, nonproliferation and safeguards, emergency response, retrospective dosimetry, and nondestructive inspection. Here, in this study, an innovative ultrasonic mist-chemical vapor deposition (Mist-CVD) system was used to deposit thin (nm level) Al 2 O 3 coatings on 304 stainless steel substrates. The single aliquot regeneration (SAR) and additive dose reconstruction techniques were then used to investigate the thermoluminescence (TL) and optically stimulated luminescence (OSL) response of the coated substrates to increasing doses of β irradiation. This study demonstrates that nm-thick Al 2 O 3 coatings hold promise as novel nano-dosimeters which could be leveraged for a series of applications such as nonproliferation and safeguards, retrospective dosimetry, and nondestructive inspection.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

EPR-based uncertainty validation of the calculated external doses for population exposed in the urals region

Tooth enamel Electron Paramagnetic Resonance (EPR) spectroscopy was used as a method for external dosimetry in the territories contaminated in the 1950s by PA ‘Mayak’ (Urals region) to validate the mean dose estimates predicted by the Techa River Dosimetry System (TRDS). The purpose of this study is to validate the uncertainties of TRDS doses. Ninety percent confidence intervals (90% confidence interval, CI) of dose estimated with both methods were compared for 220 people. All data were grouped according to the width of 90%CI, viz.: (1) 90%CI of EPR-based dose ≤ 90%CI of TRDS prediction (38 cases); (2) 90%CI of EPR-based dose > 90%CI of TRDS prediction (182 cases). About 91% of 90%CIs overlap. In group 1, 100% cases overlap. In group 2, 80% of the cases were non-contradictive (the calculated 90%CI is completely within the measured one). Interval comparison of doses predicted retrospectively and estimated based on individual measurements are non-contradictory and demonstrate a good agreement.

61 RADIATION PROTECTION AND DOSIMETRY↗

High Flux Isotope Reactor Neutron Spectrum Shape Estimation From Activation Experiment Data

Here, this article provides a comprehensive review of historical irradiation dosimetry available for different locations within the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). This article includes a summary of the available measured activation target data covering a span of over 15 years and 39 experimental campaigns, including 200 individual sample locations evaluated. Using this broad set of data, we reconstruct historic average neutron spectra shapes for HFIR at various locations, including within the flux trap region, beryllium reflectors, and hydraulic tube (HT) regions, at both the 100- and 85-MW operational power. Our findings indicate that the general axial flux distribution shows a relatively small change in transition from 100- to 85-MW operating power, with differences of -6% to +15% for the thermal energy range and around -16% to +8% for the fast range, indicating a sharper drop-off of the thermal neutron flux away from the axial center. Compared with historical dosimetry estimates of the HFIR flux shape, we generally find a moderately broader axial profile shape for thermal neutrons in the interior target regions for the 100-MW samples evaluated but relatively close agreement for the present 85-MW flux shape for both thermal and fast fluxes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗