Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data scouting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

115 records · Page 7

OMI Tropospheric NO2 from Lightning in Observed Convective Events

Lightning is responsible for an estimated 15 percent of total NO emissions, and is one of the most prominent sources in the upper troposphere. In this study, we present evidence of lightning-generated NO2 (LNO2) using data from the Ozone Monitoring Instrument (OMI), which has observed tropospheric NO2 since its launch in 2004. Although LNO2 has been also reported in previous satellite studies from the Global Ozone Monitoring Experiment (GOME) and SCIAMACHY, OMI is better suited for such measurements by virtue of its higher spatial resolution and daily global coverage. We will present data clearly showing the LNO2 signal in the OMI tropospheric NO2 product on two days over and downwind of specific convective systems in the US Midwest. Gridded monthly mean tropospheric NO 2 data are subtracted from the daily gridded data to obtain the presumed LNO2 signal. Observed cloud-to-ground (CG) lightning flashes from the National Lightning Detection Network (NLDN) were counted along middle and upper tropospheric back trajectories that were run from the regions containing the LNO2 signal. A vertically-weighted average number of upwind CG flashes was obtained using a profile of LNO(x) mass obtained from a series of midlatitude cloud-resolved storm chemistry simulations. The number of CG flashes was scaled up to total flashes (intracloud (IC) flashes plus CG) using a climatological IC/CG ratio. The number of moles of LNO(x) in the region considered was estimated by assuming that LNO2 is 30 percent of LNO(x). This value was divided by the number of upwind flashes to obtain an average estimate of the number of moles produced per flash. Results yield values in the range obtained through other estimation techniques (e.g., aircraft measurements, models). We will also present a similar analysis over northern Australia during the SCOUT-O3/ACTIVE field campaigns in November and December 2005, in which we will compare the OMI LNOx signals with aircraft observations from the storm anvils.

Pickering, Kenneth↗

Evaluating the Viability of Compact and Portable X-Ray Systems for an Exploration Medical System in a Ground Demonstration

MOTIVATION FOR INCLUDING X-RAY CAPABILITIES For upcoming exploration missions, the need for enhanced medical care becomes critical due to extended mission durations, significant communication delays, and minimal evacuation opportunities. Previous evidence by our team has revealed that among the 119 medical conditions targeted for management during spaceflight within NASA Exploration Medical Capability’s IMPACT Condition List, at least 36 could benefit from radiography (XR). Utilizing XR for diagnosis and management is hypothesized to significantly improve management of crew health by enabling the immediate evaluation and confirmation of potential injuries or illnesses. Beyond clinical applications, XR also holds potential for non-destructive testing (NDT). This includes applications such as assessing the structural integrity of the spacecraft, analyzing surface and meteorite samples, and inspecting onboard electronics. THREE CANDIDATE X-RAY SYSTEMS CHOSEN FOR GROUND DEMONSTRATION The Exploration Medical Capability Element (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) of the Mars Campaign Office initiated early background work for ground demonstrations. In FY21, ExMC published a Concept of Operations to guide requirements development. By FY23, XMIPT and yet2, a technology scouting and open innovation consulting firm, had completed a market survey and trade study to identify potential miniature XR systems. Selection criteria included commercial-off-the-shelf availability, low mass and volume, and regulatory compliance. The top three candidate devices—Remedi REMEX-KA6, MinXray Impact, and FujiFilm Xair—were acquired to characterize the requirements and capabilities of each device. To facilitate testing, phantoms, and radiographic personal protective equipment (PPE) were purchased, and a dedicated space was designated for XRS usage at Glenn Research Center. During this presentation, the mass, volume, and power requirements for each of the three piloted devices are revealed, as well as information regarding the detector, mA, and kV of the devices. GOAL AND OBJECTIVES OF A MINI XRS GROUND DEMONSTRATION The primary goal of ExMC/XMIPT technology demonstrations is to bridge the gap in available, flight-ready medical device technology by flight-testing diagnostic and treatment technologies essential for managing medical conditions during exploration missions. These technologies must adhere to vehicle constraints such as mass, volume, power, and data requirements, integrate seamlessly with medical decision-support tools, and support increasingly Earth-independent operations. There are three main objectives for the future ground demonstration of these three devices. First, we aim to determine the full capabilities of these three miniature XR systems within the context of the spaceflight environment. While medical applications are the primary focus for the miniature XR, a comprehensive exploration of non-medical uses has been initiated by an XMIPT-sponsored NASA SPARK campaign to identify collaborators. Second, we plan to establish criteria and to use insights gained from evaluating each miniature XR against those criteria to select the most suitable system among the three candidates. Third, we intend to evaluate their suitability for flight certification, which includes assessing its durability for launch, reentry, and exposure to high background radiation, as well as its compatibility with existing data architecture systems. Numerous subject matter experts from NASA and partner institutions will support these objectives.

C A Haddix↗

Lessons from Astrobiological Planetary Analogue Exploration in Iceland: Biomarker Assay Performance and Downselection

Understanding the sensitivity of biomarker assays to the local physicochemical environment, and the underlying spatial distribution of the target biomarkers in 'homogeneous' environments, can increase mission science return. We have conducted four expeditions to Icelandic Mars analogue sites in which an increasingly refined battery of physicochemical measurements and biomarker assays were performed, staggered with scouting of further sites. Completed expeditions took place in 2012 (location scouting and field assay use testing), 2013 (sampling of two major sites with three assays and observational physicochemical measurements), 2015 (repeat sampling of prior sites and one new site, scouting of new sites, three assays and three instruments), and 2016 (preliminary sampling of new sites with analysis of returned samples). Target sites were geologically recent basaltic lava flows, and sample loci were arranged in hierarchically nested grids at 10 cm, 1 m, 10 m, 100 m, and >1 km order scales, subject to field constraints. Assays were intended to represent a diversity of potential biomarker types (cell counting via nucleic acid staining and fluorescence microscopy, ATP quantification via luciferase luminescence, and relative DNA quantification with simple domain-level primers) rather a specific mission science target, and were selected to reduce laboratory overhead, require limited consumables, and allow rapid turnaround. All analytical work was performed in situ or in a field laboratory within a day's travel of the field sites unless otherwise noted. We have demonstrated the feasibility of performing ATP quantification and qPCR analysis in a field-based laboratory with single-day turnaround. The ATP assay was generally robust and reliable and required minimal field equipment and training to produce a large amount of useful data. DNA was successfully extracted from all samples, but the serial-batch nature of qPCR significantly limited the number of primers (hence classifications) and replicates that could be run in a single day. Fluorescence microscopy did not prove feasible under the same constraints, primarily due to the large number of person-hours required to view, analyze, and record results from the images; however, this could be mitigated with higher-quality imaging instruments and appropriate image analysis software.

Planetary↗

Combustion of Organic Molecules by the Thermal Decomposition of Perchlorate Salts: Implications for Organics at the Mars Phoenix Scout Landing Site

The Mars 2007 Phoenix Scout Mission successfully landed on May 25, 2008 and operated on the northern plains of Mars for 150 sols. The primary mission objective was to study the history of water and evaluate the potential for past and present habitability in Martian arctic ice-rich soil [1]. Phoenix landed near 68 N latitude on polygonal terrain created by ice layers that are a few centimeters under loose soil materials. The Phoenix Mission is assessing the potential for habitability by searching for organic molecules in the ice or icy soils at the landing site. Organic molecules are necessary building blocks for life, although their presence in the ice or soil does not indicate life itself. Phoenix searched for organic molecules by heating soil/ice samples in the Thermal and Evolved-Gas Analyzer (TEGA, [2]). TEGA consists of 8 differential scanning calorimeter (DSC) ovens integrated with a magnetic-sector mass spectrometer with a mass range of 2-140 daltons [2]. Endothermic and exothermic reactions are recorded by the TEGA DSC as samples are heated from ambient to ~1000 C. Evolved gases, including any organic molecules and their fragments, are simultaneously measured by the mass spectrometer during heating. Phoenix TEGA data are still under analysis; however, no organic fragments have been identified to date in the evolved gas analysis (EGA). The MECA Wet Chemistry Lab (WCL) discovered a perchlorate salt in the Phoenix soils and a mass 32 peak evolved between 325 and 625 C for one surface sample dubbed Baby Bear [3]. The mass 32 peak is attributed to evolved O2 generated during the thermal decomposition of the perchlorate salt. Perchlorates are very strong oxidizers when heated, so it is possible that organic fragments evolved in the temperature range of 300-600 C were combusted by the O2 released during the thermal decomposition of the perchlorate salt. The byproduct of the combustion of organic molecules is CO2. There is a prominent release of CO2 between 200-600 C for several of the Phoenix soils analyzed by TEGA. This low temperature release of CO2 might be any combination of 1) desorption of adsorbed CO2, 2) thermal decomposition of Fe- and Mg-carbonates, and 3) combustion of organic molecules [2].

Ming, D.W.↗

Thermal and Evolved Gas Behavior of Calcite Under Mars Phoenix TEGA Operating Conditions

The Mars Phoenix Scout Mission with its diverse instrument suite successfully examined several soils on the Northern plains of Mars. The Thermal and Evolved Gas Analyzer (TEGA) was employed to detect organic and inorganic materials by coupling a differential scanning calorimeter (DSC) with a magnetic-sector mass spectrometer (MS). Martian soil was heated up to 1000 C in the DSC ovens and evolved gases from mineral decomposition products were examined with the MS. TEGA s DSC has the capability to detect endothermic and exothermic reactions during heating that are characteristic of minerals present in the Martian soil. Initial TEGA results indicated the presence of endothermic peaks with onset temperatures that ranged from 675 C to 750 C with corresponding CO2 release. This result suggests the presence of calcite (CaCO3. CaO + CO2). Organic combustion to CO2 is not likely since this mostly occurs at temperatures below 550 C. Fe-carbonate and Mg-carbonate are not likely because their decomposition temperatures are less than 600 C. TEGA enthalpy determinations suggest that calcite, may occur in the Martian soil in concentrations of approx.1 to 5 wt. %. The detection of calcite could be questioned based on previous results that suggest Mars soils are mostly acidic. However, the Phoenix landing site soil pH was measured at pH 8.3 0.5, which is typical of terrestrial soils where pH is controlled by calcite solubility. The range of onset temperatures and calcite concentration as calculated by TEGA is poorly con-strained in part because of limited thermal data of cal-cite at reduced pressures. TEGA operates at <30 mbar while most calcite literature thermal data was obtained at 1000 mbar or higher pressures.

Ming, D.W.↗

Phoenix Lander's Thermal Evolved Gas Analyzer: Differential Scanning Calorimeter and Mass Spectrometer Database Development

The Mars Scout Phoenix lander will land in the north polar region of Mars in May, 2008. One objective of the Phoenix lander is to search for evidence of past life in the form of molecular organics that may be preserved in the subsurface soil. The Thermal Evolved Gas Analyzer (TEGA) was developed to detect these organics by coupling a simultaneous differential thermal analyzer (SDTA) with a mass spectrometer. Martian soil will be heated to approx.1000 C and potential organic decomposition products such as CO2, CH4 etc. will be examined for with the MS. TEGA s SDTA will also assess the presence of endothermic and exothermic reactions that are characteristic of soil organics and minerals as the soil is heated. The MS in addition to detecting organic decompositon products, will also assess the levels of soil inorganic volatiles such as H2O, SO2, and CO2. Organic detection has a high priority for this mission; however, TEGA has the ability to provide valuable insight into the mineralogical composition of the soil. The overall goal of this work is to develop a TEGA database of minerals that will serve as a reference for the interpretation of Phoenix-TEGA. Previous databases for the ill-fated Mars Polar Lander (MPL)-TEGA instrument only went to 725 C. Furthermore, the MPL-TEGA could only detect CO2 and H2O while the Phoenix-TEGA MS can examine up to 144 atomic mass units. The higher temperature Phoenix-TEGA SDTA coupled with the more capable MS indicates that a higher temperature database is required for TEGA interpretation. The overall goal of this work is to develop a differential scanning calorimeter (DSC) database of minerals along with corresponding MS data of evolved gases that can used to interpret TEGA data during and after mission operations. While SDTA and DSC measurement techniques are slightly different (SDTA does not use a reference pan), the results are fundamentally similar and thus DSC is a useful technique in providing comparative data for the TEGA database. The objectives of this work is to conduct DSC and MS analysis up to 1000 C of select minerals that may be found in the martian soil.

Sutter, B.↗

Findings from the Supersonic Qualification Program of the Mars Science Laboratory Parachute System

In 2012, the Mars Science Laboratory Mission (MSL) will deploy NASA's largest extra-terrestrial parachute, a technology integral to the safe landing of its advanced robotic explorer on the surface. The supersonic parachute system is a mortar deployed 21.5 m disk-gap-band (DGB) parachute, identical in geometric scaling to the Viking era DGB parachutes of the 1970's. The MSL parachute deployment conditions are Mach 2.3 at a dynamic pressure of 750 Pa. The Viking Balloon Launched Decelerator Test (BLDT) successfully demonstrated a maximum of 700 Pa at Mach 2.2 for a 16.1 m DGB parachute in its AV4 flight. All previous Mars deployments have derived their supersonic qualification from the Viking BLDT test series, preventing the need for full scale high altitude supersonic testing. The qualification programs for Mars Pathfinder, Mars Exploration Rover, and Phoenix Scout Missions were all limited to subsonic structural qualification, with supersonic performance and survivability bounded by the BLDT qualification. The MSL parachute, at the edge of the supersonic heritage deployment space and 33% larger than the Viking parachute, accepts a certain degree of risk without addressing the supersonic environment in which it will deploy. In addition, MSL will spend up to 10 seconds above Mach 1.5, an aerodynamic regime that is associated with a known parachute instability characterized by significant canopy projected area fluctuation and dynamic drag variation. This aerodynamic instability, referred to as "area oscillations" by the parachute community has drag performance, inflation stability, and structural implications, introducing risk to mission success if not quantified for the MSL parachute system. To minimize this risk and as an alternative to a prohibitively expensive high altitude test program, a multi-phase qualification program using computation simulation validated by subscale test was developed and implemented for MSL. The first phase consisted of 2% of fullscale supersonic wind tunnel testing of a rigid DGB parachute with entry-vehicle to validate two high fidelity computational fluid dynamics (CFD) tools. The computer codes utilized Large Eddy Simulation and Detached Eddy Simulation numerical approaches to accurately capture the turbulent wake of the entry vehicle and its coupling to the parachute bow-shock. The second phase was the development of fluid structure interaction (FSI) computational tools to predict parachute response to the supersonic flow field. The FSI development included the integration of the CFD from the first phase with a finite element structural model of the parachute membrane and cable elements. In this phase, a 4% of full-scale supersonic flexible parachute test program was conducted to provide validation data to the FSI code and an empirical dataset of the MSL parachute in a flight-like environment. The final phase is FSI simulations of the full-scale MSL parachute in a Mars type deployment. Findings from this program will be presented in terms of code development and validation, empirical findings from the supersonic testing, and drag performance during supersonic operation.

EDL↗