Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diagnostic Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Temporal structure of blobs in NSTX

The time dependence of the blob pulse shape and the waiting time between blobs was found using data from the gas puff imaging diagnostic in NSTX. The database used was of 103 shots from 2010 as described in a previous paper (Zweben et al., Phys. Plasmas 29, 012505 (2022).]. The blob pulse shape was well fit by an exponential rise and fall where the average rise time was τ r = 9.0 ± 2.7 μs and the average fall time was τ f = 16.6 ± 5.8 μs. The waiting times between blob pulses above a threshold of three times the mean had a broad distribution with an average of τ w = 1.2 ± 0.85 ms over the database. The blob intermittency parameter γ b = τ d /τ w , where the blob pulse duration was τ d = τ r + τ f , ranged from γ b ~1% to 5% for shots in this database and increased almost linearly with the blob fraction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An experimental and computational study of thin-layer Rayleigh–Taylor instability development during deceleration with and without an externally applied magnetic field

The importance of mitigating the Rayleigh–Taylor instability (RTI) in inertial confinement fusion (ICF) is critical to successfully achieve high gain fusion yield. Consequently, understanding the seed mechanisms of RTI and the potential evolution of RTI in ICF relevant conditions is crucial. Single feature perturbations consistently demonstrate non-linear RTI evolution, for which an experimental platform on OMEGA-EP is developed. Manufacturing defects introduced into the target design require exploration of unanticipated changes to RTI development and an identification of targets that will still render quantifiable physics results. Consequently, it is presented that the inherent 3D nature of experimental targets necessitates 3D modeling for accurate design work and predictive modeling of experimental targets, especially when high resolution imaging diagnostics, like Fresnel Zone Plates, are utilized. A study of the morphology of the RTI evolution due to changing initial conditions and the presence of an externally applied magnetic field are also explored. Experimental data show thin-layer RTI morphology comparable to resistive magneto hydrodynamic 3D results. A discussion on the impacts of an externally applied magnetic field makes the case for continued efforts to observe a magnetic field's impact on RTI morphology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel soft x-ray multi-energy camera to study thermal plasmas on WEST

A multi-energy soft x-ray (SXR) pinhole camera has been built, calibrated and deployed on the WEST tokamak to aid the study of thermal plasmas. This novel imaging diagnostic technique employs a 2D pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. This innovation allows the simultaneous measurement of x-rays with space, time and energy resolution. Measurements at lower energy (2–6 keV) dominated by tungsten line emission are used to estimate the tungsten concentration and the plasma ΔZ eff . Measurements at higher energy (11–18 keV), where only continuum emission is present, are employed to infer the plasma electron temperature. Other applications of this powerful diagnostic include the determination of the plasma SXR centroid vertical position, characterization of tungsten UFOs and various real-time measurements.

electron temperature↗

X-point and divertor filament dynamics from gas puff imaging on TCV

Abstract A new gas puff imaging diagnostic has been installed on the TCV tokamak, providing two-dimensional insights into scrape-off-layer (SOL) turbulence dynamics above, at and below the magnetic X-point. A detailed study in L-mode, attached, lower single-null discharges shows that statistical properties have little poloidal variations, while vast differences are present in the 2D behaviour of intermittent filaments. Strongly elongated filaments, just above the X-point and in the divertor far-SOL, show a good consistency in shape and dynamics with field-line tracing from filaments at the outboard midplane, highlighting their connection. In the near-SOL of the outer divertor leg, short-lived, high frequency and more circular (diameter ∼15 sound Larmor radii) filaments are observed. These divertor-localised filaments appear born radially at the position of maximum density and display a radially outward motion with velocity ≈400 m s −1 that is comparable to radial velocities of upstream-connected filaments. Conversely, in these discharges ( B → × ∇ B pointing away from the divertor), these divertor filaments’ poloidal velocities differ strongly from those of upstream-connected filaments. The importance of divertor-localised filaments upon radial transport and profile broadening is explored using filament statistics and in situ kinetic profile measurements along the divertor leg. This suggests that these filaments contribute significantly to electron density profile broadening in the divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric fields and stationary drift flows in the island divertor SOL of Wendelstein 7-X

Abstract In the island divertor scrape-off layer (SOL) of the Wendelstein 7-X stellarator, 2D-resolved Langmuir probe measurements uncover a complex spatial structure of electron temperature, density, and floating potential. Depending on details of magnetic island size and position, significant poloidal gradients and non-monotonic radial profiles are observed. The resulting electric fields imply the presence of sheared stationary drift flows with poloidal velocities of a few km/s, with flow channels as narrow as one cm. Such flows are observed with a gas puff imaging diagnostic in qualitative agreement with the probe results and imply a significant transport channel in the SOL. The 2D distribution of plasma parameters is intricately associated to the unique magnetic structure of the island divertor SOL and highlights the necessity for more accurate magnetic field reconstructions.

Killer, Carsten (ORCID:0000000177473066)↗

Photonuclear cross sections for the 197 Au ⁢(𝛾, 𝑝⁢𝑛)⁢ 195⁢𝑚 Pt reaction near threshold

Platinum radioisotopes are of growing interest for targeted cancer therapy and diagnostic imaging because their decay delivers highly localized radiation doses in tissue, herewith enabling precise DNA damage through Auger-electron emission. Developing production technologies that provide platinum isotopes with high specific activity is essential in radioisotope therapy. Photonuclear reactions on stable nuclei offer a viable accelerator-based route for isotope production when supported by reliable cross-section data. We report photonuclear cross-section measurements for the 197 Au(γ, pn) 195m Pt reaction at incident γ-ray energies of 27, 29, and 31 MeV using the activation method. The measurements were performed by irradiating a stack of concentric-ring gold targets with a quasi-monoenergetic γ-ray beam provided by the High Intensity Gamma-ray Source (HI γS). The induced 195m Pt activity was quantified using off-line γ-ray spectroscopy. These data provide the first experimental constraints on the 197 Au(γ, pn) 195m Pt cross section in the near-threshold region. Furthermore, the comparison of the measured excitation function to PHITS and TALYS calculations indicates that the reaction becomes measurable only near 30 MeV and that substantially higher bremsstrahlung end-point energies are required for practically meaningful production.

190 ≤ A ≤ 219↗

Measurement and modeling of proton-induced reactions on arsenic from 35 to 200 MeV

72 As is a promising positron emitter for diagnostic imaging that can be employed locally using a 72 Se generator. However, current reaction pathways to 72 Se have insufficient nuclear data for efficient production using regional 100–200 MeV high-intensity proton accelerators. In order to address this deficiency, stacked-target irradiations were performed at LBNL, LANL, and BNL to measure the production of the 72 Se/ 72 As positron emission tomography (PET) generator system via 75 As (p, x) between 35 and 200 MeV. This work provides the most well-characterized excitation function for 75 As ( p , 4 n ) 72 Se starting from threshold. Additional focus was given to report the first measurements of 75 As (p, x) 68 Ge and bolster an already robust production capability for the highly valuable 68 Ge/ 68 Ga PET generator. Thick target yield comparisons with prior established formation routes to both generators are made. In total, high-energy proton-induced cross sections are reported for 55 measured residual products from 75 As, nat Cu , and nat Ti targets, where the latter two materials were present as monitor foils. These results were compared with literature data as well as the default theoretical calculations of the nuclear model codes TALYS, COH, EMPIRE, and ALICE. Reaction modeling at these energies is typically unsatisfactory due to few prior published data and many interacting physics models. Therefore, a detailed assessment of the talys code was performed with simultaneous parameter adjustments applied according to a standardized procedure. Particular attention was paid to the formulation of the two-component exciton model in the transition between the compound and preequilibrium regions, with a linked investigation of level density models for nuclei off of stability and their impact on modeling predictive power. This paper merges experimental work and evaluation techniques for high-energy charged-particle isotope production in an extension to an earlier study of this kind.

43 PARTICLE ACCELERATORS↗

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]↗

Evolution of radiation protection for medical workers

Within a few months of discovery, X-rays were being used worldwide for diagnosis and within a year or two for therapy. It quickly became clear that while there were significant benefits, there were significant associated hazards, not only for the patients, but also for the operators of the equipment. Simple radiation protection measures were implemented within a decade or two and radiation protection for physicians and other operators has continued to evolve over the last century driven by cycles of widening uses, new technologies, realization of previously unidentified effects, development of recommendations and regulations, along with the rise of related societies and professional organizations. Today, the continue acceleration of medical radiation uses in diagnostic imaging and in therapeutic modalities not imagined at the turn of this century, such as positron emission tomography, calls for constant vigilance and flexibility to provide adequate protection for the growing numbers of medical radiation workers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Niowave Ancillary Systems – FY21: In Partial Fulfillment of the Deliverable Requirement for Niowave Ancillary Systems Support by LANL

Niowave Inc. produces medical radioisotopes within the US. Lead-bismuth eutectic (LBE) is irradiated using an electron beam to produce neutrons that are used in the production of Molybdenum-99 (Mo-99). The medical community relies on a steady supply of Mo-99 which is primarily used in medical diagnostic imaging. The irradiation of LBE results in high temperatures within the molten metal, this work focusses on the design of ancillary systems associated with the liquid metal system. The LBE is initially at a temperature of 200°C and flows over a steel plate to create a waterfall. The electron beam is then aimed at the waterfall to generate neutrons. The peak temperatures of the LBE post irradiation depend on the beam energy of the LINAC. For a 15 MeV and 20 kW beam, the temperatures can range between 300°C and 350°C. The LBE is cycled through the system to create a closed loop that requires the post-irradiation LBE to be cooled back to 200°C. This work focuses on the heat exchanger and condenser system responsible for the cooling of the post-irradiation LBE.

36 MATERIALS SCIENCE↗

Spectroscopic investigation of electron-beam-induced excitation and ionization of air [Abstract]

Time-dependent visible and near-ultraviolet emission spectroscopy was used to track the presence of excited and ionized states induced as an electron beam transited a cavity filled with air at low pressures. An electron beam was produced in vacuum using a Febetron pulsed-power generator modified to produce a peak voltage of 100 kV, a peak current of 4.5 kA, and a pulse width of 100 ns. The beam electrons then passed through thin anode and pressure foils and transited a cavity filled with dry air at either 0.1 Torr or 1 Torr, exciting and ionizing the air along the way. The spectral measurements were combined with information from electrical, interferometric, and imaging diagnostics to reveal different ionization dynamics for the two cases under study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mo-99 Concentration and processing by Solvent Extraction and Ion Exchange

Normally derived from its transient-equilibrium parent molybdenum-99 ( 99 Mo) (t½ = 66 h), the short-lived isotope technetium-99m ( 99m Tc) (t ½ = 6.0 h) is the most widely used medical isotope in diagnostic imaging today. The National Nuclear Security Administration’s (NNSA’s) Material Management and Minimization (M3) program—established under the auspices of the American Medical Isotope Production Act—has been tasked with facilitating the work of domestic 99 Mo suppliers that do not use highly enriched uranium (HEU). Superconducting electron linear accelerators that employ high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that can induce photonuclear reactions and uranium (U) fission. Argonne, in collaboration with industrial partners, has been developing the process chemistry for superconducting linear accelerator (LINAC)-irradiated triuranium octoxide (U 3 O 8 ) targets to produce 99 Mo. In short, the process involves dissolving the irradiated targets in nitric acid, which simultaneously releases valuable fission products (xenon and iodine). After adjusting the acid concentration, producers process the feed using tri-n-butyl phosphate (TBP), then mix the raffinate derived from this extraction cycle with a phosphinic acid such as Cyanex 272 or di(2-ethylhexyl) phosphoric acid (HDEHP), which is selective for Mo (molybdenum liquid liquid extraction [MoLLE]). In the next step, a concentration column comprising an anion exchange platform is used to decontaminate the remaining fission products, generating a pure 99 Mo stream in sodium hydroxide (NaOH)/sodium chloride (NaCl).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Case Report: Differential diagnosis of hematuria in the emergency department: emphasizing double J stent-inferior vena cava fistula

Introduction Hematuria, a common clinical indicator of genitourinary tract pathology, arises from diverse etiologies including calculi, infections, malignancies, trauma, and iatrogenic causes. Initial evaluation requires hemodynamic assessment, identification of underlying causes, and urinary drainage optimization. This report highlights a rare case of iatrogenic hematuria secondary to double-J stent migration into the inferior vena cava. Case presentation A Chinese male presented with acute left flank pain and gross hematuria persisting for 4 h. Diagnostic imaging revealed a left ureteral stone, prompting double-J stent placement at a local hospital. Despite intervention, hematuria worsened, necessitating abdominal CT. Imaging identified proximal migration of the left double-J stent into the inferior vena cava, with no evidence of vascular injury. Due to concerns regarding inadequate drainage and infection risk, conservative management without catheter clamping was initiated prior to referral. Definitive treatment involved ureteroscopic stent removal under direct visualization at our institution, resulting in rapid symptom resolution. Conclusion This case emphasizes three critical clinical insights: (1) Persistent postoperative hematuria warrants consideration of iatrogenic causes, particularly following urologic device placement. (2) Imaging modalities, especially CT, are indispensable for detecting atypical stent migration. (3) Comprehensive history-taking must include prior urologic interventions to guide differential diagnosis. While double-J stent migration into major vessels remains exceptionally rare, its recognition prevents delayed management of potentially life-threatening complications. Clinicians should maintain heightened vigilance for device-related hematuria in patients with refractory symptoms post-procedurally, ensuring prompt imaging evaluation and multidisciplinary intervention when indicated.

Qi, Wenqi↗

NCTM workshop splinter session, IR thermal measurement instruments

The splinter session dealing with commercial industrial thermal measurement state-of-the-hardware had a total attendance of 15. Two papers were presented in the splinter session as follows: (1) Development of an Infrared Imaging System for the Surface Tension Driven Convection Experiment, Alexander D. Pline, NASA LeRC; (2) A Space-qualified PtSi Thermal Imaging System, Robert W. Astheimer, Barnes Engineering Div., EDO Corp. In addition a brief description of SPRITE detector technology was presented by Richard F. Leftwich of Magnovox. As anticipated, the discussions were concerned mainly with thermal imaging figures of merit rather than those for point measurement instruments. The need for uniform guidelines whereby infrared thermal imaging instruments could be specified and evaluated was identified as most important, particularly where temperature measurements are required. Presently there are differences in the way different manufacturers present significant performance parameters in their instrument data sheets. Furthermore, the prospective user has difficulty relating these parameters to actual measurement needs, and procedures by which performance can be verified are poorly defined. The current availability of powerful thermal imaging diagnostic software was discussed.

Kaplan, Herbert↗

Portable dynamic fundus instrument

A portable diagnostic image analysis instrument is disclosed for retinal funduscopy in which an eye fundus image is optically processed by a lens system to a charge coupled device (CCD) which produces recordable and viewable output data and is simultaneously viewable on an electronic view finder. The fundus image is processed to develop a representation of the vessel or vessels from the output data.

Taylor, Gerald R.↗

Overview of Photonic Materials for Application in Space Environments

Future space systems will he based on components evolving from the development and refinement of new and existing photonic materials. Optically based sensors, inertial guidance, tracking systems, communications, diagnostics, imaging and high speed optical processing are but a few of the applications expected to widely utilize photonic materials. The response of these materials to space environment effects (SEE) such as spacecraft charging, orbital debris, atomic oxygen, ultraviolet irradiation, temperature and ionizing radiation will be paramount to ensuring successful space applications. The intent of this paper is to, address the latter two environments via a succinct comparison of the known sensitivities of selected photonic materials to the temperature and ionizing radiation conditions found in space and enhanced space environments Delineation of the known temperature and radiation induced responses in LiNbO3, AlGaN, AlGsAs,TeO2, Si:Ge, and several organic polymers are presented. Photonic materials are realizing rapid transition into applications for many proposed space components and systems including: optical interconnects, optical gyros, waveguide and spatial light modulators, light emitting diodes, lasers, optical fibers and fiber optic amplifiers. Changes to material parameters such as electrooptic coefficients, absorption coefficients, polarization, conductivity, coupling coefficients, diffraction efficiencies, and other pertinent material properties examined for thermo-optic and radiation induced effect. Conclusions and recommendations provide the reader with an understanding of the limitations or attributes of material choices for specific applications.

Taylor, E. W.↗

Research to Operations: The Critical Transition

Space Life Sciences Directorate (SLSD) specializes in transitioning technology and knowledge to medical operations. This activity encompasses funding a spectrum of research and technology efforts, such as understanding fundamental biological mechanisms altered by microgravity and executing technology watches for state of the art diagnostic imaging equipment. This broad spectrum approach to fulfilling the need to protect crewmember health and performance during long and short duration missions to the International Space Station, moon and Mars is made possible by having a line of site between research and operations. Currently, SLSD's line of site is articulated in a transition to medical practice (TMP) process. This process is designed to shepherd information and knowledge gained through fundamental and mechanistic research toward the development of an operational solution such as a pre-flight selection criteria; an in-flight countermeasure, monitoring capability or treatment; or a post-flight reconditioning program. The TMP process is also designed to assist with the customization of mature hardware or technology for NASA specific use. The benefits of this process are that the concept of operational usability is interjected early in the research, design, or acquisition phase, and stakeholders are involved early to identify requirements and also periodically asked to assess requirements compliance of research or technology development project. Currently a device known as the actiwatch is being assessed for the final transition to operational use. Specific examples of research to operations transition success help to illustrate the process and bolster communication between the research and medical operations communities.

Fogarty, Jennifer A.↗