Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diameter effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The effect of growth rate, diameter and impurity concentration on structure in Czochralski silicon crystal growth

It is demonstrated that maximum growth rates of up to 80% of the theoretical limit can be attained in Czochralski-grown silicon crystals while maintaining single crystal structure. Attaining the other 20% increase is dependent on design changes in the grower, to reduce the temperature gradient in the liquid while increasing the gradient in the solid. The conclusions of Hopkins et al. (1977) on the effect of diameter on the breakdown of structure at fast growth rates are substantiated. Copper was utilized as the test impurity. At large diameters (greater than 7.5 cm), concentrations of greater than 1 ppm copper were attained in the solid (45,000 ppm in the liquid) without breakdown at maximum growth speeds. For smaller diameter crystals, the sensitivity of impurities is much more apparent. For solar cell applications, impurities will limit cell performance before they cause crystal breakdown for fast growth rates of large diameter crystals.

Digges, T. G., Jr.↗

Effects of Limiting Container Diameter on Crater Morphometry in Laboratory Impact Experiments.

Laboratory impact experiments provide a mechanism to test and understand impact events that affect every planetary object in our Solar System. Impact experiments have been conducted on a wide variety of mediums (e.g., sand, ice, solid rock, regolith simulant [1–4]) in a variety of container sizes, depending on the laboratory. While the specific parameters of each impact experiment vary greatly from impacting medium, projectile type and size, speed, etc., there has not been any in depth analysis of the effects that limiting container dimensions might have on the resulting subsurface flow field and ultimately the crater structure. Here we asses the effects of container diameter by conducting a series of cratering experiments on five different container sizes. The results of this study will be informative to the impact community such that closer consideration will be taken regarding the selection of container size to insure the most high quality results with less interference from the boundary conditions.

Megan D. Mouser↗

Length to diameter ratio and row number effects in short pin fin heat transfer

The relative effects of pin length to diameter ratio and of pin row geometry on the heat transfer from pin fins, was determined. Array averaged heat transfer coefficients on pin and endwall surfaces were measured for two configurations of staggered arrays of short pin fins (length to diameter ratio of 4). One configuration contained eight streamwise rows of pins, while the other contained only four rows. Results showed that both the 8-row and the 4-row configurations for an L sub p/D of 4, exhibit higher heat transfer than in similar tests on shorter pin fns (L sub p/D of 1/2 and 2). It was also found that for this L sub p/D ratio, the array averaged heat transfer was slightly higher with eight rows of staggered pins than with only four rows.

Brigham, B. A.↗

Length to diameter ratio and row number effects in short pin fin heat transfer

The relative effects of pin length to diameter ratio and of pin row geometry on the heat transfer from pin fins, was determined. Array averaged heat transfer coefficients on pin and endwall surfaces were measured for two configurations of staggered arrays of short pin fins (length to diameter ratio of 4). One configuration contained eight streamwise rows of pins, while the other contained only four rows. Results showed that both the 8-row and the 4-row configurations for an L sub p/D of 4, exhibit higher heat transfer than in similar tests on shorter pin fins (L sub p/D of 1/2 and 2). It was also found that for this L sub p/D ratio, the array averaged heat transfer was slightly higher with eight rows of staggered pins than with only four rows. Previously announced in STAR as N83-14431

Brigham, B. A.↗

Effect of reduced aft diameter and increased blade number on high-speed counterrotation propeller performance

Performance data of 0.17-scale model counterrotation pusher propeller configurations were taken in the NASA Lewis 8- by 6-Foot Supersonic Wind Tunnel at Mach numbers of 0.66, 0.71, 0.75, and 0.79. These tests investigated the aerodynamic performance of the unducted fan (UDF) demonstrator propeller engine developed in a joint program by General Electric and NASA. Data were recorded to show the effect on counterrotation propeller cruise efficiency of two takeoff noise-reduction concepts. These two concepts are reduced aft blade diameter and increased forward blade number. The four configurations tested were a baseline (F1/A1 8/8) configuration, a reduced aft diameter (F1/A3 8/8) configuration, an increase forward blade number (F1/A1 9/8) configuration, and a combination of the latter two (F1/A3 9/8) configurations. Data were collected with a complex counterrotation propeller test rig via rotating thrust and torque balances and pressure instrumentation. Data comparisons documented the power differences between the baseline and the reduced aft diameter concepts. Performance comparisons to the baseline configuration showed that reducing the aft blade diameter reduced the net efficiency, and adding a blade to the front rotor increased the net efficiency. The combination of the two concepts showed only slightly lower net efficiency than the baseline configuration. It was also found that the counterrotation demonstrator propeller model (F7/A7 8/8) configuration outperformed the baseline (F1/A1 8/8) configuration.

Rose, Gayle E.↗

Effect of reduced aft diameter and increased blade number of high-speed counterrotation propeller performance

Performance data of 0.17-scale model counterrotation pusher propeller configurations were taken in the NASA Lewis 8- by 6-Foot Supersonic Wind Tunnel at Mach numbers of 0.66, 0.71, 0.75, and 0.79. These tests investigated the aerodynamic performance of the unducted fan (UDF) demonstrator propeller engine developed in a joint program by General Electric and NASA. Data were recorded to show the effect on counterrotation propeller cruise efficiency of two takeoff noise-reduction concepts. These two concepts are reduced aft blade diameter and increased forward blade number. The four configurations tested were a baseline (F1/A1 8/8) configuration, a reduced aft diameter (F1/A3 8/8) configuration, an increase forward blade number (F1/A1 9/8) configuration, and a combination of the latter two (F1/A3 9/8) configurations. Data were collected with a complex counterrotation propeller test rig via rotating thrust and torque balances and pressure instrumentation. Data comparisons documented the power differences between the baseline and the reduced aft diameter concepts. Performance comparisons to the baseline configuration showed that reducing the aft blade diameter reduced the net efficiency, and adding a blade to the front rotor increased the net efficiency. The combination of the two concepts showed only slightly lower net efficiency than the baseline configuration. It was also found that the counterrotation demonstrator propeller model (F7/A7 8/8) configuration outperformed the baseline (F1/A1 8/8) configuration.

Gayle, E. Rose↗

Effect of orifice length-diameter ratio on fuel sprays for compression-ignition engines

Experimental results on the effect of the length-diameter ratio of the orifice on the spray characteristics, together with a brief analysis of the factors affecting these characteristics, are presented in this report. The length-diameter ratios tested ranged from 0.5 to 10; the orifice diameters from 0.008 to 0.040 inch; and the injection pressures from 2,000 to 8,000 pounds per square inch. The density of the air into which the fuel was discharged was varied from 0.38 to 1.35 pounds per cubic foot.

Gelalles, A G↗

Effects of Sting-Support Diameter on the Base Pressures of an Elliptic Cone at Mach Numbers from 0.60 to 1.40

Measurements were made to determine the effects of sting-support diameter on the base pressures of an elliptic cone with ratio of cross-section thickness to width of 1/3 and a plan-form, semi-apex angle of 15 deg. The investigation was made for model angles of attack from -2 deg to +20 deg at Mach numbers from 0.60 to 1.40, and for a constant Reynolds number of 1.4 million, based on the length of the model. The results indicated that the sting interference decreased the base axial-force coefficients by substantial amounts up to a maximum of about one-third the value of the coefficient for no sting interference. There was no practical diameter of the sting for which the effects of the sting on the base pressures would be negligible throughout the Mach number and angle-of-attack ranges of the investigation.

Stivers, Louis S., Jr.↗

An experimental study of high-pressure droplet combustion

The results are presented of an experimental study on suspended n-heptane droplet combustion in air for reduced pressures up to P(r) = 2.305. Transition to fully transient heat-up through the critical state is demonstrated above a threshold pressure corresponding to P(r) of roughly 1.4. A silhouette imaging technique resolves the droplet surface for reduced pressures up to about P(r) roughly 0.63, but soot formation conceals the surface at higher pressures. Images of the soot plumes do not show any sudden change in behavior indicative of critical transition. Mean burning rate constants are computed from the d-squared variation law using measured effective droplet diameters at ignition and measured burn times, and corrected burning times are computed for an effective initial droplet diameter. The results show that the burning rates increase as the fuel critical pressure is approached and decrease as the pressure exceeds the fuel critical pressure. Corrected burning times show inverse behavior.

Norton, Chris M.↗

The effect of length and diameter on the resistivity of bromine intercalated graphite fibers

The resistivity of bromine intercalated graphite fibers has been shown to vary with both the diameter and the length of the fibers. This is due to bromine depletion from the fiber surface. Model calculations assuming a 1.0 micron bromine depletion zone for P-100, and 3.0 microns for vapor-grown graphite fibers fit the respective diameter dependence of their resistivities quite well. Length dependence data imply a bromine depletion zone along the length of P-100 fibers which is also a few microns, but that of vapor grown fibers appears to be as large as 300 microns. Despite these values, microfilaments, which are much smaller than the expected depletion zones, do form residual bromine intercalation compounds with resistivities about one-half of their pristine value.

Gaier, James R.↗

Demonstration of a MOT in a sub-millimeter membrane hole

Abstract We demonstrate the generation of a cold-atom ensemble within a sub-millimeter diameter hole in a transparent membrane, a so-called “membrane MOT”. With a sub-Doppler cooling process, the atoms trapped by the membrane MOT are cooled down to 10 $$\upmu$$ μ K. The atom number inside the unbridged/bridged membrane hole is about $$10^4$$ 10 4 to $$10^5$$ 10 5 , and the $$1/e^2$$ 1 / e 2 -diameter of the MOT cloud is about 180 $$\upmu$$ μ m for a 400 $$\upmu$$ μ m-diameter membrane hole. Such a membrane device can, in principle, efficiently load cold atoms into the evanescent-field optical trap generated by the suspended membrane waveguide for strong atom-light interaction and provide the capability of sufficient heat dissipation at the waveguide. This represents a key step toward the photonic atom trap integrated platform (ATIP).

74 ATOMIC AND MOLECULAR PHYSICS↗

Heat Transfer from High-Temperature Surfaces to Fluids III - Correlation of Heat-Transfer Data for Air Flowing in Silicon Carbide Tube with Rounded Entrance, Inside Diameter of 3/4 Inch, and Effective Length of 12 Inches

A heat-transfer investigation was conducted with air flowing through an electrically heated silicon carbide tube with a rounded entrance, an inside diameter of 3/4 inch, and effective heat-transfer length of 12 inches over a range of Reynolds numbers up to 300,000 and a range of average inside-tube-wall temperatures up to 2500 R. The highest corresponding local outside-tube-wall temperature was 3010 R.

Sams, Eldon W.↗

Photogrammetric Analysis of CPAS Main Parachutes

The Crew Exploration Vehicle Parachute Assembly System (CPAS) is being designed to land the Orion Crew Module (CM) at a safe rate of descent at splashdown with a cluster of two to three Main parachutes. The instantaneous rate of descent varies based on parachute fly-out angles and geometric inlet area. Parachutes in a cluster oscillate between significant fly-out angles and colliding into each other. The former presents a sub-optimal inlet area and the latter lowers the effective drag area as the parachutes interfere with each other. The fly-out angles are also important in meeting a twist torque requirement. Understanding cluster behavior necessitates measuring the Mains with photogrammetric analysis. Imagery from upward looking cameras is analyzed to determine parachute geometry. Fly-out angles are measured from each parachute vent to an axis determined from geometry. Determining the scale of the objects requires knowledge of camera and lens calibration as well as features of known size. Several points along the skirt are tracked to compute an effective circumference, diameter, and inlet area as a function of time. The effects of this geometry are clearly seen in the system drag coefficient time history. Photogrammetric analysis is key in evaluating the effects of design features such as an Over-Inflation Control Line (OICL), Main Line Length Ratio (MLLR), and geometric porosity, which are varied in an attempt to minimize cluster oscillations. The effects of these designs are evaluated through statistical analysis.

Ray, Eric↗