Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Goddard Space Flight Center's Structural Dynamics Data Acquisition System

Turnkey Commercial Off The Shelf (COTS) data acquisition systems typically perform well and meet most of the objectives of the manufacturer. The problem is that they seldom meet most of the objectives of the end user. The analysis software, if any, is unlikely to be tailored to the end users specific application; and there is seldom the chance of incorporating preferred algorithms to solve unique problems. Purchasing a customized system allows the end user to get a system tailored to the actual application, but the cost can be prohibitive. Once the system has been accepted, future changes come with a cost and response time that's often not workable. When it came time to replace the primary digital data acquisition system used in the Goddard Space Flight Center's Structural Dynamics Test Section, the decision was made to use a combination of COTS hardware and in-house developed software. The COTS hardware used is the DataMAX II Instrumentation Recorder built by R.C. Electronics Inc. and a desktop Pentium 4 computer system. The in-house software was developed using MATLAF3 from The Mathworks. This paper will describe the design and development of the new data acquisition and analysis system.

McLeod, Christopher↗

Goddard Space Flight Center's Structural Dynamics Data Acquisition System

Turnkey Commercial Off The Shelf (COTS) data acquisition systems typically perform well and meet most of the objectives of the manufacturer. The problem is that they seldom meet most of the objectives of the end user. The analysis software, if any, is unlikely to be tailored to the end users specific application; and there is seldom the chance of incorporating preferred algorithms to solve unique problems. Purchasing a customized system allows the end user to get a system tailored to the actual application, but the cost can be prohibitive. Once the system has been accepted, future changes come with a cost and response time that's often not workable. When it came time to replace the primary digital data acquisition system used in the Goddard Space Flight Center's Structural Dynamics Test Section, the decision was made to use a combination of COTS hardware and in-house developed software. The COTS hardware used is the DataMAX II Instrumentation Recorder built by R.C. Electronics Inc. and a desktop Pentium 4 computer system. The in-house software was developed using MATLAB from The MathWorks. This paper will describe the design and development of the new data acquisition and analysis system.

McLeod, Christopher↗

Overview and first measurements of the MAST Upgrade bolometer diagnostic

Here, a suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

47 OTHER INSTRUMENTATION↗

Development of digital electronics for the search of SHE nuclei using GARIS-II/III at RIKEN

This work describes the implementation of a digital data acquisition system for the search and study of short-lived isotopes or superheavy elements at the GARIS-III separator at the RIKEN Nishina Center. Here a reduction to 26 ± 0.5 keV in the average value of the Full Width at Half Maximum of the alpha spectrum at 7.133 MeV was achieved, combined with a reduction of the dead time of the overall system to around a few tens of nanoseconds for the detection of very fast decay chains. Moreover, we measured a reduction of the background induced by particles crossing the implantation detector using pulse shape analysis techniques. The detail of the optimization and analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed digitization readout of silicon photomultipliers for time of flight positron emission tomography

We report on work to develop a system with about 100 picoseconds (ps) time resolution for time of flight positron emission tomography [TOF-PET]. The chosen photo detectors for the study were Silicon Photomultipliers (SiPM's). This study was based on extensive experience in studying timing properties of SiPM's. The readout of these devices used the commercial high speed digitizer DRS4. We applied different algorithms to get the best time resolution of 155 ps Guassian (sigma) for a LYSO crystal coupled to a SiPM. We consider the work as a first step in building a prototype TOF-PET module. The field of positron-emission-tomography (PET) has been rapidly developing. But there are significant limitations in how well current PET scanners can reconstruct images, related to how fast data can be acquired, how much volume they can image, and the spatial and temporal resolution of the generated photons. Typical modern scanners now include multiple rings of detectors, which can image a large volume of the patient. In this type of scanner, one can treat each ring as a separate detector and require coincidences only within the ring, or treat the entire region viewed by the scanner as a single 3 dimensional volume. This 3d technique has significantly better sensitivity since more photon pair trajectories are accepted. However, the scattering of photons within the volume of the patient, and the effect of random coincidences limits the technique. The advent of sub-nanosecond timing resolution detectors means that there is potentially much better rejection of scattered photon events and random coincidence events in the 3D technique. In addition, if the timing is good enough, then the origin of photons pairs can be determined better, resulting in improved spatial resolution - so called 'Time-of-Flight' PET, or TOF-PET. Currently a lot of activity has occurred in applications of SiPMs for TOF-PET. This is due to the devices very good time resolution, low profile, lack of high voltage needed, and their non-sensitivity to magnetic fields. While investigations into this technique have begun elsewhere, we feel that the extensive SiPM characterization and data acquisition expertise of Fermilab, and the historical in-depth research of PET imaging at University of Chicago will combine to make significant strides in this field. We also benefit by a working relationship with the SiPM producer STMicroelectronics (STM).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reliable and redundant FPGA based read-out design in the ATLAS TileCal Demonstrator

The Tile Calorimeter at ATLAS [1] is a hadron calorimeter based on steel plates and scintillating tiles read out by PMTs. The current read-out system uses standard ADCs and custom ASICs to digitize and temporarily store the data on the detector. However, only a subset of the data is actually read out to the counting room. The on-detector electronics will be replaced around 2023. To achieve the required reliability the upgraded system will be highly redundant. Here the ASICs will be replaced with Kintex-7 FPGAs from Xilinx. This, in addition to the use of multiple 10 Gbps optical read-out links, will allow a full read-out of all detector data. Due to the higher radiation levels expected when the beam luminosity is increased, opportunities for repairs will be less frequent. The circuitry and firmware must therefore be designed for sufficiently high reliability using redundancy and radiation tolerant components. Within a year, a hybrid demonstrator including the new readout system will be installed in one slice of the ATLAS Tile Calorimeter. This will allow the proposed upgrade to be thoroughly evaluated well before the planned 2023 deployment in all slices, especially with regard to long term reliability. Different firmware strategies alongside with their integration in the demonstrator are presented in the context of high reliability protection against hardware malfunction and radiation induced errors.

ATLAS↗

Staff Radiation Doses in a Real-Time Display Inside the Angiography Room

MethodsThe evaluation of a new occupational Dose Aware System (DAS) showing staff radiation doses in real time has been carried out in several angiography rooms in our hospital. The system uses electronic solid-state detectors with high-capacity memory storage. Every second, it archives the dose and dose rate measured and is wirelessly linked to a base-station screen mounted close to the diagnostic monitors. An easy transfer of the values to a data sheet permits further analysis of the scatter dose profile measured during the procedure, compares it with patient doses, and seeks to find the most effective actions to reduce operator exposure to radiation.ResultsThe cumulative occupational doses measured per procedure (shoulder-over lead apron) ranged from 0.6 to 350 {mu}Sv when the ceiling-suspended screen was used, and DSA (Digital Subtraction Acquisition) runs were acquired while the personnel left the angiography room. When the suspended screen was not used and radiologists remained inside the angiography room during DSA acquisitions, the dose rates registered at the operator's position reached up to 1-5 mSv/h during fluoroscopy and 12-235 mSv/h during DSA acquisitions. In such case, the cumulative scatter dose could be more than 3 mSv per procedure.ConclusionReal-time display of doses to staff members warns interventionists whenever the scatter dose rates are too high or the radiation protection tools are not being properly used, providing an opportunity to improve personal protection accordingly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Information barrier experimental: Toward a trusted and open-source computing platform for nuclear warhead verification

Trusted measurement systems are critical for the verification of future arms-control treaties that involve confirming the authenticity of nuclear warheads on the basis of their radiation signatures. Several research efforts have produced prototype systems, but their designs are typically not published in detail, making it difficult to enable trust in these devices. The Information Barrier Experimental (IBX) is a new prototype built around the Red Pitaya computing platform using passive gamma spectroscopy. It is the first such platform designed to help a broad research community study vulnerabilities and define the required specifications for a common, trusted inspection system. It is low-cost, simple to assemble, and enables comprehensive hardware and software authentication studies. The device follows a digital data acquisition approach, which significantly reduces the number of components between scintillator and spectrum output. Finally, measurements demonstrate that this approach is technically feasible and produces excellent measurement results.

97 MATHEMATICS AND COMPUTING↗

Source characterization of a detector for heavy and superheavy nuclei

A new focal plane detector system for the Berkeley Gas-filled Separator (BGS) was designed, constructed, and tested offline with various α-decay and conversion-electron sources. The SuperHeavy RECoils (SHREC) detector comprises sets of double-sided silicon strip detectors arranged in an open-faced cuboid geometry. Alongside the detector upgrade new digital data acquisition electronics have been commissioned offline. This setup aims to detect separated recoiling heavy and superheavy nuclei as well as their correlated radioactive decay paths with improved energy resolution and overall sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Capture and Transmission Measurements of 54 Fe at the RPI LINAC

54 Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54 Fe sample in the keV energy region. 54 Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54 Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C 6 D 6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54 Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54 Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54 Fe up to roughly 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ITER Radial Neutron Camera Detection System

A multichannel neutron detection system (Radial Neutron Camera, RNC) will be installed on the ITER equatorial port plug 1 for total neutron source strength, neutron emissivity/ion temperature profiles and n{sub t}/n{sub d} ratio measurements [1]. The system is composed by two fan shaped collimating structures: an ex-vessel structure, looking at the plasma core, containing tree sets of 12 collimators (each set lying on a different toroidal plane), and an in-vessel structure, containing 9 collimators, for plasma edge coverage. The RNC detecting system will work in a harsh environment (neutron fiux up to 10{sup 8}-10{sup 9} n/cm{sup 2} s, magnetic field >0.5 T or in-vessel detectors), should provide both counting and spectrometric information and should be flexible enough to cover the high neutron flux dynamic range expected during the different ITER operation phases. ENEA has been involved in several activities related to RNC design and optimization [2,3]. In the present paper the up-to-date design and the neutron emissivity reconstruction capabilities of the RNC will be described. Different options for detectors suitable for spectrometry and counting (e.g. scintillators and diamonds) focusing on the implications in terms of overall RNC performance will be discussed. The increase of the RNC capabilities offered by the use of new digital data acquisition systems will be also addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma ray spectroscopy at high energy and high time resolution at JET

In fusion plasmas gamma ray emission is caused by reactions of fast particles, such as fusion alpha particles, with impurities. Gamma ray spectroscopy at JET has provided valuable diagnostic information on fast fuel as well as fusion product ions. Improvements of these measurements are needed to fully exploit the flux increase provided by future high power experiments at JET and ITER. Limiting aspects are, for instance, the count rate capability due to a high neutron/gamma background combined with slow detector response and a modest energy resolution due to the low light yield of the scintillators. This paper describes the solutions developed for achieving higher energy resolution, signal to background, and time resolution. The detector design is described based on the new BrLa{sub 3} scintillator crystal. The paper will focus on hardware development, including a photomultiplier tube capable of stable operation at counting rate as high as 1 MHz, the magnetic shielding, and the fast digital data acquisition system.

36 MATERIALS SCIENCE↗

Performance of an AGATA asymmetric detector

Each major technical advance in gamma-ray detection devices has resulted in significant new insights into the structure of atomic nuclei. The next major step in gamma-ray spectroscopy involves achieving the goal of a 4{pi} ball of germanium detectors by using the technique of gamma-ray energy tracking in electrically segmented germanium crystals. The resulting spectrometer will have an unparalleled level of detection power for nuclear electromagnetic radiation. Collaborations have been established in Europe (AGATA)[1] and the USA (GRETA/GRETINA)[2] to build gamma-ray tracking spectrometers. This paper discusses the performance of the first AGATA (Advanced GAmma Tracking Array) asymmetric detector that has been tested at the University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and Performance of an AGATA asymmetric detector

High-resolution gamma-ray detectors based on high-purity germanium crystals (HPGe) are one of the key workhorses of experimental nuclear science. The technical development of such detector technology has been dramatic in recent years. Large volume, high-granularity, electrically segmented HPGe detectors have been realised and a methodology to improve position sensitivity using pulse-shape analysis coupled with the novel technique of gamma-ray tracking has been developed. Collaborations have been established in Europe (AGATA)[1] and the USA (GRETA/GRETINA)[2] to build gamma-ray tracking spectrometers. This paper discusses the performance of the first AGATA (Advanced GAmma Tracking Array) asymmetric detector that has been tested at the University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed digital holography for density and fluctuation measurements (invited)

The state of the art in electro-optics has advanced to the point where digital holographic acquisition of wavefronts is now possible. Holographic wavefront acquisition provides the phase of the wavefront at every measurement point. This can be done with accuracy on the order of a thousandth of a wavelength, given that there is sufficient care in the design of the system. At wave frequencies which are much greater than the plasma frequency, the plasma index of refraction is linearly proportional to the electron density and wavelength, and the measurement of the phase of a wavefront passing through the plasma gives the chord-integrated density directly for all points measured on the wavefront. High-speed infrared cameras (up to {approx}40 000 fps at {approx}64x4 pixels) with resolutions up to 640x512 pixels suitable for use with a CO{sub 2} laser are readily available, if expensive.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation Of Exotic Shapes, Correlations And Isomers In Nuclei With Large Compton Suppressed Clover Array

An array is designed for 24 Compton suppressed clover detectors. Recent results from the array will be presented which highlights the structure of nuclei in A {approx} 110 and 130 region and investigation of different reactions dynamics. The perspectives offered by the forthcoming operation of the clover array coupled to a new digital data acquisition system are also discussed briefly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{gamma}-ray measurements and neutron sensitivity in a fusion environment

A system based on a LaBr{sub 3}(Ce) scintillator and digital data acquisition is discussed in view of {gamma}-ray spectroscopy measurements on a fusion burning plasma. High energy resolution and high rate capability of the system are demonstrated in laboratory tests and in dedicated experiments at nuclear accelerators. Preliminary results on sensitivity of the detector to 14 MeV neutrons are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear structure studies with INGA coupled to a fast DDAQ

Studies of different types of nuclear excitation and isomers remain the main thrust area of the last experimental campaign using INGA at TIFR-BARC Pelletron Linac Facility at Mumbai. A digital data acquisition system has been coupled with the INGA which has improved the data throughput and better gain stability. About forty experiments that have been proposed in this experimental campaign. Selected results from these experiments will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗