Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Time Protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advanced information processing system: Authentication protocols for network communication

In safety critical I/O and intercomputer communication networks, reliable message transmission is an important concern. Difficulties of communication and fault identification in networks arise primarily because the sender of a transmission cannot be identified with certainty, an intermediate node can corrupt a message without certainty of detection, and a babbling node cannot be identified and silenced without lengthy diagnosis and reconfiguration . Authentication protocols use digital signature techniques to verify the authenticity of messages with high probability. Such protocols appear to provide an efficient solution to many of these problems. The objective of this program is to develop, demonstrate, and evaluate intercomputer communication architectures which employ authentication. As a context for the evaluation, the authentication protocol-based communication concept was demonstrated under this program by hosting a real-time flight critical guidance, navigation and control algorithm on a distributed, heterogeneous, mixed redundancy system of workstations and embedded fault-tolerant computers.

Harper, Richard E.↗

Using Social Media and Mobile Devices to Discover and Share Disaster Data Products Derived From Satellites

Data products derived from Earth observing satellites are difficult to find and share without specialized software and often times a highly paid and specialized staff. For our research effort, we endeavored to prototype a distributed architecture that depends on a standardized communication protocol and applications program interface (API) that makes it easy for anyone to discover and access disaster related data. Providers can easily supply the public with their disaster related products by building an adapter for our API. Users can use the API to browse and find products that relate to the disaster at hand, without a centralized catalogue, for example floods, and then are able to share that data via social media. Furthermore, a longerterm goal for this architecture is to enable other users who see the shared disaster product to be able to generate the same product for other areas of interest via simple point and click actions on the API on their mobile device. Furthermore, the user will be able to edit the data with on the ground local observations and return the updated information to the original repository of this information if configured for this function. This architecture leverages SensorWeb functionality [1] presented at previous IGARSS conferences. The architecture is divided into two pieces, the frontend, which is the GeoSocial API, and the backend, which is a standardized disaster node that knows how to talk to other disaster nodes, and also can communicate with the GeoSocial API. The GeoSocial API, along with the disaster node basic functionality enables crowdsourcing and thus can leverage insitu observations by people external to a group to perform tasks such as improving water reference maps, which are maps of existing water before floods. This can lower the cost of generating precision water maps. Keywords-Data Discovery, Disaster Decision Support, Disaster Management, Interoperability, CEOS WGISS Disaster Architecture

Spitzer Microlensing Parallax for OGLE-2016-BLG-1067: A Sub-Jupiter Orbiting an M Dwarf in the Disk

We report the discovery of a sub-Jupiter-mass planet orbiting beyond the snow line of an M dwarf most likely in the Galactic disk as part of the joint Spitzer and ground-based monitoring of planetary microlensing anomalies toward the Galactic bulge. Most of the microlensing parameters are strongly constrained by the light-curve modeling, and in particular there is a Spitzer-based measurement of the microlens parallax, π(E). However, there are no caustic crossings, so the angular Einstein radius has only an upper limit based on the light-curve modeling alone. Additionally, the analysis leads us to identify eight degenerate configurations: the fourfold microlensing parallax degeneracy being doubled by a degeneracy in the caustic structure present at the level of the ground-based solutions. To calculate the physical parameters, and at the same time to break the parallax degeneracy, we make use of a series of arguments: the χ(exp 2) hierarchy, the Rich argument (stating that the small-parallax solution is more likely), and a prior Galactic model. The preferred configuration, favored by a likelihood ratio of at least 4000, is for a host at D(L)={3.73}(-0.67+0.66)kpc with mass M(L)=0.30(-0.12+0.15) M(☉) , orbited by a Saturn-like planet with M(planet) =0.43(-0.17+0.21) M(Jup) at projected separation a(⊥) =1.70(-0.39+0.38) au, about 2.1 times beyond the system snow line. Therefore, it adds to the growing population of sub-Jupiter planets orbiting beyond the snow line of M dwarfs discovered by microlensing. Based on the rules of the real-time protocol for the selection of events to be followed up with Spitzer, this planet will not enter the sample for measuring the Galactic distribution of planets.

S. Calchi Novati↗

EMS and DMS Integration of the Coordinative Real-time Sub-Transmission Volt-Var Control Tool under High DER Penetration

This paper proposes an applicable approach to deploy the Coordinative Real-time Sub-Transmission Volt-Var Control Tool (CReST-VCT), and a holistic system integration framework considering both the energy management system (EMS) and distribution system management system (DMS). This provides an architectural basis and can serve as the implementation guideline of CReST-VCT and other advanced grid support tools, to co-optimize the operation benefits of DERs and assets in both transmission and distribution networks. Potential communication protocols for different physical domains of a real application is included. Performance and security issues are also discussed, along with specific considerations for field deployment. Finally, the paper presents a viable pathway for CReST-VCT and other advanced grid support tools, which could be integrated in an open-source standardized-based platform that supports distribution utilities.

Nguyen, Quan H.↗

The multidriver: A reliable multicast service using the Xpress Transfer Protocol

A reliable multicast facility extends traditional point-to-point virtual circuit reliability to one-to-many communication. Such services can provide more efficient use of network resources, a powerful distributed name binding capability, and reduced latency in multidestination message delivery. These benefits will be especially valuable in real-time environments where reliable multicast can enable new applications and increase the availability and the reliability of data and services. We present a unique multicast service that exploits features in the next-generation, real-time transfer layer protocol, the Xpress Transfer Protocol (XTP). In its reliable mode, the service offers error, flow, and rate-controlled multidestination delivery of arbitrary-sized messages, with provision for the coordination of reliable reverse channels. Performance measurements on a single-segment Proteon ProNET-4 4 Mbps 802.5 token ring with heterogeneous nodes are discussed.

Dempsey, Bert J.↗

Survival After Accidental Extrahepatic Distribution of Y90 Microspheres to the Mesentery During a Radioembolization Procedure

We present the acute management and outcome of a patient after an accidental mesenteric distribution of Y90 microspheres during radioembolization (RE). This report describes and highlights: (1) the incidence of a significant reflux during a RE session while injecting into a replaced right hepatic artery from the superior mesenteric artery, (2) the appearance of diffuse mesenteric Y90 distribution in bremsstrahlung-imaging, (3) the management protocol with the radiation protection agent amifostine, (4) the development of typical adverse effects in the expected time window, and (5) survival of the patient without long-term sequelae. This report should sensitize physicians to this particular problem and may help to avoid as well as manage similar radioembolization incidences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comments on the "Byzantine Self-Stabilizing Pulse Synchronization" Protocol: Counter-examples

Embedded distributed systems have become an integral part of many safety-critical applications. There have been many attempts to solve the self-stabilization problem of clocks across a distributed system. An analysis of one such protocol called the Byzantine Self-Stabilizing Pulse Synchronization (BSS-Pulse-Synch) protocol from a paper entitled "Linear Time Byzantine Self-Stabilizing Clock Synchronization" by Daliot, et al., is presented in this report. This report also includes a discussion of the complexity and pitfalls of designing self-stabilizing protocols and provides counter-examples for the claims of the above protocol.

Malekpour, Mahyar R.↗

Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer

Purpose: To compare contribution and accuracy of delivery for two flattening filter free (FFF) beams of the nominal energy 6 and 10 MV and a 6 MV flattened beam for early stage lung cancer. Methods: For each of 11 patients with stage I nonsmall cell lung cancer three volumetric modulated arc therapy plans were prepared utilizing a 6 MV flattened photon beam (X6FF) and two nonflattened beams of nominal energy 6 and 10 MV (X6FFF, X10FFF). Optimization constraints were set to produce dose distributions that meet the criteria of the RTOG-0915 protocol. The radiation schedule used for plan comparison in all patients was 50 Gy in five fractions. Dosimetric parameters of planning target volume (PTV) and organs-at-risk and delivery times were assessed and compared. All plans were subject to verification using Delta{sup 4} unit (Scandidos, Sweden) and absolutely calibrated gafchromic films in a thorax phantom. Results: All plans had a qualitatively comparable outcome. Obtained dose distributions were conformal (CI < 1.17) and exhibited a steep dose fall-off outside the PTV. The ratio of monitor units for FFF versus FF plans in the authors' study ranged from 0.95 to 1.21 and from 0.93 to 1.25 for X6FFF/X6FF and X10FFF/X6FF comparisons, respectively. The ratio systematically increased with increasing size of the PTV (up to +25% for 150 cm{sup 3} PTV). Yet the integral dose to healthy tissue did not follow this trend. Comparison of cumulative dose volume histograms for a patient's body showed that X6FFF plans exhibit improved conformity and reduced the volume of tissue that received more than 50% of the prescription dose. Parameters related to dose gradient showed statistically significant improvement. CI{sub 50%}, CI{sub 60%}, CI{sub 80%}, and CI{sub 100%} were on average reduced by 4.6% (p < 0.001), 4.6% (p = 0.002), 3.1% (p = 0.002), and 1.2% (p = 0.039), respectively. Gradient measure was on average reduced by 4.2% (p < 0.001). Due to dose reduction in the surrounding lung tissue, the V{sub 20} {sub Gy} and V{sub 12.5} {sub Gy} were reduced by 5.5% (p = 0.002) and 4.5% (p < 0.001). These dosimetric improvements in the fall-off were not observed for the X10FFF plans. Differences in sparing of normal tissues were not found to be statistically significant for either of the two FFF beams. Mean beam-on times were 111 s (2SD = 11 s) for X10FFF, 128 s (2SD = 19 s) for X6FFF, and X6FF plans required on average 269 s (2SD = 71 s). While the mean dose rate was 1555 ± 264 and 1368 ± 63 MU/min, for X10FFF and X6FFF, plans using the conventional X6FF were delivered with the constant maximum dose rate of 600 MU/min. Verification of all plans showed acceptable and comparable results for all plans in homogeneous as well as heterogeneous phantoms. Mean GS (3%, 2 mm) using the Delta{sup 4} phantom were 98.9% (2SD = 3.2%), 99.2% (2SD = 2.3%), and 99.2% (2SD = 2.3%) for X6FFF, X6FF, and X10FFF modalities. Verification using a thorax phantom showed GS > 98% in all cases. Conclusions: The use of FFF beams for stereotactic radiation therapy of nonsmall cell lung cancer patients yielded dose distributions qualitatively comparable to flattened beams and significantly reduced treatment delivery time. Utilizing the X6FFF beam improved conformity of dose distribution. On the other hand, X10FFF beam offered a slight improvement in treatment efficiency, and lower skin and peripheral dose. All effects were relatively small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Byzantine-fault tolerant self-stabilizing protocol for distributed clock synchronization systems

A rapid Byzantine self-stabilizing clock synchronization protocol that self-stabilizes from any state, tolerates bursts of transient failures, and deterministically converges within a linear convergence time with respect to the self-stabilization period. Upon self-stabilization, all good clocks proceed synchronously. The Byzantine self-stabilizing clock synchronization protocol does not rely on any assumptions about the initial state of the clocks. Furthermore, there is neither a central clock nor an externally generated pulse system. The protocol converges deterministically, is scalable, and self-stabilizes in a short amount of time. The convergence time is linear with respect to the self-stabilization period.

Malekpour, Mahyar R.↗

Flow of Fluid and Particle Assemblages in Rotating Systems

NASA-designed bioreactors have been highly successful in growing three-dimensional tissue structures in a low shear environment both on earth and in space. The goal of the present study is to characterize the fluid flow environment within the HFB-S bioreactor and determine the spatial distribution of particles that mimic cellular tissue structures. The results will be used to obtain optimal operating conditions of rotation rates and media perfusehnfuse rates which are required for cell culture growth protocols. Two types of experiments have been performed so far. First, we have performed laser florescent dye visualization of the perfusion loop to determine the mixing times within the chamber. The second type of experiments involved particles which represent cellular tissue to determine the spatial distribution with the chamber. From these experiments we established that mixing times were largely dependant on the speed ratio and sign of the difference between the spinner and the dome. The shortest mixing times occurred when the spinner rotates faster than the dome and longest mixing times occurs with no relative motion between the dome and spinner. Also, we have determined the spatial and temporal distribution of particle assemblages within the chamber.

Kizito, John↗

A Broadly Adaptive Array of Dose-Constraint Templates for Planning of Intensity-Modulated Radiation Therapy for Advanced T-Stage Nasopharyngeal Carcinoma

Purpose: To develop and validate adaptive dose-constraint templates in intensity-modulated radiotherapy (IMRT) planning for advanced T-stage nasopharyngeal carcinoma (NPC). Method and Materials: Dose-volume histograms of clinically approved plans for 20 patients with advanced T-stage NPC were analyzed, and the pattern of distribution in relation to the degree of overlap between targets and organs at risk (OARs) was explored. An adaptive dose constraint template (ADCT) was developed based on the degree of overlap. Another set of 10 patients with advanced T-stage NPC was selected for validation. Results of the manual arm optimization protocol and the ADCT optimization protocol were compared with respect to dose optimization time, conformity indices, multiple-dose end points, tumor control probability, and normal tissue complication probability. Results: For the ADCT protocol, average time required to achieve an acceptable plan was 9 minutes, with one optimization compared with 94 minutes with more than two optimizations of the manual arm protocol. Target coverage was similar between the manual arm and ADCT plans. A more desirable dose distribution in the region of overlap between planning target volume and OARs was achieved in the ADCT plan. Dose end points of OARs were similar between the manual arm and ADCT plans. Conclusions: With the developed ADCT, IMRT treatment planning becomes more efficient and less dependent on the planner's experience on dose optimization. The developed ADCT is applicable to a wide range of advanced T-stage NPC treatment and has the potential to be applied in a broader context to IMRT planning for other cancer sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Distributed Simulation Facility to Support Human Factors Research in Advanced Air Transportation Technology

A distributed real-time simulation of the civil air traffic environment developed to support human factors research in advanced air transportation technology is presented. The distributed environment is based on a custom simulation architecture designed for simplicity and flexibility in human experiments. Standard Internet protocols are used to create the distributed environment, linking all advanced cockpit simulator, all Air Traffic Control simulator, and a pseudo-aircraft control and simulation management station. The pseudo-aircraft control station also functions as a scenario design tool for coordinating human factors experiments. This station incorporates a pseudo-pilot interface designed to reduce workload for human operators piloting multiple aircraft simultaneously in real time. The application of this distributed simulation facility to support a study of the effect of shared information (via air-ground datalink) on pilot/controller shared situation awareness and re-route negotiation is also presented.

Amonlirdviman, Keith↗

A Blueprint for Demonstrating Quantum Supremacy with Superconducting Qubits

Long coherence times and high fidelity control recently achieved in scalable superconducting circuits paved the way for the growing number of experimental studies of many-qubit quantum coherent phenomena in these devices. Albeit full implementation of quantum error correction and fault tolerant quantum computation remains a challenge the near term pre-error correction devices could allow new fundamental experiments despite inevitable accumulation of errors. One such open question foundational for quantum computing is achieving the so called quantum supremacy, an experimental demonstration of a computational task that takes polynomial time on the quantum computer whereas the best classical algorithm would require exponential time and/or resources. It is possible to formulate such a task for a quantum computer consisting of less than a 100 qubits. The computational task we consider is to provide approximate samples from a non-trivial quantum distribution. This is a generalization for the case of superconducting circuits of ideas behind boson sampling protocol for quantum optics introduced by Arkhipov and Aaronson. In this presentation we discuss a proof-of-principle demonstration of such a sampling task on a 9-qubit chain of superconducting gmon qubits developed by Google. We discuss theoretical analysis of the driven evolution of the device resulting in output approximating samples from a uniform distribution in the Hilbert space, a quantum chaotic state. We analyze quantum chaotic characteristics of the output of the circuit and the time required to generate a sufficiently complex quantum distribution. We demonstrate that the classical simulation of the sampling output requires exponential resources by connecting the task of calculating the output amplitudes to the sign problem of the Quantum Monte Carlo method. We also discuss the detailed theoretical modeling required to achieve high fidelity control and calibration of the multi-qubit unitary evolution in the device. We use a novel cross-entropy statistical metric as a figure of merit to verify the output and calibrate the device controls. Finally, we demonstrate the statistics of the wave function amplitudes generated on the 9-gmon chain and verify the quantum chaotic nature of the generated quantum distribution. This verifies the implementation of the quantum supremacy protocol.

Kechedzhi, Kostyantyn↗

The Clinical Development of Molecularly Targeted Agents in Combination With Radiation Therapy: A Pharmaceutical Perspective

Summary: This paper explores historical and current roles of pharmaceutical industry sponsorship of clinical trials testing radiation therapy combinations with molecularly targeted agents and attempts to identify potential solutions to expediting further combination studies. An analysis of clinical trials involving a combination of radiation therapy and novel cancer therapies was performed. Ongoing and completed trials were identified by searching the (clinicaltrials.gov) Web site, in the first instance, with published trials of drugs of interest identified through American Society of Clinical Oncology, European CanCer Organisation/European Society for Medical Oncology, American Society for Radiation Oncology/European Society for Therapeutic Radiology and Oncology, and PubMed databases and then cross-correlated with (clinicaltrials.gov) protocols. We examined combination trials involving radiation therapy with novel agents and determined their distribution by tumor type, predominant molecular mechanisms examined in combination to date, timing of initiation of trials relative to a novel agent's primary development, and source of sponsorship of such trials. A total of 564 studies of targeted agents in combination with radiation therapy were identified with or without concomitant chemotherapy. Most studies were in phase I/II development, with only 36 trials in phase III. The tumor site most frequently studied was head and neck (26%), followed by non-small cell lung cancer. Pharmaceutical companies were the sponsors of 33% of studies overall and provided support for only 16% of phase III studies. In terms of pharmaceutical sponsorship, Genentech was the most active sponsor of radiation therapy combinations (22%), followed by AstraZeneca (14%). Most radiation therapy combination trials do not appear to be initiated until after drug approval. In phase III studies, the most common (58%) primary endpoint was overall survival. Collectively, this analysis suggests that such trials are not given priority by pharmaceutical companies. The potential reasons for this and some challenges and possible solutions are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing the NASA Technical Report Server

The NASA Technical Report Server (NTRS), a World Wide Web report distribution NASA technical publications service, is modified for performance enhancement, greater protocol support, and human interface optimization. Results include: Parallel database queries, significantly decreasing user access times by an average factor of 2.3; access from clients behind firewalls and/ or proxies which truncate excessively long Uniform Resource Locators (URLs); access to non-Wide Area Information Server (WAIS) databases and compatibility with the 239-50.3 protocol; and a streamlined user interface.

Nelson, Michael L.↗

Toward a clinical application of ex situ boron neutron capture therapy for lung tumors at the RA-3 reactor in Argentina

Purpose: Many types of lung tumors have a very poor prognosis due to their spread in the whole organ volume. The fact that boron neutron capture therapy (BNCT) would allow for selective targeting of all the nodules regardless of their position, prompted a preclinical feasibility study of ex situ BNCT at the thermal neutron facility of RA-3 reactor in the province of Buenos Aires, Argentina. (L)-4p-dihydroxy-borylphenylalanine fructose complex (BPA-F) biodistribution studies in an adult sheep model and computational dosimetry for a human explanted lung were performed to evaluate the feasibility and the therapeutic potential of ex situ BNCT. Methods: Two kinds of boron biodistribution studies were carried out in the healthy sheep: a set of pharmacokinetic studies without lung excision, and a set that consisted of evaluation of boron concentration in the explanted and perfused lung. In order to assess the feasibility of the clinical application of ex situ BNCT at RA-3, a case of multiple lung metastases was analyzed. A detailed computational representation of the geometry of the lung was built based on a real collapsed human lung. Dosimetric calculations and dose limiting considerations were based on the experimental results from the adult sheep, and on the most suitable information published in the literature. In addition, a workable treatment plan was considered to assess the clinical application in a realistic scenario. Results: Concentration-time profiles for the normal sheep showed that the boron kinetics in blood, lung, and skin would adequately represent the boron behavior and absolute uptake expected in human tissues. Results strongly suggest that the distribution of the boron compound is spatially homogeneous in the lung. A constant lung-to-blood ratio of 1.3 ± 0.1 was observed from 80 min after the end of BPA-F infusion. The fact that this ratio remains constant during time would allow the blood boron concentration to be used as a surrogate and indirect quantification of the estimated value in the explanted healthy lung. The proposed preclinical animal model allowed for the study of the explanted lung. As expected, the boron concentration values fell as a result of the application of the preservation protocol required to preserve the lung function. The distribution of the boron concentration retention factor was obtained for healthy lung, with a mean value of 0.46 ± 0.14 consistent with that reported for metastatic colon carcinoma model in rat perfused lung. Considering the human lung model and suitable tumor control probability for lung cancer, a promising average fraction of controlled lesions higher than 85% was obtained even for a low tumor-to-normal boron concentration ratio of 2. Conclusions: This work reports for the first time data supporting the validity of the ovine model as an adequate human surrogate in terms of boron kinetics and uptake in clinically relevant tissues. Collectively, the results and analysis presented would strongly suggest that ex situ whole lung BNCT irradiation is a feasible and highly promising technique that could greatly contribute to the treatment of metastatic lung disease in those patients without extrapulmonary spread, increasing not only the expected overall survival but also the resulting quality of life.

60 APPLIED LIFE SCIENCES↗

Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Atomic-ensemble-based quantum repeater against general polarization and phase noise

We present a quantum repeater architecture based on atomic ensembles, which is free of polarization and phase noise. With only simple optical elements, we can obtain the uncorrupted entanglement in the noisy channel. Even if the channel suffers from the general polarization and phase noise, the fidelity of transmitted qubits in our protocol can be stable and have no dependence on the noise parameter, which is a significant advantage compared with previous protocols. Moveover, we can even improve the fidelity by using time delayers. The proposed quantum repeater is feasible and useful in the long-distance quantum entanglement distribution and may be promising in other quantum-information applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗