Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Sci—Fri PM: Dosimetry — 03: Delta4 diode absolute dose response for large and small target volume IMRT QA

The goal of this project was to quantify the over-response/under-response of the Delta4 diodes for Helical Tomotherapy plans on extreme target volume sizes. A custom Delta4 phantom quarter with a hole to insert an ionisation chamber (IC) close to the center of the phantom have been used to acquire simultaneous IC and diodes absolute dose measurements. Eight plans for different target volumes were created from 20cm to 1cm diameter. Diodes dose measurements in the target were compared with IC measurement, to quantify absolute dose accuracy. IC measurements show a good agreement with planned dose (±2%). Diode measurements demonstrate a good agreement with IC for regular target size of 5 and 10cm (0 to 1%). For larger targets, an over-response is observed for FW 25mm and 10mm (2 to 3%). for small target of 1cm diameter, a major under-response is observed for FW 25mm and 10mm (−8 and −36%). The over-response could to be due to the extra amount of scattered radiation and the opposite for under-response. Although this scatter hypothesis still has to be proven, early testing demonstrates an over-response of 40%/20% of the central diodes compare to IC when an open helical rotational beam is delivered 75mm/25mm away from the center of the phantom. These results are in agreement with the real patient Delta4 DQA results at our center.

60 APPLIED LIFE SCIENCES↗

Dose Response for Radiation Cataractogenesis: A Meta-Regression of Hematopoietic Stem Cell Transplantation Regimens

Purpose/Objective(s): To perform a meta-regression on published data and to model the 5-year probability of cataract development after hematopoietic stem cell transplantation (HSCT) with and without total body irradiation (TBI). Methods and Materials: Eligible studies reporting cataract incidence after HSCT with TBI were identified by a PubMed search. Seventeen publications provided complete information on radiation dose schedule, fractionation, dose rate, and actuarial cataract incidence. Chemotherapy-only regimens were included as zero radiation dose regimens. Multivariate meta-regression with a weighted generalized linear model was used to model the 5-year cataract incidence and contributory factors. Results: Data from 1386 patients in 21 series were included for analysis. TBI was administered to a total dose of 0 to 15.75 Gy with single or fractionated schedules with a dose rate of 0.04 to 0.16 Gy/min. Factors significantly associated with 5-year cataract incidence were dose, dose times dose per fraction (D•dpf), pediatric versus adult status, and the absence of an ophthalmologist as an author. Dose rate, graft versus host disease, steroid use, hyperfractionation, and number of fractions were not significant. Five-fold internal cross-validation showed a model validity of 83% ± 8%. Regression diagnostics showed no evidence of lack-of-fit and no patterns in the studentized residuals. The α/β ratio from the linear quadratic model, estimated as the ratio of the coefficients for dose and D•dpf, was 0.76 Gy (95% confidence interval [CI], 0.05-1.55). The odds ratio for pediatric patients was 2.8 (95% CI, 1.7-4.6) relative to adults. Conclusions: Dose, D•dpf, pediatric status, and regimented follow-up care by an ophthalmologist were predictive of 5-year cataract incidence after HSCT. The low α/β ratio indicates the importance of fractionation in reducing cataracts. Dose rate effects have been observed in single institution studies but not in the combined data analyzed here. Although data were limited to articles with 5-year actuarial estimates, the development of radiation-induced cataracts extends beyond this time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iron Oxide Nanoparticle Agglomeration Influences Dose-Rates and Modulates Oxidative Stress Mediated Dose-Response Profiles In Vitro

Spontaneous agglomeration of engineered nanoparticles (ENPs) is a common problem in cell culture media which can confound interpretation of in vitro nanotoxicity studies. The authors created stable agglomerates of iron oxide nanoparticles (IONPs) in conventional culture medium, which varied in hydrodynamic size (276 nm-1.5 μm) but were composed of identical primary particles with similar surface potentials and protein coatings. Studies using C10 lung epithelial cells show that the dose rate effects of agglomeration can be substantial, varying by over an order of magnitude difference in cellular dose in some cases. Quantification by magnetic particle detection showed that small agglomerates of carboxylated IONPs induced greater cytotoxicity and redox-regulated gene expression when compared with large agglomerates on an equivalent total cellular IONP mass dose basis, whereas agglomerates of amine-modified IONPs failed to induce cytotoxicity or redox-regulated gene expression despite delivery of similar cellular doses. Dosimetry modelling and experimental measurements reveal that on a delivered surface area basis, large and small agglomerates of carboxylated IONPs have similar inherent potency for the generation of ROS, induction of stress-related genes and eventual cytotoxicity. The results suggest that reactive moieties on the agglomerate surface are more efficient in catalysing cellular ROS production than molecules buried within the agglomerate core. Because of the dynamic, size and density-dependent nature of ENP delivery to cells in vitro, the biological consequences of agglomeration are not discernible from static measures of exposure concentration (μg/ml) alone, highlighting the central importance of integrated physical characterisation and quantitative dosimetry for in vitro studies. The combined experimental and computational approach provides a quantitative framework for evaluating relationships between the biocompatibility of nanoparticles and their physical and chemical characteristics.

agglomeration↗

Dose–response analysis of phthalate effects on gene expression in rat whole embryo culture

The rat postimplantation whole embryo culture (WEC) model serves as a potential screening tool for developmental toxicity. In this model, cultured rat embryos are exposed during early embryogenesis and evaluated for morphological effects. The integration of molecular-based markers may lead to improved objectivity, sensitivity and predictability of WEC in assessing developmental toxic properties of compounds. In this study, we investigated the concentration-dependent effects of two phthalates differing in potency, mono(2-ethylhexyl) phthalate (MEHP) and monomethyl phthalate (MMP, less toxic), on the transcriptome in WEC to examine gene expression in relation with dysmorphogenesis. MEHP was more potent than MMP in inducing gene expression changes as well as changes on morphology. MEHP induced significant enrichment of cholesterol/lipid/steroid (CLS) metabolism and apoptosis pathways which was associated with developmental toxicity. Regulation of genes within CLS metabolism pathways represented the most sensitive markers of MEHP exposure, more sensitive than classical morphological endpoints. As shown in direct comparisons with toxicogenomic in vivo studies, alterations in the regulation of CLS metabolism pathways has been previously identified to be associated with developmental toxicity due to phthalate exposure in utero. Our results support the application of WEC as a model to examine relative phthalate potency through gene expression and morphological responses. Additionally, our results further define the applicability domain of the WEC model for developmental toxicological investigations. -- Highlights: ► We examine the effect of two phthalates on gene expression and morphology in WEC. ► MEHP is more potent than MMP in inducing gene expression changes and dysmorphogenesis. ► MEHP significantly disrupts cholesterol metabolism pathways in a dose-dependent manner. ► Specific phthalate-related mechanisms in WEC are relevant to mechanisms in vivo.

60 APPLIED LIFE SCIENCES↗

SU-E-T-399: Determination of the Radiobiological Parameters That Describe the Dose-Response Relations of Xerostomia and Disgeusia From Head and Neck Radiotherapy

Purpose: To estimate the radiobiological parameters that describe the doseresponse relations of xerostomia and disgeusia from head and neck cancer radiotherapy. To identify the organs that are best correlated with the manifestation of those clinical endpoints. Finally, to evaluate the goodnessof- fit by comparing the model predictions against the actual clinical results. Methods: In this study, 349 head and neck cancer patients were included. For each patient the dose volume histograms (DVH) of parotids (separate and combined), mandible, submandibular glands (separate and combined) and salivary glands were calculated. The follow-up of those patients was recorded at different times after the completion of the treatment (7 weeks, 3, 7, 12, 18 and 24 months). Acute and late xerostomia and acute disgeusia were the clinical endpoints examined. A maximum likelihood fitting was performed to calculate the best estimates of the parameters used by the relative seriality model. The statistical methods of the error distribution, the receiver operating characteristic (ROC) curve, the Pearson's test and the Akaike's information criterion were utilized to assess the goodness-of-fit and the agreement between the pattern of the radiobiological predictions with that of the clinical records. Results: The estimated values of the radiobiological parameters of salivary glands are D50 = 25.2 Gy, γ = 0.52, s = 0.001. The statistical analysis confirmed the clinical validity of those parameters (area under the ROC curve = 0.65 and AIC = 38.3). Conclusion: The analysis proved that the treatment outcome pattern of the patient material can be reproduced by the relative seriality model and the estimated radiobiological parameters. Salivary glands were found to have strong volume dependence (low relative seriality). Diminishing the biologically effective uniform dose to salivary glands below 30 Gy may significantly reduce the risk of complications to the patients irradiated for prostate cancer.

60 APPLIED LIFE SCIENCES↗

Dose Response, Dosimetric, and Metabolic Evaluations of Replacement PFAS Perfluoro-(2,5,8-trimethyl-3,6,9-trioxadodecanoic) Acid (HFPO-TeA)

Few studies are available on the environmental and toxicological effects of perfluoroalkyl ether carboxylic acids (PFECAs), such as GenX, which are replacing legacy PFAS in manufacturing processes. To collect initial data on the toxicity and toxicokinetics of a longer-chain PFECA, male and female Sprague Dawley rats were exposed to perfluoro-(2,5,8-trimethyl-3,6,9-trioxadodecanoic) acid (HFPO-TeA) by oral gavage for five days over multiple dose levels (0.3–335.2 mg/kg/day). Clinically, we observed mortality at doses >17 mg/kg/day and body weight changes at doses ≤ 17 mg/kg/day. For the 17 mg/kg/day dose level, T3 and T4 thyroid hormone concentrations were significantly decreased (p < 0.05) from controls and HFPO-TeA plasma concentrations were significantly different between sexes. Non-targeted analysis of plasma and in vitro hepatocyte assay extractions revealed the presence of another GenX oligomer, perfluoro-(2,5-dimethyl-3,6-dioxanonanoic) acid (HFPO-TA). In vitro to in vivo extrapolation (IVIVE) parameterized with in vitro toxicokinetic data predicted steady-state blood concentrations that were within seven-fold of those observed in the in vivo study, demonstrating reasonable predictivity. The evidence of thyroid hormone dysregulation, sex-based differences in clinical results and dosimetry, and IVIVE predictions presented here suggest that the replacement PFECA HFPO-TeA induces a complex and toxic exposure response in rodents.

54 ENVIRONMENTAL SCIENCES↗

Dose–response assessment of nephrotoxicity from a twenty-eight-day combined-exposure to melamine and cyanuric acid in F344 rats

The adulteration of pet food with melamine and derivatives, including cyanuric acid, has been implicated in the kidney failure and death of cats and dogs in the USA and other countries. In a previous 7-day dietary study in F344 rats, we established a no-observed-adverse-effect level (NOAEL) for a co-exposure to melamine and cyanuric acid of 8.6 mg/kg bw/day of each compound, and a benchmark dose lower confidence limit (BMDL) of 8.4–10.9 mg/kg bw/day of each compound. To ascertain the role played by the duration of exposure, we treated F344 rats for 28 days. Groups of male and female rats were fed diet containing 0 (control), 30, 60, 120, 180, 240, or 360 ppm of both melamine and cyanuric acid. The lowest dose that produced histopathological alterations in the kidney was 120 ppm, versus 229 ppm in the 7-day study. Wet-mount analysis of kidney sections demonstrated the formation of melamine cyanurate spherulites in one male and two female rats at the 60 ppm dose and in one female rat at the 30 ppm dose, establishing a NOAEL of 2.1 mg/kg bw/day for males and < 2.6 mg/kg bw/day for females, and BMDL values as low as 1.6 mg/kg bw/day for both sexes. These data demonstrate that the length of exposure is an important component in the threshold of toxicity from a co-exposure to these compounds and suggest that the current risk assessments based on exposures to melamine alone may not reflect sufficiently the risk of a co-exposure to melamine and cyanuric acid. -- Highlights: ► A 28-day dietary co-exposure to melamine and cyanuric acid was conducted in F344 rats. ► The NOAELs were 2.1 mg/kg bw/day for males and < 2.6 mg/kg bw/day for females. ► BMDL values as low as 1.6 mg/kg bw/day for both sexes were determined. ► The length of exposure plays an important role in the threshold of toxicity. ► Current assessments may underestimate the risk of melamine and cyanuric acid.

60 APPLIED LIFE SCIENCES↗

Prostate Stereotactic Body Radiation Therapy: An Overview of Toxicity and Dose Response

Ultrahypofractionationed radiation therapy for prostate cancer is increasingly studied and adopted. The American Association of Physicists in Medicine Working Group on Biological Effects of Hypofractionated Radiotherapy therefore aimed to review studies examining toxicity and quality of life after stereotactic body radiation therapy (SBRT) for prostate cancer and model its effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detector dose response in megavoltage small photon beams. I. Theoretical concepts

Purpose: To explain the reasons for significant quality correction factors in megavoltage small photon fields and clarify the underlying concepts relevant to dosimetry under such conditions. Methods: The validity of cavity theory and the requirement of charged particle equilibrium (CPE) are addressed from a theoretical point of view in the context of nonstandard beams. Perturbation effects are described into four main subeffects, explaining their nature and pointing out their relative importance in small photon fields. Results: It is demonstrated that the failure to meet classical cavity theory requirements, such as CPE, is not the reason for significant quality correction factors. On the contrary, it is shown that the lack of CPE alone cannot explain these corrections and that what matters most, apart from volume averaging effects, is the relationship between the lack of CPE in the small field itself and the density of the detector cavity. The density perturbation effect is explained based on Fano’s theorem, describing the compensating effect of two main contributions to cavity absorbed dose. Using the same approach, perturbation effects arising from the difference in atomic properties of the cavity medium and the presence of extracameral components are explained. Volume averaging effects are also discussed in detail. Conclusions: Quality correction factors of small megavoltage photon fields are mainly due to differences in electron density between water and the detector medium and to volume averaging over the detector cavity. Other effects, such as the presence of extracameral components and differences in atomic properties of the detection medium with respect to water, can also play an accentuated role in small photon fields compared to standard beams.

07 ISOTOPE AND RADIATION SOURCES↗

Computational Modeling of Micrometastatic Breast Cancer Radiation Dose Response

Purpose: Prophylactic cranial irradiation (PCI) involves giving radiation to the entire brain with the goals of reducing the incidence of brain metastasis and improving overall survival. Experimentally, we have demonstrated that PCI prevents brain metastases in a breast cancer mouse model. We developed a computational model to expand on and aid in the interpretation of our experimental results. Methods and Materials: MATLAB was used to develop a computational model of brain metastasis and PCI in mice. Model input parameters were optimized such that the model output would match the experimental number of metastases per mouse from the unirradiated group. An independent in vivo–limiting dilution experiment was performed to validate the model. The effect of whole brain irradiation at different measurement points after tumor cells were injected was evaluated in terms of the incidence, number of metastases, and tumor burden and was then compared with the corresponding experimental data. Results: In the optimized model, the correlation between the number of metastases per mouse and the experimental fits was >95. Our attempt to validate the model with a limiting dilution assay produced 99.9% correlation with respect to the incidence of metastases. The model accurately predicted the effect of whole-brain irradiation given 3 weeks after cell injection but substantially underestimated its effect when delivered 5 days after cell injection. The model further demonstrated that delaying whole-brain irradiation until the development of gross disease introduces a dose threshold that must be reached before a reduction in incidence can be realized. Conclusions: Our computational model of mouse brain metastasis and PCI correlated strongly with our experiments with unirradiated mice. The results further suggest that early treatment of subclinical disease is more effective than irradiating established disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects

Purpose: To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. Methods: In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fields. Fano’s theorem is adapted in the form of a cavity theory and applied in the context of nonstandard beams to express four main effects in the form of perturbation factors. The pencil-beam decomposition method is detailed and adapted to the calculation of perturbation factors and quality correction factors. The approach defines a perturbation function which, for a given field size or beam modulation, entirely determines these dosimetric factors. Monte Carlo calculations are performed in different cavity sizes for different detection materials, electron densities, and extracameral components. Results: Perturbation effects are detailed with calculated perturbation functions, showing the relative magnitude of the effects as well as the geometrical extent to which collimating or modulating the beam impacts the dosimetric factors. The existence of a perturbation zone around the detector cavity is demonstrated and the approach is discussed and linked to previous approaches in the literature to determine critical field sizes. Conclusions: Monte Carlo simulations are valuable to describe pencil beam perturbation effects and detail the nature of dosimetric factors in megavoltage small photon fields. In practice, it is shown that dosimetric factors could be avoided if the field size remains larger than the detector perturbation zone. However, given a detector and beam quality, a full account for the detector geometry is necessary to determine critical field sizes.

07 ISOTOPE AND RADIATION SOURCES↗

Dose-Response for Stereotactic Body Radiotherapy in Early-Stage Non-Small-Cell Lung Cancer

Purpose: To compare the efficacy of three lung stereotactic body radiotherapy (SBRT) regimens in a large institutional cohort. Methods: Between 2004 and 2009, 130 patients underwent definitive lung cancer SBRT to a single lesion at the Mallinckrodt Institute of Radiology. We delivered 18 Gy Multiplication-Sign 3 fractions for peripheral tumors (n = 111) and either 9 Gy Multiplication-Sign 5 fractions (n = 8) or 10 Gy Multiplication-Sign 5 fractions (n = 11) for tumors that were central or near critical structures. Univariate and multivariate analysis of prognostic factors was performed using the Cox proportional hazard model. Results: Median follow-up was 11, 16, and 13 months for the 9 Gy Multiplication-Sign 5, 10 Gy Multiplication-Sign 5, and 18 Gy Multiplication-Sign 3 groups, respectively. Local control statistics for Years 1 and 2 were, respectively, 75% and 50% for 9 Gy Multiplication-Sign 5, 100% and 100% for 10 Gy Multiplication-Sign 5, and 99% and 91% for 18 Gy Multiplication-Sign 3. Median overall survival was 14 months, not reached, and 34 months for the 9 Gy Multiplication-Sign 5, 10 Gy Multiplication-Sign 5, and 18 Gy Multiplication-Sign 3 treatments, respectively. No difference in local control or overall survival was found between the 10 Gy Multiplication-Sign 5 and 18 Gy Multiplication-Sign 3 groups on log-rank test, but both groups had improved local control and overall survival compared with 9 Gy Multiplication-Sign 5. Treatment with 9 Gy Multiplication-Sign 5 was the only independent prognostic factor for reduced local control on multivariate analysis, and increasing age, increasing tumor volume, and poor performance status predicted independently for reduced overall survival. Conclusion: Treatment regimens of 10 Gy Multiplication-Sign 5 and 18 Gy Multiplication-Sign 3 seem to be efficacious for lung cancer SBRT and provide superior local control and overall survival compared with 9 Gy Multiplication-Sign 5.

62 RADIOLOGY AND NUCLEAR MEDICINE↗