Search NASA⌕ Search

SEARCH · Search NASA

Results for “EBIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Evaluation of magnetic field error in ExtendedEBIS

The upgrade of the EBIS, called ExtendedEBIS, is now in progress in Brookhaven National Laboratory. Two 5T-superconducting solenoids have been placed in series with 200 mm distance from each other for higher trap capacity and production of polarized 3He ions. Since the two superconducting solenoids are used, the field error is expected to be larger. In this research, the field error is estimated based on simulation. It was found that the magnetic field line can be 17 mm off from the center axis at the entrance of the collector, and this offset can be adjusted by three types of correction coils. Additionally, mismatch of the spin direction of polarized 3He due to the misalignment was estimated to be small.

Ikeda, Shunsuke (ORCID:0000000339800577)↗

Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

Interacting spin-2 fields in the Stückelberg picture

We revisit and extend the 'Effective field theory for massive gravitons' constructed by Arkani-Hamed, Georgi and Schwartz in the light of recent progress in constructing ghost-free theories with multiple interacting spin-2 fields. We show that there exist several dual ways of restoring gauge invariance in such multi-gravity theories, find a generalised Fierz-Pauli tuning condition relevant in this context and highlight subtleties in demixing tensor and scalar modes. The generic multi-gravity feature of scalar mixing and its consequences for higher order interactions are discussed. In particular we show how the decoupling limit is qualitatively changed in theories of interacting spin-2 fields. We relate this to dRGT (de Rham, Gabadadze, Tolley) massive gravity, Hassan-Rosen bigravity and the multi-gravity constructions by Hinterbichler and Rosen. As an additional application we show that EBI (Eddington-Born-Infeld) bigravity and higher order generalisations thereof possess ghost-like instabilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In situ effective pumping speed measurements as a tool for non-evaporable getter activation and saturation monitoring

We have developed method of in situ effective pumping speed measurements based on injecting finite gas pulse into a vacuum volume and subsequent recording of pressure response using a Residual Gas Analyzer (RGA). The pressure burst caused by injected gas pulse falls exponentially in time and the exponential coefficient of such pressure decay is proportional to total effective pumping speed of all vacuum pumps acting on vacuum chamber volume. The effective pumping speed can be extracted from the dependence of injected gas species pressure vs time recorded by an RGA. Non-Evaporable Getters (NEGs) are widely used in multiple ultra and extremely high vacuum devices and applications during the last several decades. Areas of NEG applications were recently expanded into vacuum devices with relatively high-pressure levels (up to 10 -7 Torr) by the invention of high capacity ZAO NEG which can be operated at elevated temperatures. The intrinsic property of all NEG-based vacuum pumps is the reduction of their pumping speed, called “NEG saturation”, after an extended period of operation. Typical time interval for such process can span from about a month and up to a few years depending on NEG type, vacuum level of NEG pump operation, and residual gas content. After that, the NEG pump will require a re-activation cycle to restore its pumping speed close to the initial value. For many applications it is difficult to realize what is the current pumping speed of NEG pump is and when the pump should be re-activated. A method for in situ effective pumping speed measurements developed in this study can be used as a tool for NEG-based pump activation and saturation monitoring. Application of such an approach to monitor pumping status of NEG pumps was utilized and will be continually used at Extended EBIS which was recently developed and commissioned for Relativistic Heavy Ion Collider (RHIC) and future Electron Ion Collider (EIC). The results obtained during commissioning are presented and discussed.

43 PARTICLE ACCELERATORS↗

Disease Ontology 2015 update: An expanded and updated database of human diseases for linking biomedical knowledge through disease data

The current version of the Human Disease Ontology (DO) (http://www.disease-ontology.org) database expands the utility of the ontology for the examination and comparison of genetic variation, phenotype, protein, drug and epitope data through the lens of human disease. DO is a biomedical resource of standardized common and rare disease concepts with stable identifiers organized by disease etiology. The content of DO has had 192 revisions since 2012, including the addition of 760 terms. Thirty-two percent of all terms now include definitions. DO has expanded the number and diversity of research communities and community members by 50+ during the past two years. These community members actively submit term requests, coordinate biomedical resource disease representation and provide expert curation guidance. Since the DO 2012 NAR paper, there have been hundreds of term requests and a steady increase in the number of DO listserv members, twitter followers and DO website usage. DO is moving to a multi-editor model utilizing Protégé to curate DO in web ontology language. In conclusion, this will enable closer collaboration with the Human Phenotype Ontology, EBI's Ontology Working Group, Mouse Genome Informatics and the Monarch Initiative among others, and enhance DO's current asserted view and multiple inferred views through reasoning.

59 BASIC BIOLOGICAL SCIENCES↗

Community recommendations on cryoEM data archiving and validation

In January 2020, a workshop was held at EMBL-EBI (Hinxton, UK) to discuss data requirements for the deposition and validation of cryoEM structures, with a focus on single-particle analysis. The meeting was attended by 47 experts in data processing, model building and refinement, validation, and archiving of such structures. This report describes the workshop's motivation and history, the topics discussed, and the resulting consensus recommendations. Some challenges for future methods-development efforts in this area are also highlighted, as is the implementation to date of some of the recommendations.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Thoughts on polarimetry for {sup 3}He beams at RHIC

The Relativistic Heavy Ions Collider (RHIC) has accelerated polarized proton beams for physics since 2001. As part of the future eRHIC program and in order to enhance access to the down quark, a program to accelerate polarized {sup 3}He in the AGS and RHIC is envisioned. To that end, a polarized {sup 3}He source is being built at MIT. This will be installed on the BNL EBIS source in preparation for injection into the booster and AGS. As an early exercise, in June 2012, unpolarized {sup 3}He beams have been accelerated in the AGS. This paper will peruse some potential ideas for {sup 3}He polarimetry and calibration that could be utilized at the AGS as well as RHIC. The current proton polarimetry program serves as a guide.

43 PARTICLE ACCELERATORS↗

Considerations on the design of a rare isotope beam facility based on superconducting heavy ion linacs

To establish an accelerator facility based on superconducting linear accelerator (linac) for nuclear and applied sciences in Korea, the rare isotope science project started in December 2011 under the auspices of the Institute for Basic Science (IBS). The layout of the facility has been mostly frozen since 2013 and civil construction began in 2016. On the other hand, an alternative linac design option was recently investigated in collaboration with the linac development group of Argonne National Lab in search of a further optimized configuration. A new linac lattice was developed and evaluated against realistic machine errors using TRACK. The beam optics simulations and error analysis then proved the soundness of this alternative design. In addition, beam optics of the injector was studied for simultaneous acceleration of both stable and rare isotope beams with the use of an electron beam ion source (EBIS). Additionally considered are alternative options of high-power cyclotrons as ISOL driver in order to enhance the capability of rare isotope beam production and fully exploit the superconducting linac facility built at high cost.

07 ISOTOPE AND RADIATION SOURCES↗

CLO: The cell line ontology

Cell lines have been widely used in biomedical research. The community-based Cell Line Ontology (CLO) is a member of the OBO Foundry library that covers the domain of cell lines. Since its publication two years ago, significant updates have been made, including new groups joining the CLO consortium, new cell line cells, upper level alignment with the Cell Ontology (CL) and the Ontology for Biomedical Investigation, and logical extensions. Collaboration among the CLO, CL, and OBI has established consensus definitions of cell line-specific terms such as ‘cell line’, ‘cell line cell’, ‘cell line culturing’, and ‘mortal’ vs. ‘immortal cell line cell’. A cell line is a genetically stable cultured cell population that contains individual cell line cells. The hierarchical structure of the CLO is built based on the hierarchy of the in vivo cell types defined in CL and tissue types (from which cell line cells are derived) defined in the UBERON cross-species anatomy ontology. The new hierarchical structure makes it easier to browse, query, and perform automated classification. We have recently added classes representing more than 2,000 cell line cells from the RIKEN BRC Cell Bank to CLO. Overall, the CLO now contains ~38,000 classes of specific cell line cells derived from over 200 in vivo cell types from various organisms. The CLO has been applied to different biomedical research studies. Example case studies include annotation and analysis of EBI ArrayExpress data, bioassays, and host-vaccine/pathogen interaction. CLO’s utility goes beyond a catalogue of cell line types. The alignment of the CLO with related ontologies combined with the use of ontological reasoners will support sophisticated inferencing to advance translational informatics development.

59 BASIC BIOLOGICAL SCIENCES↗

R&D ERL: Beam Dump

As its name suggests, the beam dump is where electron bunches end up while depositing energy unrecovered by the ERL. The process of removing unrecovered energy must not have any adverse effects on the ERL system like outgassing or backstreaming electrons. Electron beam dumps are widely used in various applications ranging from radiation generating devices like klystrons and traveling wave tubes to EBIS sources and electron beam coolers, as well as to large machines that include LINACs and electron colliders. Energy of discarded electrons range from a few electron volts to 10's of GeV. This beam dump has a couple of unique issues that determine the design concept: cascade showers and seals that can withstand high radiation dosage.

43 PARTICLE ACCELERATORS↗

Simulations of Merging and Squeezing Bunches in Booster and AGS

During the 2012 RHIC run, uranium, gold, and copper ions from EBIS were accelerated in Booster and AGS and delivered to RHIC for the physics program. In order to achieve the desired number of ions per bunch in RHIC, it was necessary to merge bunches in both Booster and AGS. After the bunches are merged in AGS, they need to be squeezed into harmonic 12 buckets for subsequent acceleration. In this note we carry out simulations of bunch merging and squeezing in Booster and AGS. These are meant to serve as benchmarks for what can be achieved in practice. In Booster the total longitudinal emittance of the 4 bunches to be merged is taken to be 0.15 eV s per nucleon. In AGS the total for each group of 4 bunches to be merged is taken to be 0.60 eV s per nucleon. The simulations show that the RF voltages currently available in Booster and AGS are sufficient for merging and holding the merged bunches in RF buckets. The voltages available in AGS are not sufficient for completely squeezing the merged bunches into harmonic 12 buckets. The merging of bunches is treated in sections 9 through 12. The required squeezing into harmonic 12 buckets is treated in sections 13 and 14. Debunching and rebunching beam as an alternative to merging bunches in Booster is treated in section 15. For completeness, sections 1 through 8 give a derivation of the turn-by-turn equations of longitudinal motion at constant magnetic field. The derivation is based on the work of MacLachlan. The reader may wish to skip over these sections and start with section 9.

43 PARTICLE ACCELERATORS↗

Optics modification of the electron collector for the Relativistic Heavy Ion Collider Electron Beam Ion Source

The Electron Beam Ion Source (EBIS) for the Relativistic Heavy Ion Collider (RHIC) at the Brookhaven National Laboratory (BNL) operates with electron beam current up to 10 A and frequency up to 4-5 Hz. The observation of the vacuum conditions and the temperature of the electron repeller electrode inside the electron collector (EC) points to heavy heating of this electrode by the backscattered electrons generated by the primary electron beam on the inner surfaces of the EC. The ion optics adjacent to the EC operates at potentials of up to 50 kV and higher and the flashes of the desorbed gas may cause discharges and have detrimental effect on the vacuum conditions in the ion trap, and possible instability of the extracted ion beam. The proposed modification of the EC optics has a goal of eliminating the heating of the internal EC electrodes with preservation of the existing structure of the ion optics. The results of computer simulations of the electron beam dissipation and ion extraction are presented.

43 PARTICLE ACCELERATORS↗

Parameters for the Injection, Acceleration, and Extraction of Gold and Copper Ions in Booster, AGS, and RHIC

During the 2012 RHIC run, uranium, gold, and copper ions from EBIS were accelerated in Booster and AGS and delivered to RHIC for the physics program. In this note the nominal parameters for gold and copper are given. The parameters for uranium are given in a separate note. In order to achieve the desired number of ions per bunch in RHIC, it was necessary to merge bunches in both Booster and AGS.

43 PARTICLE ACCELERATORS↗

Parameters for the Injection, Acceleration, and Extraction of Uranium Ions in Booster, AGS, and RHIC

During the 2012 RHIC run, uranium, gold, and copper ions from EBIS were accelerated in Booster and AGS and delivered to RHIC for the physics program. In this note the nominal parameters for uranium are given. The parameters for gold and copper are given in a separate note. In order to achieve the desired number of ions per bunch in RHIC, it was necessary to merge bunches in both Booster and AGS.

43 PARTICLE ACCELERATORS↗

Energy Recovery Linac: Beam Dump

As its name suggests, the beam dump is where electron bunches end up while depositing energy unrecovered by the ERL. The process of removing unrecovered energy must not have any adverse effects on the ERL system like outgassing or backstreaming electrons. Electron beam dumps are widely used in various applications ranging from radiation generating devices like klystrons and traveling wave tubes to EBIS sources and electron beam coolers, as well as to large machines that include LINACs and electron colliders. Energy of discarded electrons range from a few electron volts to 10’s of GeV.

43 PARTICLE ACCELERATORS↗

Optics modification of the electron collector for the Relativistic Heavy Ion Collider Electron Beam Ion Source

The Electron Beam Ion Source (EBIS) for the Relativistic Heavy Ion Collider (RHIC) at the Brookhaven National Laboratory (BNL) operates with electron beam current up to 10 A and frequency up to 4-5 Hz. The observation of the vacuum conditions and the temperature of the electron repeller electrode inside the electron collector (EC) points to heavy heating of this electrode by the backscattered electrons generated by the primary electron beam on the inner surfaces of the EC. The ion optics adjacent to the EC operates at potentials of up to 50 kV and higher and the flashes of the desorbed gas may cause discharges and have detrimental effect on the vacuum conditions in the ion trap, and possible instability of the extracted ion beam. The proposed modification of the EC optics has a goal of eliminating the heating of the internal EC electrodes with preservation of the existing structure of the ion optics. The results of computer simulations of the electron beam dissipation and ion extraction are presented.

43 PARTICLE ACCELERATORS↗

Simulations of Merging and Squeezing Bunches in Booster and AGS

During the 2012 RHIC run, uranium, gold, and copper ions from EBIS were accelerated in Booster and AGS and delivered to RHIC for the physics program. In order to achieve the desired number of ions per bunch in RHIC, it was necessary to merge bunches in both Booster and AGS. After the bunches are merged in AGS, they need to be squeezed into harmonic 12 buckets for subsequent acceleration. In this note we carry out simulations of bunch merging and squeezing in Booster and AGS. These are meant to serve as benchmarks for what can be achieved in practice. In Booster the total longitudinal emittance of the 4 bunches to be merged is taken to be 0.15 eV s per nucleon. In AGS the total for each group of 4 bunches to be merged is taken to be 0.60 eV s per nucleon. The simulations show that the RF voltages currently available in Booster and AGS are sufficient for merging and holding the merged bunches in RF buckets. The voltages available in AGS are not sufficient for completely squeezing the merged bunches into harmonic 12 buckets. The merging of bunches is treated in sections 9 through 12. The required squeezing into harmonic 12 buckets is treated in sections 13 and 14. Debunching and rebunching beam as an alternative to merging bunches in Booster is treated in section 15. For completeness, sections 1 through 8 give a derivation of the turn-by-turn equations of longitudinal motion at constant magnetic field. The derivation is based on the work of MacLachlan. The reader may wish to skip over these sections and start with section 9.

43 PARTICLE ACCELERATORS↗

Report on the 2011 Critical Assessment of Function Annotation (CAFA) meeting

The Critical Assessment of Function Annotation meeting was held July 14-15, 2011 at the Austria Conference Center in Vienna, Austria. There were 73 registered delegates at the meeting. We thank the DOE for this award. It helped us organize and support a scientific meeting AFP 2011 as a special interest group (SIG) meeting associated with the ISMB 2011 conference. The conference was held in Vienna, Austria, in July 2011. The AFP SIG was held on July 15-16, 2011 (immediately preceding the conference). The meeting consisted of two components, the first being a series of talks (invited and contributed) and discussion sections dedicated to protein function research, with an emphasis on the theory and practice of computational methods utilized in functional annotation. The second component provided a large-scale assessment of computational methods through participation in the Critical Assessment of Functional Annotation (CAFA). The meeting was exciting and, based on feedback, quite successful. There were 73 registered participants. The schedule was only slightly different from the one proposed, due to two cancellations. Dr. Olga Troyanskaya has canceled and we invited Dr. David Jones instead. Similarly, instead of Dr. Richard Roberts, Dr. Simon Kasif gave a closing keynote. The remaining invited speakers were Janet Thornton (EBI) and Amos Bairoch (University of Geneva).

59 BASIC BIOLOGICAL SCIENCES↗