Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Critical review of electrical conductivity measurements and charge distribution analysis of magnesium oxide

The electrical conductivity sigma of MgO single crystals shows a sharp increase at 500-800 C, in particular of sigma surface, generally attributed to surface contamination. Charge Distribution Analysis (CDA), a new technique providing information on fundamental properties that was previously unavailable, allows for the determination of surface charges, their sign and associated internal electric field. Data on 99.99% purity, arc-fusion grown MgO crystals show that mobile charge carriers start to appear in the bulk of the MgO crystals between 200 and 400 C when sigma (measured by conventional techniques) is in t he 10(exp -14) to 10(exp -16) /omega/cm range. Above 500 C, as sigma increases to 10(exp -6) to 10(exp -7)/omega/cm, more charges appear giving rise to a strong positive surface charge supported by a strong internal field. This indicates that charges are generated in the bulk and diffuse to the surface by an internally controlled process. On the basis of their positive sign they are identified as holes (defect electrons). Because of the low cation content of these very pure MgO crystals, theses holes cannnot be associated with transition metal impurties. Instead, they are associated with the O(2-) sublattice, e.g. consist of O(-) states or positive holes. This conclusion is supported by magnetic susceptibility data showing the appearance of 1000 +/- 500 ppm paramagnetic species between 200-500 C. The magnetic data are consistent with strongly coupled, diamagnetic O(-) pairs below 200-500 C, chemically equivalent to peroxy anions, O2(2-), and probably associated with cation vacancies in the MgO matrix. The formation of O2(2-) in arc-fusion grown MgO crystals is very unexpected because of the highly reducing growth conditions. Their presence implies an internal redox reaction involving dissolved 'water' by which OH(-) pairs convert to O2(2-) plus H2 molecules. This redox conversion is supported by mass spectroscopic measurements of the H2 release from highly OH(-)-doped, finely divided MgO and by wet-chemical analysis of its oxidant concentration.

Freund, Friedemann↗

Extendible-retractable electric field measurement antenna for IMP J

An antenna dispenser mechanism for the IMP J spacecraft was designed, fabricated, and tested. Upon command the mechanism deploys or retracts a conductor for use as a receiving antenna for an electric field measurement experiment. Five identical units were fabricated and tested to the IMP H & J environmental test specification. Of these, four are designated for flight on the IMP J spacecraft and one as a prototype flight spare. The testing program was successfully completed although certain design modifications were required as problems were uncovered by the testing; particularly thermal vacuum operation. The antenna mechanism functions well under the expected environmental and loading conditions. The wear life and load capability of the dry molybdenum disulphide lubricant originally used on the heavily loaded worm and gear pair were disappointing and a substitute material was applied. The lubricant finally applied performed well; although other problems were generated.

Larrick, W.↗

Flow Control and Measurement in Electric Propulsion Systems: Towards an AIAA Reference Standard

Accurate control and measurement of propellant flow to a thruster is one of the most basic and fundamental requirements for operation of electric propulsion systems, whether they be in the laboratory or on flight spacecraft. Hence, it is important for the electric propulsion community to have a common understanding of typical methods for flow control and measurement. This paper addresses the topic of propellant flow primarily for the gaseous propellant systems which have dominated laboratory research and flight application over the last few decades, although other types of systems are also briefly discussed. While most flight systems have employed a type of pressure-fed flow restrictor for flow control, both thermal-based and pressure-based mass flow controllers are routinely used in laboratories. Fundamentals and theory of operation of these types of controllers are presented, along with sources of uncertainty associated with their use. Methods of calibration and recommendations for calibration processes are presented. Finally, details of uncertainty calculations are presented for some common calibration methods and for the linear fits to calibration data that are commonly used.

thrust measurement↗

A thundercloud electric field sounding - Charge distribution and lightning

An instrumented free balloon measured electric fields and field changes as it rose through a thundercloud above Langmuir Laboratory, New Mexico. The variation of the electric field with altitude implied that the cloud contained negative space charge of density -0.6 to -4 nC/cu m between 5.5 and 8.0 km MSL. The environmental temperature at these levels ranged from -5 to -20 C. The measurements imply that the areal extent of this negative charge center was significantly greater than that of the cloud's intense precipitation shafts. At altitudes greater than 8 km, the instrument ascended past net positive charge. In addition, positive space charge adjacent to the earth's surface (concentration 0.6 nC/cu m and in the lowest portion of the cloud (1.0 nC/cu m) is inferred from the measurements. Electric field changes from intracloud lightning were interpreted by using a simple model for the developing streamer of the initial phase. Thunder source reconstructions provided estimates for the orientation of lightning channels. Seven 'streamers' so analyzed propagated on the average, at 50,000 m/s and carried a current of 390 A. The mean charge dissipated during a flash was 30 C.

Weber, M. E.↗

Classification of Tropical Oceanic Precipitation Using High Altitude Aircraft Microwave and Electric Field Measurements

A physically intuitive and computationally simple precipitation mapping algorithm has been developed for use with the airborne Advanced Microwave Precipitation Radiometer (AMPR). The algorithm is based on microwave emission and scattering properties of precipitation. Specifically, emission by liquid water allows increasing brightness temperatures at low frequencies to be interpreted as increasing rain rates. Scattering by large hydrometeors (particularly graupel and hail) causes relative minima in the brightness temperatures, with progressively larger hydrometeors scattering progressively longer wavelengths. The vigor of convection is therefore ascertained according to which wavelengths are being significantly scattered. The combination of emission and scattering information from four microwave channels is used to assign a precipitation category, which is related to the liquid rain rate, the vertical extent of precipitation, and the vigor of convection. The qualitative precipitation categories output by the passive microwave algorithm have been verified using coincident radar (ER-2 Doppler Radar - EDOP) and electric field measurements (Lightning Instrument Package - LIP). These coincident measurements can subsequently be used to quantify rain rates, hydrometeor contents, and vertical profiles that are typical for each precipitation category. This algorithm has been developed using an airborne platform. Comparisons are being made with other airborne, satellite, and ground-based radar and radiometer data. This technique shows promise both as a research tool and potentially as a real-time analysis tool, which could be applied to either traditional or uninhabited aerial vehicles.

Cecil, Daniel J.↗

Classification of Tropical Oceanic Precipitation Using High Altitude Aircraft Microwave and Electric Field Measurements

A physically intuitive and computationally simple precipitation mapping algorithm has been developed for use with the airborne Advanced Microwave Precipitation Radiometer (AMPR). The algorithm is based on microwave emission and scattering properties of precipitation. Specifically, emission by liquid water allows increasing brightness temperatures at low frequencies to be interpreted as increasing rain rates. Scattering by large hydrometeors (particularly graupel and hail) causes relative minima in the brightness temperatures, with progressively larger hydrometeors scattering progressively longer wavelengths. The vigor of convection is therefore ascertained according to which wavelengths are being significantly scattered. The combination of emission and scattering information from four microwave channels is used to assign a precipitation category, which is related to the liquid rain rate, the vertical extent of precipitation, and the vigor of convection. The qualitative precipitation categories output by the passive microwave algorithm have been verified using coincident radar (ER-2 Doppler Radar - EDOP) and electric field measurements (Lightning Instrument Package - LIP). These coincident measurements can subsequently be used to quantify rain rates, hydrometeor contents, and vertical profiles that are typical for each precipitation category. This algorithm has been developed using an airborne platform. Comparisons are being made with other airborne, satellite, and ground-based radar and radiometer data. This technique shows promise both as a research tool and potentially as a real-time analysis tool, which could be applied to either traditional or uninhabited aerial vehicles.

Cecil, Daniel J.↗

The split-cross-bridge resistor for measuring the sheet resistance, linewidth, and line spacing of conducting layers

A new test structure was developed for evaluating the line spacing between conductors on the same layer using an electrical measurement technique. This compact structure can also be used to measure the sheet resistance, linewidth, and line pitch of the conducting layer. Using an integrated-circuit fabrication process, this structure was fabricated in diffused polycrystalline silicon and metal layers and measured optically and electrically. For the techniques used, the optical measurements were typically one-quarter micron greater than the electrical measurements. Most electrically measured line pitch values were within 2 percent of the designed value. A small difference between the measured and designed line pitch is used to validate sheet resistance, linewidth, and line spacing values.

Buehler, M. G.↗

Electric field measuring and display system

An apparatus is described for monitoring the electric fields of cloud formations within a particular area. It utilizes capacitor plates that are alternately shielded from the clouds for generating an alternating signal corresponding to the intensity of the electric field of the clouds. A synchronizing signal is produced for controlling sampling of the alternating signal. Such samplings are fed through a filter and converted by an analogue to digital converter into digital form and subsequently fed to a transmitter for transmission to the control station for recording.

Wojtasinski, R. J.↗

Merits of supplemental ground-based measurements of lightning electric fields in the interpretation of airborne measurements

Calculations are presented which indicate that airborne recordings of the electric fields from lightning will be difficult to interpret without correlated continuous broadband electric field measurements at a ground-based station. Furthermore, through application of the results in Master et al. (1981), field measurements made at altitudes above ground may be calibrated by comparison with ground-based measurements of the same discharge. The requirements of the electric-field recording systems sufficient for identification, characterization, and calibration of airborne field measurements are discussed.

Beasley, W. H.↗

Electric Field and Lightning Observations in the Core of Category 5 Hurricane Emily

Significant electric fields and lightning activity associated with Hurricane Emily were observed from a NASA high-altitude ER-2 aircraft on July 17, 2005 while this storm developed as a compact but intense category 5 hurricane in the Caribbean south of Cuba. The electrical measurements were acquired as part of the NASA sponsored Tropical Cloud Systems and Processes (TCSP) experiment. In addition to the electrical measurements, the aircraft's remote sensing instrument complement also included active radars, passive microwave, visible and infrared radiometers, and a temperature sounder providing details on the dynamical, microphysical, and environmental structure, characteristics and development of this intense storm. Cloud-to-ground lightning location data from Vaisala's long range lightning detection network were also acquired and displayed in real-time along with electric fields measured at the aircraft. These data and associated display also supported aircraft guidance and vectoring during the mission. During the observing period, flash rates in excess of 3 to 5 flashes per minute, as well as large electric field and field change values were observed as the storm appeared to undergo periods of intensification, especially in the northwest quadrant in the core eyewall regions. This is in contrast to most hurricanes that tend to be characterized by weak electrification and little or no lightning activity except in the outer rain bands. It should be noted that this storm also had significant lightning associated with its rain bands.

Blakeslee, Richard↗

Aircraft electric field measurements: Calibration and ambient field retrieval

An aircraft locally distorts the ambient thundercloud electric field. In order to determine the field in the absence of the aircraft, an aircraft calibration is required. In this work a matrix inversion method is introduced for calibrating an aircraft equipped with four or more electric field sensors and a high-voltage corona point that is capable of charging the aircraft. An analytic, closed form solution for the estimate of a (3 x 3) aircraft calibration matrix is derived, and an absolute calibration experiment is used to improve the relative magnitudes of the elements of this matrix. To demonstrate the calibration procedure, we analyze actual calibration date derived from a Lear jet 28/29 that was equipped with five shutter-type field mill sensors (each with sensitivities of better than 1 V/m) located on the top, bottom, port, starboard, and aft positions. As a test of the calibration method, we analyze computer-simulated calibration data (derived from known aircraft and ambient fields) and explicitly determine the errors involved in deriving the variety of calibration matrices. We extend our formalism to arrive at an analytic solution for the ambient field, and again carry all errors explicitly.

Koshak, William J.↗

Apparatus Measures Seebeck Coefficient And Resistivity

Electrical measurements made by four point probes, two of which double as temperature probes. Laboratory apparatus measures both Seebeck coefficients and electrical resistivities of candidate thermoelectric materials at temperatures from ambient to 1,300 K. Apparatus makes possible to take both measurements alternately and in rapid succession during same heating cycle, thereby reducing distortion.

Zoltan, Leslie D.↗

Eclipse-related measurements of middle-atmosphere electrical parameters

Measurements of electrical conductivity and its constituent parameters, charge density and ion mobility, are presented for the solar eclipse rocket campaign conducted at Red Lake, Ontario, Canada. Three parachute-borne probes (two Gerdien condensers and a blunt probe) were flown during the eclipse which occurred on 26 February 1979. Additional payloads launched at other times provided important supplemental background measurements. The entire launch series occurred during aurorally active conditions, as indicated by the probe measurements. Specifically, positive conductivity enhancements above 45 km demonstrate the dominance of auroral ionization as a source for positive ions in the region. Such effects evidenced during the eclipse make it difficult to determine the extent to which the decrease in positive conductivity above 60 km is eclipse-related. The negative conductivity component associated with free electrons displays solar dependence both during the eclipse and for the other measurement periods. In spite of the aurorally active conditions, rapid electron loss was observed during totality, thus indicating the importance of non-ionizing solar effects on electrons in the region.

Mitchell, J. D.↗

Low-frequency (f less than about 1 Hz) stratospheric electrical noise measured by balloon-borne sensors

Low-frequency (f less than about 1 Hz) stratospheric electrical noise is occasionally observed by balloon-borne sensors. The phenomenon occurs 1-3 percent of the time, with maximum incidence during the morning hours. It appears to be related to fluctuations of the electrical conductivity of the medium around the balloons, produced by air turbulence due to the wind shear and/or gravity waves.

Iversen, I. B.↗

Electric field measurements at the magnetopause. I Observation of large convective velocities at rotational magnetopause discontinuities

Large convective electric fields of the order of 10 mV/m (sometimes as high as 22 mV/m) are observed at rotational magnetopause discontinuities. These observations were made with the long cylindrical (179-m base line) probes carried on the ISEE 1 satellite. These electric field observations yield convective velocity magnitudes (equal to the cross product of the vector E and the vector B, the latter divided by the square of the magnitude of B) of the order of 150 km/s. In this format for the convective velocity magnitudes, some of these observations are similar to the high speed plasma velocity observations that were made at the magnetopause with the plasma experiment carried on the ISEE 1 satellite. It is shown that, for many of these magnetopause crossings, there exists a special moving coordinate system where the observed electric fields vanish. Such a unique reference system is often used in theoretical studies of magnetic discontinuities. This special coordinate system does not move at the local plasma velocity but moves instead at a velocity intermediate between the convective velocity and the local Alfven velocity. It is used here as a diagnostic tool for the experimental investigation of rotational discontinuities at the magnetopause.

Aggson, T. L.↗

Electric field measurements during supercharging events on the MAIMIK rocket experiment

Data are presented on the evolution of electric field structures near the MAIMIK mother-daughter tethered rocket during active electron emissions from the rocket, which consisted of two separately instrumented payload sections which were detached in-flight. The results of the E field data analysis show that the temporal behavior of the fields was consistent with ion responses to the rapid charging of the active payload. A qualitative model of the interaction between the active payload and the ambient plasma background is developed to explain the electric field data, including the apparent causal relationship between the radial and tangential impulse components.

Denig, W. F.↗