Search NASASearch

SEARCH · Search NASA

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A laboratory investigation of electromagnetic bias in sea level measurements by microwave altimeters

To contribute to a better understanding of the electromagnetic bias in radar altimetry, a series of experiments was conducted using a focused beam radar set at 13.5-GHz frequency. For pure wind wave fields, the authors found the bias to be a quadratic function of each of the commonly used parameters, namely, the significant wave height, the wind speed, the water elevation skewness, and significant slope. The bias divided by the significant wave height is a linear function of these parameters. The coefficients in bias representation as a function of either the significant wave height or the wind speed are significantly different from values obtained in field experiments. This led to the conclusion that none of the latter parameters can be taken solely to account for all observed bias variations. Instead, dimensionless parameters such as the wave skewness or a dimensionless wave height are shown to be more appropriate.

Branger, H.

Space shuttle electromagnetic environment experiment. Phase A: Definition study

A program is discussed which develops a concept for measuring the electromagnetic environment on earth with equipment on board an orbiting space shuttle. Earlier work on spaceborne measuring experiments is reviewed, and emissions to be expected are estimated using, in part, previously gathered data. General relations among system parameters are presented, followed by a proposal on spatial and frequency scanning concepts. The methods proposed include a nadir looking measurement with small lateral scan and a circularly scanned measurement looking tangent to the earth's surface at the horizon. Antenna requirements are given, assuming frequency coverage from 400 MHz to 40 GHz. For the low frequency range, 400-1000 MHz, a processed, thinned array is proposed which will be more fully analyzed in the next phase of the program. Preliminary hardware and data processing requirements are presented.

Haber, F.

EPOP Diagnostics and Data Acquisition

This paper describes the diagnostics that have been selected for the first flight of the Electric Propulsion Orbital Platform (EPOP-1), in which a 1.8 kW hydrazine arcjet will be flown and tested on the Wake Shield Facility. These diagnostics are: Langmuir probe measurements and video of the arcjet plume; three types of electromagnetic noise measurements; measurement of the voltage-current characteristic of the arc at different feed pressures; and measurement of other performance parameters such as pressures and temperatures of arcjet system components, thrust, and specific impulse. Also, the approach to data acquisition and control of the experiment is described.

Ruyten, W. M.

Benchmark radar targets for the validation of computational electromagnetics programs

Results are presented of a set of computational electromagnetics validation measurements referring to three-dimensional perfectly conducting smooth targets, performed for the Electromagnetic Code Consortium. Plots are presented for both the low- and high-frequency measurements of the NASA almond, an ogive, a double ogive, a cone-sphere, and a cone-sphere with a gap.

Woo, Alex C.

A laboratory study of the electromagnetic bias of rough surface scattering by water waves

The design, development, and use of a focused-beam radar to measure the electromagnetic bias introduced by the scattering of radar waves by a roughened water surface are discussed. The bias measurements were made over wide ranges of environmental conditions in a wavetank laboratory. Wave-elevation data were provided by standard laboratory capacitance probes. Backscattered radar power measurements coincident in time and space with the elevation data were produced by the radar. The two data sets are histogrammed to produce probability density functions for elevation and radar reflectivity, from which the electromagnetic bias is computed. The experimental results demonstrate that the electromagnetic bias is quite variable over the wide range of environmental conditions that can be produced in the laboratory. The data suggest that the bias is dependent upon the local wind field and on the amplitude and frequency of any background wave field that is present.

Parsons, Chester L.

W-Band Transmission MeasurementS and X-Band Dielectric Properties Measurements for a Radome Material Sample

This paper describes measurements which were performed on a sample of radome material in the Electromagnetic Properties Measurements Laboratory (EPML). The purpose of the measurements described in this paper was to determine the one-way transmission loss through the flat panel of radome material for a frequency range of 84 to 94 GHz, for varying incidence angles. The panel, which was manufactured by Norton Performance Plastics Corporation, was provided to the EPML by TRW. The size of the panel is 40 in x 36 in x 0.422 in and consists of a foam material with one side coated with a smooth white coating (this side will be referred to as the front side). The dielectric properties of the foam material from the inside of the panel were also determined at X-band (8.2-12.4 GHz). The W-band free space measurements are presented first, followed by the X-band dielectric properties measurements.

Cravey, Robin L.

Description of an aircraft lightning and simulated nuclear electromagnetic pulse (NEMP) threat based on experimental data

Lightning data obtained by measuring the surface electromagnetic fields on a CV-580 research aircraft during 48 lightning strikes between 1500 and 18,000 feet in central Florida during the summers of 1984 and 1985, and nuclear electromagnetic pulse (NEMP) data obtained by surface electromagnetic field measurements using a 1:74 CV-580 scale model, are presented. From one lightning event, maximum values of 3750 T/s for the time rate of change of the surface magnetic flux density, and 4.7 kA for the peak current, were obtained. From the simulated NEMP test, maximum values of 40,000 T/s for the time rate of change of the surface magnetic flux density, and 90 A/sq m for the total normal current density, were found. The data have application to the development of a military aircraft lightning/NEMP standard.

Rustan, Pedro L., Jr.

Multi-frequency signatures of space-leader evolution in negative cloud-to-ground lightning stepped leaders

In this study, we examined 364 space leaders in 18 negative natural cloud-to-ground lightning strokes whose stepped leaders created new channels to ground. All strokes were captured on ultra-high-speed video cameras operating at frame rates ranging from 400k to 783k frames per second. Additionally, broadband electromagnetic field measurements were available for a subset of these strokes. The median space leader inception-to-attachment-point length and retrograde propagation speed towards the pre-existing leader channel (PELC) were 8.2 m and 4.0 x 10 6 m/s, respectively. Space leader lengths were longer and retrograde propagation speeds faster for return strokes with higher peak currents. This is likely due to the relative proximity of space leader inception points to the PELC, which makes the electric field produced by the PELC line charge density one of the primary factors in determining space leader characteristics. Space leader characteristics were weakly related to their inception altitude. We observed bursts of very high frequency (VHF) emissions preceding, by around 0.5 – 1 μs, electric field leader-step pulses; visible-frequency-range luminosity pulses started during the step pulses. The median downward leader propagation speed for all 18 strokes was 4.3 x 10 5 m/s; leader propagation speeds were generally faster for return strokes with higher peak currents. Also, leaders appeared to accelerate (on their way to ground) at altitudes lower than about 200 and 1000 m above ground level for strokes in the 10 – 60 and 84 – 228 kA peak current ranges, respectively.

54 ENVIRONMENTAL SCIENCES

Efficiency measurements of reflection gratings in the 100-300-A band

Zero-order and first-order efficiencies of plane diffraction grazings over the 100-300-A band have been measured using the NRL beamline facility at the National Synchrotron Light Source. Measurements were taken at grating angles of 5, 10, and 15 deg, and the incident radiation was polarized primarily in the transverse magnetic mode. Four (three laminar, one blazed) of the gratings were ion etched in high quality quartz blanks, overcoated with 200 A of gold. A fifth (blazed) grating was ruled in gold. The line densities are 1000, 2000, and 3600 grooves/mm for those with laminar profiles. Both blazed gratings have a blaze angle of 8 deg and line densities of 3600 grooves/mm. Measured first-order efficiencies up to 15 percent were obtained for the laminar gratings and up to 8 percent was obtained for the ion-etched blazed grating. Much lower efficiencies (not greater than 2 percent) were measured for the ruled grating. A computer program was written to calculate grating efficiencies using a full electromagnetic model. Measured efficiencies of the ion-etched gratings agree well with predicted values, but the measured first-order efficiency of the ruled grating is much lower than predicted.

Meekins, John F.

Radiation Pressure Measurements on Micron Size Individual Dust Grains

Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2 micron to 6.82 micron range and irradiating them from above with laser radiation focused to beam-widths of approx. 175-400 micron, at ambient pressures approx. 10(exp -3) to 10(exp -4) torr. The downward displacement of the particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of silica and the corresponding extinction and scattering efficiencies.

Abbas, M. M.

Radiation Pressure Measurements on Micron-Size Individual Dust Grains

Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2- to 6.82-micron range and irradiating them from above with laser radiation focused to beam widths of approximately 175- 400 microns at ambient pressures particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of SiO2 and the corresponding extinction and scattering efficiencies.

Abbas, M. M.

High precision measurements of the proton elastic electromagnetic form factors and their ratio at 𝑄 2 = 0.50, 2.64, 3.20, and 4.10 GeV 2

The advent of high-intensity, high-polarization electron beams led to significantly improved measurements of the ratio of the proton’s charge to electric form factors, 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 . However, high-𝑄 2 measurements of this ratio yielded significant disagreement with extractions based on unpolarized scattering measurements, raising questions about the reliability of the measurements and consistency of the techniques. Jefferson Lab experiment E01-001 was designed to provide a high precision extraction of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 from unpolarized cross-section measurements using a modified version of the Rosenbluth separation technique to allow for a more precise comparison with polarization data. Rosenbluth separations involve precise measurements of the angular dependence of the elastic 𝑒−𝑝 cross section at fixed momentum transfer, 𝑄 2 . Conventional Rosenbluth separations detect the scattered electron, requiring the comparisons of measurements with very different detected electron energy and rate for electrons at different angles. Our ‘‘super-Rosenbluth’’ measurement detected the struck proton, rather than the scattered electron to extract the elastic 𝑒−𝑝 cross section. This yielded a fixed momentum for the detected particle and dramatically reduced variation of the cross section with angle, significantly reducing rate- and momentum-dependent corrections and uncertainties. We measure the cross section vs angle with high relative precision, allowing for extremely high precision extractions of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 at 𝑄 2 = 2.64, 3.20, and 4.10 GeV 2 . Our results are consistent with traditional Rosenbluth extractions, but with much smaller corrections and systematic uncertainties, comparable to the uncertainties from polarization measurements. Our data confirm the discrepancy between Rosenbluth and polarization extractions of the proton form factor ratio using an improved Rosenbluth extraction that yields smaller and less-correlated uncertainties than those typical of previous Rosenbluth extractions. Here, we compare our results to calculations of two-photon exchange effects and find that the observed discrepancy can be relatively well explained by such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Microwave radiometric systems.

Microwave radiometers measure thermal electromagnetic radiation at frequencies ranging over the entire radio spectrum, from audio to infrared. The temperatures of black-body radiators can be measured with sensitivities better than 0.01 K, and with absolute accuracies better than 0.5 K. Radiometric systems have been built with as many as 400 independent spectral channels. Frequency resolutions range from hertz to gigahertz; and integration times range from microseconds to hours. Radiometric systems have operated reliably on the ground, and in balloons, aircraft, and spacecraft, including the 1962 Mariner 2 planetary probe to Venus.

Barath, F. T.

The measurement of lightning environmental parameters related to interaction with electronic systems

The measurement of electromagnetic fields and related quantities in a lightning environment is a challenging problem, especially at high frequencies and/or in the immediate vicinity of the lightning arcs and corona. This paper reviews the techniques for accomplishing such measurements in these regimes with examples. These sensors are often the same as for the nuclear electromagnetic pulse (EMP), but significant differences also appear.

Baum, C. E.

Overview of recent results from the STAR experiment

We highlight the STAR experiment’s recent measurements on electromagnetic and hard probes of nuclear collisions, which inform the field’s understanding of these physical phenomena and by extension QCD. Results on vector meson production from the high electromagnetic fields in glancing heavy-ion collisions are presented. Observables related to jets, high-momentum hadrons, heavy quarks and quarkonia in vacuum and their modification in head-on heavy-ion collisions are also presented. Studies using electromagnetic probes of the medium created in these collisions are presented as well. Finally, we conclude and give an outlook for STAR data-taking and measurements in the coming years.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

An electromagnetic noncontacting sensor for thickness measurement in a dispersive medium

This paper describes a general purpose imaging technology developed by the U.S. Bureau of Mines (USBM) that, when fully implemented, will solve the general problem of 'seeing into the earth.' A first-generation radar coal thickness sensor, the RCTS-1, has been developed and field-tested in both underground and highwall mines. The noncontacting electromagnetic technique uses spatial modulation created by moving a simple sensor antenna in a direction along each axis to be measured while the complex reflection coefficient is measured at multiple frequencies over a two-to-one bandwidth. The antenna motion imparts spatial modulation to the data that enables signal processing to solve the problems of media, target, and antenna dispersion. Knowledge of the dielectric constant of the media is not necessary because the electrical properties of the media are determined automatically along with the distance to the target and thickness of each layer of the target. The sensor was developed as a navigation guidance sensor to accurately detect the coal/noncoal interface required for the USBM computer-assisted mining machine program. Other mining applications include the location of rock fractures, water-filled voids, and abandoned gas wells. These hazards can be detected in advance of the mining operation. This initiating technology is being expanded into a full three-dimensional (3-D) imaging system that will have applications in both the underground and surface environment.

Chufo, Robert L.