At least 127 records · Page 7

London Penetration Depth Measurements Using Tunnel Diode Resonators

The London penetration depth λ is the basic length scale for electromagnetic behavior in a superconductor. Precise measurements of λ as a function of temperature, field and impurity scattering have been instrumental in revealing the nature of the order parameter and pairing interactions in a variety of superconductors discovered over the past decades. Here we recount our development of the tunnel-diode resonator technique to measure λ as function of temperature and field in small single crystal samples. Furthermore, we discuss the principles and applications of this technique to study unconventional superconductivity in the copper oxides and other materials such as iron-based superconductors. The technique has now been employed by several groups world-wide as a precision measurement tool for the exploration of new superconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser autodyne registration of nanodisplacements under laser wavelength modulation

The formation of an autodyne interference signal under the current modulation of the laser radiation wavelength is studied. For the first time we propose a method for determining the stationary phase of the autodyne signal based on the analysis of the low-frequency spectrum of the laser autodyne system. The results of measuring nanodisplacements of the electromagnetic translator by the ratio of the autodyne signal spectral components under harmonic current modulation of the laser autodyne wavelength are presented. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation and Experimental Results of Interdigital Capacitor (IDC) Sensors to Monitor Insulation Degradation of Cables

The efficacy of using interdigital capacitor (IDC) sensors to monitor cable insulation aging was studied through electromagnetic simulations and experimental measurements. Simulation results on both planar and conformal dielectric materials indicated that IDCs on thin substrates and with conducting backplanes provide superior performance in terms of higher capacitance. An airgap study showed that even a very small airgap between the sensor and the cable’s insulation results in significant reduction in capacitance; therefore, airgaps should be minimized. Finally, cables that underwent accelerated aging exposure in an oven were tested using fabricated IDC sensors. Measurement results showed a 12.5% increase in capacitance when the IDC was pressed against the insulation versus a 91.3% increase in capacitance when the IDC was pressed against the jackets of the cables for cable specimens ranging from unaged to aged 35 days.

Cable NDE, Interdigital Capacitance↗

Recording interfacial currents on the subnanometer length and femtosecond time scale by terahertz emission

Electron dynamics at interfaces is a subject of great scientific interest and technological importance. Detailed understanding of such dynamics requires access to the angstrom length scale defining interfaces and the femtosecond time scale characterizing interfacial motion of electrons. In this context, the most precise and general way to remotely measure charge dynamics is through the transient current flow and the associated electromagnetic radiation. Here, we present quantitative measurements of interfacial currents on the subnanometer length and femtosecond time scale by recording the emitted terahertz radiation following ultrafast laser excitation. We apply this method to interlayer charge transfer in heterostructures of two transition metal dichalcogenide monolayers less than 0.7 nm apart. We find that charge relaxation and separation occur in less than 100 fs. This approach allows us to unambiguously determine the direction of current flow, to demonstrate a charge transfer efficiency of order unity, and to characterize saturation effects.

36 MATERIALS SCIENCE↗

Measurement of the Hubble constant with high-energy neutrinos

Measuring distances in the Universe is one of the hardest problems in physics and astronomy. Almost every distance probe relies on photons, whose propagation across cosmic distances introduces extinction, absorption, scattering, and radiative-transfer effects. Neutrinos suffer none of these and propagate unattenuated through dust, intergalactic medium, and dense source environments alike. We introduce a new distance-ladder method for measuring the Hubble constant $H_0$ using high-energy astrophysical neutrinos from point sources as standardizable candles, and report its first observational realization. Using 12 X-ray-selected Seyfert galaxies for which IceCube reports significant per-source neutrino excesses in its 14-year public point-source release, we exploit the disk-corona correlation $L_ν= κ\, L_X^β$ between neutrino and X-ray luminosities to construct a neutrino distance ladder anchored by non-redshift distances to NGC 1068 (Cepheid + TRGB). We find $H_0 = 49^{+40}_{-30}\,\mathrm{km\,s^{-1}\,Mpc^{-1}}$ and $β= 0.67^{+0.16}_{-0.25}$ (68% credible intervals), with the corona slope disfavoring the calorimetric limit $β= 1$ at ${\sim}2σ$. The result is consistent with existing $H_0$ determinations from Planck and SH0ES within 1$σ$. While the uncertainty on $H_0$ is large, the measurement is free of electromagnetic propagation systematics and demonstrates the viability of neutrinos as a novel cosmographical probe.

Herrera, Gonzalo [MIT, MKI; Harvard U.] (ORCID:000↗

MeV Scale Physics in MicroBooNE

This thesis presents the reconstruction and measurement of low-energy electromagnetic activity with beam neutrino interactions within the MicroBooNE Liquid Argon Time Projection Chamber (LArTPC). LArTPCs have proven to be excellent detectors to measure neutrino interaction cross sections and are being used to perform precision measurements of neutrino oscillation parameters. The work presented in this thesis has demonstrated unprecedentedly low, sub-MeV energy thresholds that have increased sensitivity of LArTPCs to detect neutrino interactions from core collapse supernovae and Muon Decay at Rest (µDAR). In addition, such low thresholds have also increased measurement sensitivity for interactions from Beyond the Standard Model (BSM) candidates such as millicharged particles and nuclear and electron recoils from dark matter candidate particles. On the reconstruction side, this work has established an energy resolution of 6.3% for electromagnetic activity i the 0-5 MeV energy range within the MicroBooNE LArTPC. Additionally this work presents the quantitative analysis of the low-energy activity emanating from G-10 support ribs in MicroBooNE and discusses how such activity could be a problematic source of background for low-energy physics analyses in future neutrino detectors such as the Deep Underground Neutrino Experiment (DUNE).

Bhat, Avinay↗

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N↗

Laser and Electron Beam Technology for Parity Violating Electron Scattering Measurements

Parity violating electron scattering (PVES) is a precision tool used in a broad program of experiments which include studying the structure of protons and nuclei and searching for new Beyond the Standard Model (BSM) physics. In parity violation electron scattering experiments, a longitudinally polarized electron beam is incident on an unpolarized target. The sign of the longitudinal polarization is changed (making a parity transformation), and the fractional rate difference between right and left helicity states, dσ R and dσ L , is measured. An interference between the electromagnetic and weak amplitudes, M γ and M Z respectively, gives rise to a parity violating asymmetry A PV = $\frac{σ_{R}-σ_{L}}{σ_{R}-σ_{L}}$, defined by the fractional rate difference between right and left helicity states. A PV can be measured to extraordinarily high precision and is proportional to the ratio of the weak and electromagnetic amplitudes. This thesis highlights three such PVES experiments as well as a new polarized beam source which will improve their precision. The PVES experiments are PREX-II, MOLLER, and a 12 C transverse asymmetry measurement at Mainz. Chapters 1-3 of this thesis cover introductions to MOLLER and PREX-II, Chapter 4 contains the results of the 12 C transverse asymmetry measurement at Mainz, and Chapters 5-6 contain the original work performed by this author. PREX-II, the Lead Radius Experiment, measures the weak skin of the 208 Pb nucleus, provides a clean measurement of R N , the RMS radius of neutrons in a heavy nucleus, and constrains the equation of state (EOS) of highly dense matter which is important for describing neutron star structure, heavy ion collisions, and atomic parity violation experiments. The 12 C transverse asymmetry measurement at Mainz, and the future Mainz program of measuring the 208 Pb transverse asymmetry as well, addresses an important systematic correction for PREX and other PVES experiments preformed with heavy-nuclei. MOLLER (Measurement Of Lepton Lepton Electroweak Reaction) is an extremely precise PVES experiment searching for new neutral currents in electron-electron scattering. It’s called MOLLER because it will measure A PV in the Moller ee scattering process, and will infer the weak charge of the electron $Q^e_W$ to extremely high precision. MOLLER is sensitive to new Beyond the Standard Model physics at MeV and multi-TeV scales and will serve as an indirect complementary measurement to direct searches at high energy colliders. To achieve high precision measurements on A PV for MOLLER, we have developed an innovative Rubidium Titanyl Phosphate (RTP) Pockels cell in the polarized source to satisfy both statistical and systematic requirements as regards the electron beam produced. This new ultra-fast RTP cell design uses electric field gradients to provide unprecedented control over helicity correlated beam asymmetries and has been demonstrated to be capable of producing precisely controlled polarized electron beam at Jefferson Laboratory, controlling beam steering down to the nm-level. The precision reached with the RTP cell offers sufficient control over and minimization of helicity correlated beam asymmetries to perform PREX II. The RTP Pockels cell system will provide fast flipping and suitable control helicity correlated beam asymmetries and parity quality beam for the future MOLLER experiment, providing an unprecedented precision on the electron weak charge and electroweak mixing angle.

Palatchi, Caryn↗

Experimental Limit on Nonlinear State-Dependent Terms in Quantum Theory

Linear time evolution is one of the fundamental postulates of quantum theory. Past theoretical attempts to introduce nonlinearity into quantum evolution have violated causality. However, a recent theory has introduced nonlinear state-dependent terms in quantum field theory, preserving causality [D. E. Kaplan and S. Rajendran, Phys. Rev. D 105, 055002 (2022)]. We report the results of an experiment that searches for such terms. Our approach, inspired by the Everett many-worlds interpretation of quantum theory, correlates a binary macroscopic classical voltage with the outcome of a projective measurement of a quantum bit, prepared in a coherent superposition state. Measurement results are recorded in a bit string, which is used to control a voltage switch. Presence of a nonzero voltage reading in cases of no applied voltage is the experimental signature of a nonlinear state-dependent shift of the electromagnetic field operator. We implement blinded measurement and data analysis with three control bit strings. Control of systematic effects is realized by producing one of the control bit strings with a classical random-bit generator. The other two bit strings are generated by measurements performed on a superconducting qubit in an IBM Quantum processor and on a N 15 nuclear spin in a nitrogen-vacancy center in diamond. Our measurements find no evidence for electromagnetic quantum state-dependent nonlinearity. We set a bound on the parameter that quantifies this nonlinearity | ε γ | < 4.7 × 10 - 11 , at 90% confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Novel Technique Applying Spectral Estimation to Johnson Noise Thermometry

Johnson noise thermometry is one of many important measurement techniques used to monitor the safety levels and stability in a nuclear reactor. However, this measurement is very dependent on the minimal electromagnetic environment. Properly removing unwanted electromagnetic interference (EMI) is critical for accurate drift-free temperature measurements. The two techniques developed by Oak Ridge National Laboratory (ORNL) to remove transient and periodic EMI are briefly discussed here. Spectral estimation is a key component in the signal processing algorithm used for EMI removal and temperature calculation. The cross-power spectral density is a key component in the Johnson noise temperature computation. Applying either technique requires the simple addition of electronics and signal processing to existing resistive thermometers. With minimal installation changes, the system discussed here can be installed on existing nuclear power plants. The Johnson noise system developed is tested at three locations: ORNL, Sandia National Laboratory, and the Tennessee Valley Authority’s Kingston Fossil Plant. Each of these locations enabled improvement on the EMI removal algorithm. Finally, the conclusions made from the results at each of these locations is discussed, as well as possible future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparing simulated and observed EMIC wave amplitudes using in situ Van Allen Probes’ measurements

In this study, we perform a statistical study calculating electromagnetic ion cyclotron (EMIC) wave amplitudes based off in situ plasma measurements taken by the Van Allen Probes’ (1.1–5.8 R e ) Helium, Oxygen, Proton, Electron (HOPE) instrument. Calculated wave amplitudes are compared to EMIC waves observed by the Electric and Magnetic Field Instrument Suite and Integrated Science on board the Van Allen Probes during the same period. The survey covers a 22-month period (1 November 2012 to 31 August 2014), a full Van Allen Probe magnetic local time (MLT) precession. The linear theory proxy was used to identify EMIC wave events with plasma conditions favorable for EMIC wave excitation. Two hundred and thirty-two EMIC wave events (103 H + -band and 129 He + -band) were selected for this comparison. Nearly all events selected are observed beyond L = 4. Results show that calculated wave amplitudes exclusively using the in situ HOPE measurements produce amplitudes too low compared to the observed EMIC wave amplitudes. Hot proton anisotropy (Ahp) distributions are asymmetric in MLT within the inner (L < 7) magnetosphere with peak (minimum) A hp , ~0.81 to 1.00 (~0.62), observed in the dawn (dusk), 0000 < MLT ≤ 1200 (1200 < MLT ≤ 2400), sectors. Measurements of A hp are found to decrease in the presence of EMIC wave activity. A hp amplification factors are determined and vary with respect to EMIC wave-band and MLT. Lastly, He + -band events generally require double (quadruple) the measured A hp for the dawn (dusk) sector to reproduce the observed EMIC wave amplitudes.

58 GEOSCIENCES↗

Impact of electron lifetime on electromagnetic shower separation : Impacto do tempo de vida médio dos elétrons na separação de chuveiros eletromagnéticos

Neutrinos are superabundant particles in the universe but rarely interact with matter. Previous experiments noticed an excess of neutrinos in the low energy range that could be connected to the existence of a fourth type of neutrino: the sterile neutrino. This excess could be because of the new neutrino or just because of the incapacity of previous experiments on distinguishing electromagnetic showers initiated by electrons and photons. So, new experiments using liquid argon are being developed and bet on the liquid argon time projection chambers (LArTPCs) to find answers for these and other still open questions about these mysterious particles. LArTPCs represent today the future for neutrinos research. They have high spatial resolution and great calorimetric capacity. Many experiments are being planned using this technique; consequently, it is necessary to understand the particle’s interactions in liquid argon completely. The LArIAT experiment was created to help in the char acterization of this kind of detector’s response to charged particles that are expected to come out of neutrino interactions. The detector is exposed to a charged particle beam and receives a high number of electrons, making this a perfect experiment to help in the study of electromagnetic shower separation. To correctly identify the interactions and to collect the maximum information about them, the liquid argon that is utilized has to be ultra-pure. In this thesis, the process used on LArIAT to monitor the argon’s purity using cosmic muons is described, as well as the impact of this measurement on the separation of electromagnetic showers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the inclusive isolated photon production cross section in p p collisions at $\sqrt{s}$ =7 TeV

The production cross section of inclusive isolated photons has been measured by the ALICE experiment at the CERN LHC in pp collisions at a centre-of-momentum energy of √s= 7 TeV. The measurement is performed with the electromagnetic calorimeter EMCal and the central tracking detectors, covering a range of |η| < 0.27 in pseudorapidity and a transverse momentum range of 10< p γ T <60 GeV/c. The result extends the p T coverage of previously published results of the ATLAS and CMS experiments at the same collision energy to smaller p T . The measurement is compared to next-to-leading order perturbative QCD calculations and to the results from the ATLAS and CMS experiments. All measurements and theory predictions are in agreement with each other.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗