QIS for Applied Quantum Field Theory

Precision predictions in HEP and non-equilibrium dynamics in the early universe require quantum computational technologies. Future quantum devices offer the possibility of performing these, complementing lattice quantum chromodynamics (QCD) studies on classical computers. We are investigating many aspects of the quantum simulation of quantum field theories. Specific topics include simulation-suitable formulations of gauge theories, state preparation, time evolution, extracting HEP-related observables from simulations, quantum error correction (QEC), and entanglement. We are exploring strategies for simulation of scattering in QFTs, and dynamics of the early Universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Logical error rates for the surface code under a mixed coherent and stochastic circuit-level noise model inspired by trapped ions

With fault-tolerant quantum computing (FTQC) on the horizon, it is critical to understand sources of logical errors in plausible hardware implementations of quantum error-correcting codes. Detailed error modeling of computational instructions on particular FTQC architectures will enable the better prediction of error propagation in FT-encoded quantum circuits while revealing where greater attention is needed in hardware design. In this work, we consider logical error rates for the surface code implemented on a hypothetical grid-based trapped-ion quantum charge-coupled device architecture. Specifically, we construct logical channels for the idling surface code and examine its diamond error under a mixed coherent and stochastic circuit-level noise model inspired by trapped ions. We include the coherent dephasing noise that is known to accumulate during physical qubit idling and transport in these systems, determining idling and transport durations using the time-resolved output of an open-source trapped-ion surface code compiler. To estimate expectation values of logical Pauli observables following hardware circuits containing non-Clifford sources of noise, we utilize a Monte Carlo technique to sample from an underlying quasiprobability distribution of Clifford circuits that we independently simulate in a phase-sensitive fashion. We verify error suppression up to code distance 𝑑 = 11 at coherent dephasing rates near and below those of current-generation trapped-ion quantum computers and find that logical error rates align with those of analogous fully stochastic simulations in this regime. Exploring higher dephasing rates at 𝑑 = 3−5, we find evidence for growing coherent rotations about all three logical Pauli axes, increased diagonal logical error process matrix elements relative to those of stochastic simulations, and a reduced dephasing rate threshold. Overall, our work paves a way toward realistic hardware emulation of small fault-tolerant quantum processes, e.g., members of an FTQC instruction set.

Quantum benchmarking↗

Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography

Purpose: Spine stereotactic body radiotherapy (SBRT) involves tight planning margins and steep dose gradients to the surrounding organs at risk (OAR). This study aimed to assess intrafraction motion using cone beam computed tomography (CBCT) for spine SBRT patients treated using three immobilization devices. Methods and Materials: Setup accuracy using CBCT was retrospectively analyzed for 102 treated spinal metastases in 84 patients. Thoracic and lumbar spine patients were immobilized with either an evacuated cushion (EC, n = 24) or a semirigid vacuum body fixation (BF, n = 60). For cases treated at cervical/upper thoracic (thoracic [T]1-T3) vertebrae, a thermoplastic S-frame (SF) mask (n = 18) was used. Patient setup was corrected by using bony anatomy image registration and couch translations only (no rotation corrections) with shifts confirmed on verification CBCTs. Repeat imaging was performed mid- and post-treatment. Patient translational and rotational positioning data were recorded to calculate means, standard deviations (SD), and corresponding margins {+-} 2 SD for residual setup errors and intrafraction motion. Results: A total of 355 localizations, 333 verifications, and 248 mid- and 280 post-treatment CBCTs were analyzed. Residual translations and rotations after couch corrections (verification scans) were similar for all immobilization systems, with SDs of 0.6 to 0.9 mm in any direction and 0.9 Degree-Sign to 1.6 Degree-Sign , respectively. Margins to encompass residual setup errors after couch corrections were within 2 mm. Including intrafraction motion, as measured on post-treatment CBCTs, SDs for total setup error in the left-right, cranial-caudal, and anterior-posterior directions were 1.3, 1.2, and 1.0 mm for EC; 0.9, 0.7, and 0.9 mm for BF; and 1.3, 0.9, and 1.1 mm for SF, respectively. The calculated margins required to encompass total setup error increased to 3 mm for EC and SF and remained within 2 mm for BF. Conclusion: Following image guidance, residual setup errors for spine SBRT were similar across three immobilization systems. The BF device resulted in the least amount of intrafraction motion, and based on this device, we justify a 2-mm margin for the planning OAR and target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Practical quantum computation of chemical and nuclear energy levels using quantum imaginary time evolution and Lanczos algorithms

Various methods have been developed for the quantum computation of the ground and excited states of physical and chemical systems, but many of them require either large numbers of ancilla qubits or high-dimensional optimization in the presence of noise. The quantum imaginary-time evolution (QITE) and quantum Lanczos (QLanczos) methods proposed in Motta et al. (2020) eschew the aforementioned issues. In this study, we demonstrate the practical application of these algorithms to challenging quantum computations of relevance for chemistry and nuclear physics, using the deuteron-binding energy and molecular hydrogen binding and excited state energies as examples. With the correct choice of initial and final states, we show that the number of timesteps in QITE and QLanczos can be reduced significantly, which commensurately simplifies the required quantum circuit and improves compatibility with NISQ devices. We have performed these calculations on cloud-accessible IBM Q quantum computers. With the application of readout-error mitigation and Richardson error extrapolation, we have obtained ground and excited state energies that agree well with exact results obtained from diagonalization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correction to: Superconductor Electronics: Status and Outlook

The original version of the article unfortunately contained errors. The acronyms for conventional Josephson voltage standard (CJVS) and programmable Josephson voltage standard (PJVS) were misspelled as CVJC, PJVC and PVJC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensor-Assisted Fault Mitigation in Quantum Computation

We propose a method for assisting fault mitigation in quantum computation through the use of sensors, co-located near physical qubits. Specifically, we consider using transition edge sensors co-located on silicon substrates hosting superconducting qubits to monitor for energy injection from ionizing radiation that has been demonstrated to increase decoherence in transmon qubits. We generalize from these two physical device concepts and explore the potential advantages of co-located sensors to assist fault mitigation in quantum computation. In the simplest scheme, co-located sensors beneficially assist rejection of calculations potentially affected by environmental disturbances. Investigating the potential computational advantage further required development of an extension to the standard formulation of quantum error correction. In a specific case the standard three-qubit, bit flip quantum correction code, we show that given a 20% overall error probability per qubit, approximately 90% of repeated calculation attempts are correctable. However, when sensor-detectable errors account for 45% of overall error probability, the use of colocated sensors uniquely associated with independent qubits, boosts the fraction of correct final-state calculations to 96% at the cost of rejecting 7% of repeated calculation attempts.

Orrell, John L.↗

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗

High-speed Focal Plane Wave Front Sensing with an Optical Chopper

Focal plane wave front sensing and control is a critical approach to reducing noncommon path errors between a conventional astronomical adaptive optics (AO) wave front sensor (WFS) detector and a science camera. However, in addition to mitigating noncommon path errors, recent focal plane wave front sensing techniques have been developed to operate at speeds fast enough to enable "multi-WFS" AO, where residual atmospheric errors are further corrected by a focal plane WFS. Although a number of such techniques have been recently developed for coronagraphic imaging, here we present one designed for noncoronagraphic imaging. Utilizing conventional AO system components, this concept additionally requires (1) a detector imaging the focal plane of the WFS light source and (2) a pupil plane optical chopper device that is the noncommon path to the first WFS and is synchronized to the focal plane imager readout. These minimal hardware requirements enable the temporal amplitude modulation to resolve the sine ambiguity of even wave-front modes for low, mid, and high wave front spatial frequencies. Similar capabilities have been demonstrated with classical phase diversity by defocusing the detector, but such techniques are incompatible with simultaneous science observations. This optical chopping technique, however, enables science imaging at up to 50% duty cycle. In conclusion, we present both simulations and laboratory validation of this concept on SEAL, the Santa Cruz Extreme AO Laboratory testbed.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-E-9A-01: Risk Based Quality Management: TG100 In Action

One of the goals of quality management in radiation therapy is to gain high confidence that patients will receive the prescribed treatment correctly. To accomplish these goals professional societies such as the American Association of Physicists in Medicine (AAPM) has published many quality assurance (QA), quality control (QC), and quality management (QM) guidance documents. In general, the recommendations provided in these documents have emphasized on performing device-specific QA at the expense of process flow and protection of the patient against catastrophic errors. Analyses of radiation therapy incidents find that they are most often caused by flaws in the overall therapy process, from initial consult through final treatment, than by isolated hardware or computer failures detectable by traditional physics QA. This challenge is shared by many intrinsically hazardous industries. Risk assessment tools and analysis techniques have been developed to define, identify, and eliminate known and/or potential failures, problems, or errors, from a system, process and/or service before they reach the customer. These include, but are not limited to, process mapping, failure modes and effects analysis (FMEA), fault tree analysis (FTA), and establishment of a quality management program that best avoids the faults and risks that have been identified in the overall process. These tools can be easily adapted to radiation therapy practices because of their simplicity and effectiveness to provide efficient ways to enhance the safety and quality of treatment processes. Task group 100 (TG100) of AAPM has developed a risk-based quality management program that uses these tools. This session will be devoted to a discussion of these tools and how these tools can be used in a given radiotherapy clinic to develop a risk based QM program. Learning Objectives: Learn how to design a process map for a radiotherapy process. Learn how to perform a FMEA analysis for a given process. Learn what Fault tree analysis is all about. Learn how to design a quality management program based upon the information obtained from process mapping, FMEA and FTA.

60 APPLIED LIFE SCIENCES↗

Quantum computing hardware for HEP algorithms and sensing

Quantum information science harnesses the principles of quantum mechanics to realize computational algorithms with complexities vastly intractable by current computer platforms. Typical applications range from quantum chemistry to optimization problems and also include simulations for high energy physics. The recent maturing of quantum hardware has triggered preliminary explorations by several institutions (including Fermilab) of quantum hardware capable of demonstrating quantum advantage in multiple domains, from quantum computing to communications, to sensing. The Superconducting Quantum Materials and Systems (SQMS) Center, led by Fermilab, is dedicated to providing breakthroughs in quantum computing and sensing, mediating quantum engineering and HEP based material science. The main goal of the Center is to deploy quantum systems with superior performance tailored to the algorithms used in high energy physics. In this Snowmass paper, we discuss the two most promising superconducting quantum architectures for HEP algorithms, i.e. three-level systems (qutrits) supported by transmon devices coupled to planar devices and multi-level systems (qudits with arbitrary N energy levels) supported by superconducting 3D cavities. For each architecture, we demonstrate exemplary HEP algorithms and identify the current challenges, ongoing work and future opportunities. Furthermore, we discuss the prospects and complexities of interconnecting the different architectures and individual computational nodes. Finally, we review several different strategies of error protection and correction and discuss their potential to improve the performance of the two architectures. This whitepaper seeks to reach out to the HEP community and drive progress in both HEP research and QIS hardware.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MO-FG-202-09: Virtual IMRT QA Using Machine Learning: A Multi-Institutional Validation

Purpose: To validate a machine learning approach to Virtual IMRT QA for accurately predicting gamma passing rates using different QA devices at different institutions. Methods: A Virtual IMRT QA was constructed using a machine learning algorithm based on 416 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3mm with 10% threshold. An independent set of 139 IMRT measurements from a different institution, with QA data based on portal dosimetry using the same gamma index and 10% threshold, was used to further test the algorithm. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. Results: In addition to predicting passing rates with 3% accuracy for all composite plans using diode-array detectors, passing rates for portal dosimetry on per-beam basis were predicted with an error <3.5% for 120 IMRT measurements. The remaining measurements (19) had large areas of low CU, where portal dosimetry has larger disagreement with the calculated dose and, as such, large errors were expected. These beams need to be further modeled to correct the under-response in low dose regions. Important features selected by Lasso to predict gamma passing rates were: complete irradiated area outline (CIAO) area, jaw position, fraction of MLC leafs with gaps smaller than 20 mm or 5mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted Average Irregularity Factor, duty cycle among others. Conclusion: We have demonstrated that the Virtual IMRT QA can predict passing rates using different QA devices and across multiple institutions. Prediction of QA passing rates could have profound implications on the current IMRT process.

60 APPLIED LIFE SCIENCES↗

A method to improve accuracy and precision of water surface identification for photon depth dose measurements

The objective of this study is to present a method to reduce the setup error inherent in clinical depth dose measurements and, in doing so, to improve entrance dosimetry measurement reliability. Ionization chamber (IC) depth dose measurements are acquired with the depth scan extended into the air above the water surface. An inflection region is obtained in each resulting percent depth ionization (PDI) curve that can be matched against other measurements or to an inflection region obtained from an analogous Monte Carlo (MC) simulation. Measurements are made with various field sizes for the 6 and 18 MV photon beams, with and without a Pb foil in the beam, to determine the sensitivity of the dose inflection region to the beam conditions. The offset between reference and test data set inflection regions is quantified using two separate methods. When comparing sets of measured data, maxima in the second derivative of ionization are compared. When comparing measured data to MC simulation, the offset that minimizes the sum of squared differences between the reference and test curves in the ionization inflection region is found. These methods can be used to quantify the offset between an initial setup (test) position and the true surface (reference) position. The ionization inflection location is found to be insensitive to changes in field size, electron contamination, and beam energy. Data from a single reference condition should be sufficient to identify the surface location. The method of determining IC offsets is general and should be applicable to any IC and other radiation sources. The measurement method could reduce the time and effort required in the initial IC setup at a water surface as setup errors can be corrected offline. Given a reliable set of reference data to compare with, this method could increase the ability of quality assurance (QA) measurements to detect discrepancies in beam output as opposed to discrepancies in IC localization. Application of the measurement method standardizes the procedure for localizing cylindrical ICs at a water surface and thereby improves the reliability of measurements taken with these devices at all depths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-P-31: Dosimetric Effects of Roll and Pitch Corrections Using Robotic Table

Purpose: To quantify the dosimetric effect of roll and pitch corrections being performed by two types of robotic tables available at our institution: BrainLabTM 5DOF robotic table installed at VERO (BrainLab&MHI) dedicated SBRT linear accelerator and 6DOF robotic couch by IBA Proton Therapy with QFixTM couch top. Methods: Planning study used a thorax phantom (CIRSTM), scanned at 4DCT protocol; targets (IGTV, PTV) were determined according to the institutional lung site-specific standards. 12 CT sets were generated with Pitch and Roll angles ranging from −4 to +4 degrees each. 2 table tops were placed onto the scans according to the modality-specific patient treatment workflows. The pitched/rolled CT sets were fused to the original CT scan and the verification treatment plans were generated (12 photon SBRT plans and 12 proton conventional fractionation lung plans). Then the CT sets were fused again to simulate the effect of patient roll/pitch corrections by the robotic table. DVH sets were evaluated for all cases. Results: The effect of not correcting the phantom position for roll/pitch in photon SBRT cases was reducing the target coverage by 2% as maximum; correcting the positional errors by robotic table varied the target coverage within 0.7%. in case of proton treatment, not correcting the phantom position led to the coverage loss up to 4%, applying the corrections using robotic table reduced the coverage variation to less than 2% for PTV and within 1% for IGTV. Conclusion: correcting the patient position by using robotic tables is highly preferable, despite the small dosimetric changes introduced by the devices.

60 APPLIED LIFE SCIENCES↗

SU-E-P-54: Evaluation of the Accuracy and Precision of IGPS-O X-Ray Image-Guided Positioning System by Comparison with On-Board Imager Cone-Beam Computed Tomography

Purpose: The purpose of this study is to assess the positioning accuracy and precision of IGPS-O system which is a novel radiographic kilo-voltage x-ray image-guided positioning system developed for clinical IGRT applications. Methods: IGPS-O x-ray image-guided positioning system consists of two oblique sets of radiographic kilo-voltage x-ray projecting and imaging devices which were equiped on the ground and ceiling of treatment room. This system can determine the positioning error in the form of three translations and three rotations according to the registration of two X-ray images acquired online and the planning CT image. An anthropomorphic head phantom and an anthropomorphic thorax phantom were used for this study. The phantom was set up on the treatment table with correct position and various “planned” setup errors. Both IGPS-O x-ray image-guided positioning system and the commercial On-board Imager Cone-beam Computed Tomography (OBI CBCT) were used to obtain the setup errors of the phantom. Difference of the Result between the two image-guided positioning systems were computed and analyzed. Results: The setup errors measured by IGPS-O x-ray image-guided positioning system and the OBI CBCT system showed a general agreement, the means and standard errors of the discrepancies between the two systems in the left-right, anterior-posterior, superior-inferior directions were −0.13±0.09mm, 0.03±0.25mm, 0.04±0.31mm, respectively. The maximum difference was only 0.51mm in all the directions and the angular discrepancy was 0.3±0.5° between the two systems. Conclusion: The spatial and angular discrepancies between IGPS-O system and OBI CBCT for setup error correction was minimal. There is a general agreement between the two positioning system. IGPS-O x-ray image-guided positioning system can achieve as good accuracy as CBCT and can be used in the clinical IGRT applications.

60 APPLIED LIFE SCIENCES↗

Solovay-Kitaev Algorithm and Randomized Compilation Data Availability

This zipped folder contains simulation notebooks, simulated data, and experimental data from the QSCOUT trapped-ion device that were used in the publication "Solovay-Kitaev Algorithm and Randomized Compilation" (https://doi.org/10.1103/ll6m-dbl7). The raw data is in the form of measurement outcomes of simple tomographic quantum circuits that were executed on the QSCOUT device and simulated using JAQALPAQ. These data are used to create plots within the jupyter notebooks that were included in the publication.

Quantum benchmarking↗

Intrafraction Variation of Mean Tumor Position During Image-Guided Hypofractionated Stereotactic Body Radiotherapy for Lung Cancer

Purpose: Prolonged delivery times during daily cone-beam computed tomography (CBCT)-guided lung stereotactic body radiotherapy (SBRT) introduce concerns regarding intrafraction variation (IFV) of the mean target position (MTP). The purpose of this study was to evaluate the magnitude of the IFV-MTP and to assess target margins required to compensate for IFV and postonline CBCT correction residuals. Patient, treatment, and tumor characteristics were analyzed with respect to their impact on IFV-MTP. Methods and Materials: A total of 126 patients with 140 tumors underwent 659 fractions of lung SBRT. Dose prescribed was 48 or 60 Gy in 12 Gy fractions. Translational target position correction of the MTP was performed via onboard CBCT. IFV-MTP was measured as the difference in MTP between the postcorrection CBCT and the posttreatment CBCT excluding residual error. Results: IFV-MTP was 0.2 {+-} 1.8 mm, 0.1 {+-} 1.9 mm, and 0.01 {+-} 1.5 mm in the craniocaudal, anteroposterior, and mediolateral dimensions and the IFV-MTP vector was 2.3 {+-} 2.1 mm. Treatment time and excursion were found to be significant predictors of IFV-MTP. An IFV-MTP vector greater than 2 and 5 mm was seen in 40.8% and 7.2% of fractions, respectively. IFV-MTP greater than 2 mm was seen in heavier patients with larger excursions and longer treatment times. Significant differences in IFV-MTP were seen between immobilization devices. The stereotactic frame immobilization device was found to be significantly less likely to have an IFV-MTP vector greater than 2 mm compared with the alpha cradle, BodyFIX, and hybrid immobilization devices. Conclusions: Treatment time and respiratory excursion are significantly associated with IFV-MTP. Significant differences in IFV-MTP were found between immobilization devices. Target margins for IFV-MTP plus post-correction residuals are dependent on immobilization device with 5-mm uniform margins being acceptable for the frame immobilization device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ZFS on RBODs - Leveraging RAID Controllers for Metrics and Enclosure Management

Traditionally, the Lustre file system has relied on the ldiskfs file system with reliable RAID (Redundant Array of Independent Disks) storage underneath. As of Lustre 2.4, ZFS was added as a backend file system, with built-in software RAID, thereby removing the need of expensive RAID controllers. ZFS was designed to work with JBOD (Just a Bunch Of Disks) storage enclosures under the Solaris Operating System, which provided a rich device management system. Long time users of the Lustre file system have relied on the RAID controllers to provide metrics and enclosure monitoring and management services, with rich APIs and command line interfaces. This paper will study a hybrid approach using an advanced full featured RAID enclosure which is presented to the host as a JBOD, This RBOD (RAIDed Bunch Of Disks) allows ZFS to do the RAID protection and error correction, while the RAID controller handles management of the disks and monitors the enclosure. It was hoped that the value of the RAID controller features would offset the additional cost, and that performance would not suffer in this mode. The test results revealed that the hybrid RBOD approach did suffer reduced performance.

97 MATHEMATICS AND COMPUTING↗

Reliable voltage scaled links for compressed data

Systems, apparatuses, and methods for reliably transmitting data over voltage scaled links are disclosed. A computing system includes at least first and second devices connected via a link. In one implementation, if a data block can be compressed to less than or equal to half the original size of the data block, then the data block is compressed and sent on the link in a single clock cycle rather than two clock cycles. If the data block cannot be compressed to half the original size, but if the data block can be compressed enough to include error correction code (ECC) bits without exceeding the original size, then ECC bits are added to the compressed block which is sent on the link at a reduced voltage. The ECC bits help to correct for any errors that are generated as a result of operating the link at the reduced voltage.

42 ENGINEERING↗