Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXHALATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Cigarettes vs. e-cigarettes: Passive exposure at home measured by means of airborne marker and biomarkers

Background: There is scarce evidence about passive exposure to the vapour released or exhaled from electronic cigarettes (e-cigarettes) under real conditions. The aim of this study is to characterise passive exposure to nicotine from e-cigarettes' vapour and conventional cigarettes' smoke at home among non-smokers under real-use conditions. Methods: We conducted an observational study with 54 non-smoker volunteers from different homes: 25 living at home with conventional smokers, 5 living with nicotine e-cigarette users, and 24 from control homes (not using conventional cigarettes neither e-cigarettes). We measured airborne nicotine at home and biomarkers (cotinine in saliva and urine). We calculated geometric mean (GM) and geometric standard deviations (GSD). We also performed ANOVA and Student's t tests for the log-transformed data. We used Bonferroni-corrected t-tests to control the family error rate for multiple comparisons at 5%. Results: The GMs of airborne nicotine were 0.74 μg/m{sup 3} (GSD=4.05) in the smokers’ homes, 0.13 μg/m{sup 3} (GSD=2.4) in the e-cigarettes users’ homes, and 0.02 μg/m{sup 3} (GSD=3.51) in the control homes. The GMs of salivary cotinine were 0.38 ng/ml (GSD=2.34) in the smokers’ homes, 0.19 ng/ml (GSD=2.17) in the e-cigarettes users’ homes, and 0.07 ng/ml (GSD=1.79) in the control homes. Salivary cotinine concentrations of the non-smokers exposed to e-cigarette's vapour at home (all exposed ≥2 h/day) were statistically significant different that those found in non-smokers exposed to second-hand smoke ≥2 h/day and in non-smokers from control homes. Conclusions: The airborne markers were statistically higher in conventional cigarette homes than in e-cigarettes homes (5.7 times higher). However, concentrations of both biomarkers among non-smokers exposed to conventional cigarettes and e-cigarettes’ vapour were statistically similar (only 2 and 1.4 times higher, respectively). The levels of airborne nicotine and cotinine concentrations in the homes with e-cigarette users were higher than control homes (differences statistically significant). Our results show that non-smokers passively exposed to e-cigarettes absorb nicotine. - Highlights: • This is the first study of e-cigarette exposure at home under real-use conditions. • Airborne nicotine in homes with smokers were 5.7 times higher than in e-cig homes. • Cotinine of non-smokers exposed to e-cig and conventional cigarettes was similar. • Airborne nicotine in homes with e-cig users was higher than control homes. • Cotinine of non-smokers exposed to e-cig users was higher than in those no exposed.

54 ENVIRONMENTAL SCIENCES↗

The micro-environmental impact of volatile organic compound emissions from large-scale assemblies of people in a confined space

Large-scale assemblies of people in a confined space can exert significant impacts on the local air chemistry due to human emissions of volatile organics. Variations of air-quality in such small scale can be studied by quantifying fingerprint volatile organic compounds (VOCs) such as acetone, toluene, and isoprene produced during concerts, movie screenings, and sport events (like the Olympics and the World Cup). This review summarizes the extent of VOC accumulation resulting from a large population in a confined area or in a small open area during sporting and other recreational activities. Apart from VOCs emitted directly from human bodies (e.g., perspiration and exhaled breath), those released indirectly from other related sources (e.g., smoking, waste disposal, discharge of food-waste, and use of personal-care products) are also discussed. Although direct and indirect emissions of VOCs from human may constitute <1% of the global atmospheric VOCs budget, unique spatiotemporal variations in VOCs species within a confined space can have unforeseen impacts on the local atmosphere to lead to acute human exposure to harmful pollutants.

54 ENVIRONMENTAL SCIENCES↗

Personal exposure to fine particles (PM2.5) and respiratory inflammation of common residents in Hong Kong

Highlights: • Personal PM{sub 2.5} monitoring from 46 healthy adults with up to 6 repeated measurements were conducted. • Personal PM{sub 2.5} exposures were higher than ambient levels monitored by stations. • Mixed-effects model was applied to assess the relationship between air pollutants exposure and biomarker. • Significant associations were observed for the increased FeNO with personal exposure to PM{sub 2.5} and c-PAHs. Given the lack of research on the personal exposure to fine particles (PM{sub 2.5}) in Hong Kong, we examined the association between short-term personal exposure to PM{sub 2.5} and their constituents and inflammation in exhaled breath in a sample of healthy adult residents.

54 ENVIRONMENTAL SCIENCES↗

An Experimental Study of the Solubility of Rare Earth Chloride Salts (La, Nd, Er) in HCl Bearing Water Vapor from 350 – 425 °C

In this work, the solubilities of the rare earth chlorides REECl 3 , where REE = (La, Nd, Er), were measured in HCl bearing water vapor from 350 – 425°C with water partial pressures ranging from 8 – 170 bar. Solubility data were fit to the Pitzer-Pabalan quasi-chemical model in order to extract thermodynamic parameters for the formation of the gaseous REE-chloride-water clusters REECl 3 (H 2 O) n . The data show that the solubility of the REE chlorides are orders of magnitude higher than salts such as NaCl or CuCl at low water fugacities, despite their sublimation energies being substantially higher. This enhanced solubility is likely due to the high enthalpy associated with binding a single water molecule to form the species REECl 3 (H 2 O), with derived enthalpies ranging from –378 to –465 kJ/mol. Addition of further water molecules to form higher order clusters (n > 1) involves enthalpy changes of ~ -20 kJ/mol, and are in effect thermodynamically suppressed over the temperature range 350 – 425°C. Despite the enhanced solubility of small REECl 3 water clusters, simulations of boiling processes demonstrate that the REE show highly conservative behavior, partitioning strongly into the dense aqueous phase. Not surprisingly, the presence of phosphates in the system makes this effect even more pronounced, completely immobilizing the REE. This would reduce transport in both the vapor and aqueous phase to negligible levels. However, we suggest that vapor phase transport of the REE may play a significant role in systems having a relatively low partial pressure of water (below the saturation point), where the relatively high stability of the first hydrated REE chloride clusters (REECl 3 (H 2 O) and REECl 3 (H 2 O) 2 ) will give a preference for gas transport of the REE relative to other elements. This can likely happen in systems involving a gas/melt exchange in fumarolic exhalations, where water vapor discharges at relatively low (close to atmospheric) pressures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Multiple Breathing States Using a Multiple Instance Geometry Approximation (MIGA) in Inverse-Planned Optimization for Locoregional Breast Treatment

Purpose: Although previous work demonstrated superior dose distributions for left-sided breast cancer patients planned for intensity-modulated radiation therapy (IMRT) at deep inspiration breath hold compared with conventional techniques with free-breathing, such techniques are not always feasible to limit the impact of respiration on treatment delivery. This study assessed whether optimization based on multiple instance geometry approximation (MIGA) could derive an IMRT plan that is less sensitive to known respiratory motions. Methods and Materials: CT scans were acquired with an active breathing control device at multiple breath-hold states. Three inverse optimized plans were generated for eight left-sided breast cancer patients: one static IMRT plan optimized at end exhale, two (MIGA) plans based on a MIGA representation of normal breathing, and a MIGA representation of deep breathing, respectively. Breast and nodal targets were prescribed 52.2 Gy, and a simultaneous tumor bed boost was prescribed 60 Gy. Results: With normal breathing, doses to the targets, heart, and left anterior descending (LAD) artery were equivalent whether optimizing with MIGA or on a static data set. When simulating motion due to deep breathing, optimization with MIGA appears to yield superior tumor-bed coverage, decreased LAD mean dose, and maximum heart and LAD dose compared with optimization on a static representation. Conclusions: For left-sided breast-cancer patients, inverse-based optimization accounting for motion due to normal breathing may be similar to optimization on a static data set. However, some patients may benefit from accounting for deep breathing with MIGA with improvements in tumor-bed coverage and dose to critical structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy-Based Stereotactic Body Radiotherapy for Medically Inoperable Early-Stage Lung Cancer: Excellent Local Control

Purpose: To validate the use of stereotactic body radiotherapy (SBRT) using intensity-modulated radiotherapy (IMRT) beams for medically inoperable Stage I lung cancer. Methods and Materials: From February 2004 to November 2006, a total of 26 patients with 28 lesions received SBRT using a Novalis/BrainLAB system. Immobilization involved a Bodyfix vacuum cushion. A weighted abdominal belt limited respiratory excursion. Computed tomographic simulation images were acquired at rest, full inhalation, and full exhalation and were merged to generate an internal gross tumor volume (ITV). Dose was prescribed to cover the planning target volume (PTV), defined as PTV = ITV + 3-5 mm set-up margin. Heterogeneity corrections were used. Delivery of 50 Gy in five sequential fractions typically used seven nonopposing, noncoplanar beams. Image-guided target verification was provided by BrainLAB-ExacTrac. Results: Among the 26 patients, the mean age was 74 years (range, 49-88 years). Of the patients, 50% were male and 50% female. The median Karnofsky performance status was 70 (range, 40-100). The median follow-up was 30.9 months (range, 10.4-51.4 months). Tissue diagnosis was contraindicated in seven patients (26.9%). There were 22 T1 (78.6%) and six T2 (21.4%) tumors. The median conformality index was 1.38 (range, 1.12-1.8). The median heterogeneity index was 1.08 (range, 1.04-1.2). One patient (3.6%) developed acute Grade 3 dyspnea and one patient developed late Grade 2 chest wall pain. Actuarial local control and overall survival at 3 years were 94.4% and 52%, respectively. Conclusions: Use of IMRT-based delivery of SBRT using restriction of tumor motion in medically inoperable lung cancer demonstrates excellent local control and favorable survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Respiratory-Gated and Respiratory-Ungated Planning in Scattered Carbon Ion Beam Treatment of the Pancreas Using Four-Dimensional Computed Tomography

Purpose: We compared respiratory-gated and respiratory-ungated treatment strategies using four-dimensional (4D) scattered carbon ion beam distribution in pancreatic 4D computed tomography (CT) datasets. Methods and Materials: Seven inpatients with pancreatic tumors underwent 4DCT scanning under free-breathing conditions using a rapidly rotating cone-beam CT, which was integrated with a 256-slice detector, in cine mode. Two types of bolus for gated and ungated treatment were designed to cover the planning target volume (PTV) using 4DCT datasets in a 30% duty cycle around exhalation and a single respiratory cycle, respectively. Carbon ion beam distribution for each strategy was calculated as a function of respiratory phase by applying the compensating bolus to 4DCT at the respective phases. Smearing was not applied to the bolus, but consideration was given to drill diameter. The accumulated dose distributions were calculated by applying deformable registration and calculating the dose-volume histogram. Results: Doses to normal tissues in gated treatment were minimized mainly on the inferior aspect, which thereby minimized excessive doses to normal tissues. Over 95% of the dose, however, was delivered to the clinical target volume at all phases for both treatment strategies. Maximum doses to the duodenum and pancreas averaged across all patients were 43.1/43.1 GyE (ungated/gated) and 43.2/43.2 GyE (ungated/gated), respectively. Conclusions: Although gated treatment minimized excessive dosing to normal tissue, the difference between treatment strategies was small. Respiratory gating may not always be required in pancreatic treatment as long as dose distribution is assessed. Any application of our results to clinical use should be undertaken only after discussion with oncologists, particularly with regard to radiotherapy combined with chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)

Purpose: To assess the accuracy, reproducibility, and computational performance of deformable image registration algorithms under development at multiple institutions on common datasets. Methods and Materials: Datasets from a lung patient (four-dimensional computed tomography [4D-CT]), a liver patient (4D-CT and magnetic resonance imaging [MRI] at exhale), and a prostate patient (repeat MRI) were obtained. Radiation oncologists localized anatomic structures for accuracy assessment. Algorithm accuracy was determined by comparing the computer-predicted displacement at each bifurcation point with the displacement computed from the oncologists' annotations. Thirty-seven academic institutions and medical device manufacturers with published evidence of active deformable image registration capabilities were invited to participate. Results: Twenty-seven groups agreed to participate; 6 did not return results. Sixteen completed the liver 4D-CT, 12 the lung 4D-CT, 3 the prostate MRI, and 3 the liver MRI-CT. The range of average absolute error for the lung 4D-CT was 0.6-1.2 mm (left-right [LR]), 0.5-1.8 mm (anterior-posterior [AP]), and 0.7-2.0 mm (superior-inferior [SI]); the liver 4D-CT was 0.8-1.5 mm (LR), 1.0-5.2 mm (AP), and 1.0-5.9 mm (SI); the liver MRI-CT was 1.1-2.6 mm (LR), 2.0-5.0 mm (AP), and 2.2-2.6 mm (SI); and the repeat prostate MRI prostate datasets was 0.5-6.2 mm (LR), 3.1-3.7 mm (AP), and 0.4-2.0 mm (SI). Conclusions: An infrastructure was developed to assess multi-institution deformable registration accuracy. The results indicate large discrepancies in reported shifts, although the majority of deformable registration algorithms performed at an accuracy equivalent to the voxel size, promising to improve treatment planning, delivery, and assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfraction and Intrafraction Changes in Amplitude of Breathing Motion in Stereotactic Liver Radiotherapy

Purpose: Interfraction and intrafraction changes in amplitude of liver motion were assessed in patients with liver cancer treated with kV cone beam computed tomography (CBCT)-guided stereotactic body radiation therapy (SBRT). Methods and Materials: A total of 314 CBCTs obtained with the patient in the treatment position immediately before and after each fraction, and 29 planning 4DCTs were evaluated in 29 patients undergoing six-fraction SBRT for unresectable liver cancer, with (n = 15) and without (n = 14) abdominal compression. Offline, the CBCTs were sorted into 10 bins, based on phase of respiration. Liver motion amplitude was measured using liver-to-liver alignment from the end-exhale and end-inhale CBCT and four-dimensional CT reconstructions. Inter- and intrafraction amplitude changes were measured from the difference between the pre-SBRT CBCTs relative to the planning four-dimensional CT, and from the pre-SBRT and post-SBRT CBCTs, respectively. Results: Mean liver motion amplitude for all patients (range) was 1.8 (0.1-7.0), 8.0 (0.1-18.8), and 4.3 (0.1-12.1) mm in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) directions, respectively. Mean absolute inter- and intrafraction liver motion amplitude changes were 1.0 (ML), 1.7 (CC), and 1.6 (AP) mm and 1.3 (ML), 1.6 (CC), and 1.9 (AP) mm, respectively. No significant correlations were found between intrafraction amplitude change and intrafraction time (range, 4:56-25:37min:sec), and between inter- and intrafraction amplitude changes and liver motion amplitude. Intraobserver reproducibility ({sigma}, n = 29 fractions) was 1.3 (ML), 1.4 (CC), and 1.4 (AP) mm. Conclusions: For the majority of liver SBRT patients, the change in liver motion amplitude was minimal over the treatment course and showed no apparent relationships with the magnitude of liver motion and intrafraction time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Lung Treatment Planning in Layer-Stacking Carbon Ion Beam Treatment: Comparison of Layer-Stacking and Conventional Ungated/Gated Irradiation

Purpose: We compared four-dimensional (4D) layer-stacking and conventional carbon ion beam distribution in the treatment of lung cancer between ungated and gated respiratory strategies using 4DCT data sets. Methods and Materials: Twenty lung patients underwent 4DCT imaging under free-breathing conditions. Using planning target volumes (PTVs) at respective respiratory phases, two types of compensating bolus were designed, a full single respiratory cycle for the ungated strategy and an approximately 30% duty cycle for the exhalation-gated strategy. Beams were delivered to the PTVs for the ungated and gated strategies, PTV(ungated) and PTV(gated), respectively, which were calculated by combining the respective PTV(Tn)s by layer-stacking and conventional irradiation. Carbon ion beam dose distribution was calculated as a function of respiratory phase by applying a compensating bolus to 4DCT. Accumulated dose distributions were calculated by applying deformable registration. Results: With the ungated strategy, accumulated dose distributions were satisfactorily provided to the PTV, with D95 values for layer-stacking and conventional irradiation of 94.0% and 96.2%, respectively. V20 for the lung and Dmax for the spinal cord were lower with layer-stacking than with conventional irradiation, whereas Dmax for the skin (14.1 GyE) was significantly lower (21.9 GyE). In addition, dose conformation to the GTV/PTV with layer-stacking irradiation was better with the gated than with the ungated strategy. Conclusions: Gated layer-stacking irradiation allows the delivery of a carbon ion beam to a moving target without significant degradation of dose conformity or the development of hot spots.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance of 4D-CT Scan Techniques in Multicenter Phase III Trial of Surgery Versus Stereotactic Radiotherapy (Radiosurgery or Surgery for Operable Early Stage (Stage 1A) Non-Small-Cell Lung Cancer [ROSEL] Study)

Purpose: To determine the accuracy of four-dimensional computed tomography (4D-CT) scanning techniques in institutions participating in a Phase III trial of surgery vs. stereotactic radiotherapy (SBRT) for lung cancer. Methods and Materials: All 9 centers performed a 4D-CT scan of a motion phantom (Quasar, Modus Medical Devices) in accordance with their in-house imaging protocol for SBRT. A cylindrical cedar wood insert with plastic spheres of 15 mm (o15) and 30 mm (o30) diameter was moved in a cosine-based pattern, with an extended period in the exhale position to mimic the actual breathing motion. A range of motion of R = 15 and R = 25 mm and breathing period of T = 3 and T = 6 s were used. Positional and volumetric imaging accuracy was analyzed using Pinnacle version 8.1x at various breathing phases, including the mid-ventilation phase and maximal intensity projections of the spheres. Results: Imaging using eight CT scanners (Philips, Siemens, GE) and one positron emission tomography-CT scanner (Institution 3, Siemens) was investigated. The imaging protocols varied widely among the institutions. No strong correlation was found between the specific scan protocol parameters and the observed results. Deviations in the maximal intensity projection volumes averaged 1.9% (starting phase of the breathing cycle [o]15, R = 15), 12.3% (o15, R = 25), and -0.9% (o30, R = 15). The end-expiration volume deviations (13.4%, o15 and 2.5%, o30), were, on average, smaller than the end-inspiration deviations (20.7%, o15 and 4.5%, o30), which, in turn, were smaller than the mid-ventilation deviations (32.6%, o15 and 8.0%, o30). A slightly larger variation in the mid-ventilation origin position was observed (mean, -0.2 mm; range, -3.6-4.2) than in the maximal intensity projection origin position (mean, -0.1 mm; range, -2.5-2.5). The range of motion was generally underestimated (mean, -1.5 mm; range, -5.5-1). Conclusions: Notable differences were seen in the 4D-CT imaging protocols for SBRT among centers. However, the observed deviations in target volumes were generally small. They were slightly larger for the mid-ventilation phases and smallest for the end-expiration phases. Steps to optimize and standardize the 4D-CT scanning protocols for SBRT are desirable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Positron Emission Tomography: Implications for Dose Painting of High-Uptake Regions

Purpose: To investigate the behavior of tumor subvolumes of high [18F]-fluorodeoxyglucose (FDG) uptake as seen on clinical four-dimensional (4D) FDG-positron emission tomography (PET) scans. Methods and Materials: Four-dimensional FDG-PET/computed tomography scans from 13 patients taken before radiotherapy were available. The analysis was focused on regions of high uptake that are potential dose-painting targets. A total of 17 lesions (primary tumors and lymph nodes) were analyzed. On each one of the five phases of the 4D scan a classification algorithm was applied to obtain the region of highest uptake and segment the tumor volume. We looked at the behavior of both the high-uptake subvolume, called 'Boost,' and the segmented tumor volume, called 'Target.' We measured several quantities that characterize the Target and Boost volumes and quantified correlations between them. Results: The behavior of the Target could not always predict the behavior of the Boost. The shape deformation of the Boost regions was on average 133% higher than that of the Target. The gross to internal target volume expansion was on average 27.4% for the Target and 64% for the Boost, a statistically significant difference (p < 0.05). Finally, the inhale-to-exhale phase (20%) had the highest shape deformation for the Boost regions. Conclusions: A complex relationship between the measured quantities for the Boost and Target volumes is revealed. The results suggest that in cases in which advanced therapy techniques such as dose painting are being used, a close examination of the 4D PET scan should be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Four-Dimensional Computed Tomography Analysis of Multiorgan Abdominal Motion

Purpose: To characterize and quantify multiorgan respiration-induced motion in the abdomen in liver and pancreatic cancer patients. Methods and Materials: Four-dimensional computed tomography scans were acquired for 18 patients treated for abdominal tumors. Contours of multiple abdominal organs were drawn by the radiation oncologist at one respiratory phase; these contours were propagated to other respiratory phases by deformable registration. Three-dimensional organ models were generated from the resulting contours at each phase. Motions of the bounding box and center of mass were extracted and analyzed for the clinical target volume and organs at risk. Results: On average, the center of mass motion for liver clinical target volumes was 9.7 mm (SD 5 mm) in the superior-inferior direction, with a range of 3 to 18 mm; for pancreatic tumors, the average was 5 mm (SD 1 mm) m with a range of 3 to 7 mm. Abdominal organs move in unison, but with varying amplitudes. Gating near exhale (T40-T60) reduces the range of motion by a factor of {approx}10. Conclusion: We have used deformable registration to calculate the trajectories of abdominal organs in four dimensions, based on center of mass and bounding box motion metrics. Our results are compared with previously reported studies. Possible reasons for differences are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of the Variability of Diaphragm Motion and Implications for Treatment Margin Construction

Purpose: To quantify the variability of diaphragm motion during free-breathing radiotherapy of lung patients and its effect on treatment margins to account for geometric uncertainties. Methods and Materials: Thirty-three lung cancer patients were analyzed. Each patient had 5-19 cone-beam scans acquired during different treatment fractions. The craniocaudal position of the diaphragm dome on the same side as the tumor was tracked over 2 min in the projection images, because it is both easily visible and a suitable surrogate to study the variability of the tumor motion and its impact on treatment margins. Intra-acquisition, inter-acquisition, and inter-patient variability of the respiratory cycles were quantified separately, as were the probability density functions (PDFs) of the diaphragm position over each cycle, each acquisition, and each patient. Asymmetric margins were simulated using each patient PDF and compared to symmetric margins computed from a margin recipe. Results: The peak-to-peak amplitude variability (1 SD) was 3.3 mm, 2.4 mm, and 6.1 mm for the intra-acquisition, inter-acquisition, and inter-patient variability, respectively. The average PDF of each cycle was similar to the sin{sup 4} function but the PDF of each acquisition was closer to a skew-normal distribution because of the motion variability. Despite large interfraction baseline variability, the PDF of each patient was generally asymmetric with a longer end-inhale tail because the end-exhale position was more stable than the end-inhale position. The asymmetry of the PDF required asymmetric margins around the time-averaged position to account for the position uncertainty but the average difference was 1.0 mm (range, 0.0-4.4 mm) for a sharp penumbra and an idealized online setup correction protocol. Conclusion: The respiratory motion is more irregular during the fractions than between the fractions. The PDF of the respiratory motion is asymmetrically distributed. Both the intra-acquisition variability and the PDF asymmetry have a limited impact on dose distributions and inferred margins. The use of a margin recipe to account for respiratory motion with an estimate of the average motion amplitude was adequate in almost all patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accumulated Dose in Liver Stereotactic Body Radiotherapy: Positioning, Breathing, and Deformation Effects

Purpose: To investigate the accumulated dose deviations to tumors and normal tissues in liver stereotactic body radiotherapy (SBRT) and investigate their geometric causes. Methods and Materials: Thirty previously treated liver cancer patients were retrospectively evaluated. Stereotactic body radiotherapy was planned on the static exhale CT for 27-60 Gy in 6 fractions, and patients were treated in free-breathing with daily cone-beam CT guidance. Biomechanical model-based deformable image registration accumulated dose over both the planning four-dimensional (4D) CT (predicted breathing dose) and also over each fraction's respiratory-correlated cone-beam CT (accumulated treatment dose). The contribution of different geometric errors to changes between the accumulated and predicted breathing dose were quantified. Results: Twenty-one patients (70%) had accumulated dose deviations relative to the planned static prescription dose >5%, ranging from -15% to 5% in tumors and -42% to 8% in normal tissues. Sixteen patients (53%) still had deviations relative to the 4D CT-predicted dose, which were similar in magnitude. Thirty-two tissues in these 16 patients had deviations >5% relative to the 4D CT-predicted dose, and residual setup errors (n = 17) were most often the largest cause of the deviations, followed by deformations (n = 8) and breathing variations (n = 7). Conclusion: The majority of patients had accumulated dose deviations >5% relative to the static plan. Significant deviations relative to the predicted breathing dose still occurred in more than half the patients, commonly owing to residual setup errors. Accumulated SBRT dose may be warranted to pursue further dose escalation, adaptive SBRT, and aid in correlation with clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Management of Respiration-Induced Motion With 4-Dimensional Computed Tomography (4DCT) for Pancreas Irradiation

Purpose: The purposes of this study were to quantify respiration-induced organ motions for pancreatic cancer patients and to explore strategies to account for these motions. Methods and Materials: Both 3-dimensional computed tomography (3DCT) and 4-dimensional computed tomography (4DCT) scans were acquired sequentially for 15 pancreatic cancer patients, including 10 randomly selected patients and 5 patients selected from a subgroup of patients with large tumor respiratory motions. 3DCTs were fused with 2 sets of 4DCT data at the end of exhale phase (50%) and the end of inhale phase (0%). The target was delineated on the 50% and 0% phase CT sets, and the organs at risk were drawn on the 3DCT. These contours were populated to the CT sets at other respiratory phases based on deformable image registration. Internal target volumes (ITV) were generated by tracing the target contours of all phases (ITV{sub 10}), 3 phases of 0%, 20% and 50% (ITV{sub 3}), and 2 phases of 0% and 50% (ITV{sub 2}). ITVs generated from phase images were compared using percentage of volume overlap, Dice coefficient, geometric centers, and average surface distance. Results: Volume variations of pancreas, kidneys, and liver as a function of respiratory phases were small (<5%) during respiration. For the 10 randomly selected patients, peak-to-peak amplitudes of liver, left kidney, right kidney, and the target along the superior-inferior (SI) direction were 7.9 ± 3.2 mm, 7.1 ± 3.1 mm, 5.7 ± 3.2 mm, and 5.9 ± 2.8 mm, respectively. The percentage of volume overlap and Dice coefficient were 92% ± 1% and 96% ± 1% between ITV{sub 10} and ITV{sub 2} and 96% ± 1% and 98% ± 1% between ITV{sub 10} and ITV{sub 3}, respectively. The percentage of volume overlap between ITV{sub 10} and ITV{sub 3} was 93.6 ± 1.1 for patients with tumor motion >8 mm. Conclusions: Appropriate motion management strategies are proposed for radiation treatment planning of pancreatic tumors based on magnitudes of tumor respiratory motions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Amplitude-Based and Phase-Based Positron Emission Tomography Gating Algorithms for Segmentation of Internal Target Volumes of Tumors Subject to Respiratory Motion

Purpose: To quantitatively compare the accuracy of tumor volume segmentation in amplitude-based and phase-based respiratory gating algorithms in respiratory-correlated positron emission tomography (PET). Methods and Materials: List-mode fluorodeoxyglucose-PET data was acquired for 10 patients with a total of 12 fluorodeoxyglucose-avid tumors and 9 lymph nodes. Additionally, a phantom experiment was performed in which 4 plastic butyrate spheres with inner diameters ranging from 1 to 4 cm were imaged as they underwent 1-dimensional motion based on 2 measured patient breathing trajectories. PET list-mode data were gated into 8 bins using 2 amplitude-based (equal amplitude bins [A1] and equal counts per bin [A2]) and 2 temporal phase-based gating algorithms. Gated images were segmented using a commercially available gradient-based technique and a fixed 40% threshold of maximum uptake. Internal target volumes (ITVs) were generated by taking the union of all 8 contours per gated image. Segmented phantom ITVs were compared with their respective ground-truth ITVs, defined as the volume subtended by the tumor model positions covering 99% of breathing amplitude. Superior-inferior distances between sphere centroids in the end-inhale and end-exhale phases were also calculated. Results: Tumor ITVs from amplitude-based methods were significantly larger than those from temporal-based techniques (P=.002). For lymph nodes, A2 resulted in ITVs that were significantly larger than either of the temporal-based techniques (P<.0323). A1 produced the largest and most accurate ITVs for spheres with diameters of ≥2 cm (P=.002). No significant difference was shown between algorithms in the 1-cm sphere data set. For phantom spheres, amplitude-based methods recovered an average of 9.5% more motion displacement than temporal-based methods under regular breathing conditions and an average of 45.7% more in the presence of baseline drift (P<.001). Conclusions: Target volumes in images generated from amplitude-based gating are larger and more accurate, at levels that are potentially clinically significant, compared with those from temporal phase-based gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafraction Variability and Deformation Quantification in the Breast

Purpose: To evaluate intrafraction variability and deformation of the lumpectomy cavity (LC), breast, and nearby organs. Methods and Materials: Sixteen left-sided postlumpectomy and 1 bilateral breast cancer cases underwent free-breathing CT (FBCT) and 10-phase 4-dimensional CT (4DCT). Deformable image registration was used for deformation analysis and contour propagation of breast, heart, lungs, and LC between end-exhale and end-inhale 4DCT phases. Respiration-induced motion was calculated via centroid analysis. Two planning target volumes (PTVs) were compared: PTV{sub FBCT} from the FBCT volume with an isotropic 10 mm expansion (5 mm excursion and 5 mm setup error) and PTV{sub 4DCT} generated from the union of 4DCT contours with isotropic 5 mm margin for setup error. Volume and geometry were evaluated via percent difference and bounding box analysis, respectively. Deformation correlations between breast/cavity, breast/lung, and breast/heart were evaluated. Associations were tested between cavity deformation and proximity to chest wall and breast surface. Results: Population-based 3-dimensional vector excursions were 2.5 ± 1.0 mm (range, 0.8-3.8 mm) for the cavity and 2.0 ± 0.8 mm (range, 0.7-3.0 mm) for the ipsilateral breast. Cavity excursion was predominantly in the anterior and superior directions (1.0 ± 0.8 mm and −1.8 ± 1.2 mm, respectively). Similarly, for all cases, LCs and ipsilateral breasts yielded median deformation values in the superior direction. For 14 of 17 patients, the LCs and breast interquartile ranges tended toward the anterior direction. The PTV{sub FBCT} was 51.5% ± 10.8% larger (P<.01) than PTV{sub 4DCT}. Bounding box analysis revealed that PTV{sub FBCT} was 9.8 ± 1.2 (lateral), 9.0 ± 2.2 (anterior–posterior), and 3.9 ± 1.8 (superior–inferior) mm larger than PTV{sub 4DCT}. Significant associations between breast and cavity deformation were found for 6 of 9 axes. No dependency was found between cavity deformation and proximity to chest wall or breast surface. Conclusions: Lumpectomy cavity and breast deformation and motion demonstrated large variability. A PTV{sub 4DCT} approach showed value in patient-specific margins, particularly if robust interfraction setup analysis can be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗