Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPLODING WIRES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Operability thresholds for thermally damaged EBW detonators

Operability thresholds that differentiate between functional RP-87 exploding bridge wire (EBW) detonators and nonfunctional RP-87 EBW detonators (duds) were determined by measuring the time delay between initiation and early wall movement (function time). The detonators were inserted into an externally heated hollow cylinder of aluminum and fired with current flow from a charged capacitor using an exploding bridge wire (EBW initiated). Functioning detonators responded like unheated pristine detonators when the function time was 4 μs or less. The operability thresholds of the detonators were characterized with a simple decomposition cookoff model calibrated using a modified version of the Sandia Instrumented Thermal Ignition (SITI) experiment. These thresholds are based on the calculated state of the PETN when the detonators fire. The operability threshold is proportional to the positive temperature difference (ΔT) between the maximum temperature within the PETN and the onset of decomposition (~406 K). Furthermore, the temperature difference alone was not sufficient to define the operability threshold. The operability threshold was also proportional to the time that the PETN had been at elevated temperatures. That is, failure was proportional to both temperature and reaction rate. The reacted gas fraction is used in the current work for the reaction correlation. Melting of PETN also had a significant effect on the operability threshold. Detonator failure occurred when the maximum temperature exceeded the nominal melting point of PETN (414 K) for 45±5 s or more.

42 ENGINEERING↗

Investigation of Parameters on Thermally Cycled EBW Detonators

Working towards an optimal exploding bridge wire (EBW) detonator design, three parameters were varied among two detonator platforms. These three parameters were bridge wire diameter, high explosive (HE) density, and sleeve material. These parameters were chosen due to their potential to benefit initiation characteristics. The performance of each parameter was characterized at pristine conditions and after thermal cycling and firing cold. The overall performance as well as the severity of performance loss observed after thermal conditioning were considered. The results of this parameter study are presented and trends related to parameter variation are examined.

42 ENGINEERING↗

Spectroscopy of a plasma formed in the vicinity of implosion of the shock wave generated by underwater electrical explosion of spherical wire array

The results of visible spectroscopy of the plasma formed inside a copper capillary placed at the equatorial plane of an underwater electrically exploded spherical wire array (30 mm in diameter; 40 wires, each of 100 μm in diameter) are reported. In the experiments, a pulsed power generator with current amplitude of ∼300 kA and rise time of ∼1.1 μs was used to produce wire array explosion accompanied by the formation of a converging strong shock wave. The data obtained support the assumption of uniformity of the shock wave along the main path of its convergence. The spectroscopic measurements show that this rather simple method of formation of a converging strong shock wave can be used successfully for studying the shock wave's interaction with matter and the evaporation processes of atoms from a target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation on the energy deposition and morphology of the electrical explosion of copper wire in vacuum

This paper presents the experimental results of the electrical explosion of copper wires in vacuum using negative nanosecond-pulsed current with magnitude of 1–2 kA. The 20 μm-diameter copper wires with different lengths are exploded with three different current rates. A laser probe is applied to construct the shadowgraphy and interferometry diagnostics to investigate the distribution and morphology of the exploding product. The interference phase shift is reconstructed from the interferogram, by which the atomic density distribution is calculated. Experimental results show that there exist two voltage breakdown modes depending on the amount of the specific energy deposition. For the strong-shunting mode, shunting breakdown occurs, leading to the short-circuit-like current waveform. For the weak-shunting mode with less specific energy deposition, the plasma generated during the voltage breakdown is not enough to form a conductive plasma channel, resulting in overdamped declining current waveform. The influence of the wire length and current rate on the characteristics of the exploding wires is also analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transforming dielectric coated tungsten and platinum wires to gaseous state using negative nanosecond-pulsed-current in vacuum

With the help of thin dielectric coatings, corona free explosions were achieved in the region of about half a wire length (2 cm) for tungsten wires and nearly the whole wire length for platinum wires under a fast rising (46–170 A/ns) negative polarity current in vacuum. Expansion velocity of the tungsten gas was over 10 km/s. Current waveforms from exploding coated wires were similar to those from bare wires in the air including a current pause stage. Coated wires with different coating parameters had a similar joule energy deposition before voltage collapsed, but a quite different scenario in the region near the electrodes. The axial field under negative current was the main reason for the axial inhomogeneity of coated tungsten wires. Tungsten or platinum gases in the vaporized region were tightly encompassed by the dielectric coating, while gaps or probably low density gases, were observed between the coating and the edge of the dense wire core in the core-corona structure region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current shunting and formation of stationary shock waves during electric explosions of metal wires in air

Results of experiments on the generation of shock waves during electric explosions of fine copper and tungsten wires in air are analyzed. The generation mechanism of stationary shock wave by a plasma piston formed during the shunting breakdown of the electrode gap in the course of a wire explosion is investigated. The role of structural elements of such discharges, such as the core, corona, and wire environment, is analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical investigation on the implosion dynamics of wire-array Z-pinches in (r, {theta}) geometry

The implosion dynamics of wire-array Z-pinches are investigated numerically in 2D (r, {theta}) geometry by using a resistive MHD code. It is assumed that the wires have expanded to plasmas with diameter d{sub 0}, which is used as the initial condition for the consequent implosion process. In fact, the explosion process of individual wires is not included. By changing d{sub 0}, the effects of the wire expansion degree on the implosion dynamics are analyzed. When d{sub 0} is larger, the current density is more concentrated at the outer side of the wires and the fraction of current flow around the wire plasmas is nearly in proportion to d{sub 0}. As a result, the ablation rate of wires is increased and the implosion phase starts earlier. This conclusion agrees with the simulation works of other authors [Chittenden et al., Phys. Plasmas 11(3), 1118 (2004)]. When the array radius and initial wire plasma diameter are fixed, the increase of wire number leads to the azimuthal merge of wires during implosion. When the wires number exceed a critical value, which is related to d{sub 0}, wire plasmas can merge to a continuous shell with an azimuthal perturbation in density, which depends on the initial wires number.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of soft metal gasket contacts on contact resistance, energy deposition, and plasma expansion profile in a wire array Z pinch

Soft metal gaskets (indium and silver) were used to reduce contact resistance between the wire and the electrode in an aluminum wire Z pinch by more than an order of magnitude over the best weighted contact case. Clamping a gasket over a Z-pinch wire compresses the wire to the electrode with a greater normal force than possible with wire weights. Average contact resistance was reduced from the range of 100-3000 {omega} (depending on wire weight mass) to 1-10 {omega} with soft metal gaskets. Single wire experiments (13 {mu}m Al 5056) on a 16 kA, 100 kV Marx bank showed an increase in light emission (97%) and emission volume (100%) of the plasma for the reduced contact resistance cases. The measured increases in plasma volume and light emission indicate greater energy deposition in the ablated wire. Additionally, dual-wire experiments showed plasma edge effects were significantly decreased in the soft metal gasket contact case. The average height of the edge effects was reduced by 51% and the width of the edge effects was increased by 40%, thus the gasket contact case provided greater axial uniformity in the plasma expansion profile of an individual wire.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the core gaps formed accidentally during wire explosion

During wire explosion, along with striations (a regular structure with alternating lower and higher density bands), low-density regions the characteristic axial size of which differs substantially from that of striations and can reach 1-2 mm are also observed in the discharge channel. Such irregular structures came to be known as 'gaps' (D. B. Sinars et al., Phys. Plasmas 8, 216 (2001)). In the present study, the mechanism of the formation of core gaps during explosions of 25- and 50-{mu}m-diameter copper and nickel wires in air is investigated. It is shown that the specific energy deposited in the gap region substantially exceeds the average specific energy deposited in the wire material.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initiation of aluminum wire array on the 1-MA ZEBRA accelerator and its effect on ablation dynamics and x-ray yield

The effect of current prepulse on the initiation of Al wire arrays, ablation dynamics and x-ray production was investigated on the 1-MA ZEBRA accelerator (University of Nevada, Reno). It is shown that increasing the number of wires lowers the temperature of the wire cores at the time of breakdown. Al arrays with cold wire cores demonstrate long and inhomogeneous ablation, and a less intense, wider x-ray pulse. Shortening the current prepulse by a flashover switch causes an increased wire-core temperature, symmetrization and synchronization of the wires' ablation, and improvement of the amplitude and shape of the x-ray pulse. Application of a vacuum flashover switch can be important for shortening the current prepulse on the upcoming 28-MA ZR-accelerator at Sandia National Laboratories to optimize the x-ray production and shot-to-shot reproducibility from wire-array Z pinches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Growth and saturation of the axial instability in low wire number wire array Z pinches

The growth of the axial instability in low wire number wire array Z pinches using a 100 ns rise time, 1 MA pulsed power accelerator is examined. The axial instability manifests itself as a quasiperiodic variation of the radius of the coronal plasma along each wire and a consequent modulation of the rate of ablation of material from the dense wire core. The dominant wavelength of the modulation becomes constant late in time. In this work laser shadowgraphy is used to measure the growth of the wavelength and amplitude of the instability as well as the size of the coronal plasma in aluminum wire arrays from the time of plasma formation to the time the wavelength seen late in time is reached. Using magnetic probes, the distribution of current and magnetic topology are also investigated. It is found that a distinct change in magnetic field topology associated with the onset of advection of current to the array axis by the streaming wire-ablation plasma appears to be responsible for ending the growth of the axial instability and initiating the quasisteady state ablation phase of the wire array Z pinch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the precursor and non-precursor implosion regimes in wire array Z-pinches

Star-like and closely spaced nested wire array configurations were investigated in precursor and non-precursor implosions. Closely spaced nested cylindrical arrays have inner and outer arrays with equal wire numbers, and inner and outer wires aligned to each other. The gap between the outer and inner wires is not more than 1 mm. Calculation of magnetic fields shows that the small gap results in a reversed, outward j Multiplication-Sign B force on the inner wires. Closely spaced arrays of 6-16 wires with outer diameter of 16 mm and with gaps of {Delta}R = 0.25-1 mm were tested. 6-8-wire arrays with a gap of {Delta}R = 0.4-1 mm imploded without precursor, but precursor was present in loads with 12-16 wires and {Delta}R = 0.25-1 mm. Implosion dynamics of closely spaced arrays was similar to that of star-like arrays. Implosion time was found to decrease with decreased wire numbers. Star array configurations were designed with a numerical scheme to implode with or without precursor. The lack of precursor resulted in a marginal improvement in total x-ray yield and power, and up to 20% increase in Al K-shell yield. The Al K-shell radiated energy was found to increase with decreasing the number of arrays in closely spaced and star-like wire arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axial x-ray backlighting of wire-array Z-pinches using X pinches

For the first time, a geometry has been developed to allow for an axial imaging system for wire-array Z-pinch experiments that produce high-resolution x-ray images. The new geometry required a significant redesign of the electrode hardware. Calibrated areal density measurements of the Z-pinch plasma including wire cores, coronal plasma, streaming plasma, and the precursor were obtained. The system used eight-wire molybdenum (Mo) X pinches in series with and directly below the Z-pinch axis to provide micron-scale x-rays sources for point-projection radiography. The images formed on the x-ray sensitive film had a 15 mm diameter field of view at the center height of the array and a magnification of about 7.5:1. Titanium (Ti) filters in front of the film transmitted radiation in the spectral range of 3-5 keV. For calibration, a separate film with the same thickness Ti filter was placed the same distance from the X pinch. This film had an unobstructed path that bypasses the Z-pinch but included step wedges for calibration of the Z-pinch plasma. The step wedges had thicknesses of tungsten (W) ranging from 0.015 to 1.1 {mu}m to obtain areal density measurements of the W plasma from the wire-array. Images had subnanosecond temporal resolution and about 10 {mu}m spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Pinch And Its Applications In X-ray Radiograph

An X-pinch device and the related diagnostics of x-ray emission from X-pinch were briefly described. The time-resolved x-ray measurements with photoconducting diodes show that the x-ray pulse usually consists of two subnanosecond peaks with a time interval of about 0.5 ns. Being consistent with these two peaks of the x-ray pulse, two point x-ray sources of size ranging from 100 mum to 5 mum and depending on cut-off x-ray photon energy were usually observed on the pinhole pictures. The x-pinch was used as x-ray source for backlighting of the electrical explosion of single wire and the evolution of X-pinch, and for phase-contrast imaging of soft biological objects such as a small shrimp and a mosquito.

07 ISOTOPE AND RADIATION SOURCES↗

Azimuthally correlated ablation between z-pinch wire cores

Azimuthally correlated wire core ablation was compared for closely spaced versus widely spaced wires in a 1 MA Z-pinch. X-ray point-projection diagnostics revealed that 240 {mu}m spaced wires exhibited a correlation coefficient approaching unity in both real space and in k-space. This correlated ablation between wires at a fixed axial location is believed to occur due to an enhanced, localized Joule heating. Wires separated by 2.47 mm or greater were uncorrelated in real space, but correlated in k-space, indicating the ablation structure between wires was shifted in phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical studies of the effects of precursor plasma on the performance of wire-array Z-pinches

This paper is to numerically investigate, in one dimension, the effects of precursor plasma resulted from wire-array ablation on the performance of its following implosion after the ablation. The wire-array ablation is described by an analytic model, which consists of a rocket model or Sasorov's expression of wire-array mass ablation rate, the evolution equation of magnetic field, and several roughly reasonable assumptions. The following implosion is governed by the radiation magnetohydrodynamics. The implosion processes of wire-array Z-pinch from plasma shells prefilled and un-prefilled by the low-density plasma inside them are studied, and that from the wire-array ablations, which may be changed through varying the ablation time, ablation rate, and ablation velocity V{sub abl}, are also simulated. The obtained results reveal that the prefilled low-density plasma and the precursor plasma from the wire-array ablation help to enhance the plasma shell pinch and the final implosion of the wire array, respectively, compared to the pinch of un-prefilled plasma shell. With the same plasma masses, which are distributed in the interior of the array and the shell, and modified Spitzer resistivity, the implosions that start from the wire ablation develop faster than that from the plasma shell with the prefill. If more substance ablates from the wire array before the start of its implosion, the final Z-pinch performance could be better. The Z-pinch plasma is highly magnetized with driven current more than 3 MA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron emission generated during wire array Z-pinch implosion onto deuterated fiber

The implosion of both cylindrical and conical wire arrays onto a deuterated polyethylene fiber was studied on the S-300 pulsed power generator [A. S. Chernenko et al., Proceedings of the 11th International Conference on High Power Particle Beams (Academy of Science of Czech Republic, Prague, 1996), p. 154]. Neutron measurements were used to obtain information about acceleration of fast deuterons. An average neutron yield approached 10{sup 9} on the current level of 2 MA. In the case of conical wire arrays, side-on neutron energy spectra peaked at 2.48{+-}0.05 MeV with 450{+-}100 keV full width at half-maximum. In the downstream direction, the peak neutron energy and the width of a neutron spectrum were 2.65{+-}0.10 MeV and 350{+-}100 keV, respectively. The total number of fast deuterons was 10{sup 15} and their average kinetic energy was about 150 keV. Most of the deuterons were directed toward the cathode. The broad width of neutron spectra in the side-on direction implied a high radial component of deuteron velocity. With regard to the emission time, neutron pulses temporally correlated with hard x rays and also with measured voltage. The neutron emission lasted on average 30{+-}5 ns and it was observed during the stagnation and at the beginning of the expansion of a plasma column. At this moment, the plasma impedance reached 0.2-0.4 {omega}. In the post-stagnation phase, this value was formed significantly by enhanced plasma resistance. Similar experimental results were observed also with cylindrical wire arrays imploding onto a deuterated fiber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Peculiarities of planar shockwave interaction with air–water interface and solid target

We present the results of the research on underwater electrical explosion of planar copper wire arrays, accompanied by the generation of a planar shock, using the synchrotron-based phase-contrast radiography imaging capabilities of the ID19 beamline at the European Synchrotron Radiation Facility. It is shown that the interaction of a strong shock with an air–water interface leads to additional acceleration of the wire expansion due to a rarefaction wave along with the emergence of micro-jets. In the case of a target placed above the array, we observed the formation of a cavity between the array and the target due to the interaction of two rarefaction waves. Furthermore, the results of two-dimensional hydrodynamic simulations of the wire explosion and the interaction of the generated shock with the water–air and water-target interfaces showed good agreement with experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗