Search NASA⌕ Search

SEARCH · Search NASA

Results for “EYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Control of laser-beam spatial distribution for correcting the shape and refraction of eye cornea

The results of calculation and development of a device aimed at forming a laser beam with an annular intensity distribution and spatial mode homogenisation, as well as approbation of this device for biological phantoms and eyes in ex vivo experiments with laser non-ablative correction of the cornea profile, are presented. The radiation intensities and thermal field distributions on the surfaces of a phantom and isolated rabbit’s eye are investigated. The absence of significant heating in the central region of eye is confirmed. It is shown that this device can be used for laser impact in order to change symmetrically eye’s refraction. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray study of the double source plane gravitational lens system Eye of Horus observed with XMM–Newton

ABSTRACT A double source plane (DSP) system is a precious probe for the density profile of distant galaxies and cosmological parameters. However, these measurements could be affected by the surrounding environment of the lens galaxy. Thus, it is important to evaluate the cluster-scale mass for detailed mass modelling. We observed the Eye of Horus, a DSP system discovered by the Hyper Suprime-Cam Subaru Strategic Survey (HSC–SSP), with XMM–Newton. We detected two X-ray extended emissions, originating from two clusters, one centred at the Eye of Horus, and the other located ∼100 arcsec north-east to the Eye of Horus. We determined the dynamical mass assuming hydrostatic equilibrium, and evaluated their contributions to the lens mass interior of the Einstein radius. The contribution of the former cluster is $1.1^{+1.2}_{-0.5}\times 10^{12}\, \mathrm{M}_{\odot }$, which is $21\!-\!76{{\ \rm per\ cent}}$ of the total mass within the Einstein radius. The discrepancy is likely due to the complex gravitational structure along the line of sight. On the other hand, the contribution of the latter cluster is only $\sim 2{{\ \rm per\ cent}}$ on the Eye of Horus. Therefore, the influence associated with this cluster can be ignored.

Tanaka, Keigo↗

A new fixation aid for the radiotherapy of eye tumors

A modified swim goggle holding a light spot as an optical guide for actively aligning the eye in a reproducible orientation has been constructed to perform radiotherapy of ocular tumors. This device is compatible with computed tomography (CT) and magnetic resonance imaging systems. Image fusion of these data sets yielded clinically acceptable results. The reproducibility of the eye's positioning is tested by repeated CT. The eye's alignment during radiotherapy is monitored by an infrared TV camera with individual markings of the eye's position on the TV-monitor screen. From 2003-2006, 50 patients were treated with this fixation aid by radiosurgery with good patient compliance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

BEDVH--A method for evaluating biologically effective dose volume histograms: Application to eye plaque brachytherapy implants

Purpose: A method is introduced to examine the influence of implant duration T, radionuclide, and radiobiological parameters on the biologically effective dose (BED) throughout the entire volume of regions of interest for episcleral brachytherapy using available radionuclides. This method is employed to evaluate a particular eye plaque brachytherapy implant in a radiobiological context. Methods: A reference eye geometry and 16 mm COMS eye plaque loaded with {sup 103}Pd, {sup 125}I, or {sup 131}Cs sources were examined with dose distributions accounting for plaque heterogeneities. For a standardized 7 day implant, doses to 90% of the tumor volume ( {sub TUMOR}D{sub 90}) and 10% of the organ at risk volumes ( {sub OAR}D{sub 10}) were calculated. The BED equation from Dale and Jones and published {alpha}/{beta} and {mu} parameters were incorporated with dose volume histograms (DVHs) for various T values such as T = 7 days (i.e., {sub TUMOR} {sup 7}BED{sub 10} and {sub OAR} {sup 7}BED{sub 10}). By calculating BED throughout the volumes, biologically effective dose volume histograms (BEDVHs) were developed for tumor and OARs. Influence of T, radionuclide choice, and radiobiological parameters on {sub TUMOR}BEDVH and {sub OAR}BEDVH were examined. The nominal dose was scaled for shorter implants to achieve biological equivalence. Results: {sub TUMOR}D{sub 90} values were 102, 112, and 110 Gy for {sup 103}Pd, {sup 125}I, and {sup 131}Cs, respectively. Corresponding {sub TUMOR} {sup 7}BED{sub 10} values were 124, 140, and 138 Gy, respectively. As T decreased from 7 to 0.01 days, the isobiologically effective prescription dose decreased by a factor of three. As expected, {sub TUMOR} {sup 7}BEDVH did not significantly change as a function of radionuclide half-life but varied by 10% due to radionuclide dose distribution. Variations in reported radiobiological parameters caused {sub TUMOR} {sup 7}BED{sub 10} to deviate by up to 46%. Over the range of {sub OAR}{alpha}/{beta} values, {sub OAR} {sup 7}BED{sub 10} varied by up to 41%, 3.1%, and 1.4% for the lens, optic nerve, and lacrimal gland, respectively. Conclusions: BEDVH permits evaluation of the relative biological effectiveness for brachytherapy implants. For eye plaques, {sub TUMOR}BEDVH and {sub OAR}BEDVH were sensitive to implant duration, which may be manipulated to affect outcomes.

61 RADIATION PROTECTION AND DOSIMETRY↗

I-125 ROPES eye plaque dosimetry: Validation of a commercial 3D ophthalmic brachytherapy treatment planning system and independent dose calculation software with GafChromic{sup ®} EBT3 films

Purpose: The purpose of this study was to measure the dose distributions for different Radiation Oncology Physics and Engineering Services, Australia (ROPES) type eye plaques loaded with I-125 (model 6711) seeds using GafChromic{sup ®} EBT3 films, in order to verify the dose distributions in the Plaque Simulator™ (PS) ophthalmic 3D treatment planning system. The brachytherapy module of RADCALC{sup ®} was used to independently check the dose distributions calculated by PS. Correction factors were derived from the measured data to be used in PS to account for the effect of the stainless steel ROPES plaque backing on the 3D dose distribution.Methods: Using GafChromic{sup ®} EBT3 films inserted in a specially designed Solid Water™ eye ball phantom, dose distributions were measured three-dimensionally both along and perpendicular to I-125 (model 6711) loaded ROPES eye plaque's central axis (CAX) with 2 mm depth increments. Each measurement was performed in full scatter conditions both with and without the stainless steel plaque backing attached to the eye plaque, to assess its effect on the dose distributions. Results were compared to the dose distributions calculated by Plaque Simulator™ and checked independently with RADCALC{sup ®}.Results: The EBT3 film measurements without the stainless steel backing were found to agree with PS and RADCALC{sup ®} to within 2% and 4%, respectively, on the plaque CAX. Also, RADCALC{sup ®} was found to agree with PS to within 2%. The CAX depth doses measured using EBT3 film with the stainless steel backing were observed to result in a 4% decrease relative to when the backing was not present. Within experimental uncertainty, the 4% decrease was found to be constant with depth and independent of plaque size. Using a constant dose correction factor of T= 0.96 in PS, where the calculated dose for the full water scattering medium is reduced by 4% in every voxel in the dose grid, the effect of the plaque backing was accurately modeled in the planning system. Off-axis profiles were also modeled in PS by taking into account the three-dimensional model of the plaque backing.Conclusions: The doses calculated by PS and RADCALC{sup ®} for uniformly loaded ROPES plaques in full and uniform scattering conditions were validated by the EBT3 film measurements. The stainless steel plaque backing was observed to decrease the measured dose by 4%. Through the introduction of a scalar correction factor (0.96) in PS, the dose homogeneity effect of the stainless steel plaque backing was found to agree with the measured EBT3 film measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo dosimetry for {sup 103}Pd, {sup 125}I, and {sup 131}Cs ocular brachytherapy with various plaque models using an eye phantom

Purpose: To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing{sup 103}Pd, {sup 125}I, or {sup 131}Cs seeds with model-based dose calculations. Methods: Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including plaques consisting of a stainless steel backing and acrylic insert, and gold alloy backings with: short collimating lips and acrylic insert, no lips and silicone polymer insert, no lips and a thin acrylic layer, and individual collimating slots for each seed within the backing and no insert. Monte Carlo simulations are performed using the EGSnrc user-code BrachyDose for single and multiple seed configurations for the plaques in water and within an eye model (including nonwater media). Simulations under TG-43 assumptions are also performed, i.e., with the same seed configurations in water, neglecting interseed and plaque effects. Maximum and average doses to ocular structures as well as isodose contours are compared for simulations of each radionuclide within the plaque models. Results: The presence of the plaque affects the dose distribution substantially along the plaque axis for both single seed and multiseed simulations of each plaque design in water. Of all the plaque models, the COMS plaque generally has the largest effect on the dose distribution in water along the plaque axis. Differences between doses for single and multiple seed configurations vary between plaque models and radionuclides. Collimation is most substantial for the plaque with individual collimating slots. For plaques in the full eye model, average dose in the tumor region differs from those for the TG-43 simulations by up to 10% for{sup 125}I and {sup 131}Cs, and up to 17% for {sup 103}Pd, and in the lens region by up to 29% for {sup 125}I, 34% for {sup 103}Pd, and 28% for {sup 131}Cs. For the same prescription dose to the tumor apex, the lowest doses to critical ocular structures are generally delivered with plaques containing {sup 103}Pd seeds. Conclusions: The combined effects of ocular and plaque media on dose are significant and vary with plaque model and radionuclide, suggesting the importance of model-based dose calculations employing accurate ocular and plaque media and geometries for eye plaque brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-443: Geometric Uncertainties in Eye Plaque Dosimetry for a Fully Loaded 16 Mm COMS Plaque

Purpose: To determine the effect of geometric uncertainties in the seed positions in a COMS eye plaque on the central axis (CAX) dose. Methods: A Silastic insert was placed into a photopolymer 3D printed 16 mm COMS plaque, which was then positioned onto a custom-designed PMMA eye phantom. High resolution 3D images were acquired of the setup using a Siemens Inveon microPET/CT scanner. Images were acquired with the plaque unloaded and loaded with IsoAid I-125 seed shells (lack of silver core to minimize metal artifacts). Seed positions and Silastic thickness beneath each slot were measured. The measured seed coordinates were used to alter the seed positions within a standard 16 mm COMS plaque in Plaque Simulator v5.7.3 software. Doses along the plaque CAX were compared for the original and modified plaque coordinates using 3.5 mCi seeds with treatment times set to deliver 70 Gy to tumour apexes of 3.5, 5, and 10 mm height. Results: The majority of seeds showed length-wise displacement, and all seeds showed displacement radially outward from the eye center. The average radial displacement was 0.15 mm larger than the expected 1.4 mm offset, approximately half of which was due to increased Silastic thickness beneath each slot. The CAX doses for the modified seed positions were consistently lower for all tumour heights due to geometric displacement of the seeds; dose differences were found to increase to a maximum of 2.6% at a depth of ∼10 mm, after which they decreased due to the inverse square dose fall-off minimizing this effect. Conclusion: This work presents initial results of a broader dosimetric uncertainty evaluation for fully loaded COMS eye plaques and demonstrates the effects of seed positioning uncertainties. The small shifts in seed depths had noticeable effects on the CAX doses indicating the importance of careful Silastic loading. Funding provided by Alberta Cancer Foundation Grant #26655, Vanier Canada Graduate Scholarship, and Alberta Innovates Health Sciences Graduate Studentship.

60 APPLIED LIFE SCIENCES↗

SU-F-T-659: Nanoparticle-Aided Eye Plaque Radiotherapy

Purpose: Eye plaque brachytherapy is one of the approaches for radiotherapy treatment for ocular cancers: retinoblastoma and choroidal melanoma. This study, investigates the potential benefits of using gold nanoparticles to enhance therapeutic efficacy during eye plaque brachytherapy. Methods: The EYE PHYSICS Inc. Plaque Simulator program distributed by IsoAid, LLC, Port Richey, Florida was used. It is based on the superposition of dose contributions from individual seeds following the TG–43 formalism. Dose enhancement factor (DEF) values for feasible nanoparticle concentrations from previous studies was used to investigate the benefit of using nanoparticles to enhance dose to tumour or reduce dose to healthy tissue. The dose enhancement factor (DEF) represents the ratio of the dose deposited in tumour with nanoparticles divided by dose deposited in the tumour without nanoparticles. The investigation was done for I–125 and Pd–103 typical sources employed for eye plaque brachytherapy. The prescription dose used is 85 Gy. Results: Lower dose enhancement values were obtained for Pd–103. With DEF of 2 due to gold nanoparticles, critical structure doses reduce by a factor of 2. Optic disc dose is 6.69 Gy and 4.571 Gy, opposite retina dose is 4.064 and 2.484 Gy, lens dose is 12.66 Gy and 9.870 Gy, and fovea dose is 9.85 Gy and 7.275 Gy. With DEF of 3 due to gold nanoparticles, critical structure doses reduce by a factor of 3. Optic disc dose is 4.352 Gy and 2.975 Gy, opposite retina dose is 2.644 Gy and 1.618 Gy, lens dose is 8.322 Gy and 6.427 Gy, and fovea dose is 4.815 Gy and 4.737 Gy. Conclusion: The results of this research predict that using gold nanoparticles will lead to major sparing of dose to critical structures. The finding provides more impetus for the development of nanoparticle–aided brachytherapy.

60 APPLIED LIFE SCIENCES↗

Enhancement of Eye Tracking for Highly Dynamic Displays

Eye-Tracking and Sandia have established a collaborative arrangement whereby the two entities worked in a no-funds arrangement to study and share information about interface, software and algorithmic capabilities for dynamic, user-driven workflows. Sandia researchers developed the GazeAppraise algorithm for analysis of so-called “smooth pursuit” eye tracking datasets and used Eye Tracking, Inc’s experimental tasks and data to evaluate algorithmic performance. Although the results were quite positive, the partners ultimately decided it did not fit Eye Tracking’s market niche, and Sandia is pursuing opensource alternatives for disseminating the Gaze Appraise algorithms.

McNamara, Laura A.↗

Coincidence Anticipation Timing Responses with Head Tracking and Eye Tracking

Head tracking movements are common in interceptive tasks. The benefits of these movements are unclear. The purpose of this study was to compare coincidence anticipation timing (CAT) responses for a simulated approaching object when the eyes were used in tracking the object and when the head was used in tracking the object.A total of 29 subjects participated. A Bassin Anticipation Timer consisting of a track of sequentially illuminated lights was used to simulate an approaching object at velocities of 223 cm · s -1 to 894 cm · s -1 . Each velocity was used 10 times under 2 conditions. In one condition, subjects were told to turn the eyes with the stimulus. In the other condition, subjects viewed the stimulus through apertures and were told to turn the head with the stimulus. Subjects pushed a button to coincide with illumination of the final light on the track. Signed CAT errors, unsigned CAT errors, and variable CAT errors were compared between the head movement (HM) and eye movement (EM) conditions. No significant differences were noted for the signed errors (mean signed error at 894 cm · s -1 ; 10.3 ± 75.4 ms (HM), -16.1 ± 51.0 ms (EM). However, the unsigned and variable errors were significantly larger at some stimulus velocities in the head movement condition [mean unsigned error at 894 cm · s -1 : 82.6.0 ± 45.9 ms (HM), 59.0 ± 22.4 ms (EM); mean variable error at 894 cm · s -1 ; 78.0 ± 37.8 ms (HM), 49.2 ± 17.1ms (EM)]. DISCUSSION: Head movement did not result in improved CAT performance compared to eye movements. Further work will be required to determine whether these results are generalizable to situations where head tracking is required but apertures are not worn.

Biophysics↗

Inflow as a source of extraretinal eye position information.

Experiments were performed which show that subjects can reliably report when, and in which direction, loads were applied to their eyes in total darkness, which indicates that they were aware of inflow eye position information. Awareness of the inflow signal was not disrupted when the eyelids and conjunctiva were anesthetized and the eyelids were retracted from all possible contact with the scleral contact lens. Furthermore, the subjects maintained eye position when loads were applied to the eye in total darkness, showing that this inflow information can be used for extraretinal oculomotor control.

Skavenski, A. A.↗

A circadian rhythm in optic nerve impulses from an isolated eye in darkness.

Study of the circadian rhythm of optic nerve potentials recorded from the isolated eye of the sea hare Aplysia. The optic nerve activity in constant conditions is found to be clearly circadian and to obey the circadian rule for diurnal animals. In addition, the period length depends on the in vitro culturing solution. In seawater it is about 22 hr, but in culture medium it is 27 hr. The rhythm can be completely phase-shifted in one trial if the phase of the LD 12:12 Zeitgeber is advanced or delayed 4 hr. The rhythm in one eye can be phase-shifted in vivo independently of the other eye and in vitro independently of the rest of the animal. Thus, in the animal, the eye oscillators are, at most, only slightly influenced by each other or by other oscillators in the animal.

Jacklet, J. W.↗

The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

Laing, R. A.↗

Eye movements during afterimage tracking under sinusoidal and random vestibular stimulation

The smooth portion of the horizontal vestibulo-ocular reflex was analyzed in terms of the frequency response, relating slow-phase eye velocity to angular velocity of a rotating chair under four different cases: sinusoidal rotation about a vertical axis in total darkness, sinusoidal rotation during afterimage tracking, pseudorandom head rotation in total darkness, and pseudorandom head rotation during afterimage tracking. Eye movements were recorded using a photoelectric limbus tracking method. The observation that the presence of an afterimage during vestibular stimulation increases the velocity of slow-phase eye movements is in support of the theory that such slow-phase movements are generated, at least in part, by the perceived velocity of the target. Since the target is immobilized on the retina, this perceived velocity is clearly not generated by retinal slip, but rather by a mechanism related to the eye movement such as corollary discharge.

Yasui, S.↗

Eye movements - On-line measurement, analysis, and control

The paper outlines the plans and progress related to the development of a Programmed Eye-track Recording System and Eye-coupled Ubiquitous Scene-generator known by the acronym PERSEUS. Particular attention is given to the design and implementation of a computer-based real-time eye-tracking system with associated digital scenic display capability. The accurate eye-tracker developed by Cornsweet and Crane (1973) is selected for this purpose. The discussion covers automatic detection of fixations and saccades, automatic scanpath analysis, fixation-conditional stimulation, and digital scene generation. The all-digital approach to scenic simulation not only eliminates the camera optics and electromechanical servomechanisms of TV-model systems of simulation but also opens the way to the virtually unlimited sequencing of data-base contents and perspectives thereof.

Anliker, J.↗

Statistical evaluation of control inputs and eye movements in the use of instruments clusters during aircraft landing

Two different types of analyses were done on data from a study in which eye movements and other variables were recorded while four pilots executed landing sequences in a Boeing 737 simulation. Various conditions were manupulated, including changes in turbulence, starting position, and instrumentation. Control inputs were analyzed in the context of the various conditions and compared against ratings of workload obtained using the Cooper-Harper scale. A number of eye-scanning measures including mean dwell time and transition from one instrument to another were entered into a principal components factor analysis. The results show a differentiation between control inputs and eye-scanning behavior. This shows the need for improved definition of workload and experiments to uncover the important differences among control inputs, eye-scanning and cognitive processes of the pilot.

Dick, A. O.↗

Anisotropic responses to motion toward and away from the eye

When a rigid object moves toward the eye, it is usually perceived as being rigid. However, in the case of motion away from the eye, the motion and structure of the object are perceived nonveridically, with the percept tending to reflect the nonrigid transformations that are present in the retinal image. This difference in response to motion to and from the observer was quantified in an experiment using wire-frame computer-generated boxes which moved toward and away from the eye. Two theoretical systems are developed by which uniform three-dimensional velocity can be recovered from an expansion pattern of nonuniform velocity vectors. It is proposed that the human visual system uses two similar systems for processing motion in depth. The mechanism used for motion away from the eye produces perceptual errors because it is not suited to objects with a depth component.

Perrone, John A.↗

Time-locked time-histories - A new way of examining eye-movement data

A problem often encountered when eye-movement measurement is conducted is the choice of 'indices' or 'statistics' available to present such information. The present study reports the use of the Time-Locked Time-History as a technique of value in the examination and presentation of eye-movement data. Plots created using this technique are labeled time-locked time-histories as they illustrate subject eye lookpoint during a period of time before and after a certain time-locking event. Events that occur with some degree of repetition, such as the onset or termination of control activities, warning signals, or changes in indicator positions may be utilized as time-locking events. The present study reports the use of this technique in an eye-movement study using a secondary task in which the subject must discriminate specific types of information in the display.

Comstock, J. Raymond, Jr.↗