Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Study of Stark broadening of krypton helium-$\beta$ lines and estimation of electron density and temperature in NIF compressed capsules

Here the National Ignition Facility (NIF) diagnostic instrument manipulator (DIM) - based high resolution (dHIRES) x-ray spectrometer was used to measure the time evolution of the electron density (n e ) and temperature (T e ) in the hot spot of four NIF compressed capsules with 25 ps time resolution during the 'stagnation' phase. The electron density was inferred by comparing the measured Stark broadening of the krypton (Kr) Heβ spectral complex with theoretical calculations that include ion dynamic effects, and the electron temperature was inferred by comparing the measured ratio of the intensity of a dielectronically excited Li-like Kr line to the intensity of the Kr Heβ resonance line with calculations using the spectroscopic collisional radiative atomic model (SCRAM) and CRETIN collisional-radiative models. The inferred, time averaged n e values mainly agree with n e values from neutron diagnostics within uncertainties, but the neutron time-of-flight values of T ion are consistently higher than dHIRES T e values by 200–700 eV. The dHIRES measurements and measurement techniques, method of uncertainty analysis, and discussion of comparisons with measurements from neutron diagnostics are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elucidating Photoinduced Processes of Photosystem I Via Multidimensional Electronic and Vibrational Spectroscopies

This project was motivated by an overarching goal to elucidate the mechanism of energy and electron transfer that governs the efficient charge separation in photosystem I (PSI) complexes. PSI is a natural light harvesting complex that drives oxygenic photosynthesis in plants, algae, and cyanobacteria. It uses ~300 tightly packed chlorophylls (Chls) to absorb photons, transfer the excitation energy to the reaction center (RC), and generate a charge separated state with near unity quantum efficiency (QE). A better understanding of the mechanism of energy transfer and charge separation in PSI is required for understanding the high QE of natural light harvesting complexes, and it could lead to the further development of artificial photosynthetic systems for solar energy conversion and modification of light harvesting complexes to improve crop yields. We applied two-dimensional optical spectroscopies to different cyanobacterial photosystem I complexes, including PSI complexes that contain Chl f molecules, to map energy transfer pathways and gain insight into the efficient light harvesting of PSI. We used two-dimensional electronic spectroscopies (2DES) to map energy transfer in Chl a and Chl f containing PSI complexes. To investigate the Chl f PSI complexes, we modified our spectrometer to probe the lower energy states associated with Chl f molecules. We interpreted the 2DES spectra through global analysis procedures to generate maps of energy transfer. We also constructed a two-dimensional electronic vibrational (2DEV) spectrometer that will be used to investigate charge transfer transitions and dynamics within PSI complexes. Measurements were performed on model systems to establish general data analysis procedures for interpreting 2D spectra and gain insight into protein cofactor interactions.

14 SOLAR ENERGY↗

Optical design and efficiency measurement of an extreme ultraviolet high-resolution spectrometer for unresolved transition array research

Understanding the structures of the unresolved transition array (UTA) observed in extreme ultraviolet (EUV) spectra from many-electron atoms is crucial for various applications, including fusion science and nanolithography. Here, to measure the fine structure of the UTA from tungsten and tin at around 5 and 13.5 nm at the Tokyo electron beam ion trap, we developed a high-resolution EUV spectrometer. The designed spectrometer achieves a resolving power of λ/dλ > 5000 at 5 and 13.5 nm. The fabricated large-area grating was experimentally examined at beamline BL5B of the UVSOR synchrotron facility to evaluate the diffraction efficiencies and their variation across the ruled area. The measured diffraction efficiencies are 0.65% ± 0.07% at 5 nm (second order) and 7.9% ± 0.2% at 13.5 nm (first order). The variation in the diffraction efficiency across the ruled area is 2.2%, 13.6%, and 10.0% in zeroth, first, and second order diffractions, respectively. The discrepancies in diffraction efficiencies between the experiments and the calculations were 5.2%, 29%, and 35% for the zeroth, first, and second diffraction orders, respectively.

47 OTHER INSTRUMENTATION↗

First full Dalitz plot measurement in neutron 𝛽 decay using the Nab spectrometer and implications for new physics

Precision measurements of observables in neutron 𝛽 decay are used to test the standard model description of the weak interaction and search for evidence of new physics. The Nab experiment at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source was constructed to measure correlations in neutron decay by utilizing an asymmetric spectrometer and novel detection system to accurately reconstruct the proton momentum and electron energy for each 𝛽 decay. This work describes the detection of neutron 𝛽-decay products in the Nab spectrometer and presents the first full Dalitz plot representation of the phase space of neutron 𝛽 decay for all electrons >100 keV. In addition, new constraints are placed on a possible excited neutron state, hypothesized to explain the disagreement between the appearance and disappearance neutron lifetime techniques.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Confinement of relativistic electrons in a magnetic mirror en route to a magnetized relativistic pair plasma

Creating a magnetized relativistic pair plasma in the laboratory would enable the exploration of unique plasma physics relevant to some of the most energetic events in the universe. As a step toward a laboratory pair plasma, we have demonstrated an effective confinement of multi-MeV electrons inside a pulsed-power-driven 13 T magnetic mirror field with a mirror ratio of 2.6. The confinement is diagnosed by measuring the axial and radial losses with magnetic spectrometers. The loss spectra are consistent with ≤2.5 MeV electrons confined in the mirror for ∼1 ns. With a source of 1012 electron-positron pairs at comparable energies, this magnetic mirror would confine a relativistic pair plasma with Lorentz factor γ∼6 and magnetization σ∼40.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-Supplied Liquid Injection Field Desorption/Ionization Ion Source for an Orthogonal Time-of-Flight Instrument

A new implementation of a dedicated ion source for field ionization (FI), field desorption (FD), and liquid injection field desorption/ionization (LIFDI) for the JEOL AccuTOF GC series of orthogonal-acceleration time-of-flight instruments is presented. In contrast to existing implementations, this third-party LIFDI probe and source combination does not require the exchange of the entire ion source comprising ion source block and lens stack to switch from electron ionization (EI) to LIFDI. Rather, the methods may be swapped conveniently by only exchanging the ion source block for a mechanical probe guide and inserting the LIFDI probe in place of the standard direct insertion probe (DIP) via the vacuum lock. Further, this LIFDI setup does not require any changes of the electronics or software of the AccuTOF mass spectrometer because it is self-supplied in terms of power supply, observation optics, and computer control. The setup offers advanced FI/FD/LIFDI control features such as emission-controlled emitter heating current and emitter flash baking during elongated runs as required for gas chromatography-FI-mass spectrometry (MS). The LIFDI source and probe and its operation are reported in detail. FI spectra of the volatile analytes toluene, heptane, and pentafluoroiodobenzene are presented. LIFDI operation is demonstrated for the analysis of the saturated hydrocarbon dotriacontane and the low-mass hydrocarbon polymers polystyrene 484 and polystyrene 1050. Further, the air-sensitive 2nd-generation Hoveyda–Grubbs catalyst is analyzed by LIFDI-MS. For comparison with long-established LIFDI instrumentation, some of the spectra obtained with the new setup are also compared with those from a double-focusing magnetic sector instrument. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using neutrons and x rays to measure plasma conditions in a solid sphere of deuterated polyethylene compressed to densities of 35 g/cc at temperatures of 2 keV and pressures of 40 Gbar

This paper describes an experiment that shock compresses the center of a solid deuterated polyethylene sphere, CD 2 , to densities of 35 g/cc and temperatures of 2 keV with corresponding pressure of 40 Gbar. The design employs a strong spherically converging shock launched through a solid ball of material using a Hohlraum radiation drive. As the shock coalesces at the center it produces a hot spot that we characterize by measuring the x-ray self-emission and 2.45 MeV neutrons emitted. Two-dimensional images and time-resolved measurements of the x rays emitted determine the size and time duration of the hot spot, leading to an estimated 2k eV electron temperature. The neutron time of flight spectrometer measures an average ion temperature of 1.06 ± 0.15 keV and neutron yield of 7.0 (±0.5) × 10 9 DD neutrons. Our new distribution function tool enables us to create a forward model of the experimental data based on 1D radiation-hydrodynamic simulations, leading to a better understanding of the plasma conditions that produce the measured neutrons and x rays. Furthermore, our simulations indicate that the x rays are produced in a short-lived hot-dense core over tens of picoseconds, whereas the neutron emission continues for about 200 ps, as the hot core starts to expand, thereby leading to a lower mean temperature of the plasma during neutron production. This finding is in agreement with the experimental data, and we therefore conclude that the forward-modeling is a useful tool for inferring the conditions of the hot spot in a laser-driven implosion during burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarization observables 𝑇 and 𝐹 in the 𝛾⁢𝑝→𝜋 0 ⁢𝑝 reaction at CLAS

Pion photoproduction in the $\vec{γ}$$\vec{p}$ → π 0 p reaction has been measured in the FROzen Spin Target (FROST) experiment at the Thomas Jefferson National Accelerator Facility. In this experiment, circularly polarized photons with energies up to 3.082 GeV impinged on a transversely polarized frozen-spin target. Final-state protons were detected in the Continuous Electron Beam Accelerator Facility (CEBAF) Large Acceptance Spectrometer. The polarization observables T and F have been extracted for W from 1445 to 2525 MeV, of which the energy range is much broader, and the precision is better than the existing measurements in higher W ranges. The data generally agree with predictions of present partial-wave analyses but also show marked differences for higher W ranges. By incorporating the present data into the databases, the Scattering Analysis Interactive Data (SAID) fits have been improved with relatively small χ 2 and significant changes in the parameters of the (1910)1/2 + and N(2190)7/2 − have been found with the JüBo model.

particle production↗

Photo-Production of eta Mesons

In this work we present the GlueX experiment extensive high statistics measurements of the eta meson photo-production differential cross sections at beam energies between 3 GeV and 11.6 GeV. We compared the low energy (2.9 GeV< Ey < 5.9 GeV) differential cross section (d-sigma/d-Omega) results to previous experimental results from the Continuous Electron Beam Accelerator Facility (CEBAF) Large Acceptance Spectrometer (CLAS) collaboration. These (d-sigma/d-Omega) results are also compared to the theoretical isobar model EtaMAID2018 by Tiator et. al., and the Regge model by Nys et. al. The differential cross section d-sigma/dt is also presented and compared to the previous experimental results, and to the above models, in addition to a model by J. M. Laget. The high energy (6.2 GeV< Ey < 11.6 GeV) cross section results (d-sigma/d-Omega, and d-sigma/dt) are compared to the isobar model EtaMAID2018. These results will provide new constraints on eta photo-production mechanisms and high energy t-channel processes.

Kamel, Mahmoud↗

Electrons for Neutrinos

The ability of current and next generation accelerator based neutrino oscillation measurementsto reach their desired sensitivity requires a high level of understanding of the neutrino-nucleus interactions. This includes precise estimation of the relevant cross sections for the incident neutrino energy from the measured final state particles. Incomplete understanding of these interactions can skew the reconstructed neutrino spectrum and thereby bias the extraction of fundamental oscillation parameters and searches for new physics. In this talk, I will present new results of wide phase-space electron scattering data, collected with the CLAS spectrometer at the Thomas Jefferson National Accelerator Facility (JLab), where the reconstruction of the incoming lepton energy from the measured final state is being tested. Disagreements with current event generators, used in the analysis of neutrino oscillation measurements, are observed which indicate underestimation of nuclear effects.

43 PARTICLE ACCELERATORS↗

Lithium-like O 5+ Emission near 19 Å

Using a high-resolution grating spectrometer on the Livermore EBIT-I electron beam ion trap, we have measured three n = 3,4 → n = 1 K-shell emission lines in lithiumlike O 5+ , which are situated near the O VIII Lyman-α lines at 19 Å. Two of the resulting wavelengths agree well with the wavelengths of these lines we reported earlier, but the wavelength of the third line does not. In contrast, our new wavelengths now fully agree with those from resonant photo-absorption experiments on the PETRA III synchrotron facility.

74 ATOMIC AND MOLECULAR PHYSICS↗

The CLAS12 High Threshold Cherenkov Counter

The High Threshold Cherenkov Counter (HTCC) is one of the detector systems of the CLAS12 spectrometer, and is used to generate a fast trigger signal in electron scattering experiments in the polar angle range from 5°to 35°. The HTCC is installed in front of the drift chambers and introduces a minimal amount of additional material within the acceptance. The HTCC is one unit whose core component is a multifocal mirror that consists of 60 lightweight ellipsoidal mirrors. It is important that the HTCC provides efficient coverage of the CLAS12 forward acceptance with no gaps. In order to achieve this, each sector of the CLAS12 Forward Detector is covered by 2 identical half-sector mirrors that focus Cherenkov light on 8 phototubes. The HTCC has a total of 48 channels with Electron Tubes 9823QKB photomultipliers that have a 5-in quartz face plate to detect Cherenkov light. The system provides rejection of charged -mesons with momenta below 4.8 GeV for the reliable identification of scattered electrons. In this paper the details of the design, construction, calibration, and performance results of the HTCC are presented

Sharabian, Y. G.↗

Experimental characterization of hot-electron emission and shock dynamics in the context of the shock ignition approach to inertial confinement fusion

We report on planar target experiments conducted on the OMEGA-EP laser facility performed in the context of the shock ignition (SI) approach to inertial confinement fusion. The experiment aimed at characterizing the propagation of strong shock in matter and the generation of hot electrons (HEs), with laser parameters relevant to SI (1-ns UV laser beams with I ~10 16 W/cm 2 ). Time-resolved radiographs of the propagating shock front were performed in order to study the hydrodynamic evolution. The hot-electron source was characterized in terms of Maxwellian temperature, T h , and laser to hot-electron energy conversion efficiency η using data from different x-ray spectrometers. The post-processing of these data gives a range of the possible values for T h and η [i.e., T h [keV] ϵ (20, 50) and η ϵ (2%, 13%)]. These values are used as input in hydrodynamic simulations to reproduce the results obtained in radiographs, thus constraining the range for the HE measurements. According to this procedure, we found that the laser converts ~10% ± 4% of energy into hot electrons with T h = 27 ± 8 keV. The paper shows how the coupling of different diagnostics and numerical tools is required to sufficiently constrain the problem, solving the large ambiguity coming from the post-processing of spectrometers data. The effect of the hot electrons on the shock dynamics is then discussed, showing an increase in the pressure around the shock front. Furthermore, the low temperature found in this experiment without pre-compression laser pulses could be advantageous for the SI scheme, but the high conversion efficiency may lead to an increase in the shell adiabat, with detrimental effects on the implosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of the Pair Spectrometer in Hall D at Jefferson Lab

This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.

Somov, Alexander [Jefferson Lab]↗

Difficult Measurements of Materials Systems at Cryogenic Temperatures: Cryo-EELS and Cryo-4D-STEM

Scanning/transmission electron microscopy (S/TEM) in materials science has traditionally been accomplished at room temperature due to their solid state in this temperature range and relative insensitivity to radiolysis damage. Cooling to cryogenic temperatures tended to introduce instabilities such as vibration and drift and can lead to the buildup of carbon contamination or ice reducing contrast. The need to expand TEM experimental techniques into new fields such as quantum and battery materials led to new efforts to reduce these instabilities while achieving temperatures at or well below liquid nitrogen (77 K). Further, developments in detector and spectrometer technology brought new capabilities for high resolution electron energy loss spectroscopy (EELS) and scanning nanodiffraction (4D-STEM). These experimental modalities can require even tighter controls of drift, vibration, and exposure time. Here this presentation will discuss accomplishing difficult experiments at cryogenic temperatures in honor of the late Dr. Lena Kourkoutis who inspired and led many such experiments.

36 MATERIALS SCIENCE↗

First Results from the Thomson Scattering Diagnostic on the Large Plasma Device

We present the first Thomson scattering measurements of electron density and temperature in the Large Plasma Device (LAPD), a 22 m long magnetized linear plasma device at the University of California Los Angeles (UCLA). The diagnostic spectrally resolves the Doppler shift imparted on light from a frequency-doubled Nd:YAG laser when scattered by plasma electrons. A fiber array coupled to a triple-grating spectrometer is used to obtain high stray light rejection and discriminate the faint scattering signal from a much larger background. In the center of the plasma column, the measured electron density and temperature are about ne≈1.5×1013 cm−3 and Te≈ 3 eV, respectively, depending on the discharge parameters and in good agreement with Langmuir probe data. Optical design considerations to maximize photon count while minimizing alignment sensitivity are discussed in detail and compared to numerical calculations. Raman scattering off of a quartz crystal probe is used for an absolute irradiance calibration of the system.

Kaloyan, Marietta (ORCID:0000000182593038)↗

Horizontal 1 K refrigerator with novel loading mechanism for polarized solid targets

We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the CLAS12 detector systems places severe design and construction constraints on the refrigerator and its ancillary equipment, resulting in a horizontal cryostat with a length of 4 m. The 16 cm 3 target samples, consisting of frozen ammonia (NH 3 or ND 3 ), are loaded at the upstream end of the cryostat and moved to the beam-interaction region using a novel transport mechanism. At this location they are cooled with superfluid helium and polarized via dynamic nuclear polarization at 1 K and 5 T. In this manner samples can be replaced and cooled to 1 K in about 30 minutes without disturbing any elements of the electron beam line or particle detection system. In conclusion, we estimate that this method saved 18 days of valuable beam time over the course of a recent, 88-day long experiment.

Evaporation refrigerator↗

High-resolution spectroscopy of gaseous 83m Kr conversion electrons with the KATRIN experiment

Abstract In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous 83m Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The obtained results represent one of the major commissioning milestones for the subsequent direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the KATRIN beamline. Precise measurement of the narrow K-32, L 3 -32, and N 2,3 -32 conversion electron lines allowed to verify the eV-scale energy resolution of the KATRIN main spectrometer necessary for competitive measurement of the absolute neutrino mass scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗