Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrostatic Precipitator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Solar cell arcing: The role of outgassing and contamination

The effect of outgassing, venting, and thruster firing events on spacecraft system performance has been a long standing issue. Recent laboratory measurements on negatively biased high voltage solar cells at Physical Sciences Inc. (PSI) suggest that some currently designed and certainly future space power systems must address/re-evaluate this issue. Our observations show that exposing these cells to moderate levels (10 exp -3 torr-min) of H2O vapor enhances the arcing frequency, while heating to 85 C to remove water vapor significantly reduces the arc frequency. The interaction of the adhesive used to attach the cover glass to the solar cell with ambient water vapor is the key factor in determining arcing rates. Elimination of adhesive exposed to the environmental plasma reduces the arc frequency more than two orders of magnitude, and eliminates any sensitivity to H2O exposure. The adhesive may also become a source of spacecraft contamination. Macroscopic amounts were observed to blow off some arc events, and (we assume) electrostatically precipitate at other negatively biased locations. Data, analysis, and potential impact for future space platforms are discussed.

Marinelli, W. J.↗

Advanced Filter Technology For Nuclear Thermal Propulsion

The Scrubber System focuses on using HEPA filters and carbon filtration to purify the exhaust of a Nuclear Thermal Propulsion engine of its aerosols and radioactive particles; however, new technology may lend itself to alternate filtration options, which may lead to reduction in cost while at the same time have the same filtering, if not greater, filtering capabilities, as its predecessors. Extensive research on various types of filtration methods was conducted with only four showing real promise: ionization, cyclonic separation, classic filtration, and host molecules. With the four methods defined, more research was needed to find the devices suitable for each method. Each filtration option was matched with a device: cyclonic separators for the method of the same name, electrostatic separators for ionization, HEGA filters, and carcerands for the host molecule method. Through many hours of research, the best alternative for aerosol filtration was determined to be the electrostatic precipitator because of its high durability against flow rate and its ability to cleanse up to 99.99% of contaminants as small as 0.001 micron. Carcerands, which are the only alternative to filtering radioactive particles, were found to be non-existent commercially because of their status as a "work in progress" at research institutions. Nevertheless, the conclusions after the research were that HEPA filters is recommended as the best option for filtering aerosols and carbon filtration is best for filtering radioactive particles.

Castillon, Erick↗

Current Activities in the Advanced Exploration Systems ISRU Project

Media Filter MOXIE support: completed flow performance tests and initial dust loading tests of the MOXIE HEPA filter in the Mars Flow Loop Designed and fabricated prototype full-scale scroll filter for testing of renewable filter performance Mars Flow Loop upgrades: installed more sensitive instrumentation, improved imaging, and increased run duration capability Electrostatic Precipitator (ESP) Plasma-physics based model predicts particle charge and trajectory Characterizing dust environment from fluidized-bed injection dust environment using laser sheet visualization and Fine Particle Analyzer Sabatier Design Study Defined the Sabatier design space, including reactor type, thermal management, gas recycling/separation Modeled Sabatier systems with one or two reactors with different types of thermal management Adding thermal management schemes and recycling and gas separation to model Catalyst Screening Performing compression testing on new and used catalyst pellets Performing vibration testing on different catalyst pellet types under different load conditions Preparing to test catalysts for performance and degradation

In-Situ Resource Utilization↗

Electrostatically Enhanced Microbe Collection in the Troposphere and Stratosphere

The biggest challenge in aerobiology is the collection efficiency due to the microbe concentration in the atmosphere. The limited access to air samples has prevented systematic studies and some of the basic questions in the field of aerobiology remains open. The project goal was to develop a prototype system to demonstrate electrostatic precipitation for air microbe sampling.

Jerry J Wang↗

A Two-Stage Regenerable Filter for Collection and Disposal of Carbon Fines

NASA is investigating the use of the Plasma Pyrolysis Assembly (PPA), which is a methane post-processing technology with the goal to recover hydrogen from the Carbon dioxide Reduction Assembly (CRA) currently onboard the International Space Station (ISS). The PPA can theoretically recover 75% of hydrogen from methane produced by the CRA. During methane processing the PPA creates roughly 40 mg/hr of carbon dust when operating at 4 crew member levels. The unwanted fines need to be removed from the stream to prevent any clogging of downstream components. The Regenerable Carbon Filter (RCF) was designed by Umpqua Research Company to address the carbon particulate created in the PPA. The RCF includes two stages. The first is an electrostatic precipitator designed to collect ultrafine particles. The second is a low pressure drop physical filter. Both filters are made of heat tolerant materials to allow regeneration of the filtration capacity by O2 oxidation of captured carbon. This paper will discuss the RCF hardware and test plans.

Filtration, Environmental Control, Life Support↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Investigation of the relationship between particulate-bound mercury and properties of fly ash in a full-scale 100 MWe pulverized coal combustion boiler

The properties of fly ash in coal-fired boilers influence the emission of mercury from power plants into the environment. In this study, seven different bituminous coals were burned in a full-scale 100 MWe pulverized coal combustion boiler and the derived fly ash samples were collected from a mechanical hopper (MH) and an electrostatic precipitator hopper (ESP). The mercury content, specific surface area (SSA), unburned carbon, and elemental composition of the fly ash samples were analyzed to evaluate the correlation between the concentration of particulate-bound mercury and the properties of coal and fly ash. For a given coal, it was found that the mercury content in the fly ash collected from the ESP was greater than in the fly ash samples collected from the MHP. This phenomenon may be due to a lower temperature of flue gas at the ESP (about 135{sup o}C) compared to the temperature at the air preheater (about 350{sup o}C). Also, a significantly lower SSA observed in MH ash might also contribute to the observation. A comparison of the fly ash samples generated from seven different coals using statistical methods indicates that the mercury adsorbed on ESP fly ashes has a highly positive correlation with the unburned carbon content, manganese content, and SSA of the fly ash. Sulfur content in coal showed a significant negative correlation with the Hg adsorption. Manganese in fly ash is believed to participate in oxidizing volatile elemental mercury (Hg{sup 0}) to ionic mercury (Hg{sup 2+}). The oxidized mercury in flue gas can form a complex with the fly ash and then get removed before the flue gas leaves the stack of the boiler.

01 COAL, LIGNITE, AND PEAT↗

Mercury emissions control in coal combustion systems using potassium iodide: bench-scale and pilot-scale studies

Bench- and pilot-scale experiments were conducted using potassium iodide (KI) for capture and removal of Hg in air and coal combustion exhaust. Two bench-scale reactor systems were used: (1) a packed-bed reactor (PBR) packed with granular or powder KI and (2) an aerosol flow reactor (AFR) with injection of KI particles. It was found that a higher temperature, a higher concentration of KI, and a longer gas residence time resulted in a higher Hg removal efficiency. A 100% Hg removal was achieved in the PBR above 300{sup o}C using 0.5 g of powder KI and in the AFR above 500{sup o}C with a KI/Hg molar ratio of 600 at a 5.8 s residence time. The low KI injection ratio relative to Hg indicated that KI is highly effective for Hg removal in air. Formation of I{sub 2} vapor by the oxidation of KI by O{sub 2} at high temperatures, which then reacts with Hg to produce HgI{sub 2}, was identified as the pathway for removal. The pilot-scale experiments were conducted in a 160 kW pulverized coal combustor. KI was introduced in two ways: as a powder mixed with coal and by spraying KI solution droplets into the flue gas. In both cases the Hg removal efficiency increased with an increase in the feed rate of KI. Mixing KI powder with coal was found to be more effective than spraying KI into the flue gas. The Hg removal by KI was less efficient in the pilot-scale tests than in the bench-scale tests probably due to certain flue gas components reacting with KI or I{sub 2}. Hg speciation measurements in both bench- and pilot-scale experiments indicated no oxidized mercury in the gas phase upon introduction of KI, indicating that the oxidation product HgI2 was captured in the particulate phase. This is very beneficial in coal-fired power plants equipped with electrostatic precipitators where particulate-bound Hg can be efficiently removed. 27 refs., 8 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗

Enhancement of mercury capture by the simultaneous addition of hydrogen bromide (HBr) and fly ashes in a slipstream facility

Low halogen content in tested Powder River Basin (PRB) coals and low loss of ignition content (LOI) in PRB-derived fly ash were likely responsible for higher elemental mercury content (averaging about 75%) in the flue gas and also lower mercury capture efficiency by electrostatic precipitator (ESP) and wet-FGD. To develop a cost-effective approach to mercury capture in a full-scale coal-fired utility boiler burning PRB coal, experiments were conducted adding hydrogen bromide (HBr) or simultaneously adding HBr and selected fly ashes in a slipstream reactor (0.152 x 0.152 m) under real flue gas conditions. The residence time of the flue gas inside the reactor was about 1.4 s. The average temperature of the slipstream reactor was controlled at about 155{sup o}C. Tests were organized into two phases. In Phase 1, only HBr was added to the slipstream reactor, and in Phase 2, HBr and selected fly ash were added simultaneously. HBr injection was effective (>90%) for mercury oxidation at a low temperature (155{sup o}C) with an HBr addition concentration of about 4 ppm in the flue gas. Additionally, injected HBr enhanced mercury capture by PRB fly ash in the low-temperature range. The mercury capture efficiency, at testing conditions of the slipstream reactor, reached about 50% at an HBr injection concentration of 4 ppm in the flue gas. Compared to only the addition of HBr, simultaneously adding bituminous-derived fly ash in a minimum amount (30 lb/MMacf), together with HBr injection at 4 ppm, could increase mercury capture efficiency by 30%. Injection of lignite-derived fly ash at 30 lb/MMacf could achieve even higher mercury removal efficiency (an additional 35% mercury capture efficiency compared to HBR addition alone). 25 refs., 5 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

High volume, multiple use, portable precipitator

A portable high air volume electrostatic collection precipitator for analyzing air is provided which is a relatively small, self-contained device. The device has a collection electrode adapted to carry a variety of collecting media. An air intake is provided such that air to be analyzed flows through an ionization section with a transversely positioned ionization wire to ionize analytes in the air, and then flows over the collection electrode where ionized analytes are collected. Air flow is maintained at but below turbulent flow, Ionizable constituents in the air are ionized, attracted to the collection electrode, and precipitated in the selected medium which can be removed for analysis.

47 OTHER INSTRUMENTATION↗

New Methods to Determine the Electromagnetic Effects from Precipitation Static

The Electrostatics and Surface Physic Laboratory has devised a new method to determine the electromagnetic effects from precipitation static or p-static as its commonly called. P-static occurs as a result of triboelectric charging of granular materials or ice crystals bombarded onto the surfaces of air and/or space vehicles at high speeds. The electrostatic charge that builds up on the outer surface can have deleterious effects that arise during discharge events. These discharges can cause loss of communication to and from the vehicle from ground stations, EMI interference, radio frequency noise, etc… There are even cases of total loss of vehicles caused by p-static charging. We have developed a method to simulate the extensive tribocharging of insulating materials that occurs during p-static through the use of corona charging which allows testing to occur within a lab environment. These tests simulate the discharges that occur on rocket vehicles during ascent as a result of gas breakdown by performing the corona charging tests inside a vacuum chamber and subsequently removing the air. The simultaneous gas discharges emit electromagnetic interference (EMI) which can be captured and monitored.

Charles R Buhler↗

Ultra-low-level measurements of airborne fission products from the Fukushima Daiichi reactor accident using high volume collection systems at Savannah River National Laboratory

For this study, ultra-low-level measurements of radionuclides in air have been conducted at the Savannah River National Laboratory (SRNL) to determine the atmospheric concentration of fission products released following the Fukushima Daiichi reactor accident on March 11, 2011. Air filter samples were acquired from two high-volume collection systems (a traditional filter-based system and an electrostatic precipitator-based system) to monitor airborne radionuclide concentrations in the period covering from 2 weeks to 3 years after the disaster. The world-wide spread of low-level concentrations of airborne fission products from the Fukushima event provided a unique opportunity to demonstrate SRNL's electrostatic particle collection technology and other improvements in environmental monitoring developed at the Savannah River Site (SRS). Detecting and analyzing the release allowed a comprehensive test of SRS systems for monitoring environmental radioactivity. Gamma-ray-emitting fission products ( 131,132 I, 134,136,137 Cs, and 129,132 Te) and cosmogenic isotopes ( 7 Be and 22 Na) in air were detected and quantified by high-resolution gamma-ray spectroscopy at concentrations as low as 0.07 μBq per standard cubic meter (SCM) (50 mBq total 137 Cs), while plutonium content was quantified by thermal ionization mass spectrometry (TIMS) at concentrations as low as 6.5 × 10 –21 g/SCM (3.0 fg 239+240 Pu). Isotope concentrations measured at SRNL from gamma-ray spectroscopy were compared to independent measurements from Chapel Hill, NC, located approximately 370 km (230 mi) NE of SRNL. Meteorological modeling was also used to predict radionuclide transport from the location of release to both measurement locations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Automated system for removal and pneumatic transport of fly ash from electric precipitator hoppers

A system for removal and pneumatic transport of fly ash is examined, in which air pulses act on batches (pistons) of ash formed in a duct. Studies are made of the effect of several physical parameters on the force required to displace a piston of ash and these serve as a basis for choosing a system for removal and pneumatic transport of ash simultaneously from several hoppers of an electric precipitator. This makes it possible to separate the ash particles according to size without introducing additional components. Formulas are given for calculating the structural and dynamic parameters of this system and measurements of indirect dynamic parameters are used to calculate the input-output characteristics of the system. In order to optimize the system, configurations for summing several ducts into a single transport duct for pneumatic ash transport are proposed. Some variants of dry ash utilization and the advantages of producing of size-separated particles are considered.

01 COAL, LIGNITE, AND PEAT↗

Final Report Regulatory Off-Gas Emissions Testing on the DM1200 Melter System Using HLW and LAW Simulants

The operational requirements for the River Protection Project - Waste Treatment Plant (RPP-WTP) Low Activity Waste (LAW) and High Level Waste (HLW) melter systems, together with the feed constituents, impose a number of challenges to the off-gas treatment system. The system must be robust from the standpoints of operational reliability and minimization of maintenance.

54 ENVIRONMENTAL SCIENCES↗

Pilot Testing of Amine-Based Solvent at Low-Rank Coal Fired Power System

Conference presentation for the 2023 International Freiberg Conference on Circular Carbon Technologies, Rotterdam, Netherlands, September 24–29, 2023. This presentation describes pilot testing of an amine-based CO₂ capture system at Coal Creek Station, examining solvent performance, system design, and operating conditions for a low-rank coal-fired power plant. The Mitsubishi Heavy Industries KM CDR (KS-1) process is assessed using pilot-scale data to inform capture efficiency, solvent condition, and integration considerations.

01 COAL, LIGNITE, AND PEAT↗

Slipstream Testing of Amine-Based Solvents at a Low-Rank Coal-Fired Power Plant

Conference presentation for 38th Annual International Pittsburgh Coal Conference, Virtual, September 20–23, 2021. To better assess mitigation strategies for aerosol reduction to extend solvent life, the University of North Dakota Energy & Environmental Research Center (EERC) installed a pilot-scale CO 2 absorption system at a lignite-fired plant in central North Dakota. The pilot-scale system was operated using both commercial KS-1™ solvent and advanced KS-21™ solvent provided by Mitsubishi Heavy Industries (MHI). MHI’s proprietary amine emission reduction unit (AERU™) technology was installed downstream of the absorber columns to reduce solvent losses by recovering amines at the system outlet. Fine particulate loading was measured throughout the capture system with and without a WESP operating and using both solvents. Captured particulate was brought back to the EERC to be analyzed for chemical composition and to be examined by scanning electron microscopy for particulate structure. These variables were then correlated to performance of particulate control devices in reducing aerosol formation and solvent losses.

01 COAL, LIGNITE, AND PEAT↗

Particulate from Lignite Coal Combustion and Impact on Carbon Capture Aerosol Emissions

Conference presentation for 47th International Technical Conference on Clean Energy (Clearwater Clean Energy Conference), Clearwater, Florida, July 23–27, 2023. While aerosol formation is recognized as a leading cause of amine losses and degradation from postcombustion CO 2 capture systems, the factors that can lead to aerosol formation vary widely depending on fuel type, plant configuration, and operating conditions. All of these factors require measurement to fully characterize potential sources of aerosol-based amine losses and should be considered prior to implementing full-scale amine-based CO 2 capture.

01 COAL, LIGNITE, AND PEAT↗