Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Usage Reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Metallic Inks for Solar Cells: Cooperative Research and Development (Final Report)

This document describes the statement of work for National Renewable Energy Laboratory (NREL) as a subcontractor for Applied Nanotech, Inc. (ANI) for the Phase II SBIR contract with the Department of Energy to build silicon solar cells using non-contact printed, nanoparticle-based metallic inks. The conductive inks are based upon ANI's proprietary method for nanoparticle dispersion. The primary inks under development are aluminum for silicon solar cell back plane contacts and copper for top interdigitated contacts. The current direction of silicon solar cell technology is to use thinner silicon wafers. The reduction in wafer thickness reduces overall material usage and can increase efficiency. These thin silicon wafers are often very brittle and normal methods used for conductive feed line application, such as screen-printing, are detrimental. The Phase II program will be focused on materials development for metallic inks that can be applied to a silicon solar cell using non-contact methods. Uniform BSF (Back Surface Field) formation will be obtained by optimizing ink formulation and curing conditions to improve cell efficiency.

14 SOLAR ENERGY↗

Laboratory Testing of Demand-Response Enabled Household Appliances

With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses.The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Testing of Demand-Response Enabled Household Appliances

With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses. The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System and method for energy reduction based on history of reliability of a system

A system and method for managing operating parameters within a system for optimal power and reliability are described. A device includes a functional unit and a corresponding reliability evaluator. The functional unit provides reliability information to one or more reliability monitors, which translate the information to reliability values. The reliability evaluator determines an overall reliability level for the system based on the reliability values. The reliability monitor compares the actual usage values and the expected usage values. When system has maintained a relatively high level of reliability for a given time interval, the reliability evaluator sends an indication to update operating parameters to reduce reliability of the system, which also reduces power consumption for the system.

Sadowski, Greg↗

Technoeconomic Analysis of Microwave-Assisted Dry Reforming Integrated with Chemical Looping for Production of Methanol

Methanol is a key component in producing formaldehyde, acetic acid, and methyl tert -butyl ether (MTBE) and supports a wide array of industries, including plastics, textiles, and automotive. It also plays a growing role in renewable energy solutions. However, the conventional production of methanol involves steam reforming of methane, which is very energy-intensive and produces significant quantities of the greenhouse gas carbon dioxide. In this research, a chemical looping scheme is combined with dry reforming of natural gas in a novel microwave reactor to produce an industrial quantity of methanol. A heat exchanger network is developed to substantially reduce hot and cold utility usage. The effect of the cost of purchasing carbon dioxide from an external source for dry reforming, the capital cost of the microwave reactor, and the cost of electricity on the net present value is analyzed. Technoeconomic comparison with the conventional industrial process that produces methanol via steam reforming of methane indicates that the chemical looping generates a significant positive net present value along with a substantial reduction in carbon dioxide emissions while producing methanol significantly below the U.S. Department of Energy’s goal of $800/ton.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring Building Retrofit Strategies Using AutoBEM Under Future Weather Scenarios

This study evaluates the long-term effectiveness of energy conservation measures (ECMs) on building energy consumption using AutoBEM, a scalable modeling framework driven by the high-resolution Model America dataset. We simulated 18,951 buildings in Flagstaff, Arizona under four climate scenarios using Future Typical Meteorological Year (fTMY) weather files for six time periods spanning from 1980 to 2099. Six ECMs were analyzed across electricity and gas usage, including HVAC fuel-switching, insulation upgrades, and infiltration control. While some measures, such as reducing space infiltration by percentage, showed minimal or even negative impact on total energy savings at the aggregate level, they proved highly effective for specific building types. Conversely, HVAC electrification offers high gas reduction but shifts demand to electricity, highlighting critical trade-offs under different climate trajectories. Building-type-specific analysis under SSP5-RCP8.5 (2080–2099) revealed significant variation in ECM performance, underscoring the need for targeted retrofit strategies. This study demonstrates the power of combining fTMY projections with large-scale simulations to inform data-driven retrofit planning.

Chowdhury, Shovan [ORNL]↗

Occupant-driven end use load models for demand response and flexibility service participation of residential grid-interactive buildings

As demand response becomes increasingly used as a tool to support improved grid flexibility, it is important to consider that there are many potential types of energy end uses that may be used to support such flexibility. Residential appliances, often accounting for 30 % or more of residential energy use, are a currently untapped source of demand flexibility, particularly when aggregated together across homes. To date there has been very limited analysis of residential appliances for use as grid-interactive loads. As such, this research uses disaggregated energy end use data for 564 households, to model the electricity demand flexibility potential of the use of residential dishwashers, clothes washers, clothes dryers, ovens, and ranges (oven + stovetop) on both weekdays and weekends. This includes both at the building level, as well as aggregated to the grid level, specifically the Midcontinent Independent System Operator (MISO) region. This study was divided into two parts. Part 1 focuses on determining appliance-level loads, and Part 2, which involves aggregation to the grid. Findings suggest that among the studied appliances, clothes dryers provide the greatest demand reduction potential for most times of the day, followed by dishwashers and clothes washers. The maximum potential reduction for clothes dryers is found to be approximately at 11:00 a.m. and this potential sustains throughout most of the daytime period. When considering the willingness of households to participate, based on a survey of households in the Midwest region, clothes dryers still have the most potential for demand reduction. The availability of appliances for load modulation on weekdays and weekends indicates similar load reduction potential for all appliances. Overall, the results of this study suggest that there is an opportunity for shifting appliance usage to optimize grid efficiency and enhance demand response strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Active Flash: Out-of-core Data Analytics on Flash Storage

Next generation science will increasingly come to rely on the ability to perform efficient, on-the-fly analytics of data generated by high-performance computing (HPC) simulations, modeling complex physical phenomena. Scientific computing workflows are stymied by the traditional chaining of simulation and data analysis, creating multiple rounds of redundant reads and writes to the storage system, which grows in cost with the ever-increasing gap between compute and storage speeds in HPC clusters. Recent HPC acquisitions have introduced compute node-local flash storage as a means to alleviate this I/O bottleneck. We propose a novel approach, Active Flash, to expedite data analysis pipelines by migrating to the location of the data, the flash device itself. We argue that Active Flash has the potential to enable true out-of-core data analytics by freeing up both the compute core and the associated main memory. By performing analysis locally, dependence on limited bandwidth to a central storage system is reduced, while allowing this analysis to proceed in parallel with the main application. In addition, offloading work from the host to the more power-efficient controller reduces peak system power usage, which is already in the megawatt range and poses a major barrier to HPC system scalability. We propose an architecture for Active Flash, explore energy and performance trade-offs in moving computation from host to storage, demonstrate the ability of appropriate embedded controllers to perform data analysis and reduction tasks at speeds sufficient for this application, and present a simulation study of Active Flash scheduling policies. These results show the viability of the Active Flash model, and its capability to potentially have a transformative impact on scientific data analysis.

99 GENERAL AND MISCELLANEOUS↗

Spatially explicit land-energy-water future scenarios for cities: Guiding infrastructure transitions for urban sustainability

Cities control the majority of global human resource consumption and serve as hubs of major infrastructural networks. To offset their resource demands, cities derive goods and resources from regions well outside urban boundaries inducing stress and impacts on distal ecosystems. As cities grow, these stressors are likely to increase, depending on choices about how resource demands will be addressed through new infrastructures; hence, city governance is extremely important to future global sustainability. Yet, to support effective decision-making and infrastructure transitions, developing tangible city-scale alternative future scenarios is needed. We present a methodology for developing plausible spatially explicit alternative futures for city infrastructures and discuss the tradeoffs in land, energy, carbon, and water resources among alternative future pathways. We first estimate future city populations and urban boundaries and characterize future land cover scenarios. Future population along with residential housing and commercial characteristics are used to estimate current and future electricity and water demand. We characterize the energysheds of cities, which then become the spatial template for designing future electricity production scenarios. Future electricity mixes and spatial distributions of powerplants provide wide-ranging tradeoffs in carbon reduction, water use reduction, and land usage. Additionally, we explore future alternatives for meeting water supply demands. With this work, we emphasize the importance of translating scenarios into physical on-the-ground relevance in order to ensure transparent communication among city- and utility-governance. Unless spatially explicit future infrastructure scenarios are provided, we believe city-level goals will become difficult to implement, or even worse, result in unintended consequences on regional natural resources.

54 ENVIRONMENTAL SCIENCES↗

Metal–organic frameworks as O 2 -selective adsorbents for air separations

Oxygen is a critical gas in numerous industries and is produced globally on a gigatonne scale, primarily through energy-intensive cryogenic distillation of air. The realization of large-scale adsorption-based air separations could enable a significant reduction in associated worldwide energy consumption and would constitute an important component of broader efforts to combat climate change. Certain small-scale air separations are carried out using N 2 -selective adsorbents, although the low capacities, poor selectivities, and high regeneration energies associated with these materials limit the extent of their usage. In contrast, the realization of O 2 -selective adsorbents may facilitate more widespread adoption of adsorptive air separations, which could enable the decentralization of O 2 production and utilization and advance new uses for O 2 . Here, we present a detailed evaluation of the potential of metal–organic frameworks (MOFs) to serve as O 2 -selective adsorbents for air separations. Drawing insights from biological and molecular systems that selectively bind O 2 , we survey the field of O 2 -selective MOFs, highlighting progress and identifying promising areas for future exploration. As a guide for further research, the importance of moving beyond the traditional evaluation of O 2 adsorption enthalpy, ΔH, is emphasized, and the free energy of O 2 adsorption, ΔG, is discussed as the key metric for understanding and predicting MOF performance under practical conditions. Based on a proof-of-concept assessment of O 2 binding carried out for eight different MOFs using experimentally derived capacities and thermodynamic parameters, we identify two existing materials and one proposed framework with nearly optimal ΔG values for operation under user-defined conditions. While enhancements are still needed in other material properties, the insights from the assessments herein serve as a guide for future materials design and evaluation. Computational approaches based on density functional theory with periodic boundary conditions are also discussed as complementary to experimental efforts, and new predictions enable identification of additional promising MOF systems for investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reserve Li/SOC12 Battery Safety Testing

A reserve Lithium/Thionyl Chloride Battery concept is developed and undergoing feasibility testing in terms of performance, safety and abusive conditions. The feasibility of employing a battery of this type to replace thermal batteries in certain applications is demonstrated. Excellent performance of a Li/SOCl2 reserve battery is obtained across the temperature range from 0 C to +44 C. Performance improvement over the thermal battery usage is greater by a factor of 3 when discharge time and energy density are compared. Performance over an expanded temperature range is also possible. Safety and abusive testing is accomplished successfully on a series of five units. Further performance improvements can be achieved with regard to battery weight and volume reductions.

Dils, C. T.↗

Addressing Energy Demand through Demand Response. International Experiences and Practices

Demand response (DR) is a load management tool which provides a cost-effective alternative to traditional supply-side solutions to address the growing demand during times of peak electrical load. According to the US Department of Energy (DOE), demand response reflects “changes in electric usage by end-use customers from their normal consumption patterns in response to changes in the price of electricity over time, or to incentive payments designed to induce lower electricity use at times of high wholesale market prices or when system reliability is jeopardized.” 1 The California Energy Commission (CEC) defines DR as “a reduction in customers’ electricity consumption over a given time interval relative to what would otherwise occur in response to a price signal, other financial incentives, or a reliability signal.” 2 This latter definition is perhaps most reflective of how DR is understood and implemented today in countries such as the US, Canada, and Australia where DR is primarily a dispatchable resource responding to signals from utilities, grid operators, and/or load aggregators (or DR providers).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hexavalent Chromium Reduction by Zero Valent Iron in the Presence and Absence of TCE and CCl{sub 4} - 18445

Among the hundreds of chromium and chlorinated organic contaminated sites in the United States are Hanford and Savannah River Sites, which are of special interest to the U.S. Department of Energy (DOE). At the Hanford Site, chromate was used throughout the site as a corrosion inhibitor in reactor cooling water, which led to its discharge to the surface through spills during usage, disposal to cribs, and pipeline leaks. Chromium migration to the water table would result in rapid migration to the Columbia River, a main source of drinking water and salmon spawning. Also, of interest to the DOE is a blend of Cr(VI), TCE and CCl{sub 4} co-contaminants present in the soil subsurface and ground water and possible remediation strategies to reduce their impact on the health of communities downstream. This research study focused on degradation of hexavalent chromium, Cr(VI) to Cr (III) by zero valent iron Fe(0) in the presence and absence of TCE and CCl{sub 4} in batch reactors. It was determined that degradation of Cr(VI) by Fe (0) in the presence and absence of TCE and CCl{sub 4} is a complex surface limiting reaction and order of the reaction varies between second order initially (0∼1 hr) and zeroth order in the long term (∼ over 6 hours). The observed pseudo-first order rate constant for TCE and Cr(VI) degradation are 0.8869 hr{sup -1} for TCE and 1.217 hr{sup -1} for Cr(VI), respectively. The relative magnitudes of rate constants indicate that in the presence of excess ZVI, both Cr(VI) and TCE compete for the available ZVI but the degradation of Cr(VI) is much faster than that of TCE. Preliminary experiments on the degradation of CCl{sub 4} suggest it is not as readily degradable by ZVI as TCE, due to its non-polar nature. A mixture of ZVI and Fe(II) was used to achieve a suitable degradation pattern for CCl{sub 4} in the presence of Cr(VI); 82% degradation of CCl{sub 4} was achieved and the rate constant was found to be 0.3113 hr{sup -1}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration and Evaluation of an Advanced Oxidation Technology for Cooling Tower Water Treatment

A cooling tower is a heat rejection device that uses an evaporative cooling process to reject heat to the atmosphere from water cooled chilled water plant. Cooling towers are commonly applied to water cooled chilled water plants in large commercial buildings. The Silver Bullet alternative water treatment (AWT) technology is a non-chemical-based cooling tower water treatment technology. It is advertised as a simpler water treatment technology that can reduce cooling tower blowdown by increasing the CoC, which reduces monthly chemical costs, monthly operation and maintenance costs, and the amount of scale that collects on condenser water tubes and cooling towers. The primary focus of this evaluation was measuring cooling tower make up water usage pre- and post- installation of the AWT. In addition, annual reductions in cooling tower chemical costs, monthly water chemistry reports, ease of installation, and overall cost effectiveness were evaluated.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SolOpt

This software requires inputs of simple hot water system inventory information and general building usage information to calculate the energy and cost benefits of solar PV and solar SHW systems. This tool conducts and complex hourly simulation of solar PV and SHW energy production to optimize rooftop area. Four optimization criteria are offered that will change the sizes of the two solar energy systems: !'Jet-present value, discounted payback period, C02 reduction, and total renewable energy production. This tool includes the option for advanced system design inputs if they are known. This tool calculates energy savings, demand reduction, cost savings, incentives and building life cycle costs including: simple payback, discounted payback, net-present value, and savings to investment ratio. In addition this tool also displays the environmental benefits of a project.

Dean, Jesse↗

Size and Structure of the Sequence Space of Repeat Proteins

The coding space of protein sequences is shaped by evolutionary constraints set by requirements of function and stability. We show that the coding space of a given protein family— the total number of sequences in that family—can be estimated using models of maximum entropy trained on multiple sequence alignments of naturally occurring amino acid sequences. We analyzed and calculated the size of three abundant repeat proteins families, whose members are large proteins made of many repetitions of conserved portions of *30 amino acids. While amino acid conservation at each position of the alignment explains most of the reduction of diversity relative to completely random sequences, we found that correlations between amino acid usage at different positions significantly impact that diversity. We quantified the impact of different types of correlations, functional and evolutionary, on sequence diversity. Analysis of the detailed structure of the coding space of the families revealed a rugged landscape, with many local energy minima of varying sizes with a hierarchical structure, reminiscent of frustrated energy landscapes of spin glass in physics. This clustered structure indicates a multiplicity of subtypes within each family and suggests new strategies for protein design.

Jacopo Marchi↗

Wet Waste Hydrothermal Liquefaction and Biocrude Upgrading to Hydrocarbon Fuels: 2021 State of Technology

Each year the U.S. Department of Energy Bioenergy Technologies Office (BETO) assesses progress in their research and development efforts toward sustainable production of renewable fuels (DOE 2016) through the annual state of technology (SOT) assessment. The SOT assessment evaluates the impact of the year’s research progress on the modeled minimum fuel selling price (MFSP) for selected biofuel conversion pathways and measures the current state of the technology relative to defined goal case projections. Supply chain sustainability analysis to track and guide research toward improved greenhouse gas (GHG) emissions, energy usage, water usage and other environmental metrics for the pathway is performed by Argonne National Laboratory (Cai et al. 2018, 2020). Technical and cost targets for a projected goal case set for the year 2022 were previously established for the wet waste hydrothermal liquefaction (HTL) and biocrude upgrading pathway and summarized in a design report (Snowden-Swan et al. 2017). Process performance advancements made for HTL and biocrude hydrotreating have resulted yearly reductions in the modeled MFSP relative to the initial SOT (2018) (Snowden-Swan et al. 2020, 2021). This report summarizes the research and associated techno-economic analysis (TEA) for the pathway 2021 SOT. Methods and economic assumptions for the nth plant analysis used for the TEA are consistent with the design report (Snowden-Swan et al. 2017), with the exception of updates in the modeled cost year (2016) and income tax rate (21%).

09 BIOMASS FUELS↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗