Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Nonbonded interactions in membrane active cyclic biopolymers. IV - Cation dependence

Interactions of valinomycin and form of its analogs in several conformations with the central ions Li(+), Na(+), K(+), Rb(+) and Cs(+) are investigated as part of a study of the specific preference of valinomycin for potassium and the mechanisms of carrier-mediated ion transport across membranes. Ion binding energies and conformational potential energies are calculated taking into account polarization energy formulas and repulsive energy between the central ion and the ligand atoms for conformations representing various stages in ion capture and release for each of the two ring chiralities of valinomycin and its analogs. Results allow the prediction of the chirality and conformation most likely to be observed for a given analog, and may be used to synthesize analogs with a desired rigidity or flexibility. The binding energies with the alkali metal cations are found to decrease with increasing ion size, and to be smaller than the corresponding ion hydration energies. It is pointed out that the observed potassium preference may be explainable in terms of differences between binding and hydration energies. Binding energies are also noted to depend on ligand conformation.

Radhakrishnan, R.↗

Design trade-offs for residential retail tariffs and virtual power plants

Retail rate design and virtual power plants (VPPs) have the potential to shift customer electricity demand and provide economic benefits to utility customers. As the adoption of distributed energy resources (DERs) and flexible loads increases, retail tariff and program design can impact Bonbright's rate design principles including affordability, fairness, and economic efficiency. We model the effects of residential retail rates and VPP programs on power system costs in Massachusetts under a potential future system with high renewable energy and DER adoption. We model interactions among retail rate design, demand flexibility, and utility costs and identify trade-offs across different rate designs and VPP programs. We estimate that time-of-use (TOU) rates and VPP programs designed to avoid critical peak rates can lower overall system costs by 3.5 %-4.8 %. These lower costs translate to lower electricity bills for 62 %-91 % of customers, depending on the scenario. Although TOU rates with a critical peak VPP program can benefit all customer segments and are economically efficient, a VPP program with flat rates leads to the lowest overall bills for customers. We find that customers with loads that align with peak demand and who participate in critical peak VPP programs can underpay for their contribution to utility costs and shift costs to other customers. While our assumptions about mandatory TOU and/or critical peak pricing likely impact the magnitude of the results, the results highlight the trade-offs of these tariffs and programs and the importance of tariff and program design as demand becomes more flexible and responsive.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗

Wabash Hydrogen Negative Emissions Technology Demonstration

The objectives of the Wabash Hydrogen Negative Emissions Technology Demonstration Project (Wabash Project) are to develop and design all aspects of the scope, cost, characteristics and investment case of a world class flexible gasification, net negative carbon, hydrogen co-products power plant. The outcome of this undertaking is a complete set of deliverables that has been produced by a preeminent team of engineers, constructors, operators, and developers, building upon previous technology, utilizing cutting edge technology, and thoroughly defining all aspects of this fully integrated 21st Century Powerplant. The Wabash Project encapsulates several cross-cutting initiatives within the US Department of Energy, such as 100% hydrogen powered combustion turbine, geological carbon sequestration, coal with biomass gasification and hydrogen energy storage. The flexible gasifier at the Wabash Valley Resources plant is a slurry-fed, entrained flow, high-temperature, oxygen-blown gasifier that has been proven commercially to operate successfully on various coals and petroleum coke (petcoke). The ability to be fuel flexible and feed various biomass (woody biomass and agriculture residue) and petroleum waste (plastics) was evaluated during BP 1 (BP1). This involved the preparation and testing of feedstocks into slurries to determine what fuels can be fed to the gasifier. By utilizing a flexible oxygen-blown gasifier, the ability to address operational issues common to lower temperature biomass gasification, such as the handling of tars, can be mitigated. The overall goal is to achieve a design capable of carbon-negative emissions while leveraging the substantial investments made and operating experience already gained at the Wabash site.

01 COAL, LIGNITE, AND PEAT↗

OpenStudio Development, Maintenance, and Support

BEM is a key decision support tool for energy efficiency, demand flexibility, and electrification at the building and building stock levels. The OpenStudio SDK maximizes the value of BEM by enhancing the productivity, consistency, and transparency with which it is applied. OpenStudio enables BEM experts to encapsulate domain and process knowledge in such a way that makes it usable by a range of stakeholders.

BEM↗

Feedback control of vibrations in a moving flexible robot arm with rotary and prismatic joints

A robot with a long extendible flexible arm which can also undergo both vertical translation and rotary motion is considered. First, A distributed-parameter model for the robot arm dynamics is developed. It is found that the extending motion could enhance the arm vibrations. Then, a Galerkin-type approximation based on an appropriate time-dependent basis for the solution space is used to obtain an approximate finite-dimensional model for simulation studies. A feedback control for damping the motion-induced vibrations is derived by considering the time rate-of-change of the total vibrational energy of the flexible arm. The authors conclude with some simulation results for a special case with the proposed control law.

Wang, P. K. C.↗

Operational Simulation of Multi-Functional Charging Station for Sustainable Transportation

As transportation systems move toward electrification and decarbonization, multifunctional charging stations (MFCS) are emerging as key infrastructure for electric vehicles (EVs) and hydrogen fuel cell vehicles (HFCVs). This paper presents a simulation model of an MFCS that integrates solar photovoltaic (PV), wind power, battery storage, hydrogen (\mathrm{H}_{2}) production, dual-pressure \mathrm{H}_{2} storage, fuel cells, and dynamic grid interactions. The model simulates daily operations using 5 -minute resolution data to capture realtime variability in renewable energy (RE), demand, and electricity prices. A flexible dispatch algorithm dynamically allocates energy for EV charging, \mathrm{H}_{2} production, storage, and grid transactions while respecting system constraints. Results show that the MFCS effectively prioritizes RE usage, minimizes waste, meets diverse energy demands, and achieves net operational profit. The model serves as a valuable decision-support tool for designing and optimizing integrated clean energy hubs for zero-emission transportation.

Gbadegoye, Jeremiah [University of Tennessee, Knox↗

Guideline For Design Of Adaptive Structures

Guideline for design of adaptive structures specifies active members should be located at positions of maximum strain energy. Equations of motion of flexible structures formulated in terms of kinetic energies, strain energies, and direct measurements of forces. Maintaining precise dimensional control during assembly essential to assembly without large external loads or to prevent jamming of substructure preventing successful deployment. Active members used to prevent "binding" during deployment of structure. Then structure adjusted to precision shape requirement and adjusted during operation as required.

Utku, Senol↗

ComStock Measure Scenario Documentation: Standard Performance Heat Pump Rooftop Unit With New Windows

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot Development Progress to Demonstrate Electric Thermal Energy Storage (ETES) Using Low-Cost Particles

The rapid growth of variable renewable power generation increases the need to economically store electrical energy over durations up to several days in long-duration energy storage (LDES) applications. LDES can bridge the intermittency of increasing variable renewable energy (VRE) and facilitate emission-free dispatchable electricity to improve the resilience of the grid and provide reliable and potentially cost-effective energy. Several energy storage approaches including mechanical, chemical and electrochemical methods are currently deployed or under development. However, LDES requirements pose unique challenges for scalability, energy capacity, and cost. Electro-thermal energy storage (ETES) can store a large capacity of energy with site flexibility and has attracted significant interest for LDES purposes. This paper shows the progress of developing a demonstration test facility for particle ETES technology including pilot-scale component design and fabrication.

25 ENERGY STORAGE↗

Light-Emitting Diodes (LED) for Primary Animal Habitat Lighting in Highly Controlled Environments

Significant alterations in Biological Clock responses have been reported following sidereal time changes (e.g., Jet-lag), and exposure to microgravity (e.g., daytime sleepiness). Additionally, light reduces circulating melatonin (spectral specificity greatest between 450-500 nm). It was hypothesized that LEDs can replace the current light sources used in zero gravity and terrestrial research laboratories because of their small size, low mass, low energy consumption and long functional life. This report evaluates the capacity of LEDs to entrain the circadian system of rats as judged by measurement of overt behavioral circadian rhythms (activity, feeding, drinking). These data were collected in highly controlled environments similar to the shuttle Animal Enclosure Modules. Two groups were compared: control - animals exposed to standard cool-white fluorescent lights, and test - animals exposed to LEDs with a spectral power distribution matching the fluorescent lights. Gross locomotor activity, feeding and drinking frequencies were continuously monitored and stored at 10 minute intervals. Animals were exposed to the following photoperiods: 28 days of 12L:12D, 19 days of 24L:0D and 16 days of 12L:12D. Light intensities tested varied between 0.1 to 100 lux. Rats received food and water ad libitum, and temperature and humidity were controlled throughout the study. The general health status of all rats was acceptable for each day of this study. No incidents of aggressive behavior were observed. Growth, locomotor activity, food and water consumption were comparable for all groups of animals, i.e, the circadian characteristics of the animals under these conditions were comparable. These results indicate that LED arrays are as effective in maintaining circadian rhythm stability as the commonly used cool-white fluorescent light sources. LEDs with their flexible spectrum, low energy requirements and minimal heat production have advantages for some chronopharmacology studies and for microgravity animal habitats.

Winget, C. M.↗

ComStock Measure Scenario Documentation: Chiller Replacement

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at a subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations. This report describes the modeling methodology for a single end-use savings shape measure - chiller replacement - and briefly introduces key results. The full public dataset can be accessed on the ComStock (TM) data lake or via the Data Viewer at comstock.nrel.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Community-Engaged Energy Transition Planning in Holyoke

The overarching motivation of this project is to provide stakeholder-engaged research and education to enable a clean, equitable, and resilient energy transition. Presently, low-income communities and people of color are disproportionately burdened by environmental harm, while also being routinely left out of planning processes and benefits from infrastructure improvements. The Energy Transition Institute (ETI) addresses these issues in three ways: community engagement, educating diverse future leaders, and cutting-edge research. As municipalities across the Commonwealth plan their transition to a climate-friendly energy system, research from ETI will advance technical and social understanding of heating electrification, energy storage, demand flexibility, reliability and resiliency of power distribution infrastructure, with attention to equity. This will benefit surrounding communities, cities and towns across Massachusetts, and the global research community

14 SOLAR ENERGY↗

A redox-reversible A/B-site co-doped BaFeO 3 electrode for direct hydrocarbon solid oxide fuel cells

Solid oxide fuel cells (SOFCs) can directly convert the chemical energy in fuel to electrical energy with fuel flexibility; however, the conventional nickel-based anodes face great challenges due to coking upon direct oxidation of hydrocarbon fuels and redox instability. Thus, developing new anode materials which can provide high coking resistance as well as redox stability is crucial. In this work, Ba 0.6 La 0.4 Fe 0.8 Mo 0.1 Ni 0.1 O 3-δ (BLFMN) has been synthesized in air using a sol–gel combustion method, resulting in a dual phase consisting of a cubic BLFMN main phase and scheelite BaMoO 4 (BMO 4 ) secondary phase. By heat-treating the BLFMN dual phase in H 2 at 800 °C for 5 h, a metallic nanoparticle-decorated BLFMN triple phase compound comprising cubic BLFMN, cubic BaMoO 3 (BMO 3 ) and in situ exsolved FeNi 3 alloy was obtained. BLFMN was subsequently investigated as an electrode material for La 0.8 Sr 0.2 Ga 0.83 Mg 0.17 O 3-δ (LSGM) electrolyte (300 μm) supported SOFCs. Symmetrical cells using BLFMN as electrodes with the cell configuration of BLFMN//LSGM//BLFMN showed excellent redox reversibility and a peak power density (PPD) of 1.32 W cm -2 at 850 °C when using H 2 as fuel. Single cell with the cell configuration of BLFMN//LSGM//LSCF (La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ ) reached PPD of 1.61 and 0.41 W cm -2 at 850 °C when operating with H 2 and CH 4 fuel, respectively. Moreover, the single cell exhibit excellent stability (over 300 h) upon direct oxidation of hydrocarbon fuels of CH 4 and C 3 H 8 . This study indicates that BLFMN is a promising redox reversible and coking resistant anode for SOFCs.

08 HYDROGEN↗

Machine learning modeling and model predictive control of a closed-circuit reverse osmosis system

Closed-circuit reverse osmosis (CCRO) offers a flexible and energy-efficient alternative to conventional reverse osmosis by operating in a semi-batch mode that recycles brine, enabling higher recovery rates and reduced specific energy consumption (SEC). However, developing accurate, system-level dynamic models for CCRO remains challenging due to its nonlinear, multi-phase operation and sensitivity to variable feed water conditions. Traditional modeling approaches, such as NARMAX (nonlinear autoregressive moving average with exogenous inputs), often struggle to generalize across varying inlet feed concentrations, necessitating frequent parameter re-estimation and limiting their utility for real-time control applications. To address these limitations, we developed a long short-term memory (LSTM) neural network model trained on an extensive experimental data set from a CCRO pilot plant. The model accepts three inputs, feed flow rate, recirculation flow rate, and initial feed conductivity, and predicts three key outputs: reject conductivity, feed pump power draw, and recirculation pump power draw. We validated the LSTM model against experimental data, demonstrating its ability to distinguish between different feed conductivities and adapt to variable flow rates. Subsequently, we incorporated the LSTM model within a nonlinear model predictive control (MPC) scheme and conducted closed-loop simulations to optimize the integrated SEC (iSEC). In conclusion, the results project up to a 6% reduction in iSEC by using MPC to optimize performance over the entire experiment duration, without requiring any random excitation for data collection or parameter re-estimation.

Desalination↗

Enhancing Short-Term Flexibility through Characterization of HVDC Transmission Systems

Efficient power grid operation hinges on maintaining safety and reliability through adaptable system flexibility standards. However, in a future power grid characterized by extensive renewable energy integration, conventional system flexibility and predetermined requirements may falter under extreme conditions. This paper addresses the formidable challenge of sustaining secure and dependable power grid operations under these circumstances, emphasizing the role of controllable high voltage direct current (HVdc) transmission systems in amplifying overall system flexibility and tackling operational complexities. To quantitatively assess short-term flexibility and its associated economic benefits from HVdc within specific regions, we propose a Power Flow Distribution Factors (PTDFs) based approach. This methodology takes into account both dispatchable generators and HVdc systems, pinpointing their contributions. Through an analysis of the Western Electricity Coordinating Council (WECC) system, we demonstrate the practical application of this approach to scrutinize the impacts of existing and future HVdc lines.

Operational Flexibility, Multi-terminal HVdc, tran↗

Direct Air Capture Recovery of Energy for CCUS Partnership (DAC RECO 2 UP) Final Technical Report

The “Direct Air Capture Recovery of Energy for CCUS Partnership (DAC RECO 2 UP)” project employs a team approach and supports the U.S. Department of Energy Office of Fossil Energy and Carbon Management’s (DOE-FECM) goal to decrease the cost of capture through the testing of existing direct air capture (DAC) materials in integrated field units that produce a concentrated carbon dioxide (CO 2 ) stream of at least 95% purity. Solid-amine CO 2 adsorption-desorption contactor technology, proven in the laboratory, is undergoing high-fidelity design/validation. Recoverable energy is readily available from a large number of commercial locations where DAC can be deployed; therefore, advancing the fidelity of energy recovery to directly reduce the cost of DAC is a key project objective. In addition, many commercial facilities have low-concentration CO 2 vents that are uneconomical to treat alone but could provide more efficient mass and thermal transport to DAC systems with integrated energy recovery and flexible CO 2 treatment capabilities. Technology scale-up leverages past research and occurs in a commercially relevant environment at the National Carbon Capture Center. Prescreening techno-economic analysis, risk assessments, and life cycle analysis are being performed by experienced team members. Results of the project will address critical technical barriers that, when solved, will improve the capital and operating costs of DAC while validating commercial relevance of cost and product quality/need.

54 ENVIRONMENTAL SCIENCES↗

TCF - Sustainable Well Cement for Geothermal, Thermal Recovery, and Carbon Storage wells

Primary cementing is the most important operation performed on a subterranean well. Cement, placed in the annulus between the casing and the formations, serves as a hydraulic seal preventing fluids and gas migrations, protecting steel casing from corrosion, and supporting the well structure. Poor cementing jobs can be directly responsible for wells not reaching their full capacity, casing corrosion, compromised well integrity and, in the worst-case scenarios, well collapse. Geothermal, thermal recovery, and carbon storage wells offer environments that are especially difficult for cements to survive while the required lifespan of these wells can be years. In these wells currently used cements cannot provide durable well integrity, and new solutions are necessary. The necessity of stabilizing the electric grid, increasing its flexibility, and providing energy on demand will further expand the market of durable cement solutions for applications in high-temperature underground reservoir thermal energy storage wells (HT RTES). The design challenges of special cement systems for such wells originate from chemistry limitations of currently used well cements, aggressive environments, temperature and repeated shock conditions associated with them, and very weak formations that are not uncommon in these wells. During the last 70 years the most common systems for thermal-well construction have been Ordinary Portland Cement (OPC) (absolute majority of the wells), silica-lime system, and high aluminum cement-containing formulations. The major issues of calcium-silicate hydrates, that form during the hydration of OPC resulting in hardened material, are their poor chemical resistance to acids due to the calcium interactions with acid anions followed by its eventual dissolution, even in mild acids, such as carbonic acid from CO 2 dissolution, and inadequate bonding to the steel causing serious casing corrosion problems (Sugama & Pyatina, 2019). Performance of OPC-based cement may be significantly improved with organic additives; however, those are limited by their temperature stability. An alternative to calcium-silicate cement was developed by BNL and commercialized by Halliburton as ThermaLock TM cement. Calcium-aluminate-phosphate-based chemistry of the material allowed overcoming acid-resistance problems of OPC, especially in CO 2 -rich geothermal environments. In 2012-2015, building upon this experience, BNL developed Thermal Shock Resistant Cement (TSRC) with the support of Geothermal Technology Office (GTO) of DOE. TSRC has high-temperature stable chemistry, superior properties of cement-metal casing bond and corrosion protection (4-times better than currently used OPC-based formulation), significantly outperforms common well-cements in thermal-shock tests, has self-healing properties, and like ThermaLock TM is CO 2 resistant incorporating carbonate ions into stable hydrates (Gill et al., 2012).

15 GEOTHERMAL ENERGY↗