Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equipment Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Zero-Emission Transit Bus Needs Assessment

The transition to zero-emissions vehicles (ZEVs) in public transit has gained traction due to significant federal investments from the Bipartisan Infrastructure Law (BIL) and the Inflation Reduction Act (IRA). This needs assessment, commissioned by the Joint Office of Energy and Transportation and conducted by researchers at the Idaho National Laboratory, explores the current state of electrification in transit agencies, identifying barriers to implementation, potential funding sources, and operational considerations necessary for a successful transition. The assessment involved qualitative interviews with representatives from 19 transit service providers across diverse geographic regions. Key findings highlight the challenges related to bus facilities and operations, which require careful planning for charging infrastructure and maintenance capabilities to accommodate battery electric buses (BEBs) and hydrogen fuel cell buses (HFCBs). Agencies reported operational hurdles due to the shorter range of BEBs compared to diesel buses, necessitating revised scheduling and routing strategies. Despite these challenges, many agencies expressed optimism about their capacity to adapt. Funding availability emerged as a critical factor influencing the transition to ZEVs. While agencies welcomed increased financial support, particularly from the Low or No Emission Grant Program (Lo-No), concerns about the sustainability of this funding and the ongoing operational costs were prevalent. The need for a comprehensive funding inventory was underscored to ensure transit agencies are aware of all available resources. Technological constraints were significant barriers to ZEV adoption. The limited range of BEBs was frequently cited as a concern, leading to operational challenges and reliability issues. Agencies reported difficulties in sourcing replacement parts, which exacerbated downtime and maintenance challenges. Workforce development and training were identified as pivotal for a successful transition. Many agencies rely heavily on manufacturers for technician training, highlighting the need for scalable training programs that equip staff with the necessary skills to maintain electric powertrains effectively. This assessment offers actionable recommendations for the Joint Office, including enhancing outreach to transit agencies, developing resources for effective utility partnerships, and facilitating comprehensive training programs. Establishing a zero-emission bus evaluation program to track performance metrics such as cost, range, and reliability could provide valuable insights for transit agencies. The needs assessment provides a detailed examination of the challenges and opportunities facing transit agencies in their transition to zero-emissions bus fleets. By addressing these issues through targeted support, stakeholders can collaboratively work towards a cleaner, more sustainable public transportation system that benefits all communities.

33 - ADVANCED PROPULSION SYSTEMS↗

Dynamic hosting capacity analysis for distributed photovoltaic resources—Framework and case study

Distributed photovoltaic systems can cause adverse distribution system impacts, including voltage violations at customer locations and thermal overload of lines, transformers, and other equipment resulting from high current. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current static methods for determining hosting capacity tend to either consider infrequent worst-case snapshots in time and/or capture coarse time and spatial resolution. Because the duration of violations cannot be captured with these traditional methods, the metric thresholds used in these studies conservatively use the strictest constraints given in operating standards, even though both worse voltage performance and higher overloads may be temporarily acceptable. However, assessing the full details requires accurately capturing time-dependence, voltage-regulating equipment operations, and performance of advanced controls-based mitigation techniques. In this paper, we propose a dynamic distributed photovoltaic hosting capacity methodology to address these issues by conducting power flow analysis for a full year. A key contribution is the formulation of time aware metrics to take these annual results and identify the hosting capacity. Through a case study, we show that this approach can more fully capture grid impacts of distributed photovoltaic than traditional methods and the dynamic hosting capacity was 60%–200% higher than the static hosting capacity in this case study.

14 SOLAR ENERGY↗

Energy, power, and infrastructure demands from electrifying airport ground support equipment at United States airports

As the airline industry seeks to reduce costs and transition to clean energy, electric ground support equipment is emerging as a favorable option. The integration of electric ground support equipment into airport operations requires careful planning for vehicle deployment, charging infrastructure, and grid impacts. We develop a flexible, bottom-up modeling framework to assess energy and infrastructure needs across more than 300 U.S. airports. Our analysis estimates site-specific power and energy demand, equipment counts by type, charger requirements, and costs. Here we quantify the magnitude of new electrical loads created by the electrification of airport ground support equipment, finding that peak power demand at the largest airports can reach up to 20 megawatts, with annual electricity consumption approaching 51,000 megawatt-hours. We further show that behind-the-meter battery energy storage systems and solar photovoltaic systems can reduce peak load and lower total system costs by as much as 10 million dollars.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Automatic Fault Detection & Diagnostics: Residential Market Analysis

This report provides an overview of the market potential for automated fault detection and diagnostics (AFDD) in the residential sector, focusing on embedded AFDD in central air conditioners (CAC) and air-source heat pumps (ASHP) as well as the use of smart diagnostic tools to ensure quality installation of CAC/ASHP equipment. The contents include background on AFDD, stakeholder engagement efforts, a technology assessment of AFDD and smart diagnostic tools, residential CAC and ASHP market trends, a characterization of the CAC and ASHP installed base, a synopsis of utility provider programs, and market barriers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Corrosivity Screening of Pyrolysis Bio-Oils by Short-Term Alloy Exposures. Laboratory Analytical Procedure (LAP), Issue Date: May 12, 2022

Bio-oils contain organic acids and oxygenated compounds that can lead to corrosion issues during bio-oil processing and storage. This Laboratory Analytical Procedure (LAP) allows for rapid screening of a bio-oil's corrosivity without the need for complex equipment and long-term exposures. A robust and repeatable method for assessing the corrosivity of bio-oils is necessary in order to remove materials degradation as an obstacle to research, upgrading, use and storage of bio-oils. This LAP involves the incubation of a representative alloy, 410 stainless steel (410 SS), specimen in bio-oil over a period of 48 hours at 50 degrees C in a sealed container. The corrosive species in the bio-oil react with and deplete alloy elements such as iron (Fe) and/or chromium (Cr) from the specimen into the bio-oil solution. The depletion of Fe and Cr from the specimen results in a significant mass loss that can be recorded. The mass loss is directly correlated to the corrosivity of a bio-oil. Examples of bio-oils in scope include the ones produced by fast pyrolysis and catalytic fast pyrolysis, as well as liquids produced from hydrothermal liquefaction.

09 BIOMASS FUELS↗

Automation of Solid Oxyde Electrolyzer Cell (SOEC) & Stack Assembly

The work performed under this agreement before the No/Go decision amounted to the following: 1. Preliminary manufacturing requirements defined by business sensitivity, baseline processes & risk assessment; 2. Process & materials development, in-line gauge exploration, and preliminary automation work used to reduce risk & further refine equipment specifications; 3. “Request for Quote” issued to multiple suppliers for major equipment; 4. Application specific equipment, hardware, and fixturing will be more beneficial to fabricate inhouse; 5.Current proposals & estimates meet cycle time, capital spend, & direct labor; space is on target but requires awareness; 6. Team will continue to explore opportunities to reduce risk (dry time, traceability); 7. Go / No-Go, Purchase Orders, Equipment build & commissioning next All other future task were not completed because during the Go /No-Go decision it was confirmed this project was a "No-Go" and did not proceed past BP1; these included the following: 1. Preliminary manufacturing requirements defined by business sensitivity, baseline processes & risk assessment; 2. Process & materials development, in-line gauge exploration, and preliminary automation work used to reduce risk & further refine equipment specifications; 3. “Request for Quote” issued to multiple suppliers for major equipment; 4. Application specific equipment, hardware, and fixturing will be more beneficial to fabricate inhouse; 5. Current proposals & estimates meet cycle time, capital spend, & direct labor; space is on target but requires awareness; 6. Team will continue to explore opportunities to reduce risk (dry time, traceability) In final preparation of the termination of the Automation of Solid Oxyde Electrolyzer Cell (SOEC) & Stack Assembly, Cummins has purchased no equipment with government funds, and there is no government-owned property in Cummins possession related to this project. Minimal labor and travel were completed and paid. This acts as the Final technical report and concludes our business with DOE on this grant.

36 MATERIALS SCIENCE↗

Enabling Industrial Re-Use of Large-Format Additive Manufacturing Molding and Tooling

Large-format additive manufacturing (LFAM) is an enabling manufacturing technology capable of producing large parts with highly complex geometries for a wide variety of applications, including automotive, infrastructure/construction, and aerospace mold and tooling. In the past decade, the LFAM industry has seen widespread use of bio-based, glass, and/or carbon fiber reinforced thermoplastic composites which, when printed, serve as a lower-cost alternative to metallic parts. One of the highest-volume materials utilized by the industry is carbon fiber (CF)-filled polycarbonate (PC), which in out-of-autoclave applications can achieve comparable mechanical performance to metal at a significantly lower cost. Previous work has shown that if this material is recovered at various points throughout the manufacturing process for both the lab and pilot scale, it can be mechanically recycled with minimal impacts on the functional performance and printability of the material while significantly reducing the feedstock costs. End-of-life (EOL) CF-PC components were processed through industrial shredding, melt compounding, and LFAM equipment, followed by evaluation of the second-life material properties. Experimental assessments included quantitative analysis of fiber length attrition, polymer molecular weight degradation using gel permeation chromatography (GPC), density changes via pycnometry, thermal performance using dynamic mechanical analysis (DMA), and mechanical performance (tensile properties) in both the X- and Z-directions. Results demonstrated a 24.6% reduction in average fiber length compared to virgin prints, accompanied by a 21% decrease in X-direction tensile strength and a 39% reduction in tensile modulus. Despite these reductions, Z-direction tensile modulus improved by 4%, density increased by 6.8%, and heat deflection temperature (HDT) under high stress retained over 97% of its original value. These findings underscore the potential for integrating mechanically recycled CF-PC into industrial LFAM applications while highlighting the need for technological innovations to mitigate fiber degradation and enhance material performance for broader adoption. This critical step toward circular material practices in LFAM offers a pathway to reducing feedstock costs and environmental impact while maintaining functional performance in industrial applications.

additive manufacturing↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

Best Practices for Timing Attack Mitigation

GPS signals play essential roles in the electric subsector by providing precision timing used to synchronize and record measurements from a range of equipment. However, previous research has demonstrated that GPS signals can be spoofed or jammed relatively easily in order to interfere with timing-reliant equipment. This document outlines utility best practices for mitigating against timing attacks in the electric subsector based on an assessment of the difficulty and impact of realistic timing attacks and testing of the effectiveness of technologies capable of mitigating them. This analysis builds on research establishing the vulnerability of GPS-reliant timing equipment to jamming and spoofing by elaborating the difficulty, consequences, and mitigations for timing attacks that adversaries might realistically attempt. While timing attacks are relatively low-cost, low-sophistication, and capable of systemic consequences in the electric subsector, they can be effectively mitigated through well-targeted and diverse mitigations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Regional Coordination on Transmission Needs for Power System Resource Adequacy [Slides]

Resource adequacy (RA) is an important component of bulk power system reliability that addresses whether there are sufficient resources available to meet electricity demand at all times. RA analysis is used to assess whether the planned power system will provide reliable electricity to consumers while accounting for equipment outages, weather variability, and load uncertainty. Coordination between regions can enable resource sharing to meet RA needs if sufficient transmission capacity exists. Transmission's role in RA coordination can be particularly pronounced for large power systems like the U.S. electricity grid which contains geographically diverse demand and weather-dependent resources. Depending on the level of coordination desired, existing inter-regional transmission capacity may not be sufficient. This study is designed to assess optimal pathways for the development of inter-regional transmission in the U.S. under varying levels of RA coordination. Results can inform long-term grid infrastructure planning and provide insights into potential benefits of greater coordination for generation and transmission planning between regional U.S. power systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Residential HVAC Fault Data Collection Plan – Refrigerant Undercharge and Overcharge Faults

Heating, ventilation, and air-conditioning (HVAC) systems can develop faults due to poor installation practices or gradual wear and tear, leading to decreased HVAC system’s efficiency, compromised thermal comfort, and shortened equipment lifespan (EERE, 2018). Automated fault detection and diagnosis (AFDD) technologies offer a solution by identifying energy-wasting HVAC faults, such as inadequate indoor airflow and incorrect refrigerant charge, and guiding technicians to enhance system efficiency. In the realm of residential HVAC, AFDD can be implemented through various fault detection and diagnosis capabilities, sensor configurations, and target applications. These technologies typically fall into three categories: smart diagnostic tools, original equipment manufacturer (OEM)-embedded tools, and add-on tools. Smart diagnostic tools employ temporarily installed sensors to directly measure HVAC system characteristics, while OEM-embedded tools utilize factory-installed sensors to identify faults or assess system performance. However, both these types of AFDD technologies are often only accessible for high-end HVAC equipment or require additional sensor installation by qualified technicians, resulting in high investment costs and limited applicability for low-income residential buildings. On the other hand, add-on tools rely solely on data from smart thermostats and meters to detect faults by continuously analyzing equipment runtime or energy usage. As smart thermostat and meter costs decrease and their prevalence increases, these tools can be readily deployed in low-income residential buildings. However, they possess limited capabilities as they rely solely on basic trend analysis. Enhancing such tools with advanced machine learning algorithms can significantly improve their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Workforce Readiness Index: A Local and Regional Assessment Tool for Energy Sector Preparedness

Building up a workforce that is properly trained and adequately sized is essential to ensuring that the deployment of energy generation sources in the United States meets future energy demand. Workforce development to support supply chain or large infrastructure investments typically occurs at a local level. However, there is a critical gap in understanding where and to what extent regional workforces are equipped to meet the needs of an energy industry. The Workforce Readiness Index ("the index") was developed to assess and compare energy sector workforce readiness across the United States at the county level to provide granular information to various stakeholders such as industry members, state decision makers, and training program developers. Workforce readiness is defined as the ability to recruit from the general labor market, transition workers with comparable skill sets, and train a workforce using scalable or existing training programs near a specific location. Therefore, the index evaluates readiness levels based on the likelihood that a county possesses the workforce development infrastructure needed to support the occupations required by an energy-related industry or sector. Furthermore, the index offers a standardized yet flexible approach that captures regional variations and highlights local strengths and challenges.

17 WIND ENERGY↗

Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska

The purpose of this report is to determine the effects that extreme cold temperatures have on electric vehicles (EVs) and electric vehicle supply equipment (EVSE). The adoption of EVs in extreme cold weather presents challenges that require careful analysis of efficiency and charging infrastructure. This report, "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska," explores how EVs and EVSE perform in temperatures as low as -40 degrees C (-40 degrees F), focusing on real-world data from Teslas in Alaskan winter conditions. The findings indicate that EVs can successfully function in extreme cold, though efficiency is significantly affected. Vehicles stored in heated environments outperformed those stored outdoors, with efficiency dropping by up to 69% for outdoor storage. Despite these challenges, none of the vehicles experienced failures that prevented travel. Storing EVs indoors led to benefits such as faster preconditioning and improved efficiency, while charging in extreme cold, though slower, remained functional. Ultimately, the report concludes that with proper precautions and best practices, EVs are viable transportation solutions in cold climates. Investing in enclosed, heated storage is recommended to maximize efficiency and minimize battery strain. As advancements in battery chemistry and thermal management progress, EV adoption in extreme climates is expected to become even more feasible.

33 ADVANCED PROPULSION SYSTEMS↗

Development of the Mobile Systems for Conditioning of Disused Sealed Radioactive Sources in Serbia - 20105

Sealed radioactive sources (SRS) are being used worldwide in the field of medicine, agriculture, industry and research. They can be found in mobile as well as stationary devices. SRS contains radioactive material that is (a) permanently sealed in a capsule or (b) closely bounded and in a solid form. The capsule or material of an SRS should be strong enough to maintain leak tightness under the conditions of use and purpose for which the source was designed, also in case of accidents. In this case only emitted radiation is utilized. Firstly, the hazard from external radiation has to be considered, but the possibility of contamination due to fracture of the capsule should not be disregarded. The radioactive sources are composed of the radiating isotope contained in the filling medium, the single or double isotope holder that partially or totally surrounds the filling medium, the outer cover that contains the parts mentioned above and the capsule closed airtightly by welding or using some other method. The capsule must be tested for leakage periodically. If the SRS is no longer needed (e.g. replaced by a different technique) or it becomes useless for the intended application (e.g. the activity becomes too weak, the equipment containing the source works poorly or becomes obsolete, the source is damaged or leaking) it is considered disused. Disused sealed radioactive sources (DSRS) are typically conditioned and disposed if a facility is available. If the disposal option is not available, conditioned DSRS should be stored under proper conditions. In some cases, the radionuclide(s) in DSRS can be recovered/recycled or the DSRS can be repurposed for other applications. Conditioning of DSRS ensures containment of the radioactive material, provides confinement for leaking sources, provides sufficient radiation shielding, reduces storage/disposal volume by allowing consolidation of multiple sources into a single storage/disposal container, facilitates transport operations and contributes to safety and security as well. Typically, conditioning technologies are deployed either as permanently installed stationary systems in centralized or mobile on-site waste processing facilities, or in a mobile configuration. Centralized stationary facilities provide a single processing location for multiple users that requires transport of the waste to the facility. On the other hand, mobile systems may be provided for the selection and application of the optimum technology for a specific waste stream (such as DSRS) by bringing the process to the point where the waste is generated. In addition, mobile systems could offer additional flexibility by sharing equipment among multiple waste generating sites for processing campaigns that vary in duration, from very short periods to several years. The term 'mobile processing system' refers to any radioactive waste processing system or component which is designed to be transportable and which is not considered permanently installed. Two mobile system for conditioning of disused sealed radioactive sources are developed in the Public Company Nuclear Facilities of Serbia. Development of these mobile systems was supported by SRB9005 national project via Technical Cooperation of the IAEA. The first mobile system, built inside the 20 feet ISO container, will be used for conditioning of DSRS category 3 to 5. The second mobile system, built inside the 7 m long vehicle (Iveco Daily Van), will be used for dismantling of ionizing smoke detectors mostly with Am-241 sources. Designs of the mobile systems were defined in cooperation with two companies from Belgium (Belgoprocess and Leniko) and a Croatian company Ekoteh as well as with the support of the IAEA experts. The generic safety assessment and operational procedures for the mobile systems are developed. Based on safety assessment the acceptance criteria and operational limits and conditions are established. Operational procedures include: (a) equipment and material requirements, (b) assembling procedure of the mobile unit, (c) procedure for acceptance of devices for dismantling and conditioning, (d) dismantling procedure for devices to recover the DSRS, (e) characterization of DSRS, (f) encapsulation procedure of DSRS, (g) disassembling procedure of the mobile unit, and (h) keeping records, identification and traceability. In addition, radiation safety, health safety, security and emergency preparedness plans are prepared. The generic safety assessment and operational procedures could be updated with site specific requirements, DSRS inventory, and different needs for future customers. Developed mobile systems could be used in all situations when it is feasible to perform conditioning of DSRS on the spot in the county and worldwide. Development of these mobile units was just the first step to create the Reference Center for Radioactive Waste Treatment and Disused Radioactive Sources Conditioning for Small Facilities which can become a regional training center in the future, and/or as a tool for comprehensive national search and secure programmes. In the next phases development of e-learning platforms and blended learning packages as well as application for the IAEA Qualified Technical Centre (QTC) for the management of DSRS is foreseen. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of a tomography-informed polyhedral discrete element modelling approach for complex-shaped granular woody biomass in stress consolidation

The design of handling equipment for granular biomass primarily requires experiments. Discrete element models (DEM) can provide designers with detailed insight into the behaviour of granular materials. However, granular biomass comprising complex-shaped particles is difficult to model with DEM. A tomography-informed DEM approach and an exhaustive assessment of the ability of the approach to predict the bulk behaviour of milled pines using experimental data is presented. Nano-CT scan was conducted to obtain 3D particle surface geometries as the basis for particle shape approximation by a polyhedral model and a sphero-polyhedral model. These models were applied in the simulation of a compressibility test. Our parametric study showed that particle Young's modulus and restitution coefficient are the two main properties influencing the simulated bulk behaviour of the DEM particles and that the level of approximating DEM particle shape for real particles is critical for accurately replicating the bulk behaviour of milled pines. The polyhedral model demonstrated better suitability than its sphero-polyhedral counterpart for modelling pine particles. The polyhedral model calibrated in a compressibility test was then applied in the simulations of a friction test without additional parameter tuning. Interlocking was dominant in the shear of bulk pine particles. Remarkably, the polyhedral model predicted the frictional behaviour of the pine particles when compared to the experimental results. The limitations of the model, as well as possible ways for enhancement, are discussed. This work provided novel insights into the suitability of complex-shaped DEM models for granular woody biomass.

Biomass flow↗

Vulnerabilities in Satellite Communications Underscore Threat to Critical Infrastructure

INL analysts assess critical infrastructure sectors leveraging satellite communications (SATCOM) are likely inadvertently increasing the attack surface caused by inherent vulnerabilities in equipment and communications pathways. A lack of ownership regarding security in SATCOM ecosystems creates pervasive information security risk, and the obfuscation of patching responsibility means the mitigation of publicly and privately disclosed vulnerabilities is difficult to track. With these factors in consideration, INL analysts assess the number of attacks against SATCOM is likely to increase in the next decade as threat actors exploit these vulnerabilities.

99 GENERAL AND MISCELLANEOUS↗

Modeling Failure of Electrical Transformers due to Effects of a HEMP Event

Understanding the effect of a high-altitude electromagnetic pulse (HEMP) on the equipment in the United States electrical power grid is important to national security. A present challenge to this understanding is evaluating the vulnerability of transformers to a HEMP. Evaluating vulnerability by direct testing is cost-prohibitive, due to the wide variation in transformers, their high cost, and the large number of tests required to establish vulnerability with confidence. Alternatively, material and component testing can be performed to quantify a model for transformer failure, and the model can be used to assess vulnerability of a wide variety of transformers. This project develops a model of the probability of equipment failure due to effects of a HEMP. Potential failure modes are cataloged, and a model structure is presented which can be quantified by the results of small-scale coupon tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗