Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error Floors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Radiometric Correction and Calibration of SAR Images

A technique for producing radiometrically calibrated SAR image products is described. The output imagery is corrected to represent a measurement of the ground reflectivity or radar cross section. The sources of calibration errors are discussed and the appropriate forms of the radar equation as applied to SAR-image data are reviewed. A key result is the radar equation dependence on the azimuth reference function used in processing. A radiometric correction algorithm for use in an operational SAR correlator is presented. This algorithm has the characteristic that it is fully reversible. Additionally, it can be applied equally to detected or complex SAR images, and it allows for the subtraction of the estimated noise floor in the image but does not require this procedure.

Freeman, Anthony↗

Sensitivity of WFIRST Coronagraph Broadband Contrast Performance to DM Actuator Errors

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory (JPL), we have investigated the sensitivity of a Hybrid Lyot Coronagraph (HLC) broadband contrast performance to DM actuator errors and actuator limits. Considered case include drifts in actuator gains or actuator response curves, paired actuators, as well as the limits imposed by a neighboring-actuator rule. Actual data about the actuator drifts and the knowledge about the paired-actuators obtained in several DM characterization experiments conducted at JPL, as well as the neighboring-actuator rule implemented on the OMC testbed were used in simulations. We obtained good agreement between the model prediction and the testbed measurement in terms of static HLC contrast floor and contrast chromaticity.

Sidick, Erkin↗

SU-G-206-17: RadShield: Semi-Automated Shielding Design for CT Using NCRP 147 and Isodose Curves

Purpose: Computed tomography (CT) exam rooms are shielded more quickly and accurately compared to manual calculations using RadShield, a semi-automated diagnostic shielding software package. Last year, we presented RadShield’s approach to shielding radiographic and fluoroscopic rooms calculating air kerma rate and barrier thickness at many points on the floor plan and reporting the maximum values for each barrier. RadShield has now been expanded to include CT shielding design using not only NCRP 147 methodology but also by overlaying vendor provided isodose curves onto the floor plan. Methods: The floor plan image is imported onto the RadShield workspace to serve as a template for drawing barriers, occupied regions and CT locations. SubGUIs are used to set design goals, occupancy factors, workload, and overlay isodose curve files. CTDI and DLP methods are solved following NCRP 147. RadShield’s isodose curve method employs radial scanning to extract data point sets to fit kerma to a generalized power law equation of the form K(r) = ar^b. RadShield’s semiautomated shielding recommendations were compared against a board certified medical physicist’s design using dose length product (DLP) and isodose curves. Results: The percentage error found between the physicist’s manual calculation and RadShield’s semi-automated calculation of lead barrier thickness was 3.42% and 21.17% for the DLP and isodose curve methods, respectively. The medical physicist’s selection of calculation points for recommending lead thickness was roughly the same as those found by RadShield for the DLP method but differed greatly using the isodose method. Conclusion: RadShield improves accuracy in calculating air-kerma rate and barrier thickness over manual calculations using isodose curves. Isodose curves were less intuitive and more prone to error for the physicist than inverse square methods. RadShield can now perform shielding design calculations for general scattering bodies for which isodose curves are provided.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-P-53: RadShield: Semi-Automated Shielding Design for CT Using NCRP 147 and Isodose Curves

Purpose: Computed tomography (CT) exam rooms are shielded more quickly and accurately compared to manual calculations using RadShield, a semi-automated diagnostic shielding software package. Last year, we presented RadShield’s approach to shielding radiographic and fluoroscopic rooms calculating air kerma rate and barrier thickness at many points on the floor plan and reporting the maximum values for each barrier. RadShield has now been expanded to include CT shielding design using not only NCRP 147 methodology but also by overlaying vendor provided isodose curves onto the floor plan. Methods: The floor plan image is imported onto the RadShield workspace to serve as a template for drawing barriers, occupied regions and CT locations. SubGUIs are used to set design goals, occupancy factors, workload, and overlay isodose curve files. CTDI and DLP methods are solved following NCRP 147. RadShield’s isodose curve method employs radial scanning to extract data point sets to fit kerma to a generalized power law equation of the form K(r) = ar^b. RadShield’s semi-automated shielding recommendations were compared against a board certified medical physicist’s design using dose length product (DLP) and isodose curves. Results: The percentage error found between the physicist’s manual calculation and RadShield’s semi-automated calculation of lead barrier thickness was 3.42% and 21.17% for the DLP and isodose curve methods, respectively. The medical physicist’s selection of calculation points for recommending lead thickness was roughly the same as those found by RadShield for the DLP method but differed greatly using the isodose method. Conclusion: RadShield improves accuracy in calculating air-kerma rate and barrier thickness over manual calculations using isodose curves. Isodose curves were less intuitive and more prone to error for the physicist than inverse square methods. RadShield can now perform shielding design calculations for general scattering bodies for which isodose curves are provided.

60 APPLIED LIFE SCIENCES↗

A Time-Varying Model for Predicting Formaldehyde Emission Rates in Homes

Recent studies have succeeded in relating emissions of various volatile organic compounds to material mass diffusion transfer using detailed empirical characteristics of each of the individual emitting materials. While significant, the resulting models are often scenario specific and/or require a host of individual component parameters to estimate emission rates. This study developed an approach to estimate aggregated emissions rates based on a wide number of field measurements. We used a multi-parameter regression model based on previous mass transfer models to predict formaldehyde emission rate for a whole dwelling using field-measured, time-resolved formaldehyde concentrations, air exchange rates, and indoor environmental parameters in 63 California single-family houses built between 2011 and 2017. The resulting model provides time-varying formaldehyde emission rates, normalized by floor area, for each study home, assuming a well-mixed mass balance transport model of the home, and a well-mixed layer transport model of indoor surfaces. The surface layer model asserts an equilibrium concentration within the surface layer of the emitted materials that is a function of temperature and RH; the dwelling ventilation rate serves as a surrogate for indoor concentration. We also developed a more generic emission model that is suitable for broad prediction of emission for a population of buildings. This model is also based on measurements aggregated from 27 homes from the same study. We showed that errors in predicting household formaldehyde concentrations using this approach were substantially less than those using a traditional constant emission rate model, despite requiring less unique building information.

54 ENVIRONMENTAL SCIENCES↗

Tactile Cueing as a Gravitational Substitute for Spatial Navigation During Parabolic Flight

INTRODUCTION: Spatial navigation requires an accurate awareness of orientation in your environment. The purpose of this experiment was to examine how spatial awareness was impaired with changing gravitational cues during parabolic flight, and the extent to which vibrotactile feedback of orientation could be used to help improve performance. METHODS: Six subjects were restrained in a chair tilted relative to the plane floor, and placed at random positions during the start of the microgravity phase. Subjects reported their orientation using verbal reports, and used a hand-held controller to point to a desired target location presented using a virtual reality video mask. This task was repeated with and without constant tactile cueing of "down" direction using a belt of 8 tactors placed around the mid-torso. Control measures were obtained during ground testing using both upright and tilted conditions. RESULTS: Perceptual estimates of orientation and pointing accuracy were impaired during microgravity or during rotation about an upright axis in 1g. The amount of error was proportional to the amount of chair displacement. Perceptual errors were reduced during movement about a tilted axis on earth. CONCLUSIONS: Reduced perceptual errors during tilts in 1g indicate the importance of otolith and somatosensory cues for maintaining spatial awareness. Tactile cueing may improve navigation in operational environments or clinical populations, providing a non-visual non-auditory feedback of orientation or desired direction heading.

Montgomery, K. L.↗

Accuracy Analysis of a Robotic Radionuclide Inspection and Mapping System for Surface Contamination

The mapping of localized regions of radionuclide contamination in a building can be a time consuming and costly task. Humans moving hand-held radiation detectors over the target areas are subject to fatigue. A contamination map based on manual surveys can contain significant operator-induced inaccuracies. A Fanuc M16i light industrial robot has been configured for installation on a mobile aerial work platform, such as a tall forklift. When positioned in front of a wall or floor surface, the robot can map the radiation levels over a surface area of up to 3 m by 3 m. The robot's end effector is a commercial alpha-beta radiation sensor, augmented with range and collision avoidance sensors to ensure operational safety as well as to maintain a constant gap between surface and radiation sensors. The accuracy and repeatability of the robotically conducted contamination surveys is directly influenced by the sensors and other hardware employed. This paper presents an in-depth analysis of various non-contact sensors for gap measurement, and the means to compensate for predicted systematic errors that arise during the area survey scans. The range sensor should maintain a constant gap between the radiation counter and the surface being inspected. The inspection robot scans the wall surface horizontally, moving down at predefined vertical intervals after each scan in a meandering pattern. A number of non-contact range sensors can be employed for the measurement of the gap between the robot end effector and the wall. The nominal gap width was specified as 10 mm, with variations during a single scan not to exceed {+-} 2 mm. Unfinished masonry or concrete walls typically exhibit irregularities, such as holes, gaps, or indentations in mortar joints. These irregularities can be sufficiently large to indicate a change of the wall contour. The responses of different sensor types to the wall irregularities vary, depending on their underlying principles of operation. We explored capacitive, ultrasound, and optical Laser range sensors. The unshielded capacitive range sensors were found to be influenced by objects in their vicinity, and to have comparatively low sensitivity. Therefore they were not used for gap measurement. We did, however, use them successfully to detect obstacles in the field of motion of the sensor head. The four sensors pointing diagonally from four corners of the sensor head are capacitive range sensors, which stop the robot motion any time a pre-set threshold signal level is exceeded. Ultrasound range sensors were found to have good resolution. The ultrasound beam was frequently deflected sideways by the wall's roughness, resulting in a spurious signal peaks. On the other hand, ultrasound signals are inherently insensitive to variations of the optical surface properties. Laser range sensing proved to be generally less noisy than ultrasound measurements. The aforementioned sensitivity to the target surface's optical properties was not evident on grey, non-reflective surfaces. On such surfaces, laser range sensing was found to be superior to ultrasound measurements. Occasionally, however, surface reflectivity and specularity caused erroneous measurements. The computational burden of measuring and filtering the sensor data in real time made it impractical to control the robot directly based on sensor feedback. The robot performs a first horizontal surface range scan merely to gage the surface profile. During the subsequent passes, the robot records the radiation measurements, while recording the range data for the next pass, with the range sensor positioned below the radiation sensor. The decoupling of measurements from robot control prevents the robot controller from responding to spurious sensor signals, ensuring steadier and safer radiation surveying. The controller is configured to accept either optical or ultrasound range signals, so as to respond better to user-specific requirements. A detailed analysis of non-contact range sensors and control for the automated mapping of surface contamination has been presented. The Contamination Survey Machine was tested and is operational.

42 ENGINEERING↗

Satellites map the oceans

Satellite remote sensing systems, both operational and planned, for monitoring the ocean winds, temperatures, chlorophyll concentrations, ice flows, and the sea surface and ocean floor topographies are described. Seasat demonstrated the effectiveness of scatterometer measurements for measuring wind velocities and directions, and a new scatterometer may be launched on the U.S. Navy NROSS spacecraft in 1988. The NOAA-7 and -8 satellites carry IR sensors to monitor ocean temperatures, and can thus forewarn of the onset of El Nino. Ocean currents are traced with radar altimeters such as the one planned for the Topex satellite as a follow-on to instrumentation tested during the three-month lifetime of the Seasat satellite. Further analytical development is required, however, to improve the data analyses of the altimeter and scatterometer readings, and to account for errors introduced by the observed features and the interposed atmospheric phenomena.

Hibbs, A. R.↗

Preliminary study of the application of the Timation 3 satellite to earth physics

The Timation 3 is a timing and navigation satellite originally planned for launch in December 1972 into a circular orbit at 98 deg inclination 14,000 km altitude with gravity gradient stabilization. An error analysis indicates a satellite position uncertainty of about one meter, 80 percent of which is attributable to the assumed gravity model errors. The remaining uncertainties have a period equal to that of the satellites and can be filtered out yielding an effective uncertainty of about 10 cm in the study of phenomena having different periodicities. The accomplishment of these results depends on a careful consideration of solar radiation pressure taking account of the spacecraft reflecting properties and variations in the presentation area. Consideration is also given to the displacement of the laser reflectors from the center of mass of the spacecraft and to the dynamic coupling of any libration in attitude with the orbital motion. The results indicate that a good set of well distribution laser observations of Timation 3 could yield determinations of polar motion, sea floor spreading, solid earth tides, and earth rotation at the 10 cm level.

Carpenter, L.↗

Microarcsecond relative astrometry from the ground with a diffractive pupil

The practical use of astrometry to detect exoplanets via the reflex motion of the parent star depends critically on the elimination of systematic floors in imaging systems. In the diffractive pupil technique proposed for space-based detection of exo-earths, extended diffraction spikes generated by a dotted primary mirror are referenced against a wide-field grid of background stars to calibrate changing optical distortion and achieve microarcsecond astrometric precision on bright targets (Guyon et al. 2010). We describe applications of this concept to ground-based uncrowded astrometry using a diffractive, monopupil telescope and a wide-field camera to image as many as {approx}4000 background reference stars. Final relative astrometric precision is limited by differential tip/tilt jitter caused by high altitude layers of turbulence. A diffractive 3-meter telescope is capable of reaching {approx}35 {micro}as relative astrometric error per coordinate perpendicular to the zenith vector in three hours on a bright target star (I < 10) in fields of moderate stellar density ({approx}40 stars arcmin{sup -2} with I < 23). Smaller diffractive apertures (D < 1 m) can achieve 100-200 {micro}as performance with the same stellar density and exposure time and a large telescope (6.5-10 m) could achieve as low as 10 {micro}as, nearly an order of magnitude better than current space-based facilities. The diffractive pupil enables the use of larger fields of view through calibration of changing optical distortion as well as brighter target stars (V < 6) by preventing star saturation. Permitting the sky to naturally roll to average signals over many thousands of pixels can mitigate the effects of detector imperfections.

79 ASTRONOMY AND ASTROPHYSICS↗

The AWAKEN wind farm benchmark, Part 2: Modeling results

Accurately modeling wind farm performance in complex atmospheric flows remains a challenge. This paper presents the modeling results of the American WAKE experimeNt (AWAKEN) wind farm benchmark, a collaborative effort involving 16 research groups from academia and industry within the International Energy Agency Wind Technology Collaboration Programme Task 57. The study evaluates a diverse suite of simulation tools, ranging from fast-running engineering wake models to high-fidelity large-eddy simulations, against a diurnal case study observed during the AWAKEN campaign. The benchmark utilized a three-phase structure to progressively assess model performance as observational data availability increased. Initial blind predictions showed that higher-fidelity models did not uniformly outperform simpler simulation tools. A distinct spatial bias was observed where models struggled to resolve the interplay between a low-level jet, wakes, and terrain-induced flow acceleration. In subsequent phases, leveraging additional measurements for model improvement led to a reduction in mean absolute error across the model ensemble; however, this effect was most pronounced in engineering wake models, where targeted calibration reduced error by up to 40~\%. Overall, the study demonstrates that inflow characterization remains a primary prerequisite for accuracy, particularly for models relying on coarse forcing datasets. While the limited ability to resolve local terrain-flow interactions under single-day conditions represent a recognized constraint, the overall findings on wake modeling and real-world validation still provide valuable guidance for model application and for mitigating this limitation.

Bodini, Nicola↗

Image-based spectral distortion correction for photon-counting x-ray detectors

Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT). Methods: The polyenergetic incident spectrum was simulated with the tungsten anode spectral model using the interpolating polynomials (TASMIP) code and carefully calibrated to match the x-ray tube in this study. Experiments were performed on a Cadmium-Zinc-Telluride (CZT) photon-counting detector with five energy thresholds. Energy bins were adjusted to evenly distribute the recorded counts above the noise floor. BR12 phantoms of various thicknesses were used for calibration. A nonlinear function was selected to fit the count correlation between the simulated and the measured spectra in the calibration process. To evaluate the proposed spectral distortion correction method, an empirical fitting derived from the calibration process was applied on the raw images recorded for polymethyl methacrylate (PMMA) phantoms of 8.7, 48.8, and 100.0 mm. Both the corrected counts and the effective attenuation coefficient were compared to the simulated values for each of the five energy bins. The feasibility of applying the proposed method to quantitative material decomposition was tested using a dual-energy imaging technique with a three-material phantom that consisted of water, lipid, and protein. The performance of the spectral distortion correction method was quantified using the relative root-mean-square (RMS) error with respect to the expected values from simulations or areal analysis of the decomposition phantom. Results: The implementation of the proposed method reduced the relative RMS error of the output counts in the five energy bins with respect to the simulated incident counts from 23.0%, 33.0%, and 54.0% to 1.2%, 1.8%, and 7.7% for 8.7, 48.8, and 100.0 mm PMMA phantoms, respectively. The accuracy of the effective attenuation coefficient of PMMA estimate was also improved with the proposed spectral distortion correction. Finally, the relative RMS error of water, lipid, and protein decompositions in dual-energy imaging was significantly reduced from 53.4% to 6.8% after correction was applied. Conclusions: The study demonstrated that dramatic distortions in the recorded raw image yielded from a photon-counting detector could be expected, which presents great challenges for applying the quantitative material decomposition method in spectral CT. The proposed semi-empirical correction method can effectively reduce these errors caused by various artifacts, including pulse pileup and charge sharing effects. Furthermore, rather than detector-specific simulation packages, the method requires a relatively simple calibration process and knowledge about the incident spectrum. Therefore, it may be used as a generalized procedure for the spectral distortion correction of different photon-counting detectors in clinical breast CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Virtual Build: Low-Tech Simulations Can Be High on IPPD Content

After two years of design, component testing, and parts fabrication, the project team was within months of starting assembly on the first major elements of a new product assembly. Schedules were extremely tight and there was no room for error in the first unit build-up for test. The first draft of the assembly drawing was nearing completion and needed to be approved by key members of the Integrated Product Team (IPT) before release. Only then could the manufacturing planning be finalized and released for assembly to begin. What could we do to improve the quality of our first build effort? How could we minimize all the changes inherent in the first-time build of a complex mechanical system? Why not a dress rehearsal of the build process with all the participating players, hardware, and build documentation? A "virtual build simulation". In an organization employing integrated product teams there is no substitute for clear communication between the various cross-functional members. Despite team collocation, integrated solid modeling, and frequent coordination meetings. elements of the product-process design can still slip through the cracks and show up on the assembly floor. The virtual build exercise was designed to provide one intensive hands-on experience for all members of the design and assembly team in time to make corrections without schedule impact.

Hilscher, Rick↗

The Effects of Disturbance and Climate on Carbon Storage and the Exchanges of CO 2 Water Vapor and Energy Exchange of Evergreen Coniferous Forests in the Pacific Northwest: Integration of Eddy Flux, Plant and Soil Measurements at a Cluster of Supersites. Final report

This is the final technical report containing a summary of all findings with regard to the following objectives of the project: (1) To quantify and understand the effects of wildfire on carbon storage and the exchanges of energy, CO2, and water vapor in a chronosequence of ponderosa pine (disturbance gradient); (2) To investigate the effects of seasonal and interannual variation in climate on carbon storage and the exchanges of energy, CO2, and water vapor in mature conifer forests in two climate zones: mesic 40-yr old Douglas-fir and semi-arid 60-yr old ponderosa pine (climate gradient); (3) To reduce uncertainty in estimates of CO2 feedbacks to the atmosphere by providing an improved model formulation for existing biosphere-atmosphere models; and (4) To provide high quality data for AmeriFlux and the NACP on micrometeorology, meteorology, and biology of these systems. Objective (1): A study integrating satellite remote sensing, AmeriFlux data, and field surveys in a simulation modeling framework estimated that the pyrogenic carbon emissions, tree mortality, and net carbon exchange associated with four large wildfires that burned ~50,000 hectares in 2002-2003 were equivalent to 2.4% of Oregon statewide anthropogenic carbon emissions over the same two-year period. Most emissions were from the combustion of the forest floor and understory vegetation, and only about 1% of live tree mass was combusted on average. Objective (2): A study of multi-year flux records across a chronosequence of ponderosa pine forests yielded that the net carbon uptake is over three times greater at a mature pine forest compared with young pine. The larger leaf area and wetter and cooler soils of the mature forest mainly caused this effect. A study analyzing seven years of carbon and water dynamics showed that interannual and seasonal variability of net carbon exchange was primarily related to variability in growing season length, which was a linear function of plant-available soil moisture in spring and early summer. A multi-year drought (2001-2003) led to a significant reduction of net ecosystem exchange due to carry-over effects in soil moisture and carbohydrate reserves in plant-tissue. In the same forest, the interannual variability in the rate carbon is lost from the soil and forest floor is considerable and related to the variability in tree growth as much as it is to variability in soil climatic conditions. Objective (3): Flux data from the mature ponderosa pine site support a physical basis for filtering nighttime data with friction velocity above the canopy. An analysis of wind fields and heat transport in the subcanopy at the mesic 40-year old Douglas site yielded that the non-linear structure and behavior of spatial temperature gradients and the flow field require enhanced sensor networks to estimate advective fluxes in the subcanopy of forest to close the surface energy balance in forests. Reliable estimates for flux uncertainties are needed to improve model validation and data assimilation in process-based carbon models, inverse modeling studies and model-data synthesis, where the uncertainties may be as important as the fluxes themselves. An analysis of the time scale dependence of the random and flux sampling error yielded that the additional flux obtained by increasing the perturbation timescale beyond about 10 minutes is dominated by random sampling error, and therefore little confidence can be placed in its value. Artificial correlation between gross ecosystem productivity (GEP) and ecosystem respiration (Re) is a consequence of flux partitioning of eddy covariance flux data when GEP is computed as the difference between NEE and computed daytime Re (e.g. using nighttime Re extrapolated into daytime using soil or air temperatures). Tower-data must be adequately spatially averaged before comparison to gridded model output as the time variability of both is inherently different. The eddy-covariance data collected at the mature ponderosa pine site and the mesic Douglas fir site were used to develop and evaluate a new method to extract the signal of ecosystem respiration directly from daytime net ecosystem exchange. This approach may help reducing uncertainty in carbon budgets by providing direct measurements of ecosystem respiration during daylight conditions by replacing modeled estimates. Objective (4): We submitted our flux and biological and ancillary data to the AmeriFlux web site and to Fluxnet. This includes atmospheric carbon, water, and heat fluxes, soil fluxes, NPP, carbon stocks, LAI, and disturbance history. Fluxnet is updating the original La Thuile files and will include the more recent years of data. They will be using a new approach to compute GPP, following discussions within the network about the need to improve GPP methodology

54 ENVIRONMENTAL SCIENCES↗

An Assessment of Molten Metal Detachment Hazards During Electron Beam Welding in the Space Shuttle Bay at LEO for the International Space Welding Experiment

In 1997, the United States [NASA] and the Paton Electric Welding Institute are scheduled to cooperate in a flight demonstration on the U.S. Space Shuttle to demonstrate the feasibility of welding in space for a possible repair option for the International Space Station Alpha. This endeavor, known as the International Space Welding Experiment (ISWE), will involve astronauts performing various welding exercises such as brazing, cutting, welding, and coating using an electron beam space welding system that was developed by the E.O. Paton Electric Welding Institute (PWI), Kiev Ukraine. This electron beam welding system known as the "Universal Weld System" consists of hand tools capable of brazing, cutting, autogeneous welding, and coating using an 8 kV (8000 volts) electron beam. The electron beam hand tools have also been developed by the Paton Welding Institute with greater capabilities than the original hand tool, including filler wire feeding, to be used with the Universal Weld System on the U.S. Space Shuttle Bay as part of ISWE. The hand tool(s) known as the Ukrainian Universal Hand [Electron Beam Welding] Tool (UHT) will be utilized for the ISWE Space Shuttle flight welding exercises to perform welding on various metal alloy samples. A total of 61 metal alloy samples, which include 304 stainless steel, Ti-6AI-4V, 2219 aluminum, and 5456 aluminum alloys, have been provided by NASA for the ISWE electron beam welding exercises using the UHT. These samples were chosen to replicate both the U.S. and Russian module materials. The ISWE requires extravehicular activity (EVA) of two astronauts to perform the space shuttle electron beam welding operations of the 61 alloy samples. This study was undertaken to determine if a hazard could exist with ISWE during the electron beam welding exercises in the Space Shuttle Bay using the Ukrainian Universal Weld System with the UHT. The safety issue has been raised with regard to molten metal detachments as a result of several possible causes such as welder procedural error, externally applied impulsive forces(s), filler wire entrainment and snap-out, cutting expulsion, and puddle expulsion. Molten metal detachment from either the weld/cut substrate or weld wire could present harm to a astronaut in the space environment it the detachment was ti burn through the fabric of the astronaut Extravehicular Mobility Unit (EMC). In this paper an experimental test was performed in a 4 ft. x 4 ft. vacuum chamber at MSFC enabling protective garment to be exposed to the molten metal drop detachments to over 12 inches. The chamber was evacuated to vacuum levels of at least 1 x 10(exp -5) torr (50 micro-torr) during operation of the 1.0 kW Universal Hand Tool (UHT). The UHT was manually operated at the power mode appropriate for each material and thickness. The space suit protective welding garment, made of Teflon fabric (10 oz. per yard) with a plain weave, was placed on the floor of the vacuum chamber to catch the molten metal drop detachments. A pendulum release mechanism consisting of four hammers, each weighing approximately 3.65 lbs, was used to apply an impact forces to the weld sample/plate during both the electron beam welding and cutting exercises. Measurements were made of the horizontal fling distances of the detached molten metal drops. The volume of a molten metal drop can also be estimated from the size of the cut. Utilizing equations, calculations were made to determine chande in surafec area (Delat a(surface)) for 304 stainless steel for cutting based on measurements of metal drop sizes at the cut edges. For the cut sample of 304 stainless steel based on measurement of the drop size at the edge, Delta-a(surface) was determined to be 0.0054 2 in . Calculations have indicated only a small amount of energy is required to detach a liquid metal drop. For example, approximately only 0.000005 ft-lb of energy is necessary to detach a liquid metal steel drop based on the above theoretical analysis. However, some of the energy will be absorbed by the plate before it reaches the metal drop. Based on the theoretical calculations, it was determined that during a weld cutting exercise, the titanium alloy would be the most difficult to detach molten metal droplets followed by stainless steel and then by aluminum. The results of the experimental effort have shown that molten metal will detach if large enough of a hammer blow is applied to the weld sample plate during the full penetration welding and cutting exercises. However, no molten metal detachments occurred as a result of the filler wire snap-out tests from the weld puddle since it was too difficult to cause the metal to flick-out from the pool. Molten metal detachments, though not large in size, did result from the direct application of the electron beam on the end of the filler weld wire.

Fragomeni, James M.↗

Laboratory and On-Sky Validation of the Shaped Pupil Coronagraph's Sensitivity to Low-Order Aberrations with Active Wavefront Control

We present early laboratory simulations and extensive on-sky tests validating of the performance of a shaped pupil coronagraph (SPC) behind an extreme-AO (Adaptive Optics) corrected beam of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system. In tests with the SCExAO internal source/wavefront error simulator, the normalized intensity profile for the SPC degrades more slowly than for the Lyot coronagraph as low-order aberrations reduce the Strehl ratio (S.R.) from extremely high values (S.R. approximately 0.93-0.99) to those characteristic of current ground-based extreme AO systems (S.R. approximately 0.74-0.93) and then slightly lower values down to S.R. approximately 0.57. On-sky SCExAO data taken with the SPC and other coronagraphs for brown dwarf/planet-hosting stars HD 1160 and HR 8799 provide further evidence for the SPC's robustness to low-order aberrations. From H-band Strehl ratios of 80 percent to 70 percent, the Lyot coronagraph's performance versus that of the SPC may degrade even faster on sky than is seen in our internal source simulations. The 5-sigma contrast also degrades faster (by a factor of two) for the Lyot than the SPC. The SPC we use was designed as a technology demonstrator only, with a contrast floor, throughput, and outer working angle poorly matched for SCExAO's current AO performance and poorly tuned for imaging the HR 8799 planets. Nevertheless, we detect HR 8799 cde with SCExAO/CHARIS using the SPC in broadband mode, where the signal-to-noise ratio for planet e is within 30 percent of that obtained using the vortex coronagraph. The shaped-pupil coronagraph is a promising design demonstrated to be robust in the presence of low-order aberrations and may be well-suited for future ground and space-based direct imaging observations, especially those focused on follow-up exoplanet characterization and technology demonstration of deep contrast within well-defined regions of the image plane.

Currie, Thayne↗

Benchmark analytical solutions for steady state high frequency broadband sound fields in three rectangular enclosures

Analytical solutions are presented for broadband sound fields in three rectangular enclosures with absorption applied on the floor and ceiling, rigid sidewalls, and a vertically oriented dipole source. The solutions are intended to serve as benchmarks that can be used to assess the performance of broadband techniques, particularly energy-based methods, in a relatively straightforward configuration with precisely specified boundary conditions. A broadband Helmholtz solution is developed using a frequency-by-frequency modal approach to determine the exact band averaged mean-square pressures along spatial trajectories within each enclosure. Due to the specific choice of enclosure configuration and absorption distribution, an approximate specular solution can be obtained through a summation of uncorrelated image sources. Comparisons between the band averaged Helmholtz solution and the uncorrelated image solution reveal excellent agreement for a wide range of absorption levels and improve the understanding of correlation effects in broadband sound fields. In conclusion, a boundary element solution with diffuse boundaries is also presented, which produces consistently higher mean-square pressures in comparison with the specular solution, emphasizing the careful attention that must be placed on correctly modeling reflecting boundary conditions and demonstrating the errors that can result from assuming a Lambertian surface.

42 ENGINEERING↗

WIYN Open Cluster Study. LXIII. Abundances in the super-metal-rich open cluster NGC 6253 from hydra spectroscopy of the 7774 Å oxygen triplet region

We present a spectroscopic abundance analysis of the old, super-metal-rich open cluster NGC 6253, with emphasis on its O abundance. High-dispersion, 7774 Å O i triplet region spectra of 47 stars were obtained using Hydra II on the CTIO Blanco 4 m. Radial velocity analysis confirms 39 stars consistent with single star membership, primarily at the turnoff. Thirty-six of these are included in our abundance analysis. Our differential analysis relative to the Sun yields primarily scaled-solar values, with weighted cluster averages of [O/H] = +0.440 ± 0.020, [Fe/H] = +0.445 ± 0.014, [Al/H] = +0.487 ± 0.020, [Si/H] = +0.504 ± 0.018, and [Ni/H] = +0.702 ± 0.018 (where the errors are σ{sub μ}). We discuss possible origins for the three known super-metal-rich clusters based upon their abundance patterns, Galactic locations, and space motions. The abundance patterns of NGC 6253 are very similar to those of NGC 6791 and NGC 6583. With the possible exception of oxygen, the abundances of these clusters are all close to scaled-solar, and they are similar to patterns seen in metal-rich disk dwarfs and giants. However, they also seem to differ from those of metal-rich bulge stars. We demonstrate that NGC 6253 is unusually oxygen rich (in [O/H]) for its 3.3 Gyr age. While we find [O/Fe] to be scaled-solar for NGC 6253, the more recently reported values for NGC 6791 show a large variation, from values close to scaled-solar down to values at least a factor of two below scaled-solar. We discuss the possibility that the scaled-solar [O/Fe] abundances of NGC 6253 and NGC 6791 might reflect a flattening of the Galactic [O/Fe] versus [Fe/H] relationship. This possibility may be consistent with disk star abundance data, which show an apparent “floor” at [O/Fe] ∼−0.1 for [Fe/H] > 0, and with chemical evolution model results, which may predict such a flattening due to a decrease in supernova Fe yields at super-solar-metallicities. Orbit solutions for NGC 6791 allow that it may have formed in the inner disk and was then kicked out, but the origins of the other two much younger clusters remain mysterious. We re-evaluate the age of NGC 6583 in view of the evidence that the cluster is super-metal-rich, and confirm a probable age less than 1 Gyr (best range: 500–900 Myr). We also argue that it is unlikely the cluster is more than 3 kpc away (best range: 2–3 kpc) if the apparent turnoff, main sequence, and giants are all cluster members.

79 ASTRONOMY AND ASTROPHYSICS↗