Lightweight Long Life Heat Exchanger

A shuttle orbiter flight configuration aluminum heat exchanger was designed, fabricated, and tested. The heat exchanger utilized aluminum clad titanium composite parting sheets for protection against parting sheet pin hole corrosion. The heat exchanger, which is fully interchangeable with the shuttle condensing heat exchanger, includes slurpers (a means for removing condensed water from the downstream face of the heat exchanger), and both the core air passes and slurpers were hydrophilic coated to enhance wettability. The test program included performance tests which demonstrated the adequacy of the design and confirmed the predicted weight savings.

Moore, E. K.↗

Active heat exchange system development for latent heat thermal energy storage

Active heat exchange concepts for use with thermal energy storage systems in the temperature range of 250 C to 350 C, using the heat of fusion of molten salts for storing thermal energy are described. Salt mixtures that freeze and melt in appropriate ranges are identified and are evaluated for physico-chemical, economic, corrosive and safety characteristics. Eight active heat exchange concepts for heat transfer during solidification are conceived and conceptually designed for use with selected storage media. The concepts are analyzed for their scalability, maintenance, safety, technological development and costs. A model for estimating and scaling storage system costs is developed and is used for economic evaluation of salt mixtures and heat exchange concepts for a large scale application. The importance of comparing salts and heat exchange concepts on a total system cost basis, rather than the component cost basis alone, is pointed out. The heat exchange concepts were sized and compared for 6.5 MPa/281 C steam conditions and a 1000 MW(t) heat rate for six hours. A cost sensitivity analysis for other design conditions is also carried out.

Lefrois, R. T.↗

Charge-exchange plasma environment for an ion drive spacecraft

The charge exchange plasma environment around a spacecraft that uses mercury ion thrusters for propulsion is described. The interactions between the plasma environment and the spacecraft are determined and a model which describes the propagation of the mercury charge exchange plasma is discussed. The model is extended to describe the flow of the molybdenum component of the charge exchange plasma. The uncertainties in the models for various conditions are discussed and current drain to the solar array, charge exchange plasma material deposition, and the effects of space plasma on the charge exchange plasma propagation are addressed.

Kaufman, H. R.↗

Active heat exchange system development for latent heat thermal energy storage

Five tasks to select, design, fabricate, test and evaluate candidate active heat exchanger modules for future applications to solar and conventional utility power plants were discussed. Alternative mechanizations of active heat exchange concepts were analyzed for use with heat of fusion phase change materials (PCMs) in the temperature range of 250 to 350 C. Twenty-six heat exchange concepts were reviewed, and eight were selected for detailed assessment. Two candidates were selected for small-scale experimentation: a coated tube and shell heat exchanger and a direct contact reflux boiler. A dilute eutectic mixture of sodium nitrate and sodium hydroxide was selected as the PCM from over 50 candidate inorganic salt mixtures. Based on a salt screening process, eight major component salts were selected initially for further evaluation. The most attractive major components in the temperature range of 250 to 350 C appeared to be NaNO3, NaNO2, and NaOH. Sketches of the two active heat exchange concepts selected for test are given.

Lefrois, R. T.↗

Propagation of charge-exchange plasma produced by an ion thruster

A charge-exchange plasma is produced downstream of ion thrusters by collisions between energetic ions and neutrals escaping through the ion optics. The charge-exchange ions flow radially from the thruster beam due to electric fields produced by its density gradient. The propagation of the charge-exchange plasma after it leaves the thruster beam is the subject of this paper. Under the proper conditions there is an 'end-effect' of a long, cylindrical Langmuir probe which allows a significant increase in collected ion current when the probe is aligned with a flowing plasma. This effect is used to determine the charge-exchange plasma flow direction at various locations relative to the ion thruster. A portion of the charge-exchange plasma flows upstream of the ion thruster and can represent a contamination source to electrically propelled spacecraft. The ion current collected by the probe as a function of its angle with respect to the plasma flow allows determination of the plasma density and plasma flow velocity at the probe's location upstream of the ion thruster optics. The density value obtained from the ion current agree to within a factor of two of density values obtained by typical voltage-current Langmuir probe characteristics.

Carruth, M. R., Jr.↗

A review of studies on ion thruster beam and charge-exchange plasmas

Various experimental and analytical studies of the primary beam and charge-exchange plasmas of ion thrusters are reviewed. The history of plasma beam research is recounted, emphasizing experiments on beam neutralization, expansion of the beam, and determination of beam parameters such as electron temperature, plasma density, and plasma potential. The development of modern electron bombardment ion thrusters is treated, detailing experimental results. Studies on charge-exchange plasma are discussed, showing results such as the relationship between neutralizer emission current and plasma beam potential, ion energies as a function of neutralizer bias, charge-exchange ion current collected by an axially moving Faraday cup-RPA for 8-cm and 30-cm ion thrusters, beam density and potential data from a 15-cm ion thruster, and charge-exchange ion flow around a 30-cm thruster. A 20-cm thruster electrical configuration is depicted and facility effects are discussed. Finally, plasma modeling is covered in detail for plasma beam and charge-exchange plasma.

Carruth, M. R., Jr.↗

Direct contact droplet heat exchangers for thermal management in space

A liquid droplet heat exchanger for space applications is described which transfers heat between a gas and a liquid metal dispersed into droplets. The ability of the droplet heat exchanger to transfer heat between two media in direct contact over a wide temperature range circumvents many of the material limitations of conventional tube-type heat exchangers and does away with complicated plumbing systems and their tendency toward single point failure. Droplet heat exchangers offer large surface to volume ratios in a compact geometry, very low gas pressure drop, and high effectiveness. The application of the droplet heat exchanger in a high temperature Brayton cycle is discussed to illustrate its performance and operational characteristics.

Bruckner, A. P.↗

Neutral atomic oxygen beam produced by ion charge exchange for Low Earth Orbital (LEO) simulation

A low energy neutral atomic oxygen beam system was designed and is currently being assembled at the Lewis Research Center. The system utilizes a 15 cm diameter Kaufman ion source to produce positive oxygen ions which are charge exchange neutralized to produce low energy (variable from 5 to 150 eV) oxygen atoms at a flux simulating real time low Earth orbital conditions. An electromagnet is used to direct only the singly charged oxygen ions from the ion source into the charge exchange cell. A retarding potential grid is used to slow down the oxygen ions to desired energies prior to their charge exchange. Cryogenically cooled diatomic oxygen gas in the charge exchange cell is then used to transfer charge to the oxygen ions to produce a neutral atomic oxygen beam. Remaining non-charge exchanged oxygen ions are then swept from the beam by electromagnetic or electrostatic deflection depending upon the desired experiment configuration. The resulting neutral oxygen beam of 5 to 10 cm in diameter impinges upon target materials within a sample holder fixture that can also provide for simultaneous heating and UV exposure during the atomic oxygen bombardment.

Banks, Bruce↗

The design and fabrication of a Stirling engine heat exchanger module with an integral heat pipe

The conceptual design of a free-piston Stirling Space Engine (SSE) intended for space power applications has been generated. The engine was designed to produce 25 kW of electric power with heat supplied by a nuclear reactor. A novel heat exchanger module was designed to reduce the number of critical joints in the heat exchanger assembly while also incorporating a heat pipe as the link between the engine and the heat source. Two inexpensive verification tests are proposed. The SSE heat exchanger module is described and the operating conditions for the module are outlined. The design process of the heat exchanger modules, including the sodium heat pipe, is briefly described. Similarities between the proposed SSE heat exchanger modules and the LeRC test modules for two test engines are presented. The benefits and weaknesses of using a sodium heat pipe to transport heat to a Stirling engine are discussed. Similarly, the problems encountered when using a true heat pipe, as opposed to a more simple reflux boiler, are described. The instruments incorporated into the modules and the test program are also outlined.

Schreiber, Jeffrey G.↗

A piloted simulation study of data link ATC message exchange

Data link Air Traffic Control (ATC) and Air Traffic Service (ATS) message and data exchange offers the potential benefits of increased flight safety and efficiency by reducing communication errors and allowing more information to be transferred between aircraft and ground facilities. Digital communication also presents an opportunity to relieve the overloading of ATC radio frequencies which hampers message exchange during peak traffic hours in many busy terminal areas. A piloted simulation study to develop pilot factor guidelines and assess potential flight crew benefits and liabilities from using data link ATC message exchange was completed. The data link ATC message exchange concept, implemented on an existing navigation computer Control Display Unit (CDU) required maintaining a voice radio telephone link with an appropriate ATC facility. Flight crew comments, scanning behavior, and measurements of time spent in ATC communication activities for data link ATC message exchange were compared to similar measures for simulated conventional voice radio operations. The results show crew preference for the quieter flight deck environment and a perception of lower communication workload.

Waller, Marvin C.↗

The design and fabrication of a Stirling engine heat exchanger module with an integral heat pipe

The conceptual design of a free-piston Stirling Space Engine (SSE) intended for space power applications has been generated. The engine was designed to produce 25 kW of electric power with heat supplied by a nuclear reactor. A novel heat exchanger module was designed to reduce the number of critical joints in the heat exchanger assembly while also incorporating a heat pipe as the link between the engine and the heat source. Two inexpensive verification tests are proposed. The SSE heat exchanger module is described and the operating conditions for the module are outlined. The design process of the heat exchanger modules, including the sodium heat pipe, is briefly described. Similarities between the proposed SSE heat exchanger modules and the LeRC test modules for two test engines are presented. The benefits and weaknesses of using a sodium heat pipe to transport heat to a Stirling engine are discussed. Similarly, the problems encountered when using a true heat pipe, as opposed to a more simple reflux boiler, are described. The instruments incorporated into the modules and the test program are also outlined.

Schreiber, Jeffrey G.↗

A simulation study of data link message exchange - Flight deck perspective

Data link message exchange for Air Traffic Control (ATC) offers the potential of increasing flight safety and efficiency by reducing communication errors and enabling more information to be exchanged between aircraft and ground facilities. Digital communication also presents an opportunity to relieve the overloading of air traffic control radio frequencies, which hampers efficient message exchange during peak traffic periods in many busy terminal areas. A study has been completed at NASA Langley Research Center to compare the use of data link, for tactical ATC messages and ATIS reports, to conventional voice communication. The results indicate that flight crews prefer the data link message exchange for routine communication with air traffic control facilities. The data link communication process, however, entailed delays related to the physical characteristics of the link and the nature of the interface explored in this study. Consequently, the crews preferred voice radio when exchanging time critical messages.

Waller, Marvin C.↗

Multiphase complete exchange on a circuit switched hypercube

On a distributed memory parallel computer, the complete exchange (all-to-all personalized) communication pattern requires each of n processors to send a different block of data to each of the remaining n - 1 processors. This pattern is at the heart of many important algorithms, most notably the matrix transpose. For a circuit switched hypercube of dimension d(n = 2(sup d)), two algorithms for achieving complete exchange are known. These are (1) the Standard Exchange approach that employs d transmissions of size 2(sup d-1) blocks each and is useful for small block sizes, and (2) the Optimal Circuit Switched algorithm that employs 2(sup d) - 1 transmissions of 1 block each and is best for large block sizes. A unified multiphase algorithm is described that includes these two algorithms as special cases. The complete exchange on a hypercube of dimension d and block size m is achieved by carrying out k partial exchange on subcubes of dimension d(sub i) Sigma(sup k)(sub i=1) d(sub i) = d and effective block size m(sub i) = m2(sup d-di). When k = d and all d(sub i) = 1, this corresponds to algorithm (1) above. For the case of k = 1 and d(sub i) = d, this becomes the circuit switched algorithm (2). Changing the subcube dimensions d, varies the effective block size and permits a compromise between the data permutation and block transmission overhead of (1) and the startup overhead of (2). For a hypercube of dimension d, the number of possible combinations of subcubes is p(d), the number of partitions of the integer d. This is an exponential but very slowly growing function and it is feasible over these partitions to discover the best combination for a given message size. The approach was analyzed for, and implemented on, the Intel iPSC-860 circuit switched hypercube. Measurements show good agreement with predictions and demonstrate that the multiphase approach can substantially improve performance for block sizes in the 0 to 160 byte range. This range, which corresponds to 0 to 40 floating point numbers per processor, is commonly encountered in practical numeric applications. The multiphase technique is applicable to all circuit-switched hypercubes that use the common e-cube routing strategy.

Bokhari, Shahid H.↗

Concerted hydrogen atom exchange between three HF molecules

We have investigated the termolecular reaction involving concerted hydrogen exchange between three HF molecules, with particular emphasis on the effects of correlation at the various stationary points along the reaction. Using an extended basis, we have located the geometries of the stable hydrogen-bonded trimer, which is of C(sub 3h) symmetry, and the transition state for hydrogen exchange, which is of D(sub 3h) symmetry. The energies of the exchange reation were then evaluated at the correlated level, using a large atomic natural orbital basis and correlating all valence electrons. Several correlation treatments were used, namely, configration interaction with single and double excitations, coupled-pair functional, and coupled-cluster methods. We are thus able to measure the effect of accounting for size-extensivity. Zero-point corrections to the correlated level energetics were determined using analytic second derivative techniques at the SCF level. Our best calculations, which include the effects of connected triple excitations in the coupled-cluster procedure, indicate that the trimer is bound by 9 +/- 1 kcal/mol relative to three separate monomers, in excellent agreement with previous estimates. The barrier to concerted hydrogen exchange is 15 kcal/mol above the trimer, or only 4.7 kcal/mol above three separated monomers. Thus the barrier to hydrogen exchange between HF molecules via this termolecular process is very low.

Komornicki, Andrew↗

Test results of a Stirling engine utilizing heat exchanger modules with an integral heat pipe

The Heat Pipe Stirling Engine (HP-1000), a free-piston Stirling engine incorporating three heat exchanger modules, each having a sodium filled heat pipe, has been tested at the NASA-Lewis Research Center as part of the Civil Space Technology Initiative (CSTI). The heat exchanger modules were designed to reduce the number of potential flow leak paths in the heat exchanger assembly and incorporate a heat pipe as the link between the heat source and the engine. An existing RE-1000 free-piston Stirling engine was modified to operate using the heat exchanger modules. This paper describes heat exchanger module and engine performance during baseline testing. Condenser temperature profiles, brake power, and efficiency are presented and discussed.

Skupinski, Robert C.↗

Exchange, interpretation, and database-search of ion mobility spectra supported by data format JCAMP-DX

To assist peak assignment in ion mobility spectrometry it is important to have quality reference data. The reference collection should be stored in a database system which is capable of being searched using spectral or substance information. We propose to build such a database customized for ion mobility spectra. To start off with it is important to quickly reach a critical mass of data in the collection. We wish to obtain as many spectra combined with their IMS parameters as possible. Spectra suppliers will be rewarded for their participation with access to the database. To make the data exchange between users and system administration possible, it is important to define a file format specially made for the requirements of ion mobility spectra. The format should be computer readable and flexible enough for extensive comments to be included. In this document we propose a data exchange format, and we would like you to give comments on it. For the international data exchange it is important, to have a standard data exchange format. We propose to base the definition of this format on the JCAMP-DX protocol, which was developed for the exchange of infrared spectra. This standard made by the Joint Committee on Atomic and Molecular Physical Data is of a flexible design. The aim of this paper is to adopt JCAMP-DX to the special requirements of ion mobility spectra.

Baumback, J. I.↗

Characteristics of stratosphere-troposphere exchange in a general circulation model

In this study we examine mass exchange, water vapor exchange, and the behavior of idealized tracers and parcels to diagnose Stratosphere-Troposphere Exchange (STE) in the National Center for Atmospheric Research (NCAR) General Circulation Model (GCM), the Community Climate Model (CCM2). The CCM2 correctly represents the seasonality of mass exchange across 100 hPa, but values are uniformly too strong. Water vapor, however, indicates that tropical STE is not well represented in the CCM2; even though mean tropopause temperatures are colder than observed, the lower stratosphere is too moist. Most net mass flux occurs at water vapor mixing ratios of about 4-5 parts per million by volume (ppmv), about 1 ppmv too moist. Vertical resolution has little impact on the nature of tropical STE. In midlatitudes, CCM2 more successfully represents STE, which occurs in developing baroclinic waves and stationary anticyclones. Exchange from troposphere to stratosphere does occur but only influences the lowest few kilometers of the extratropical stratosphere, even for tracers with large vertical gradients.

Mote, Philip W.↗

Multiphase complete exchange on Paragon, SP2 and CS-2

The overhead of interprocessor communication is a major factor in limiting the performance of parallel computer systems. The complete exchange is the severest communication pattern in that it requires each processor to send a distinct message to every other processor. This pattern is at the heart of many important parallel applications. On hypercubes, multiphase complete exchange has been developed and shown to provide optimal performance over varying message sizes. Most commercial multicomputer systems do not have a hypercube interconnect. However, they use special purpose hardware and dedicated communication processors to achieve very high performance communication and can be made to emulate the hypercube quite well. Multiphase complete exchange has been implemented on three contemporary parallel architectures: the Intel Paragon, IBM SP2 and Meiko CS-2. The essential features of these machines are described and their basic interprocessor communication overheads are discussed. The performance of multiphase complete exchange is evaluated on each machine. It is shown that the theoretical ideas developed for hypercubes are also applicable in practice to these machines and that multiphase complete exchange can lead to major savings in execution time over traditional solutions.