Study of failure modes of multilevel large scale integrated circuits Interim scientific report, 15 Oct. 1967 - 14 Apr. 1968
Failure modes of large scale multilevel integrated microcircuit arrays
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Failure modes of large scale multilevel integrated microcircuit arrays
Electrical properties and failure modes of integrated multilevel microcircuits with silicon oxide-silicon interfaces
Purpose: To evaluate the curative effect of radio (chemo) therapy and mode of treatment failure in no-metastasis and lesion length ≤ 5.0cm esophageal squamous cell carcinoma (ESCC). Methods: There were 158 eligible patients were retrospectively analyzed, to analysis the curative effect of radio (chemo) therapy, prognosis factors, toxicity and prognostic index model. Results: To all patients the 1, 3, 5 overall survival rate were 83.54%, 52.53%, 32.58%, the local recurrence rate were 15.08%, 33.60% and 38.14%; distant metastasis rate were 10.64%, 25.21% and 36.06%; tumor specific survival rate were 76.64%, 54.07% and 44.51%. Multivariate analysis showed that patients with ECOG grade (χ2=13.945, P=0.000), short-term effect (χ2=19.360, P=0.000) and different radiotherapy methods (χ2=9.866, P=0.002) as the independent prognostic factors. Prognostic index model showed that the survival rate was significantly higher in the lower value of PI group than in the larger value of PI group (χ2=49.19, P=0.0000). In our whole group, there were simple locoregional recurrence (LR) 40 cases (25.3%), simple Distant metastasis (DM) 31 cases (19.6%), LR and DM in 14 cases (8.9%) after treatment. The chi-square test showed that there were no significant difference in the incidence of Elective Nodal Irradiation (ENI )and Involved Field Irradiation (IFI) patients with LR and DM ( χ2=2.363, 2.950, P=0.124, 0.085). Conclusion: Radio (chemo) therapy has a good curative effect in no-metastasis and lesion length ≤ 5.0cm ESCC patients.
Extensive research has been reported in the literature to characterize the failure mode of dry sand using various experimental techniques such as surface optical imaging, photo-elastic materials, three-dimensional (3D) computed tomography (CT), and 3D synchrotron micro-computed tomography (SMT). However, there is a limited literature about the behavior of saturated sand. This paper presents the results of axisymmetric triaxial compression (ATC) experiments that were conducted on saturated sand specimens. The behavior of specimens composed of a uniform sand with grain size between US sieves #40 and #50 is compared to specimens conducted on the same sand that has a wider gradation. 3D SMT technique was used to acquire 3D scans while shearing the specimens to probe localized events that are completely missed or misinterpreted when analyzing ATC measurements based on global standard measurements. The results show a higher effective principal stress ratio (EPSR) for the non-uniform specimen and a thicker shear band when compared to uniform specimen.
Photovoltaic plant owners and insurance companies would like to be prepared for the forthcoming material warranty claims (material defects) and power warranty claims (degradation rate). To address the needs of these stakeholders, this presentation aims to introduce a new conceptual approach to perform accelerated testing right at the field of interest and it is called field accelerated stress testing (FAST). The primary goal of this presentation is to present a conceptual approach to forecast the field specific failure modes and degradation rates in advance by a factor of 2 to 5, right at the plant site using a few spare modules available at the plant location itself.
The long-term stability for the hydrogen-evolution reaction (HER) of homojunction pn+-Ga0.52In0.48P photocathodes (band gap = 1.8 eV) with an electrodeposited Pt catalyst (pn+-GaInP/Pt) has been systematically evaluated in both acidic and alkaline electrolytes. Electrode dissolution during chronoamperometry was correlated with changes over time in the current density-potential (J-E) behavior to reveal the underlying failure mechanism. Pristine pn+-GaInP/Pt photocathodes yielded an open-circuit photopotential (Eoc) as positive as >1.0 V vs the potential of the reversible hydrogen electrode (RHE) and a light-limited current density (Jph) of >12 mA cm-2 (1-sun illumination). However, Eoc and Jph gradually degraded at either pH 0 or pH 14. The performance degradation was attributed to three different failure modes: (1) gradual thinning of the n+-emitter layer due to GaInP dissolution in acid; (2) active corrosion of the underlying GaAs substrate at positive potentials causing delamination of the upper GaInP epilayers; and (3) direct GaAs/electrolyte contact compromising the operational stability of the device. This work reveals the importance of both substrate stability and structural integrity of integrated photoelectrodes toward stable solar fuel generation.
Representations for margins associated with loss of assured safety (LOAS) for weak link (WL)/strong link (SL) systems involving multiple time-dependent failure modes are developed. The following topics are described: (i) defining properties for WLs and SLs, (ii) background on cumulative distribution functions (CDFs) for link failure time, link property value at link failure, and time at which LOAS occurs, (iii) CDFs for failure time margins defined by (time at which SL system fails) – (time at which WL system fails), (iv) CDFs for SL system property values at LOAS, (v) CDFs for WL/SL property value margins defined by (property value at which SL system fails) – (property value at which WL system fails), and (vi) CDFs for SL property value margins defined by (property value of failing SL at time of SL system failure) – (property value of this SL at time of WL system failure). Included in this presentation is a demonstration of a verification strategy based on defining and approximating the indicated margin results with (i) procedures based on formal integral representations and associated quadrature approximations and (ii) procedures based on algorithms for sampling-based approximations.
Methods, computer-readable media, and systems for automatically performing Human Factors Process Failure Modes and Effects Analysis for a process are provided. At least one task involved in a process is identified, where the task includes at least one human activity. The human activity is described using at least one verb. A human error potentially resulting from the human activity is automatically identified, the human error is related to the verb used in describing the task. A likelihood of occurrence, detection, and correction of the human error is identified. The severity of the effect of the human error is identified. The likelihood of occurrence, and the severity of the risk of potential harm is identified. The risk of potential harm is compared with a risk threshold to identify the appropriateness of corrective measures.
This paper describes a fault isolation approach for electric powertrains of unmanned aerial vehicles. The approach leverages the combination of failure mode and effect analysis (FMEA) and Bayesian networks, thus introducing depend-ability structures into a diagnostic framework. Faults and failure events from the FMEA are mapped within a Bayesian network, where network edges replicate the links embedded within FMEAs. This framework helps the fault isolation process by identifying the probability of occurrence of specific faults or root causes given evidence observed through sensor signals. The framework is applied to an electric power-train system of a small, rotary-wing unmanned aerial vehicle, demonstrating how a Bayesian network enhanced by FMEA helps disambiguate between root causes of incipient failures, which would otherwise be considered as equally probable.
Compressive failure mechanisms in quasi-isotropic graphite/epoxy laminates were characterized for both unnotched and notched specimens and also following damage by impact. Two types of fibers (Thornel 300 and 700) and four resin systems (Narmco 5208, American Cyanamid BP907, and Union Carbide 4901/MDA and 4901/mPDA) were studied. For all material combinations, failure of unnotched specimens was initiated by kinking of fibers in the 0-degree plies. A major difference was observed, however, in the mode of failure propagation after the 0-degree ply failure. The strength of quasi-isotropic laminates in general increased with increasing resin tensile modulus. The laminates made with Thornel 700 fibers exhibited slightly lower compressive strengths than did the laminates made with Thornel 300 fibers. The notch sensitivity as measured by the hole strength was lowest for the BP907 resin and highest for the 5208 resin. For the materials studied, however, the type of fiber had no effect on the notch sensitivity.
Compressive failure mechanisms in quasi-isotropic graphite/epoxy laminates were characterized for both unnotched and notched specimens and also following damage by impact. Two types of fibers (Thornel 300 and 700) and four resin systems (Narmco 5208, American Cyanamid BP907, and Union Carbide 4901/MDA and 4901/mPDA) were studied. For all material combinations, failure of unnotched specimens was initiated by kinking of fibers in the 0-degree plies. A major difference was observed, however, in the mode of failure propagation after the 0-degree ply failure. The strength of quasi-isotropic laminates in general increased with increasing resin tensile modulus. The laminates made with Thornel 700 fibers exhibited slightly lower compressive strengths than did the laminates made with Thornel 300 fibers. The notch sensitivity as measured by the hole strength was lowest for the BP907 resin and highest for the 5208 resin. For the materials studied, however, the type of fiber had no effect on the notch sensitivity.
A new method has been developed for assessment of the onset of degradation in solid state luminaires to classify failure mechanisms by using metrics beyond lumen degradation that are currently used for identification of failure. Luminous Flux output, Correlated Color Temperature Data on Philips LED Lamps has been gathered under 85°C/85%RH till lamp failure. The acquired data has been used in conjunction with Bayesian Probabilistic Models to identify luminaires with onset of degradation much prior to failure through identification of decision boundaries between lamps with accrued damage and lamps beyond the failure threshold in the feature space. In addition luminaires with different failure modes have been classified separately from healthy pristine luminaires. It is expected that, the new test technique will allow the development of failure distributions without testing till L70 life for the manifestation of failure.
Analysis data are presented on failed/defective silicon solar cell modules of various types and produced by different manufacturers. The failure mode (e.g., internal short and open circuits, output power degradation, isolation resistance degradation, etc.) are discussed in detail and in many cases related to the type of technology used in the manufacture of the modules; wherever applicable, appropriate corrective actions are recommended. Consideration is also given to some failure analysis techniques that are applicable to such modules, including X-ray radiography, capacitance measurement, cell shunt resistance measurement by the shadowing technique, steady-state illumination test station for module performance illumination, laser scanning techniques, and the SEM.
Printed circuit heat exchangers (PCHX) fabricated from high nickel alloys have shown promise as primary heat exchangers, recuperators, and solar receivers for high temperature and pressure supercritical carbon dioxide power cycles. There are numerous challenges in fabricating these devices including forming channel features, joining via diffusion or transient liquid phase bonding, and brazing/welding of headers. Commercial entities are understandably hesitant to share propriety best practices, and both commercial and non-commercial entities working on these components tend not to publically share failures and mistakes. However, sharing of this information could prevent similar costly errors and further the understanding of the coupled manufacturing, materials and mechanics issues in creating these components. Thus, in this paper, we document the challenges, failures, and mitigation methods uncovered in fabrication of prototype micro-pin based solar thermal receivers constructed of Haynes 230 and fabricated through a combination of photochemical machining (PCM), wire electrical discharge machining (EDM), transient liquid phase (TLP) bonding, vacuum brazing, and gas tungsten arc welding (GTAW). The receiver is designed to absorb concentrated solar fluxes greater than 140 W cm-2, while heating supercritical carbon dioxide from 550 °C to 720 °C at a pressure of 20 MPa to 25 MPa. The prototype receiver consists of a thin (~ 450 µm), Haynes 230 coversheet bonded to a 15 cm × 15 cm Haynes 230 micro-pin plate. The pieces are joined using a TLP bonding process with a nickel-phosphorus interlayer. Prior to bonding, micro-pins with height ~150 µm and diameter 300 µm are fabricated using PCM in the plate, and through slot features are made using wire EDM. Finally, flow headers are joined to the microchannel plate through a combination of vacuum brazing and GTAW. During hydrostatic proof testing, the prototype device failed when the coversheet delaminated from the pin array at a pressure of 290 bar. A failure analysis including scanning electron microscopy (SEM) to view failure sites and energy-dispersive X-ray spectroscopy (EDS) to evaluate elemental analysis of the failed areas was conducted. The failure modes can be broadly categorized as (1) failures potentially relating to reliquification of the transient liquid phase bonds between the micro-pins plate and coversheet during post-processing, (2) failures related to manufacturing defects, and (3) failures attributed to design.
Photovoltaic (PV) inverters are critical yet vulnerable components in modern energy systems, often acting as reliability bottlenecks that increase the levelized cost of energy (LCOE). To address this, this paper presents a comprehensive Failure Mode and Effects Analysis (FMEA) tailored for PV inverters. Leveraging field data and literature, we identify failure-prone components, such as capacitors,, and relays, and prioritize their risks based on quantitative Risk Priority Numbers (RPNs). The analysis reveals that surge-induced MOV short circuits, capacitor degradation, and environmental cooling fan failures dominate the risk profile. These findings provide a targeted framework for reliability improvement, guiding future efforts in predictive diagnostics, design optimization, and accelerated life testing strategies.
Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.
The recertification of the Space Shuttle Solid Rocket Booster (SRB) and Solid Rocket Motor (SRM) has included an extensive rewriting of the Failure Mode and Effects Analysis (FMEA) and Critical Items List (CIL). The evolution of the groundrules and methodology used in the analysis is discussed and compared to standard FMEA techniques. Especially highlighted are aspects of the FMEA/CIL which are unique to the analysis of an SRM. The criticality category definitions are presented and the rationale for assigning criticality is presented. The various data required by the CIL and contribution of this data to the retention rationale is also presented. As an example, the FMEA and CIL for the SRM nozzle assembly is discussed in detail. This highlights some of the difficulties associated with the analysis of a system with the unique mission requirements of the Space Shuttle.
The results of a failure analysis of finite width (+ or - theta)s T300/5208 graphite-epoxy laminates subjected to thermal curing loads and applied tensile strain are presented. Stress distributions obtained from linear elastic and linear thermoelastic finite element stress analyses are used in conjunction with the tensor polynomial failure criterion to predict the mode and location of first failure in laminates with fiber angles ranging from five to seventy-five degrees. It is shown that the mode of failure is predominantly interlaminar shear for small fiber angles, shifts to combined interlaminar normal, in-plane shear and in-plane normal for intermediate angles, and is primarily transverse tension for large fiber angles. The location of initial failure shifts from the (+ or - theta)s interface for small fiber angles to the midplane for large fiber angles.