Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Airfoil trailing edge flow measurements and comparison with theory, incorporating open wind tunnel corrections

Trailing edge data for boundary layer-near wake thickness parameters are given for airfoils and flat plates. Reynolds number effects are examined as a function of model size, velocity and boundary layer tripping. These data expand that presented previously by the authors particularly for airfoil non-zero angles of attack. Comparisons are made here with boundary layer calculations using potential flow modeling and a well documented two-dimensional finite-difference method for laminar and turbulent boundary layers. Open wind tunnel corrections to angle of attack and camber are developed and are incorporated in the potential flow modeling to assure correct comparisons for non-zero angles of attack. It was found that although the open tunnel flow turbulence affected boundary layer transition for the higher velocities the theory successfully 'brackets' the data. Comparisons demonstrate the degree of accuracy one might expect for the prediction of boundary layer thickness parameters when given only geometry and nominal flow conditions as input to boundary layer codes.

Brooks, T. F.↗

Ocular Blood Flow Measured Noninvasively in Zero Gravity

In spaceflight or a reduced-gravity environment, bodily fluids shift to the upper extremities of the body. The pressure inside the eye, or intraocular pressure, changes significantly. A significant number of astronauts report changes in visual acuity during orbital flight. To date this remains of unknown etiology. Could choroidal engorgement be the primary mechanism and a change in the curvature or shape of the cornea or lens be the secondary mechanism for this change in visual acuity? Perfused blood flow in the dense meshwork of capillaries of the choroidal tissue (see the preceding illustration) provides necessary nutrients to the outer layers of the retina (photoreceptors) to keep it healthy and maintain good vision. Unlike the vascular system, the choroid has no baroreceptors to autoregulate fluid shifts, so it can remain engorged, pushing the macula forward and causing a hyperopic (farsighted) shift of the eye. Experiments by researchers at the NASA Glenn Research Center could help answer this question and facilitate planning for long-duration missions. We are investigating the effects of zero gravity on the choroidal blood flow of volunteer subjects. This pilot project plans to determine if choroidal blood flow is autoregulated in a reduced-gravity environment.

Ansari, Rafat R.↗

Miniature probe for transonic flow direction measurements

A miniature probe is developed for measuring flow direction in one plane as well as stagnation pressure in the boundary layer and near wake of a transonic airfoil. The probe tip geometry and calibration curves are given, along with near wake survey data obtained for a supercritical airfoil. The advantages of the probe are ruggedness, ease of fabrication, ability to measure flow direction at a point, and insensitivity to out-of-plane velocity components.

Spaid, F. W.↗

Particle-fluid interactions for flow measurements

Study has been made of the motion of single particle and of group of particles, emphasizing solid particles in gaseous fluid. Velocities of fluid and particle are compared for several conditions of physical interest. Mean velocity and velocity fluctuations are calculated for single particle, and some consideration is given to multiparticle systems.

Berman, N. S.↗

Fluid dynamic studies on scattering aerosol and its generation for application as tracer particles in supersonic flow measurements utilizing laser Doppler velocimeter

An experimental study on the particle-fluid interactions of scattering aerosols was performed using monodisperse aerosols of different particle sizes for the application of laser Doppler velocimeters in subsonic turbulence measurements. Particle response was measured by subjecting the particles to an acoustically excited oscillatory fluid velocity field and by comparing the ratio of particle velocity amplitude to the fluid velocity amplitude as a function of particle size and the frequency of oscillation. Particle velocity was measured by using a differential laser Doppler velocimeter. The test aerosols were fairly monodisperse with a mean diameter that could be controlled over the size range from 0.1 to 1.0 micron. Experimental results on the generation of a fairly monodisperse aerosol of solid particles and liquid droplets and on the aerosol response in the frequency range 100 Hz to 100 kHz are presented. It is indicated that a unit density spherical scatterer of 0.3 micron-diameter would be an optimum choice as tracer particles for subsonic air turbulence measurements.

Mazumder, M. K.↗

Axial flow measurements in trailing vortices

A scanning laser Doppler velocimeter was used to measure the axial velocity defect in the cores of trailing vortices behind a lifting airfoil of rectangular planform. Data were obtained at several different angles of attack and downstream distances ranging from 30 to 1000 chord lengths. The test was designed to obtain continuous data from the near field into the far field while removing uncertainties associated with the interpretation of data obtained by the hydrogen bubble technique. The measured velocities of V sub x/U sub infinity are compared with those predicted. The agreement is remarkably good over the entire range of downstream distances, which supports the credibility of calculating axial velocities using the results of Moore and Saffman (1973).

Ciffone, D. L.↗

Temperature and flow measurements on near-freezing aviation fuels in a wing-tank model

Freezing behavior, pumpability, and temperature profiles for aviation turbine fuels were measured in a 190-liter tank chilled to simulate internal temperature gradients encountered in commercial airplane wing tanks. When the bulk of the fuel was above the specification freezing point, pumpout of the fuel removed all fuel except a layer adhering to the bottom chilled surfaces, and the unpumpable fraction depended on the fuel temperature near these surfaces. When the bulk of the fuel was at or below the freezing point, pumpout ceased when solids blocked the pump inlet, and the unpumpable fraction depended on the overall average temperature.

Friedman, R.↗

Temperature and flow measurements on near-freezing aviation fuels in a wing-tank model

Freezing behavior, pumpability, and temperature profiles for aviation turbine fuels were measured in a 190-liter tank, to simulate internal temperature gradients encountered in commercial airplane wing tanks. Two low-temperature situations were observed. Where the bulk of the fuel is above the specification freezing point, pumpout of the fuel removes all fuel except a layer adhering to the bottom chilled surfaces, and the unpumpable fraction depends on the fuel temperature near these surfaces. Where the bulk of the fuel is at or below the freezing point, pumpout ceases when solids block the pump inlet, and the unpumpable fraction depends on the overall average temperature.

Friedman, R.↗

Plasma flow measurements in a simulated low earth orbit plasma

The employment of large, higher power solar arrays for space operation has been considered, taking into account a utilization of high operating voltages. In connection with the consideration of such arrays, attention must be given to the fact that the ambient environment of space contains a tenuous low energy plasma which can interact with the high voltage array causing power 'leakage' and arcing. An investigation has been conducted with the aim to simulate the behavior of such an array in low-earth-orbit (LEO). During the experiments, local concentrations of the 'leakage' current were observed when the panel was at a high voltage. These concentrations could overload or damage a small area of cells in a large string. It was hypothesized that this effect was produced by electrostatic focusing of the particles by the sheath fields. To verify this experimentally, an end-effect Langmuir probe was employed. The obtained results are discussed.

Gabriel, S. B.↗

A comparison of electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry for flow measurements

Electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry are compared as methods for the accurate measurement of refractive index and density change distributions of phase objects. Experimental results are presented to show that the two methods have comparable accuracy for measuring the first derivative of the interferometric fringe shift. The phase object for the measurements is a large crystal of KD*P, whose refractive index distribution can be changed accurately and repeatably for the comparison. Although the refractive index change causes only about one interferometric fringe shift over the entire crystal, the derivative shows considerable detail for the comparison. As electronic phase measurement methods, both methods are very accurate and are intrinsically compatible with computer controlled readout and data processing. Heterodyne moire is relatively inexpensive and has high variable sensitivity. Heterodyne holographic interferometry is better developed, and can be used with poor quality optical access to the experiment.

Decker, A. J.↗

A comparison of electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry for flow measurements

Electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry are compared as methods for the accurate measurement of refractive index and density change distributions of phase objects. Experimental results are presented to show that the two methods have comparable accuracy for measuring the first derivative of the interferometric fringe shift. The phase object for the measurements is a large crystal of KD P, whose refractive index distribution can be changed accurately and repeatably for the comparison. Although the refractive index change causes only about one interferometric fringe shift over the entire crystal, the derivative shows considerable detail for the comparison. As electronic phase measurement methods, both methods are very accurate and are intrinsically compatible with computer controlled readout and data processing. Heterodyne moire is relatively inexpensive and has high variable sensitivity. Heterodyne holographic interferometry is better developed, and can be used with poor quality optical access to the experiment.

Decker, A. J.↗

Measuring Flow By Holographic Interferometry

Flow field reconstructed by computer-aided tomography. Holographic interferogram formed on photographic plate by interference between object and reference beams. Double-exposure interferograms taken with blade rotating and stationary at various positions processed to reconstruct mathematically airflow about model helicopter rotor blade.

Yu, Yung H.↗