At least 127 records · Page 7

Collection of fluorescence from an ion using trap-integrated photonics

Spontaneously emitted photons are entangled with the electronic and nuclear degrees of freedom of the emitting atom, so interference and measurement of these photons can entangle separate matter-based quantum systems as a resource for quantum information processing. Since confinement in a single-mode facilitates the photon interference needed for generating entanglement, the dipole emission patterns relevant in spontaneous emission present a mode-matching challenge. Current demonstrations rely on bulk photon-collection and manipulation optics that suffer from large component size and system-to-system variability—factors that impede scaling to the large numbers of entangled pairs needed for quantum information processing. To address these limitations, we demonstrate a collection method that enables passive phase stability, straightforward photonic manipulation, and intrinsic reproducibility. Specifically, we engineer a waveguide-integrated grating to couple photons emitted from a trapped ion into a single optical mode within a microfabricated ion-trap chip. Using the integrated collection optic, we characterize the collection efficiency, image the ion, and detect the ion’s quantum state. The integrated optic covers 2.18% of the solid angle and collects 1.97 ± 0.3% of the spontaneously emitted light incident on the grating for a total collection efficiency of 0.043% into a single-mode waveguide. This proof-of-principle demonstration lays the foundation for leveraging the inherent stability and reproducibility of integrated photonics to create, manipulate, and measure multipartite quantum states in arrays of quantum emitters.

Optical physics↗

Imaging and speciation of intracellular metallic implant debris using synchrotron-based X-ray fluorescence micro-spectroscopy: a study of two cases

Debris generated from total hip arthroplasty (THA) components made from metal alloys can cause, in some cases, inflammatory cell (e.g., macrophages) responses that lead to adverse local tissue reactions (ALTR) and implant failure. The lack of information on intracellular chemical alterations of metal debris has hindered the understanding of the pathogenesis of ALTR. The goal of this study was to characterize intracellular debris within macrophages using Synchrotron imaging and spectroscopy. We studied periprosthetic tissues of two retrieved THAs with (1) a metal-on-metal (MoM) articulation and (2) a metal-on-polyethylene (MoP) articulation exhibiting corrosion of the metal femoral head. The MoM-THA exhibited different valence states of chromium- and cobalt-containing debris, suggesting three different moieties: Cr 2 O 3 , CrPO 4 , and an alloy-oxide mixture. The findings further suggest that Cr 2 O 3 formed in the tribological interfaces of the implant, while CrPO 4 is a by-product of the phagocytosis process of cobalt alloy-containing debris. Titanium debris appeared to occur in a mixed crystalline/amorphous oxide state. It remains unclear if this chemical state results from the tribochemical processes at the implant surface or intracellular alterations. The MoP-THA specimen exhibited no intracellular particulate debris associated with macrohpages, indicating that the ALTR may be entirely triggered by metal ionic species in this case. A better understanding of in vivo chemical alteration of implant debris will aid in assessing the risk for ALTR during implant design and material choice. However, various techniques are needed to accurately determine the interaction between metal particles and the inta- and extra-cellular environment.

60 APPLIED LIFE SCIENCES↗

Acquisition of absorption and fluorescence spectral data using chatbots

Spectra – the lifeblood of photochemistry – have been very difficult to find in the literature. Chatbots, remarkably, may enable their more efficient acquisition and prove to be generally powerful tools for searching the scientific literature.

Taniguchi, Masahiko [Department of Chemistry, Nort↗

Fluorescence-mediated postcollision interaction in x-ray photoionization of the Xe 𝐾 edge

Postcollision interaction (PCI) in near-threshold photoionization of the K shell of atomic Xe is investigated with hard-x-ray synchrotron radiation. Applying Auger electron spectroscopy, line-shape distortion is monitored in the K-L 2 → L 2 M 4,5 M 4,5 decay channel, where the initial K-L 2 (Kα 2 ) x-ray-emission step mediates the emission of the two continuum electrons. The K-edge result is compared to similar data obtained on direct L 2 M 4,5 M 4,5 decay at the L 2 edge without x-ray-emission. In conclusion, it is found that the evolution of the PCI shift with excess photon energy is very similar at both edges, but a subtle decrease in the PCI shift is observable at the K edge due to the effect of the ultrafast x-ray emission step delaying the PCI energy exchange by a few attoseconds.

74 ATOMIC AND MOLECULAR PHYSICS↗

Calibration of hydrogen atoms measurement using femtosecond two-photon laser-induced fluorescence

What we believe to be a new calibration method for H-fs-TALIF is proposed, and the ratio of two-photon absorption cross-sections, σ (2) , for atomic hydrogen (H) and krypton (Kr) is determined using the broadband emission of a femtosecond laser system. The estimated ratio of the two-photon absorption cross-sections for H and Kr is σ (2) (Kr)/σ (2) (H) = 0.027 ± 20%, which is nearly twenty times lower than values previously obtained with narrowband nanosecond lasers. This discrepancy highlights the need for independent calibration of TALIF measurements for a specific laser pulsewidth range.

Starikovskiy, Andrey [Princeton Univ., NJ (United ↗

Optimizing ensemble NV − spin properties of fluorescent diamond microparticles by systematic low pressure high temperature annealing

Low pressure high temperature annealing is a means for driving nitrogen and defect diffusion in diamond to reduce internal lattice damage without the need for technically complicated high-pressure cells. Herein, we perform a systematic time (5, 15, and 30 min) and temperature (1200 °C–1800 °C) study of effects of low-pressure high temperature annealing on photoluminescence, spin concentrations, and spin relaxation properties of NV centers in ca. 3 μm synthetic type 1b diamond particles. Annealing in the temperature range of ca. 1400 °C–1700 °C for even 5 min leads to a higher optically detected magnetic resonance contrast as compared to standard annealing at 900 °C for 2 h. Particles annealed at 1700 °C for 5 min exhibit a contrast close to about 13% as compared to about 9% for those annealed at 900 °C for 2 h. A reduction in the zero-field splitting strain parameter from E ≈ 4.5 MHz to ≈ 2.5 MHz and spectral linewidth from Δν ≈ 7 MHz to ≈ 4 MHz are observed even after 5 min annealing at 1700 °C. Improvements in these spectral parameters resulted in a roughly 2-fold reduction in the noise level of temperature monitoring experiment utilizing an ensemble of NV centers in the particles. Annealing in the temperature range of 1600 °C for 15 or 30 min or 1700 °C for 5 min resulted in NV T 1 relaxation times approaching ca. 5 ms typically observed for bulk diamond. Quantitative electron paramagnetic resonance (EPR) allowed for estimations of thermal activation energies of paramagnetic center annihilation. Monitoring the primary defect concentration (P1 and other defects with half integer spins) and utilizing second order kinetic modeling, an activation energy of 3.63 ± 0.28 eV was estimated. Alternatively, using the NV half field EPR signal and first order kinetic modeling, a similar activation energy 3.89 ± 0.29 eV was estimated.