Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUORESCENT EMISSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurements of OH(X2pi) in the stratosphere by high resolution UV spectroscopy

This paper reports the first results obtained using high spectral resolution imaging ultraviolet spectroscopy to observe multiple rotational lines of OH A2 Sigma-X2pi (0-0) band. A 9.2 A spectral segment from 3075.8 A to 3085.0 A is imaged at 0.08 A FWHM spectral resolution, allowing the simultaneous acquisition of six of the brightest OH resonance fluorescence emission lines. The high spectral resolution and low scattered light design of the instrument allows these lines to be detected above the Rayleigh scattered sunlight background. The technique permits remote sensing of stratospheric OH from a high altitude instrument. The instrument was flown to an altitude of 40 km on Aug. 25, 1983, and again on June 12, 1986, on scientific balloons from Palestine, TX. The OH profiles inverted from the limb scans made during these flights are reported here. These profiles represent the first measurements of the temporal variation of OH over an extended height range. The results demonstrate that the technique can be used to monitor OH from orbit.

Torr, D. G.↗

Infrared investigation of water in Comet P/Halley

The results of the investigation of gaseous water, detected in the IR spectra of the Comet Halley's coma taken by the NASA's Kuiper Airborne Observatory, are summarized. High-resolution spectra revealed, near the wavelength of 2.65 microns, solar-pumped fluorescent emission in the (001-000) band of H2O and three lines of the (011-010) 'hot' band. The absolute production rate of H2O and its spatial distribution, temporal variability, and outflow velocity were measured along with the H2O ortho/para ratio. The measured line intensities indicate that water in the coma is rotationally relaxed. The aperture-averaged excitation temperatures for the low-lying rotational transitions were about 40 K, indicating that the coma kinetic temperature is extremely cold. Significant short-term temporal variations in the H2O line intensities were detected together with a strong pre- to postperihelion asymmetry (a factor of about 7) in the water production rate at a heliocentric distance of about 1 AU.

Weaver, H. A.↗

Photodissociation of pernitric acid (HO2NO2) at 248 nm

The photodissociation of pernitric acid (PNA) was studied at 248 nm. The quantum yield for production of OH radicals is 34 + or - 16 percent. The yield of OH from PNA was measured relative to that of H2O2. The translational and rotational energy content of the OH photofragment from PNA was characterized. A fluorescent emission was also observed and characterized. It is attributed to electronically excited NO2 produced in the PNA photodissociation. A maximum yield of 30 percent for NO2 production was determined. The intensity of this emission, and a mass spectrometric peak at m/e = 33, were found to be useful means of characterizing the purity of the PNA sample.

Macleod, Helene↗

Excited state absorption of pump radiation as a loss mechanism in solid-state lasers

The characteristics of optical pumping dynamics in laser-pumped, rare-earth-doped, solid-state laser materials are investigated by using a tunable alexandrite laser to pump Y3Al5O12:Nd(3+) in an optical cavity. It is found that the slope efficiency of the Nd laser operation depends strongly on the wavelength of the pump laser. For pump wavelengths resulting in low slope efficiencies, intense fluorescence emission is observed from the sample in the blue-green spectral region. This is attributed to the excited-state absorption of pump photons which occurs during radiationless relaxation from the pump band to the metastable state. This type of process is an important loss mechanism for monochromatic pumping of laser systems at specific pump wavelengths.

Kliewer, Michael L.↗

Limit on the CH4/CO ratio in Comet Levy (1990c) and comparisons with other comets

Near-infrared observations of comet Levy (1900c) were made on UT 4.3 and 5.3 Sep. 1990 from the United Kingdom Infrared Telescope on Mauna Kea. A scanning Fabry-Perot interferometer in combination with a cooled grating spectrometer was used to make a sensitive search for fluorescent emission from the v zub 3 band of CH4 near lambda approx. 3.3 microns. If CH4 is a parent molecule released directly from the nucleus, then the 3 sigma limit on its abundance is CH4/H2O approx. less than 0.0031, assuming that the kinetic temperature of the inner coma is approx. 50 K and that the CH4 spin species are equilibrated at a temperature approx. greater than 50 K. Since International Ultraviolet Explorer (IUE) observations of CO in Levy indicate that CO/H2O approx. 0.04 (Feldman et al.), researchers find that CH4/CO approx. less than 0.1. Infrared spectroscopic searches for CH4 in Comet Halley also yielded no positive detections; the more sensitive upper limit from the latter observations is CH4/H2O approx. less than 0.002. Since CO/H2O approx. 0.05 in Halley (not including the extended source of CO), the upper limits on the CH4/CO ratios are almost identical for comets Levy and Halley. A marginal infrared detection of the CH4 v sub 3 band in comet Wilson yielded CH4/H2O approx. 0.01 to 0.05 (Larson et al.), but there was no positive detection of CO. If the identification of the feature in the infrared spectrum of comet Wilson is correct, then that would indicate a very high CH4/CO ratio in this comet.

Weaver, Harold A.↗

The internal caustic structure of illuminated liquid droplets

The internal electric field of an illuminated liquid droplet is studied in detail using both wave theory and ray theory. The internal field obtains its maximum values on the caustics within the droplet. Ray theory is used to determine the equations of these caustics and the density of rays on them. The Debye series expansion of the interior field Mie amplitudes is used to calculate the wave theory version of these caustics. The physical interpretation of the sources of stimulated Raman scattering and fluorescence emission within a liquid droplet is then given.

Lock, James A.↗

A sensitive upper limit on the methane abundance in Comet Levy (1990c)

Results are presented on a ground-based search for fluorescent emission from CH4 at 3.3 microns in a newly discovered long-period comet, Comet Levy (1990c). It was found that the upper limit to the CH4 abundance in Comet Levy is similar to the Comet Halley CH4 abundance estimated from lower resolution IR spectra by Kawara et al. (1988). The Comet Levy CH4 abundance is significantly lower than the abundance derived by Larson et al. (1989) from a possible detection of CH4 in Comet Wilson.

Brooke, T. Y.↗

Self-absorption theory applied to rocket measurements of the nitric oxide (1, 0) gamma band in the daytime thermosphere

Observations of the UV fluorescent emissions of the NO (1, 0) and (0, 1) gamma bands in the lower-thermospheric dayglow, made with a sounding rocket launched on March 7, 1989 from Poker Flat, Alaska, were analyzed. The resonant (1, 0) gamma band was found to be attenuated below an altitude of about 120 km. A self-absorption model based on Holstein transmission functions was developed for the resonant (1, 0) gamma band under varying conditions of slant column density and temperature and was applied for the conditions of the rocket flight. The results of the model agreed with the measured attenuation of the band, indicating the necessity of including self-absorption theory in the analysis of satellite and rocket limb data of NO.

Eparvier, F. G.↗

The enigmatic object 2201 Oljato - Is it an asteroid or an evolved comet?

The orbital properties of near-earth object 2201 have been associated with meteor showers, and its modeled orbital evolution is chaotic - a property which might indicate a history related to comets. Telescopic observations of its visible and near-infrared spectral reflectance, broad-band visible and near-infrared photometry, infrared radiometric measurements, and radar echoes are reported here from two apparitions, 1979 and 1983. This asteroid has a high radiometric albedo, a property not associated with comet nuclei. In certain wavelength regimes it is classified as an S-type asteroid, in others, an E-type, but its overall spectral reflectance is not typical of either taxonomic type, and neither type is thought of as cometlike. Unexpectedly high ultraviolet reflectance at the 1979 apparition was suggested to be the result of residual outgassing as in a comet. The UV photometric data are modeled as fluorescent emission from neutral species found in comets. The resulting calculations indicate a plausible value for OH and CN emission at 0.3085 and 0.38 micron relative to the observed range of active comets.

Mcfadden, Lucy A.↗

CS band intensity and column densities and production rates of 15 comets

An accurate fluorescence efficiency of the CS(0,0) band and the lifetime of CS have been calculated at 1 AU heliocentric distance. Model-independent CS column densities and production rates are determined from derived fluorescent emission rates (g-factors) and lifetimes for 15 comets: Austin (1982g), Borrelly (1980i), Bradfield (1979X), Crommelin (1983n), Encke (1980), Encke (1984), Giacobini-Zinner (1984e), Halley (1982i), IRAS-Araki-Alcock (1983d), Meier (1980q), Panther (1980u), Stephan-Oterma (1980g), Tuttle (1980h), West (1975n), and Wilson (1986l).

Sanzovo, G. C.↗

Search for spatial variations of the H2O abundance in the lower atmosphere of Venus from NIMS-Galileo

The spectroscopic data of the Near-Infrared Mapping Spectrometer (NIMS), recorded during the Galileo flyby of Venus, are analysed to retrieve the water vapor abundance variations in the lower atmosphere of Venus at night. The 1.18 micrometer spectral window, which probes altitude levels below 20 km, is used for this purpose. Constraints on the CO2 continuum and far-wing opacity from existing ground-based high-resolution observations are included in the modelling of the NIMS spectra. The NIMS measurements can be fitted with a water vapor mixing ratio of 30 +/- 15 ppm, in agreement with analyses of ground-based nightside observations. The water vapor abundance shows no horizontal variations exceeding 20% over a wide latitude range (40 deg S, 50 deg N) on the nightside of Venus. Within the same selection of NIMS spectra, a large enhancement in the O2 fluorescence emission at 1.27 micrometer is observed at a latitude of 40 deg S, over a spatial area about 100 km wide.

Drossart, P.↗

Advances in Fluorescence Sensing Systems for the Remote Assessment of Nitrogen Supply in Field Corn

The studies described herein were conducted to better define changes in fluorescence properties of leaves from field grown corn (Zea mays L.) as they relate to varying levels of nitrogen (N) fertilization. This research was directed toward: 1) providing a remote non-destructive sensing technique to aid in the determination of optimal rates of N fertilization in corn crops and, 2) defining parameters for further development of fluorescence instrumentation to be operated remotely at field canopy levels. Fluorescence imaging bands centered in the blue (450 nm), green (525 nm), red (680 nm), and far-red (740 nm) and ratios of these bands were compared with the following plant parameters: rates of photosynthesis, N:C ratio, pigment concentrations, and grain yields. Both the fluorescence and physiological measures exhibited similar curvilinear responses to N fertilization level while significant linear correlations were obtained among fluorescence bands and band ratios to certain physiological measures of plant productivity. The red / blue, red / green, far-red / blue, far-red /green fluorescence ratios are well suited for remote observation and provided high correlations to grain yield, LAI, N:C, and chlorophyll contents. The results from this investigation indicate that fluorescence technology could aid in the determination of N fertilization requirements for corn. This discussion will also address design concepts and preliminary field trials of a mobile field-based Laser Induced Fluorescence Imaging System (LIFIS) capable of simultaneously acquiring images of four fluorescence emission bands from areas of plant canopies equaling 1 sq m and greater without interference of ambient solar radiation.

Corp, L. A.↗

Non-Intrusive Optical Diagnostic Methods for Flowfield Characterization

Non-intrusive optical diagnostic techniques such as Electron Beam Fluorescence (EBF), Laser-Induced Fluorescence (LIF), and Focusing Schlieren (FS) have been setup for high-speed flow characterization and large flowfield visualization, respectively. Fluorescence emission from the First Negative band of N2(+) with the (0,0) vibration transition (at lambda =391.44 nm) was obtained using the EBF technique and a quenching rate of N2(+)* molecules by argon gas was reported. A very high sensitivity FS system was built and applied in the High-Speed Flow Generator (HFG) at NASA LaRC. A LIF system is available at the Advanced Propulsion Laboratory (APL) on campus and a plume exhaust velocity measurement, measuring the Doppler shift from lambda = 728.7 nm of argon gas, is under way.

Tabibi, Bagher M.↗

Multispectral In-situ Measurements of Organic Matter and Chlorophyll Fluorescence in Seawater: Documenting the Intrusion of the Mississippi River Plume in the West Florida Shelf

We performed multispectral in-situ fluorescence measurement of colored dissolved organic matter and chlorophyll in surface water of the West Florida Shelf using West Labs Spectral absorption and Fluorescence Instrument (SAFIre). Continuous measurements underway allowed us to simultaneously map the dispersion of riverine organic material and chlorophyll on the shelf. By using two fluorescence emission ratios we were able to differentiate between riverine and marine CDOM. Our data also showed unusually high concentrations of CDOM offshore. These were attributed to an intrusion of the Mississippi River Plume. We performed limited comparisons between in-situ chlorophyll concentrations measured with SAFIre and chlorophyll values obtained from SeaWiFS satellite data using OC4 and MODIS algorithm. Our results show that, although both algorithms overestimated chlorophyll, MODIS performed better than OC4, particularly in areas with high CDOM concentrations. Analysis of the relationship between chlorophyll and CDOM concentrations within the study area showed regional variability causes by differences in river source.

DelCastillo, Carlos E.↗

Molecular Hydrogen in the Quiescent Disk of SW UMA

The FUSE observation has been reduced and a paper is in progress. The analysis has been slow because of the very noisy quality of the data. We anticipate submitting a paper in 2 or 3 months. The primary result is that there is no H_2 fluorescent emission. However, there seems to be no accretion disk. The upper limit to the continuum level is well below that observed by IUE, and while O VI lines are present, they are extremely faint and much narrower that the published and archival H alpha profiles. It appears that the accretion has essentially shut off entirely, leaving only very faint O VI and C III emission from the white dwarf. We are considering a magnetic model analogous to that for AE Aqr.

Raymond, John C.↗

A Compact Instrument for Remote Raman and Fluorescence Measurements to a Radial Distance of 100 m

Compact remote spectroscopic instruments that could provide detailed information about mineralogy, organic and biomaterials on a planetary surface over a relatively large area are desirable for NASA s planetary exploration program. Ability to explore a large area on the planetary surfaces as well as in impact craters from a fixed location of a rover or lander will enhance the probability of selecting target rocks of high scientific contents as well as desirable sites in search of organic compounds and biomarkers on Mars and other planetary bodies. We have developed a combined remote inelastic scattering (Raman) and laser-induced fluorescence emission (LIFE) compact instrument capable of providing accurate information about minerals, organic and biogenic materials to a radial distance of 100 m. Here we present the Raman and LIFE (R-LIFE) data set.

Sharma, S. K.↗

Use of UV Sources for Detection and Identification of Explosives

Measurement of Raman and native fluorescence emission using ultraviolet (UV) sources (<400 nm) on targeted materials is suitable for both sensitive detection and accurate identification of explosive materials. When the UV emission data are analyzed using a combination of Principal Component Analysis (PCA) and cluster analysis, chemicals and biological samples can be differentiated based on the geometric arrangement of molecules, the number of repeating aromatic rings, associated functional groups (nitrogen, sulfur, hydroxyl, and methyl), microbial life cycles (spores vs. vegetative cells), and the number of conjugated bonds. Explosive materials can be separated from one another as well as from a range of possible background materials, which includes microbes, car doors, motor oil, and fingerprints on car doors, etc. Many explosives are comprised of similar atomic constituents found in potential background samples such as fingerprint oils/skin, motor oil, and soil. This technique is sensitive to chemical bonds between the elements that lead to the discriminating separability between backgrounds and explosive materials.

Hug, William↗

Suzaku observation of IGR J16318-4848

We report on the first Suzaku observation of IGR J16318-4848, the most extreme example of a new group of highly absorbed X-ray binaries that have recently been discovered by the International Gamma-Ray Astrophysics Laboratory (INTEGRAL). The Suzaku observation was carried out between 2006 August 14 and 17, with a net exposure time of 97 ks. The average X-ray spectrum of the source can be well described (chi-square (sub red)= 0.99) with a continuum model typical for neutron stars i.e., a strongly absorbed power law continuum with a photon index of 0.676(42) and an exponential cutoff at 20.5(6) keY. The absorbing column is N(sub H) = 1.95(3) X 10(exp 24)/square cm. Consistent with earlier work, strong fluorescent emission lines of Fe K-alpha, Fe K-beta, and Ni K-alpha are observed. Despite the large N(sub H), no Compton shoulder is seen in the lines, arguing for a non-spherical and inhomogeneous absorber. Seen at an average 5-60 keV absorbed flux of 3.4 x 10(exp -10) erg/square cm/second, the source exhibits significant variability on timescales of hours.

Barragan, Laura↗