Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUOROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Percutaneous Radiofrequency Ablation of Osteoid Osteomas with Use of Real-Time Needle Guidance for Accurate Needle Placement: A Pilot Study

Purpose: To evaluate the accuracy and technical success of positioning a radiofrequency ablation (RFA) electrode in osteoid osteomas by use of a new real-time needle guidance technology combining cone-beam computed tomography (CT) and fluoroscopy. Materials and Methods: Percutaneous RFA of osteoid osteomas was performed in five patients (median age 18 years), under general anesthesia, with the use of cone-beam CT and fluoroscopic guidance for electrode positioning. The outcome parameters were technical success, meaning correct needle placement in the nidus; accuracy defined as the deviation (in mm) from the center of the nidus; and clinical outcome at follow-up. Results: In all five cases, positioning was possible within 3 mm of the determined target location (median nidus size 6.8 mm; range 5-10.2 mm). All procedures were technically successful. All patients were free of pain at clinical follow-up. No complications were observed. Conclusion: Real-time fluoroscopy needle guidance based on cone-beam CT is a useful tool to accurately position radiofrequency needles for minimally invasive treatment of osteoid osteomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Value of Duplex Ultrasound Assistance for Thromboaspiration and Dilation of Thrombosed Native Arterio-Venous Fistulae

Purpose: To evaluate the value of duplex ultrasound assistance during thromboaspiration of thrombosed arteriovenous fistulae for haemodialysis. Materials and Methods: We prospectively studied 54 thrombosed native fistulae (23 with total thrombosis and 31 with partial thrombosis), in which we performed manual thromboaspiration guided by ultrasonography associated with fluoroscopy. Results: The fistulae were located in the forearm (n = 39) or in the upper arm (n = 15) of 46 patients. Mean patient age was 65 years, and hypertension was the most common risk factor (74 %). Mean access age was 928 days (range 69-2,290), and most fistulae were on the left side (41 cases, 75.92 %). The success rate was 83 % in the total thrombosis group and 100 % in the partial thrombosis group. Including initial failures, the respective primary patency rates in the total thrombosis group and the partial thrombosis group were, respectively, 83 {+-} 8 % (n = 20) and 87 {+-} 6 % (n = 28) at 1 month, 39 {+-} 10 % (n = 10) and 61 {+-} 8 % (n = 20) at 6 months, and 17 {+-} 8 % (n = 5) and 26 {+-} 8 % (n = 9) at 1 year. The mean decrease of fluoroscopy time with ultrasound was 3 min (range 1-5). The mean decrease of radiation dose was 2.6 Gy cm Superscript-Two (range 0.9-4.3]. Conclusion: Ultrasound is a feasible and useful tool in the management of thrombosed native fistulae, thus decreasing radiation exposure, and has no detrimental effect on success rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality-of-Life Assessment After Palliative Interventions to Manage Malignant Ureteral Obstruction

Purpose:: Malignancies may cause urinary tract obstruction, which is often relieved with placement of a percutaneous nephrostomy tube, an internal double J nephro-ureteric stent (double J), or an internal external nephroureteral stent (NUS). We evaluated the affect of these palliative interventions on quality of life (QoL) using previously validated surveys. Methods:: Forty-six patients with malignancy related ureteral obstruction received nephrostomy tubes (n = 16), double J stents (n = 15), or NUS (n = 15) as determined by a multidisciplinary team. QoL surveys were administered at 7, 30, and 90 days after the palliative procedure to evaluate symptoms and physical, social, functional, and emotional well-being. Number of related procedures, fluoroscopy time, and complications were documented. Kruskal–Wallis and Friedman’s test were used to compare patients at 7, 30, and 90 days. Spearman’s rank correlation coefficient was used to assess correlations between clinical outcomes/symptoms and QoL. Results:: Responses to QoL surveys were not significantly different for patients receiving nephrostomies, double J stents, or NUS at 7, 30, or 90 days. At 30 and 90 days there were significantly higher reported urinary symptoms and pain in those receiving double J stents compared with nephrostomies (P = 0.0035 and P = 0.0189, respectively). Significantly greater fluoroscopy time was needed for double J stent–related procedures (P = 0.0054). Nephrostomy tubes were associated with more frequent minor complications requiring additional changes. Conclusion:: QoL was not significantly different. However, a greater incidence of pain in those receiving double J stents and more frequent tube changes in those with nephrostomy tubes should be considered when choosing palliative approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Exposure of Abdominal Cone Beam Computed Tomography

PurposeTo evaluate patients radiation exposure of abdominal C-arm cone beam computed tomography (CBCT).MethodsThis prospective study was approved by the institutional review board; written, informed consent was waived. Radiation exposure of abdominal CBCT was evaluated in 40 patients who underwent CBCT during endovascular interventions. Dose area product (DAP) of CBCT was documented and effective dose (ED) was estimated based on organ doses using dedicated Monte Carlo simulation software with consideration of X-ray field location and patients’ individual body weight and height. Weight-dependent ED per DAP conversion factors were calculated. CBCT radiation dose was compared to radiation dose of procedural fluoroscopy. CBCT dose-related risk for cancer was assessed.ResultsMean ED of abdominal CBCT was 4.3 mSv (95 % confidence interval [CI] 3.9; 4.8 mSv, range 1.1–7.4 mSv). ED was significantly higher in the upper than in the lower abdomen (p = 0.003) and increased with patients’ weight (r = 0.55, slope = 0.045 mSv/kg, p < 0.001). Radiation exposure of CBCT corresponded to the radiation exposure of on average 7.2 fluoroscopy minutes (95 % CI 5.5; 8.8 min) in the same region of interest. Lifetime risk of exposure related cancer death was 0.033 % or less depending on age and weight.ConclusionsMean ED of abdominal CBCT was 4.3 mSv depending on X-ray field location and body weight.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fusion Guidance in Endovascular Peripheral Artery Interventions: A Feasibility Study

PurposeThis study was designed to evaluate the feasibility of endovascular guidance by means of live fluoroscopy fusion with magnetic resonance angiography (MRA) and computed tomography angiography (CTA).MethodsFusion guidance was evaluated in 20 endovascular peripheral artery interventions in 17 patients. Fifteen patients had received preinterventional diagnostic MRA and two patients had undergone CTA. Time for fluoroscopy with MRA/CTA coregistration was recorded. Feasibility of fusion guidance was evaluated according to the following criteria: for every procedure the executing interventional radiologists recorded whether 3D road-mapping provided added value (yes vs. no) and whether PTA and/or stenting could be performed relying on the fusion road-map without need for diagnostic contrast-enhanced angiogram series (CEAS) (yes vs. no). Precision of the fusion road-map was evaluated by recording maximum differences between the position of the vasculature on the virtual CTA/MRA images and conventional angiography.ResultsAverage time needed for image coregistration was 5 ± 2 min. Three-dimensional road-map added value was experienced in 15 procedures in 12 patients. In half of the patients (8/17), intervention was performed relying on the fusion road-map only, without diagnostic CEAS. In two patients, MRA roadmap showed a false-positive lesion. Excluding three patients with inordinate movements, mean difference in position of vasculature on angiography and MRA/CTA road-map was 1.86 ± 0.95 mm, implying that approximately 95 % of differences were between 0 and 3.72 mm (2 ± 1.96 standard deviation).ConclusionsFluoroscopy with MRA/CTA fusion guidance for peripheral artery interventions is feasible. By reducing the number of CEAS, this technology may contribute to enhance procedural safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Occupational Radiation Exposure During Endovascular Aortic Repair

PurposeThe aim of the study was to evaluate the radiation exposure to operating room personnel and to assess determinants for high personal doses during endovascular aortic repair.Materials and MethodsOccupational radiation exposure was prospectively evaluated during 22 infra-renal aortic repair procedures (EVAR), 11 thoracic aortic repair procedures (TEVAR), and 11 fenestrated or branched aortic repair procedures (FEVAR). Real-time over-lead dosimeters attached to the left breast pocket measured personal doses for the first operators (FO) and second operators (SO), radiology technicians (RT), scrub nurses (SN), anesthesiologists (AN), and non-sterile nurses (NSN). Besides protective apron and thyroid collar, no additional radiation shielding was used. Procedural dose area product (DAP), iodinated contrast volume, fluoroscopy time, patient’s body weight, and C-arm angulation were documented.ResultsAverage procedural FO dose was significantly higher during FEVAR (0.34 ± 0.28 mSv) compared to EVAR (0.11 ± 0.21 mSv) and TEVAR (0.06 ± 0.05 mSv; p = 0.003). Average personnel doses were 0.17 ± 0.21 mSv (FO), 0.042 ± 0.045 mSv (SO), 0.019 ± 0.042 mSv (RT), 0.017 ± 0.031 mSv (SN), 0.006 ± 0.007 mSv (AN), and 0.004 ± 0.009 mSv (NSN). SO and AN doses were strongly correlated with FO dose (p = 0.003 and p < 0.001). There was a significant correlation between FO dose and procedural DAP (R = 0.69, p < 0.001), iodinated contrast volume (R = 0.67, p < 0.001) and left-anterior C-arm projections >60° (p = 0.02), and a weak correlation with fluoroscopy time (R = 0.40, p = 0.049).ConclusionAverage FO dose was a factor four higher than SO dose. Predictors for high personal doses are procedural DAP, iodinated contrast volume, and left-anterior C-arm projections greater than 60°.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization by Direct Puncture with a Transpedicular Approach Using an Isocenter Puncture (ISOP) Method in a Patient with a Type II Endoleak After Endovascular Aortic Repair (EVAR)

BackgroundEndovascular aortic repair (EVAR) requires further intervention in 20-30 % of cases, often due to type II endoleak (T2EL). Management options for T2EL include transarterial embolization, direct puncture (DP), or transcaval embolization. We report the case of an 80-year-old man with T2EL who successfully underwent DP embolization.MethodsEmbolization by DP was performed with a transpedicular approach using an isocenter puncture (ISOP) method. An isocenter marker (ICM) was placed at a site corresponding to the aneurysm sac on fluoroscopy in two directions (frontal and lateral views). A vertebroplasty needle was inserted tangentially to the ICM under fluoroscopy and advanced to the anterior wall of the vertebral body. A 20 cm-length, 20-G-PTCD needle was inserted through the outer needle of the 13-G needle and advanced to the ICM. Sac embolization using 25 % N-buty-2-cyanoacrylate diluted with Lipiodol was performed. After complete embolization, rotational DA confirmed good filling of the sac with Lipiodol. The outer cannula and 13-G needle were removed and the procedure was completed.ResultsThe patient was discharged the next day. Contrast-enhanced computed tomography 1 and 8 months later showed no Lipiodol washout in the aneurysm sac, no endoleak recurrence, and no expansion of the excluded aneurysm.ConclusionDP with a transpedicular approach using ISOP may be useful when translumbar and transabdominal approaches prove difficult.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase). During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Percutaneous Facet Screw Fixation in the Treatment of Symptomatic Recurrent Lumbar Facet Joint Cyst: A New Technique

We present a case of percutaneous treatment of symptomatic recurrent lumbar facet joint cyst resistant to all medical treatments including facet joint steroid injection. Percutaneous transfacet fixation was then performed at L4–L5 level with a cannulated screw using CT and fluoroscopy guidance. The procedure time was 30 min. Using the visual analog scale (VAS), pain decreased from 9.5, preoperatively, to 0 after the procedure. At 6-month follow-up, an asymptomatic cystic recurrence was observed, which further reduced at the 1-year follow-up. Pain remained stable (VAS at 0) during all follow-ups. CT- and fluoroscopy-guided percutaneous cyst rupture associated with facet screw fixation could be an alternative to surgery in patients suffering from a symptomatic recurrent lumbar facet joint cyst.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unenhanced Cone Beam Computed Tomography and Fusion Imaging in Direct Percutaneous Sac Injection for Treatment of Type II Endoleak: Technical Note

AimTo evaluate safety, feasibility, technical success, and clinical success of direct percutaneous sac injection (DPSI) for the treatment of type II endoleaks (T2EL) using anatomical landmarks on cone beam computed tomography (CBCT) and fusion imaging (FI).Materials and MethodsEight patients with T2EL were treated with DPSI using CBCT as imaging guidance. Anatomical landmarks on unenhanced CBCT were used for referencing T2EL location in the first five patients, while FI between unenhanced CBCT and pre-procedural computed tomography angiography (CTA) was used in the remaining three patients. Embolization was performed with thrombin, glue, and ethylene–vinyl alcohol copolymer. Technical and clinical success, iodinated contrast utilization, procedural time, fluoroscopy time, and mean radiation dose were registered.ResultsDPSI was technically successful in all patients: the needle was correctly positioned at the first attempt in six patients, while in two of the first five patients the needle was repositioned once. Neither minor nor major complications were registered. Average procedural time was 45 min and the average administered iodinated contrast was 13 ml. Mean radiation dose of the procedure was 60.43 Gy cm{sup 2} and mean fluoroscopy time was 18 min. Clinical success was achieved in all patients (mean follow-up of 36 months): no sign of T2EL was reported in seven patients until last CT follow-up, while it persisted in one patient with stability of sac diameter.ConclusionsDPSI using unenhanced CBCT and FI is feasible and provides the interventional radiologist with an accurate and safe alternative to endovascular treatment with limited iodinated contrast utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Associated with Advanced Inferior Vena Cava Filter Removals: A Single-Center Retrospective Study of 203 Patients Over 7 Years

PurposeTo identify factors associated with advanced inferior vena cava filter (IVCF) retrieval to raise awareness on technical considerations, retrieval efficiency, and patient safety.Materials and MethodsA single-center retrospective review was performed of 203 consecutive retrievable IVC filters placed between 2007 and 2014. Attempted retrievals were classified as advanced if the routine “snare and sheath” technique was initially unsuccessful after multiple attempts, or an alternate endovascular maneuver or access site was utilized. Patient and filter characteristics were recorded.Results203 attempted retrievals were reviewed (48.7 % male, 51.2 % female, mean age 52.7 years, mean dwell time 109 days). Advanced retrievals were observed in 20 patients (9.8 %) (15 females, 5 males). Fluoroscopy time (p ≤ 0.01, 34.3 ± 21.1 and 5.3 ± 4.5 min for advanced retrievals and routine retrievals respectively, same below), gender (p = 0.031), and retrieval tilt angle (p ≤ 0.01, 5.7 ± 5.10° vs. 11.9 ± 11.03°) were associated with advanced retrievals. Females were 3.16 times more likely to have an advanced retrieval performed than males with a significantly higher tilt angle in those with advanced retrieval. History of cancer (p = 0.502), dwell time (p = 0.916), retrieval caval diameter (p = 0.053), placement caval diameter (p = 0.365), filter type (p = 0.710), strut perforation (p = 0.506), placement tilt angle (p = 0.311), and age (p = 0.558) were not found significantly associated with advanced retrievals.ConclusionsWomen are at increased risk for advanced filter retrieval secondary to a significant change in filter tilt over time compared to men, independent of filter type or competing demographic or filter risks, likely placing them at increased risk for higher procedural fluoroscopy times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minilaparotomy-Assisted Transmesenteric-Transjugular Intrahepatic Portosystemic Shunt: Comparison with Conventional Transjugular Approach

PurposeThis study was performed to compare the intrahepatic shunt function outcome and procedural complications of minilaparotomy-assisted transmesenteric (MAT)-transjugular intrahepatic portosystemic shunt (TIPS) placement with the conventional transjugular method.MethodsThis is a retrospective review of all patients who had a MAT or conventional TIPS procedure over a 6-year period at our institute. The primary patency rate, fluoroscopy time, technical success, major procedure-related complications, and mortality data were compared between two treatment groups.ResultsWe included 49 patients with MAT-TIPS, and 63 with conventional TIPS, with an average follow-up of 21.43 months. The primary patency rates at 6 and 12 months were 82.9 and 66.7 % in the conventional TIPS group, and 81.0 and 76.5 % in the MAT-TIPS group (p = 1.000, and 0.529), respectively. There was no significant difference in technical success rate, post-procedure portosystemic pressure gradient, fluoroscopy time, and peri-procedural mortality rate between treatment groups. Major procedural-related complications were seen more frequently among MAT-TIPS patients (p = 0.012). In the MAT-TIPS group, 5 (10.2 %) patients developed post-procedure minilaparotomy, wound-related complications, and 5 (10.2 %) developed bacterial peritonitis; whereas, none of patients with conventional TIPS had either of these complications (p = 0.014).ConclusionWhile both MAT-TIPS and conventional TIPS had similar shunt primary patency rate and technical success rate, the MAT approach was associated with a significantly higher rate of minilaparotomy-related wound complications or infectious complications. These complications maybe prevented by a change in post-procedure monitoring and therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis

PurposeProstatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH.Materials and MethodsIRB-approved retrospective study of 40 consecutive patients 49–81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months.ResultsNo significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm{sup 2} vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred.ConclusionsRobotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Method of Adrenal Venous Sampling via an Antecubital Approach

PurposeCurrently, almost all adrenal venous sampling (AVS) procedures are performed by femoral vein access. The purpose of this study was to establish the technique of AVS via an antecubital approach and evaluate its safety and feasibility.Materials and MethodsFrom January 2012 to June 2015, 194 consecutive patients diagnosed as primary aldosteronism underwent AVS via an antecubital approach without ACTH simulation. Catheters used for bilateral adrenal cannulations were recorded. The success rate of bilateral adrenal sampling, operation time, fluoroscopy time, dosage of contrast, and incidence of complications were calculated.ResultsA 5F MPA1 catheter was first used to attempt right adrenal cannulation in all patients. Cannulation of the right adrenal vein was successfully performed in 164 (84.5%) patients. The 5F JR5, Cobra2, and TIG catheters were the ultimate catheters for right adrenal cannulation in 16 (8.2%), 5 (2.6%), and 9 (4.6%) patients, respectively. For left adrenal cannulation, JR5 and Cobra2 catheters were used in 19 (9.8%) and 10 (5.2%) patients, respectively, while only TIG catheters were used in the remaining 165 (85.1%) patients. The rate of successful adrenal sampling on the right, left, and bilateral sides was 91.8%, 93.3%, and 87.6%, respectively. The mean time of operation was (16.3 ± 4.3) minutes, mean fluoroscopy time was (4.7 ± 1.3) minutes, and the mean use of contrast was (14.3 ± 4.7) ml. The incidence of adrenal hematoma was 1.0%.ConclusionsThis study showed that AVS via an antecubital approach was safe and feasible, with a high rate of successful sampling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance is feasible and safe in roughly two-thirds of cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Usefulness of Virtual Fluoroscopic Preprocedural Planning During Percutaneous Transhepatic Biliary Drainage

Purpose To retrospectively evaluate the usefulness of virtual fluoroscopic preprocedural planning (VFPP) in the percutaneous transhepatic biliary drainage (PTBD) procedure.Materials and MethodsTwenty-two patients who were treated by PTBD were included in this study. Twelve patients were treated using PTBD intraoperative referencing coronal computed tomography (CT) images (i.e., coronal CT group), and ten patients were treated using PTBD intraoperative referencing VFPP images (i.e., VFPP group). To analyze the effect of the intraoperative referencing VFPP image, the VFPP group was retrospectively compared with the coronal CT group.ResultsThe characteristics of both patient groups were not statistically significantly different. There were no significant differences in the targeted bile duct, diameter and depth of the target bile, breath-holding ability, number of targeted bile duct puncture attempts, change in the targeted bile duct, and exchange of the drainage catheter. However, the X-ray fluoroscopy time and the procedure time were significantly shorter in the VFPP group than in the coronal CT group (196 vs. 334 s, P < 0.05; and 16.0 vs. 27.2 min, P < 0.05).ConclusionIntraoperative referencing using the VFPP imaging in PTBD intuitively can be a useful tool for better localization of the guidewire in the bile duct and thereby shorten the X-ray fluoroscopy time and procedure time while minimizing radiation exposure and complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BD and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transfemoral Venous Access Facilitates Upper Extremity Dialysis Interventions: Procedural Success and Clinical Outcomes

Purpose: To report technical success and clinical outcomes of transfemoral venous access for upper extremity dialysis interventions. Materials and Methods: A total of 15 patients underwent a transfemoral venous approach for fistulography (n = 4; 27%) or thrombectomy (n = 11; 73%) over a 14-month period. Access characteristics, sheath size, thrombectomy method, angioplasty site, fluoroscopy time, radiation dose, technical and clinical success, complications, and post-intervention primary and secondary patency rates were recorded. Results: Access type included arteriovenous fistulas (n = 10; 67%) and grafts (n = 5; 33%). The most common configuration was brachio-brachial (n = 6; 38%). Mean age of access was 37 months. Mean prior interventions were 4. Right CFV access was used in all patients using 6–8-French (most common: 7-French [n = 10; 67%]) sheaths. Most thrombectomies (n = 11; 73%) required both pharmacologic and mechanical maceration (n = 9; 82%). All accesses required angioplasty to treat underlying stenosis at the outflow vein (n = 12; 80%) or arteriovenous anastomosis (n = 9; 90%). Mean fluoroscopy time was 26.43 min. Air kerma and dose area product were 178.06 ± 225.77 mGy and 57,768.83 ± 87,553.29 μGym{sup 2}, respectively. Procedural and clinical success rates were 93% and 80%, respectively. Technical failure was due to persistent stenosis in one patient. Clinical failure was due to unsuccessful dialysis immediately following intervention in three patients. Mean post-intervention primary patency and secondary patency durations were 2.8 and 4.8 months, respectively. Primary patency rates at 1 and 3 months were 50% and 35%, respectively. Secondary patency rates at 1 and 3 months were 58% and 30%, respectively. Conclusion: A transfemoral venous approach for intervention of upper extremity dialysis accesses may be a valuable adjunct to traditional approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗