Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY SHIFT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Transportable Gravity Gradiometer Based on Atom Interferometry

A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.

Yu, Nan↗

Temperature Dependence of the Microwave Dielectric Behavior of Selected Materials

A very sensitive thermal bath is designed to study the effect of temperature on the microwave dielectric response of a sample of nickel oxide and cobalt oxide. The sample under study is placed in a microwave resonant cavity in the TE(sub 011) mode. The perturbations of the electric field are recorded in terms of the frequency shifts and the width changes of the microwave resonant signal as seen on the oscilloscope. The real and imaginary parts of the dielectric constant are calculated by using the values of the frequency shifts and width changes in the Slater's perturbation equations. The dielectric behavior of nickel oxide and cobalt oxide and also their mixture is studied at a microwave frequency of 9.2 GHz as a function of temperature. A computer program is written to analyze the dielectric constant values at different temperatures. The resonant cavity seems to be very sensitive in studying the dielectric relaxation mechanism in these materials. The dielectric behavior is also analyzed using Debye's equations, and relaxation times for these materials are calculated at microwave frequencies.

Dahiya, Jai N.↗

Method and apparatus for measuring frequency and phase difference

The present invention is a system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams are directed toward a target and corresponding beams returning therefrom are detected. A digital difference circuit forms a pulse train from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display are correlative to target position relative to beams.

Shores, Paul↗

Quartz Crystal Microbalance (QCM) monitor of contamination for LES-8/9

A Quartz Crystal Microbalance (QCM) was used to monitor condensable contamination during the launching of two Lincoln Laboratory Experimental Satellites--LES-8 and LES-9. The QCM was installed on the dispenser truss and measured contamination by means of a frequency shift of a quartz crystal oscillator. By using a special crystal cut and a second reference quartz crystal, the sensor had extreme sensitivity and remarkable temperature independence. A 1-Hz frequency shift, which corresponds to 3.5 x 10 to the -9th power g/sq cm was resolved by the flight instrumentation.

Lynch, J. T.↗

Method and apparatus for measuring frequency and phase difference

A system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams 152 and 152A are directed toward a target 153 and corresponding beams 154 and 154A returning therefrom are detected. A digital difference circuit 110 forms a pulse train 66 from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display 144 are correlative to target position relative to beams 152 and 152A.

Kobayashi, Herbert S.↗

Short-term changes in solar oscillation frequencies and solar activity

It is shown that the frequencies of solar rho-mode oscillations change significantly over periods as short as one month. These changes correlate significantly with variations in the strength of surface solar activity as measured by the average, over the sun's visible surface, of the magnitude of the line-of-sight magnetic field component from magnetograms. The frequency and mean magnetic variations are found to obey a linear relationship. It is seen that the mean frequency shift at any time depends on the history of solar activity over an interval of, at most, several months prior to the measurement and conclude that the dominant mechanism of the frequency shift is correlated with surface magnetic activity.

Woodard, M. F.↗

A Technique for Adjusting Eigenfrequencies of WGM Resonators

A simple technique has been devised for making small, permanent changes in the eigenfrequencies (resonance frequencies) of whispering-gallery-mode (WGM) dielectric optical resonators that have high values of the resonance quality factor (Q). The essence of the technique is to coat the resonator with a thin layer of a transparent polymer having an index of refraction close to that of the resonator material. Successive small frequency adjustments can be made by applying successive coats. The technique was demonstrated on a calcium fluoride resonator to which successive coats of a polymer were applied by use of a hand-made wooden brush. To prevent temperature- related frequency shifts that could interfere with the verification of the effectiveness of this technique, the temperature of the resonator was stabilized by means of a three-stage thermoelectric cooler. Measurements of the resonator spectrum showed the frequency shifts caused by the successive coating layers.

Strekalov, Dmitry↗

Method and System for Producing Images of an Object

A method and system are provided to produce images of an object. A receiving station is positioned in view of a range-coded signal emitting satellite and the object. The receiving station is sensitive to direct transmission of the range-coded signal and reflections of the range-coded signal from the object. Both range from the receiving station to the object and a Doppler frequency shift history between the receiving station and the object is determined using the direct transmission and reflections of the range-coded signal. An image is formed using the two-dimensional record provided by the range and the Doppler frequency shift history.

Katzberg, Stephen J.↗

Radiometric Spacecraft Tracking for Deep Space Navigation

Interplanetary spacecraft navigation relies on three types of terrestrial tracking observables.1) Ranging measures the distance between the observing site and the probe. 2) The line-of-sight velocity of the probe is inferred from Doppler-shift by measuring the frequency shift of the received signal with respect to the unshifted frequency. 3) Differential angular coordinates of the probe with respect to natural radio sources are nominally obtained via a differential delay technique of (Delta) DOR (Delta Differential One-way Ranging). The accuracy of spacecraft coordinate determination depends on the measurement uncertainties associated with each of these three techniques. We evaluate the corresponding sources of error and present a detailed error budget.

ranging↗

Detection of Non-Symmetrical Damage in Smart Plate-Like Structures

A two-dimensional model for in-plane vibrations of a cantilever plate with a non-symmetrical damage is used in the context of defect identification in materials with piezoelectric ceramic patches bonded to their surface. These patches can act both as actuators and sensors in a self-analyzing fashion, which is a characteristic of smart materials. A Galerkin method is used to approximate the dynamic response of these structures. The natural frequency shifts due to the damage are estimated numerically and compared to experimental data obtained from tests on cantilever aluminum plate-like structures damaged at different locations with defects of different depths. The damage location and extent are determined by an enhanced least square identification method. Efficacy of the frequency shift based algorithms is demonstrated using experimental data.

Blanks, H. T.↗

Ion cyclotron bands in VLF saucers

In the wideband VLF data obtained by the polar orbiting DE-1 satellite over the polar night ion trough region of the upper ionosphere, conspicuous frequency-band structures are found to occur both in absorption and emission, particularly associating with VLF saucers. The attenuation bands indicate that the ions of atomic hydrogen from the polar ionosphere are accelerated by the ac electric fields of VLF waves oscillating normal to the static magnetic field, analogous to a cyclotron accelerator. The observed frequencies of the cyclotron harmonics suggest that the acceleration is taking place in the layer below the satellite at a geocentric distance of less than about 1.5 earth radii. This example indicates the existence of upward propagating hiss at those altitudes inside the auroral zone. On the other hand, the frequency shifts of the emission bands are attributed to a combination of two different types of Doppler shift, one due to the orbital motion of the satellite and the other due to the upward motion of the medium at the emission source. This indicates the existence of an upward plasma flow at the source, with a velocity of the order of 20 km/s inside the saucer. The amount of this frequency shift decreases with increasing harmonic order, indicating a higher phase velocity for the electrostatic waves of higher harmonic order.

Maeda, Kaichi↗

RACE and Calculations of Three-dimensional Distributed Cavity Phase Shifts

The design for RACE, a Rb-clock flight experiment for the ISS, is described. The cold collision shift and multiple launching (juggling) have important implications for the design and the resulting clock accuracy and stability. We present and discuss the double clock design for RACE. This design reduces the noise contributions of the local oscillator and simplifies and enhances an accuracy evaluation of the clock. As we try to push beyond the current accuracies of clocks, new systematic errors become important. The best fountain clocks are using cylindrical TE(sub 011) microwave cavities. We recently pointed out that many atoms pass through a node of the standing wave microwave field in these cavities. Previous studies have shown potentially large frequency shifts for atoms passing through nodes in a TE(sub 013) cavity. The shift occurs because there is a small traveling wave component due to the absorption of the copper cavity walls. The small traveling wave component leads to position dependent phase shifts. To study these effects, we perform Finite Element calculations. Three-dimensional Finite Element calculations require significant computer resources. Here we show that the cylindrical boundary condition can be Fourier decomposed to a short series of two-dimensional problems. This dramatically reduces the time and memory required and we obtain (3D) phase distributions for a variety of cavities. With these results, we will be able to analyze this frequency shift in fountain and future space clocks.

Li, Ruoxin↗

Piezoelectric cantilever sensors

A piezoelectric cantilever with a non-piezoelectric, or piezoelectric tip useful as mass and viscosity sensors. The change in the cantilever mass can be accurately quantified by monitoring a resonance frequency shift of the cantilever. For bio-detection, antibodies or other specific receptors of target antigens may be immobilized on the cantilever surface, preferably on the non-piezoelectric tip. For chemical detection, high surface-area selective absorbent materials are coated on the cantilever tip. Binding of the target antigens or analytes to the cantilever surface increases the cantilever mass. Detection of target antigens or analytes is achieved by monitoring the cantilever's resonance frequency and determining the resonance frequency shift that is due to the mass of the adsorbed target antigens on the cantilever surface. The use of a piezoelectric unimorph cantilever allows both electrical actuation and electrical sensing. Incorporating a non-piezoelectric tip (14) enhances the sensitivity of the sensor. In addition, the piezoelectric cantilever can withstand damping in highly viscous liquids and can be used as a viscosity sensor in wide viscosity range.

Shih, Wan Y.↗

Future Laser-Cooled Microwave Clock Performance

Limitations to the performance of laser-cooled earth and space-based Cs clocks will be critically discussed. The most significant limitation to the stability and accuracy of laser-cooled atomic clocks is the frequency shift due to cold collisions. Because of it, laser-cooled Cs clocks must be operated at low density and this implies that space based Cs clock performance will not be significantly better than earth based. To regain some of the high accuracy and stability lost to the low density, clocks can be designed to multiply launch (or juggle) atoms. Clocks based on other atoms, in particular Rb-87 or possibly Rb-85, may have much smaller cold collision frequency shifts and therefore be capable of higher stability and accuracy, especially in a space environment.

Gibble, Kurt↗

DSP-based non-coherent dual detector demodulator for land mobile radio channels

This paper outlines the development of a digital demodulator suitable for the non-coherent detection of various modulation formats including: Phase Shift Keying (PSK), Continuous Phase Frequency Shift Keying (CPFSK) and Frequency Modulation (FM). The demodulator design concept has been derived with a view towards a single integrated circuit (IC) implementation. Two detectors, one non-coherent and one differentially coherent, operate concurrently, providing data detection and automatic frequency control (AFC). Bit error rate results are provided which illustrate the receiver performance in white Gaussian noise.

Saulnier, Gary J.↗

CW ultrasonic bolt tensioning monitor

A CW ultrasonic device is described for measuring frequency shifts of the peak of a mechanical resonance in a body. One application of the device is measuring the strain in a bolt, and other applications such as measuring the thickness of a body, measuring the depth of a flaw in a body, measuring the elongation of a body, and measuring changes in velocity of sound in a body. The body is connected, by means of a CW transducer, to electrical circuit means including a narrow band RF amplifier to form a closed loop feedback marginal oscillator that frequency locks the device to the peak of a mechanical resonance in the body. When the frequency of this peak changes, because of a physical change in the body, the frequency of the oscillator changes. The device includes an automatic frequency resonant peak tracker that produces a voltage that is related to a change in frequency of the oscillator. This voltage is applied to the RF amplifier to change the center of its frequency band to include the frequency of the peak and is a measure of the frequency shift.

Heyman, J. S.↗