Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Low-Rate Cycling Regeneration Sustains NMC811–Graphite Battery Performance through Extreme Ultrafast Charging

Urban air mobility (UAM) systems, such as electric vertical takeoff and landing (eVTOL) aircraft, require batteries capable of extreme ultrafast charging to support high-frequency operations. Here, in this work, we evaluate the electrochemical stability of NMC811–graphite full cells using a complex mixed-modal protocol designed to simulate the aggressive turnaround demands of UAM missions. We demonstrate that incorporating a periodic low-rate (0.3C) “regeneration” cycle enables cells to maintain 96% capacity retention over 900 cycles, despite repeated exposure to ultrafast pulses. To validate the efficacy of this regeneration mechanism, we performed simplified control experiments comparing continuous 10C charging against a 10C–0.3C interleaved protocol. Advanced characterization reveals that while mechanical particle fracture is pervasive at these rates, the regeneration cycles decelerate the electrochemical degradation by resolving spatially heterogeneous Ni oxidation states and relaxing lithium-ion concentration gradients. These findings provide a vital mechanistic framework for battery operation, proving that restorative charging can effectively delay and mitigate failure in demanding UAM applications.

batteries↗

A Self-Healing, Flowable, Yet Solid Electrolyte Suppresses Li-Metal Morphological Instabilities

In this article, lithium metal (Li 0 ) solid-state batteries encounter implementation challenges due to dendrite formation, side reactions, and movement of the electrode–electrolyte interface in cycling. Notably, voids and cracks formed during battery fabrication/operation are hot spots for failure. Here, a self-healing, flowable yet solid electrolyte composed of mobile ceramic crystals embedded in a reconfigurable polymer network is reported. This electrolyte can auto-repair voids and cracks through a two-step self-healing process that occurs at a fast rate of 5.6 µm h -1 . A dynamical phase diagram is generated, showing the material can switch between liquid and solid forms in response to external strain rates. The flowability of the electrolyte allows it to accommodate the electrode volume change during Li 0 stripping. Simultaneously, the electrolyte maintains a solid form with high tensile strength (0.28 MPa), facilitating the regulation of mossy Li 0 deposition. The chemistries and kinetics are studied by operando synchrotron X-ray and in situ transmission electron microscopy (TEM). Solid-state NMR reveals a dual-phase ion conduction pathway and rapid Li + diffusion through the stable polymer-ceramic interphase. This designed electrolyte exhibits extended cycling life in Li 0 –Li 0 cells, reaching 12 000 h at 0.2 mA cm -2 and 5000 h at 0.5 mA cm -2 . Furthermore, owing to its high critical current density of 9 mA cm -2 , the Li 0 –LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) full cell demonstrates stable cycling at 5 mA cm -2 for 1100 cycles, retaining 88% of its capacity, even under near-zero stack pressure conditions.

25 ENERGY STORAGE↗

Correlating aluminum layer deposition rates, Josephson junction microstructure, and superconducting qubits’ performance

An ultra-thin aluminum oxide layer is a key component for Josephson junctions (JJ) in superconducting quantum bits (qubits). This layer serves as a barrier layer for Cooper pairs tunneling between the superconducting electrodes and significantly influences the overall performance of the junction. In this study, we investigate the impact of aluminum deposition rates on the microstructure and chemical variation of the aluminum oxide layer, as well as the device's yields and qubits’ lifetimes. Surprisingly, although the oxide layer roughness and thickness variation improve noticeably with an increasing Al deposition rate from 0.5 Å/s to 5 Å/s, the qubit's coherence time is almost unchanged. We attribute this to the fact that Cooper pairs tunnel only through the thinnest region of the barrier. Additionally, we revealed a stress-induced grain boundary sliding short-circuit failure mechanism in the JJ. Our discovery provides a vital understanding of oxide microstructure and JJ functionality, which are critical for improving the coherence time of superconducting qubits.

Coherence time↗

Operational Parameter Database for Molten Salt Thermal Energy Storage Tank Modeling

The second generation of concentrated solar power (CSP) plants is characterized by the use of a central receiver (either cavity or external), two molten nitrate salt tanks (60 wt.% NaNO 3 and 40 wt.% KNO 3 ), and a steam Rankine power-generation cycle connected through a primary heat exchanger. Molten salt thermal energy storage (TES) tanks have been widely deployed in commercial CSP plants worldwide and have been essential for increasing plant dispatchability and capacity factor, while also reducing the levelized cost of electricity (LCOE). These systems enable energy storage at the gigawatt-hour scale, typically providing 6 to 17 hours of storage duration. Despite being a commercial technology, the multiple failures observed after only a few months or years of operation in plants around the world demonstrate the technology's relative infancy and highlight the need for further research to improve its reliability. The National Laboratory of the Rockies (NLR), in collaboration with industry partners and academic and research institutions, has been leading multiple projects funded by the U.S. Department of Energy (DOE). These projects focus on addressing molten salt tank failures by improving tank design and welding fabrication practices, evaluating new alloys and weld fillers, and providing guidelines for tank commissioning and safe operation. In particular, this report presents modeling results on the effect of key tank operation parameters during 60 minutes of operation, including the mass flow rate and temperature of the salt inflow, tank salt inventory temperature, and inventory level for a representative molten salt tank design. These results form a database of tank operation behaviors that captures the effects of each specific parameter during charging, charging/discharging, and discharging processes.

14 SOLAR ENERGY↗

Feasible Actuator Range Modifier (FARM), a Tool Aiding the Solution of Unit Dispatch Problems for Advanced Energy Systems

Integrated energy systems (IESs) seek to minimize power generating costs in future power grids through the coupling of different energy technologies. To accommodate fluctuations in load demand due to the penetration of renewable energy sources, flexible operation capabilities must be fully exploited, and even power plants that are traditionally considered as base-load units need to be operated according to unconventional paradigms. Thermomechanical loads induced by frequent power adjustments can accelerate the wear and tear. If a unit is flexibly operated without respecting limits on materials, the risk of failures of expensive components will eventually increase, nullifying the additional profits ensured by flexible operation. In addition to the bounds on power variations (explicit constraints),the solution of the unit dispatch problem needs to meet the limits on the variation of key process variables, including temperature, pressure and flow rate (implicit constraints).The FARM (Feasible Actuator Range Modifier) module was developed to enable existing optimization algorithms to identify solutions to the unit dispatch problem that are both economically favorable and technologically sustainable. Thanks to the iterative dispatcher–validator scheme, FARM permits addressing all the imposed constraints without excessively increasing the computational costs. In this work, the algorithms constituting the module are described, and the performance was assessed by solving the unit dispatch problem for an IES composed of three units, i.e., balance of plant, gas turbine, and high-temperature steam electrolysis. Finally, the FARM module provides dedicated tools for visualizing the response of the constrained variables of interest during operational transients and a tool aiding the operator at making decisions. These techniques might represent the first step towards the deployment of an ecological interface design (EID) for IES units.

47 OTHER INSTRUMENTATION↗

The effect of grain boundary yield and disconnections on grain boundary fracture strength

During high-temperature interfacial strain, e.g., creep or sintering, grain boundaries will sample non-equilibrium states associated with the non-equilibrium disconnections that mediate strain. This work tests the hypothesis that those non-equilibrium states should affect the mechanical properties of the grain boundary. High-temperature bicrystal tensile strain experiments performed on Sc-doped ZrO 2 as a function of strain rate enable the observation of fracture before and after grain boundary yield. Yielded boundaries exhibit a median fracture strength ≈ 50 % lower than those that did not yield. Molecular dynamics simulations performed on boundaries with and without interstitial-type disconnection loops indicate that the presence of those loops reduce the failure stress.

36 MATERIALS SCIENCE↗

Review of ECCS Acceptance Criteria and Experimental Basis Evolution Toward Fuel Fragmentation, Relocation, and Dispersal Studies

The U.S. nuclear industry is pursuing extensions of light water reactor (LWR) fuel burnup and enrichment limits to approximately 75 GWd/t and 10 wt.% 235 U to achieve economic and operational benefits. A central safety consideration in this effort is the behavior of high burnup (HBu) fuel during loss-of-coolant accidents (LOCAs), particularly fuel fragmentation, relocation, and dispersal (FFRD). Here, this work provides a historical and technical review of U.S. LOCA regulation and experimentation, clarifying how the evolution of Emergency Core Cooling System (ECCS) acceptance criteria in 10 CFR 50.46 has shaped both testing approaches and interpretations of fuel safety. The study revisits the original intent of the ECCS criteria, showing that the peak cladding temperature and equivalent cladding reacted limits were developed as surrogates to preserve a coolable geometry. The explicit inclusion of the coolable geometry criterion in the regulation was intended to emphasize the underlying safety philosophy and as a safeguard against unforeseen failure modes, an intent that remains directly relevant to modern concerns regarding FFRD. The review traces the lineage of HBu LOCA experiments to the Argonne National Laboratory furnace tests, from which subsequent programs at Studsvik, Halden, and Oak Ridge National Laboratory were derived. These tests employed a 5 °C/s heating rate inherited from early embrittlement studies, a stylized temperature history that does not represent actual LWR LOCA thermal-hydraulics. Comparison of these test conditions to pressurized water reactor large break LOCAs and separate effects data indicates that the existing HBu LOCA database may not be fully applicable to all LWR LOCA scenarios, from which a qualitative framework for applicability is proposed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY↗

Machine Learning for Predicting Multipactor Susceptibility in Planar RF Structures

Multipactor discharge is a persistent challenge in high-power microwave (HPM) and accelerator systems, where secondary electron avalanches can cause heating, vacuum degradation, and failure. This work presents the first supervised machine learning (ML) framework for multipactor prediction, trained on high-fidelity 3D Particle-in-Cell (PIC) simulation data in planar geometries. The model maps operational, geometric, and material-dependent secondary electron yield (SEY) parameters to the time-averaged electron growth rate, enabling rapid reconstruction of susceptibility charts. Among the models evaluated, tree-based ensemble methods such as Random Forest and Extra Trees demonstrate superior generalization to unseen materials compared to neural networks such as multilayer perceptron (MLP). Performance metrics, including Intersection over Union (IoU), Structural Similarity Index Measure (SSIM), and Pearson correlation, show close agreement with simulation benchmarks. Principal Component Analysis attributes generalization limits to material feature-space disjointedness.

43 PARTICLE ACCELERATORS↗

Development of Readily Available & Robust High Heat Flux Gardon Gauges

Concentrated solar power (CSP) technologies deliver concentrated solar energy as a heat source to industrial processes, power generation cycles, and chemical cycles. CSP systems require accurate and reliable high flux measurements, and next generation CSP systems will require flux measurement up to 1000 W/cm2. Existing flux measurement devices do not comprehensively meet the flux rating, cycle life, cost, and lead-time needs of stakeholders, necessitating the development of an improved flux sensor. In this study, Sandia National Laboratories (SNL) partnered with Hukseflux Thermal Sensors to develop a low-cost, short lead-time, and robust flux sensor rated to 250 W/cm2. Three prototype circular foil gauge designs were assessed for performance at the National Solar Thermal Test Facility (NSTTF) at SNL. Each gauge design measured flux up to 250 W/cm2 with <5% measurement error. Following baseline error quantification, gauges were exposed to flux above 500 W/cm2 to assess gauge failure mechanisms. Gauges physically survived >500 W/cm2 flux exposure, but measurement error was found to increase after foil coatings reached 400 °C. The results of this study suggest that coating optical properties change at excessive temperatures and that foil coating temperature, rather than heat flux level, dictates the acceptable gauge measurement range.

McLaughlin, Luke (ORCID:0000000303711310)↗

Thermal and electric field driven rf breakdown precursor formation on metal surfaces

The phenomenon of electric breakdown poses serious challenges to the design of devices that operate in high electric field environments. Experimental evidence points toward breakdown events that are accompanied by elevated temperatures and dark current spikes, which is attributed to high-asperity nanostructure formation that enhances the local electric field and triggers a runaway process. However, the exact mechanistic origin of such nanostructures under typical macroscopic operational conditions of electric field and magnetic-field-mediated heating remains poorly understood. In this work, we simulate the evolution of a copper surface under the combined action of the electric fields and elevated temperatures. Using a mesoscale curvature-driven surface evolution model, we show how a copper surface can undergo a type of dynamical instability that naturally leads to the formation of sharp asperities in realistic experimental conditions. Exploring the combined effect of fields and temperature rise, we identify the critical regimes that allow for the formation of breakdown precursors. The results show that thermoelastic stresses, while not essential, can significantly lower the critical electric field required for runaway surface instability, which is consistent with experimental observations that thermal effects can increase breakdown rates. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Toward Drilling the Perfect Geothermal Well: An International Research Coordination Network for Geothermal Drilling Optimization Supported by Deep Machine Learning and Cloud Based Data Aggregation

The EDGE project, supported by the U.S. Department of Energy Geothermal Technologies Office under award DE-EE0008793, established a data-driven framework for improving the efficiency, cost-effectiveness, and reliability of geothermal well drilling. The project focused on developing scalable data infrastructure, advanced machine learning and probabilistic models, and integrated analytics tools to support continuous drilling optimization. A central objective was to reduce geothermal drilling costs by up to seventy percent while minimizing the risk of well failure through predictive diagnostics and adaptive planning. Over the project period, a comprehensive data repository was designed and deployed, incorporating records from over one hundred geothermal wells across varied geological settings. This repository supported both structured and unstructured data and adhered to FAIR data principles, enabling provenance tracking, quality control, and standardized metadata. The project introduced automated ingestion pipelines and a cloud-hosted platform that facilitated access to raw, processed, and derived datasets. This infrastructure served as the foundation for model development and analysis. Machine learning workflows were developed to predict key drilling metrics including rate of penetration, non-productive time, and total drilling costs. Self-organizing maps and dimensionality reduction methods were used to uncover operational patterns and outliers, while supervised learning algorithms such as random forests and deep neural networks were applied to forecast performance outcomes. The models were validated on heterogeneous datasets from both U.S. and Icelandic fields, demonstrating variable but significant predictive accuracy. The results indicated that finer temporal resolution, inclusion of lithological data, and consistency in operational annotations could substantially improve model performance. The project also implemented process mining techniques to reconstruct state-transition models from drilling event logs. These models enabled the identification of deviations from optimal workflows and provided insights into recurring failure modes. Analysis of non-productive time highlighted the impact of equipment failures, geological challenges, and human factors, offering opportunities for targeted mitigation strategies. The EDGE Dashboard was developed as a web-based expert system integrating data visualization, model outputs, and user-driven queries. It provided an accessible interface for operators to explore historical data, evaluate predicted outcomes, and compare drilling scenarios. Initial feedback from project partners suggested that the dashboard could serve as a foundation for more advanced advisory and optimization tools. Overall, the EDGE project demonstrated the feasibility and value of applying modern data science techniques to geothermal drilling. It delivered a set of interoperable tools and models that can support more efficient, lower-risk well development. The findings point toward a viable path for transitioning from advisory analytics to semi-autonomous drilling systems, contingent on continued collaboration, expanded datasets, and field validation. The project results have immediate relevance for drilling operations, data management practices, and future geothermal R&D efforts aimed at achieving reliable, cost-competitive geothermal energy at scale.

15 GEOTHERMAL ENERGY↗

Random singlet-like state in the dimer-based triangular antiferromagnet Ba 6 Y 2 Rh 2 Ti 2 O 17 − δ

We present the magnetic, thermodynamic, and muon spin relaxation ( μ SR ) results of the dimer-based triangular antiferromagnet Ba 6 Y 2 Rh 2 Ti 2 O 17 − δ . The magnetic susceptibility data show the sub-Curie-Weiss behavior χ ( T ) ∝ T − α χ below 100 K, suggesting random magnetism. The isothermal magnetization results reveal the presence of weakly interacting structural orphan spins about 6.1 % at 2 K, arising from the oxygen deficiency. The comprehensive μ SR experiments exhibit the coexisting relaxing and nonrelaxing components along with the thermally activated behavior in the muon spin relaxation rate, reflecting the fluctuating orphan spins in the dimer singlet background. In addition, we observe the scaling behavior of M ( H , T ) in H / T and P z ( t ) in t / H LF with the scaling exponents α χ = α M = 0.75 and α μ = 0.72 , respectively, but not for the magnetic specific heat data. The failure of the scaling relation in C m ( H , T ) / T implies low-energy excitations dressed by the conventional orphan spins. Based on these observations, we find that the magnetic ground state resembles random singlets and discuss the possible configurations of the spin dimer unit Rh 2 O 9 . Our results shed light on the role of quenched disorder in the dimer-based frustrated magnets. Published by the American Physical Society 2024

Lee, Wonjun (ORCID:000000034848852X)↗

Cliff Retreat Rates Associated with a Low-Level Radioactive Waste Disposal Facility in Los Alamos, New Mexico, USA

We present an analysis and interpretation of potential cliff stability at a low-level waste disposal facility at Los Alamos National Laboratory, New Mexico, using cliff morphologic and fracture characteristics coupled with carbon-14 surface exposure dating. Our study is important as it directly bears on the licensing criteria for low-level radioactive waste sites. We find that future characteristic cliff failures will likely not breach disposal pits and shafts over the 1000-year minimum regulatory period. Further, we find, using a multivariate regression model, that slope angle and cliff face aspect are sub-equal in importance to predict regions of high risk of failure when combined with surface exposure ages and assuming that old exposure ages are most indicative of stability (instability) and therefore can aid decision making in final design implementation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Self‐Lubricating Tribo‐Catalytic Activity of 2D High Entropy Alloy Nanoflakes

High Entropy Alloys (HEAs) have garnered attention due to their remarkable tribological attributes. Predominantly, failure mechanisms in HEAs emanate from stress‐induced dislocations, culminating in crack propagation and film delamination. In this study, we report on the synthesis of 2D HEA of (MoWNbTaV) 0.2 S 2 which facilitates shear‐induced energy dissipation at sliding interfaces. The ball‐on‐disk tribological investigations demonstrate unprecedentedly low average coefficients of friction (0.076) and wear rates (10 −9 mm 3 (N∙m) −1 ) under high contact pressures (0.936 GPa) within ambient conditions. Employing multi‐scale characterizations alongside molecular dynamic simulations, we elucidate that the presence of the HEA triggers tribocatalytic activity under high contact pressures emerging as a pivotal factor in extending lubricant lifespan during tribological tests. The resilient lubriciousness coupled with the facile spray coating methodology of (MoWNbTaV) 0.2 S 2 in ambient environments paves the way for the development of a new class of solid lubricants based on 2D HEA.

2D solid lubricant↗

Coupled phase field damage and crystal plasticity analysis of intragranular fracture: The role of crystallographic orientation and voids

Damage evolution in engineering metal alloys at the grain scale exhibits significant microstructural heterogeneity and anisotropy. These heterogeneities create local hotspots for stress and strain localization, leading to void nucleation. Crystal orientation influences the active slip systems around voids, affecting lattice rotation and potentially forming discontinuities. At low triaxiality, voids may change shape due to lower stress, rotation, elongation, and coalescence. At high triaxiality, the correlation between crystal orientation and void growth rate becomes stronger, resembling the behavior observed in isolated single crystals. Therefore, understanding the effects of crystal orientation, heterogeneous strain, and defect evolution is crucial for single crystal fracture characterization. Here, in this work, a coupled phase-field damage (PFD) and crystal plasticity (CP) model is implemented within a finite element framework to analyze crystal deformation and failure. The CP method employs a dislocation density-based constitutive model, while intragranular failure is modeled using an anisotropic PFD method. The PFD model considers both the stored energy due to elastic stretching and the energy release due to defect formation and crack formation. A single crystal Al2219 with an intracrystalline spherical void is chosen to analyze fracture. The study finds that fracture propagation is strongly correlated with crystal orientations. This coupled CP-PFD model provides accurate failure prediction in crystalline materials by incorporating the effects of crystal orientations and existing voids. This study demonstrates how the local microstructure and defects influence plastic deformation and failure mechanisms in metal alloys.

Aluminum alloy↗

Experimental Methods for the Performance Test of Environment-Assisted Cracking (EAC) in Nuclear Industry and Examples through NSUF

Environmentally assisted cracking (EAC) is a critical failure mode in nuclear reactor environments, where materials are exposed to high temperatures, radiation, and corrosive media. Specific EAC studies in nuclear environments include stress corrosion cracking in primary water chemistry, irradiation-assisted stress corrosion cracking (IASCC) under neutron exposure, and hydrogen induced cracking (HIC) in reactor pressure vessels. The experimental methodologies of EAC include slow strain rate testing (SSRT), constant load, and cyclic loading techniques, conducted in autoclaves designed to simulate the reactor’s operational environments. This paper highlights several experimental case studies, especially on IASCC, conducted within the Nuclear Science User Facilities (NSUF).

36 - MATERIALS SCIENCE↗

Complex Dependence of Calcite Crack Kinetics on Salinity: The Role of DLVO and Hydration Forces

Abstract Subcritical crack growth (SCG) plays an important role in many geological processes such as delayed earth rupture and rock weathering. The complex dependency of SCG on the in‐crack fluid chemistry, however, is still poorly understood. In this study, we utilize the newly developed surface force‐based fracture theory (SFFT) to elucidate the relative contributions of surface forces and solute transport to the crack growth kinetics of calcite in NaCl solutions. Expanding on Barenblatt's cohesive crack model, SFFT introduces an effective stress intensity at the crack tip that encompasses all the relevant intermolecular forces across the crack in addition to the external far‐field stresses. The nonlinear system of equations portraying the crack opening profile, the solute distribution in a propagating crack, and the crack growth velocity are numerically solved via an implicit scheme. After carefully calibrating the model for calcite‐water systems, the SFFT is used to predict the SCG response of calcite at different NaCl concentrations, based on various hypotheses. These predictions are then compared to existing SCG data from the literature. We demonstrate that the experimentally observed variation of SCG rate with NaCl concentration cannot be explained solely by DLVO forces (electrostatic and Van der Waals interactions). This can be remediated by introducing an exponentially decaying hydration force with a nonlinear, nonmonotonic dependence on NaCl concentration. Furthermore, we demonstrate that accounting for both diffusive and advective transport of ions is important in explaining the absence of a stage‐II SCG response for calcite in electrolyte solutions. Plain Language Summary Subcritical crack growth (SCG) refers to the slow propagation of cracks in materials under a stress below the threshold for catastrophic failure. SCG is a key process in many geological events, for example, delayed earth ruptures and rock weathering. New initiatives such as underground CO 2 and H 2 storage in carbonate reservoirs further call for better understanding of SCG in carbonate minerals subjected to varying fluid chemistry. This study examines the SCG of calcite, a key mineral found in carbonate rocks, intergranular cement in sandstones, and filling material in mineral veins and faults, determining their deformation and strength. A mathematical model is developed to describe how the crack opens and propagates, how solutes (like salts) distribute within the crack, and how the crack surfaces interact with each other. We used the model to predict calcite SCG in water at different salt concentrations and compared it with experimental data. Our results revealed that the hydration force is the dominating factor in determining the complex, non‐linear dependency of SCG on salinity. We also found that both the movement of ions by diffusion and by bulk water flow are crucial for explaining the SCG rates, especially when the cracks grow quickly. Key Points Surface Force‐Based Fracture Theory predicts the complex subcritical crack growth patterns of calcite crystals immersed in NaCl solutions Results highlight the dominant role of hydration forces in altering the fracture behavior of calcite compared to VdW and electric double‐layer forces Advective solute transport explains the absence of stages‐II and ‐III subcritical crack growth responses in solid‐liquid systems

DLVO↗