Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fast Neutron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Identifying Neutron Irradiation in Space to Mitigate Bio-Medical Effects

Ubiquitous GCR high energy particles >1 GeV is primary concern • Medical effects compounded by ionizing dose of radiation from energetic particles- cancer, mutations, microbiome changes • Cancer induction and effects are irreversible after initiation • Long term space radiation exposure is cancer promoting but reversible Secondary GCR and Solar induced neutron spallation is a concern • Produced by interactions with space craft materials, EVA and planetary surfaces • Neutron Quality Factor is 10x that of beta, x-ray or gamma rays Space isn’t friendly to life or electronics! Real-time charged particle and EARLY neutron detection are required. Traveling fast or digging deep are the best protection. Nuclear space propulsion through LENR/LCF/Solid-State Fusion is a good bet!

space medicine↗

Low-cost, multi-mode detector solutions

Low-cost radiation detectors capable of providing efficient gamma-ray and neutron detection are essential in passive nuclear monitoring systems such as radiation portal monitors (RPMs) and detection of Special Nuclear Materials (SNM) through Active Interrogation (AI). Here, three low-cost detector solutions are discussed—(1) Large-area polystyrene-based plastic scintillators for AI (2) Pulse Shape Discrimination (PSD) capable plastic scintillators doped with heavy-metals for imparting gamma-ray spectroscopy (3) Composite detector technology based on inorganic scintillator submerged into the plastic scintillator, for detection of thermal and fast neutrons in addition to gamma-ray spectroscopy. Composite detectors using inorganic component such as Cs 2 LiYCl 6 (CLYC), Cs 2 LiLaBr x Cl 6-x (CLLBC), or CsI:Tl have been developed up to 4” sizes. Neutron and gamma efficiencies are compared for samples with different inorganic loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tagged fast neutron beams En > 6 MeV

Controlled flux of neutrons are produced through the {sup 14}N(d,n){sup 15}O nuclear reaction. Deuteron beams (2-4 MeV) are delivered by the CN-Van de Graaff accelerator and directed with full intensity to our Nitrogen target at SUGAR (SUpersonic GAs jet taRget). Each neutron is electronically tagged by the detection of the associated{sup 15}O. Its energy and direction are known and “beams” of fast monochromatic tagged neutrons (E{sub n}> 6 MeV) are available for basic research and applied work. MONDE is a large area (158 × 63 cm{sup 2}) plastic scintillating slab (5 cm thick), viewed by 16 PMTs from the sides. Fast neutrons (MeV) entering the detector will produce a recoiling proton that induces a light spark at the spot. Signals from the 16 detectors are processed to deduce the position of the spark. Time logic signals from both the {sup 15}O detector and MONDE are combined to deduce a time of flight (TOF) signal. Finally, the position information together with the TOF yields the full momentum vector of each detected neutron.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Spectroscopy

Neutron detection provides an effective method to detect, locate, and characterize sources of interest to nuclear security applications. Current neutron imaging systems based on double-scatter kinematic reconstruction provide good signal vs. background discrimination and spectral capability, but suffer from poor sensitivity due to geometrical constraints. This weakness can be overcome if both neutron-proton scattering interactions are detected and resolved within one large contiguous active detector volume. We describe here a maximum likelihood approach to event reconstruction in a single-volume system with no optical segmentation and sensitivity to individual optical photons on the surfaces of the scintillator. We present results from a Geant4-based simulation establishing the feasibility of this single-volume neutron scatter camera concept given notional performance of existing photodetector and readout technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection sensitivities in 3-8 MeV neutron activation

Study of detection sensitivities of 73 radioactive elements using fast unmoderated neutrons includes experiments for irradiation, cooling and counting conditions. The gamma ray emission spectra is used to identify the unknown material.

Wahlgren, M. A.↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Source Characterization. Year 2 of 3 Summary

The neutron scatter camera (NSC), an imaging spectrometer for fission energy neutrons, is an established and proven detector for nuclear security applications such as weak source detection of special nuclear material (SNM), arms control treaty verification, and emergency response. Relative to competing technologies such as coded aperture imaging, time-encoded imaging, neutron time projection chamber, and various thermal neutron imagers, the NSC provides excellent event-by-event directional information for signal/background discrimination, reasonable imaging resolution, and good energy resolution. Its primary drawback is very low detection efficiency due to the requirement for neutron elastic scatters in two detector cells. We will develop a singlevolume double-scatter neutron imager, in which both neutron scatters can occur in the same large active volume. If successful, the efficiency will be dramatically increased over the current NSC cell-based geometry. If the detection efficiency approaches that of e.g. coded aperture imaging, the other inherent advantages of double-scatter imaging would make it the most attractive fast neutron detector for a wide range of security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron-Friendly Li-Ion Battery Coin Cell for In Situ 3D Visualization of Li Plating

Advanced battery characterization using in situ/operando neutron imaging is critical for uncovering degradation modes such as lithium (Li) plating in Li-ion batteries (LIBs). However, conventional LIBs hinder operando neutron radiography (NR) and in situ neutron micro-computed tomography (N-μCT) for visualizing Li plating near the graphite-separator interface due to strong attenuation from hydrogen-rich components like PP–PE–PP separators, electrolyte, and Fe-based spacers. In this work, we designed and tested a neutron-friendly battery (NFB) optimized for in situ Li detection during extreme fast charging (XFC). Guided by neutron attenuation cross-sections and material transmission, the NFB enables clear visualization at the graphite–separator interface, which is typically opaque in standard LIBs. Electrochemical tests show the NFB exhibits voltage/current responses like standard cells for up to 50 XFC cycles. However, its lower reversibility and capacity are likely due to Cu-coated Al spacer degradation from delamination or corrosion. We propose titanium spacers as a more stable alternative, albeit requiring custom machining. Using this optimized cell, we achieved simultaneous neutron tomography of multiple cells, capturing in situ 3D images of dead Li accumulation, particularly near graphite edges. These heterogeneous deposits and disconnected Li clusters suggest localized current density hotspots during XFC.

25 ENERGY STORAGE↗

FY2024 Mid-Year Report: Verification of Spent Fuel Inside Dry Storage Casks by Cask Top Fast Neutron Mapping

This project is developing a prototype scanner array verification system for detection of missing fuel assemblies in spent-fuel storage casks. The prototype consists of six fast-neutron scintillator detectors mounted to a linear actuator frame that is placed on the top of a spent fuel cask to scan across all fuel assembly positions. The scanner array was assembled and tested at LLNL in prior years. A field test schedule has been requested at the Idaho National Laboratory (INL) Cask Farm site for FY2024. Following the Field Test, we will present results and discuss the technology with the IAEA. The IAEA may have special requirements for portability, shipping, lifting, and installation. We will incorporate additional improvements to the system based on lessons learned from the Field Test and feedback from the IAEA. If successful, the technology can be transferred to the IAEA or other stakeholders for assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

System and plastic scintillator for discrimination of thermal neutron, fast neutron, and gamma radiation

A scintillator material according to one embodiment includes a polymer matrix; a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount of 3 wt % or more; and at least one component in the polymer matrix, the component being selected from a group consisting of B, Li, Gd, a B-containing compound, a Li-containing compound and a Gd-containing compound, wherein the scintillator material exhibits an optical response signature for thermal neutrons that is different than an optical response signature for fast neutrons and gamma rays. A system according to one embodiment includes a scintillator material as disclosed herein and a photodetector for detecting the response of the material to fast neutron, thermal neutron and gamma ray irradiation.

36 MATERIALS SCIENCE↗

Detection of entrapped moisture in honeycomb sandwich structures

Thermal neutron moisture detection system detects entrapped moisture in intercellular areas of bonded honeycomb sandwich structures. A radium/beryllium fast neutron source bombards a specimen. The emitted thermal neutrons from the target nucleus are detected and counted by a boron trifluoride thermal neutron detector.

Hallmark, W. B.↗

Dense Plasma Focus Diagnostic Suite for the Surrogate Static Test

A Neutron Diagnosed Subcritical Experiment (NDSE) has been proposed to measure the reactivity of a subcritical ($k_{eff} <$ 1:0) plutonium experiment. This experiment requires a short, high-intensity neutron pulse delivered to the target material with precise timing. A feasibility study for the NDSE is being conducted jointly by National Security Technologies, LLC, and Los Alamos National Laboratory at Area 11 of the Nevada National Security Site. The goals of this study include characterizing and developing the proposed neutron pulse source, the fast photon detection system, and the shielding system to suppress scattering backgrounds.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring the scintillation decay time for different energy deposited by γ-rays and neutrons in a Cs 2 LiYCl 6 :Ce 3+ detector

In nuclear safeguards and homeland security applications, it is greatly beneficial to simultaneously detect γ-rays, thermal neutrons, and fast neutrons using a single detector with reasonable pulse shape discrimination capability, energy resolution comparable with or even better than NaI(Tl) detectors, and high detection efficiency. Cs 2 LiYCl 6 :Ce 3+ detector (CLYC) scintillation detectors have been proven to be one promising candidate to meet these requirements. In this work, the decay time and fraction of each scintillation component for different energy deposition and incident particle type (γ-ray, thermal neutron, and fast neutron) were investigated based on fitting the PMT anode output with exponential functions. For γ-rays, four components were determined with ultrafast decay time of less than one nanosecond and slow time in the order of magnitude of microsecond. It was found that the dependence on the energy deposited by γ-rays of the fraction as well as the decay time of the three slow components was small. However, significant dependence was observed for the ultrafast component. Two or three components were determined for thermal neutrons and fast neutrons without observing a component with fast decay time. To verify the approach used it was first applied to scintillation pulses induced by γ-rays in a NaI(Tl) detector. We found the results were consistent with well-known data already published in the literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A scintillator-based approach to monitor secondary neutron production during proton therapy

Here, the primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response for comparison to the measured data. Comparison of the measured and simulated data will validate this approach for monitoring secondary neutron dose during proton therapy. Proton beams of 155- and 200-MeV were used to irradiate a variety of phantom materials and secondary particles were detected using organic liquid scintillators. These detectors are sensitive to fast neutrons and gamma rays: pulse shape discrimination was used to classify each detected pulse as either a neutron or a gamma ray. The mcnpx-PoliMi code was used to simulate the secondary neutron field produced during proton irradiation of the same tissue-equivalent phantom materials. As a result, an experiment was performed at the Loma Linda University Medical Center proton therapy research beam line and corresponding models were created using the mcnpx-PoliMi code. The authors’ analysis showed agreement between the simulations and the measurements. The simulated detector response can be used to validate the simulations of neutron and gamma doses on a particular beam line with or without a phantom. In conclusion, the authors have demonstrated a method of monitoring the neutron component of the secondary radiation field produced by therapeutic protons. The method relies on direct detection of secondary neutrons and gamma rays using organic scintillation detectors. These detectors are sensitive over the full range of biologically relevant neutron energies above 0.5 MeV and allow effective discrimination between neutron and photon dose. Because the detector system is portable, the described system could be used in the future to evaluate secondary neutron and gamma doses on various clinical beam lines for commissioning and prospective data collection in pediatric patients treated with proton therapy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Fissile Assemblies Using Low-Efficiency Detection Systems

Here, we have investigated the possibility that the amount, chemical form, multiplication, and shape of the fissile material in an assembly can be passively assayed using scintillator detection systems by only measuring the fast neutron pulse height distribution and distribution of time intervals Δt between fast neutrons. We have previously demonstrated that the alpha-ratio can be obtained from the observed pulse height distribution for fast neutrons. In this paper we report that we report that when the distribution of time intervals is plotted as a function of logΔt, the position of the correlated neutron peak is nearly independent of detector efficiency and determines the internal relaxation rate for fast neutrons. If this information is combined with knowledge of the alpha-ratio, then the position of the minimum between the correlated and uncorrelated peaks can be used to rapidly estimate the mass, multiplication, and shape of fissile material. This method does not require a priori knowledge of either the efficiency for neutron detection or the alpha-ratio. Although our method neglects 3-neutron correlations, we have used previously obtained experimental data for metallic and oxide forms of Pu to demonstrate that our method yields good estimates for multiplications as large as 2, and that the only constraint on detector efficiency/observation time is that a peak in the interval time distribution due to correlated neutrons is visible.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Genetic algorithm optimization of tin–copper graded shielding for improved plutonium safeguards measurements

Plutonium nuclear material safeguards is essential to ensure that states do not divert plutonium to clandestine nuclear weapons programs. Traditional safeguards methods rely on correlated neutron measurements. Detection systems based on organic scintillators, which are sensitive to fast neutrons and photons, are gaining support for use in safeguards applications due to increased capabilities and shorter measurement times compared to the current state-of-the-art. A drawback of organic scintillators in plutonium measurements is data throughput limitations; 241 Am builds up in plutonium samples and emits 60-keV gamma rays with a high specific activity. In this work, a genetic algorithm is used to design graded shielding made of tin and copper to attenuate the 60-keV gamma rays. The shield is designed to limit the attenuation of the higher-energy, fission photons, because fission photons can be used as a signature. The genetic algorithm optimization takes days to run, while a complete search space exploration would take years. The genetic algorithm was run for different levels of 60-keV gamma-ray attenuation, and the thickness of the required shielding layers was determined at each level. Tin–copper shielding was placed in front of an array of organic scintillation detectors for a measurement of approximately 4.5 kg of alpha-phase, weapons-grade plutonium, an AmLi source, and a 252 Cf source. We show that the shield successfully attenuated low-energy, non-fission gamma rays, which significantly improved the organic scintillator performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗