Field Programmable Gate Array Data Capture for Control Systems

Some Industrial Control Systems (ICS) networks are based on protocols such as Serial and Industrial Ethernet. These protocols currently have no existing cybersecurity monitoring tools, leaving a large gap in the cyber defense of critical infrastructure. In order to analyze such ICS traffic, it is first necessary to implement methods of capturing the ICS data. Whereas traditional methods of analyzing data would use microprocessors, the nature of high-speed analog data can be difficult to implement on such a versatile processor, as they are rather inefficient for doing a single task. Whereas Field Programmable Gate Arrays (FPGAs) provide an adequate tool in analyzing high speed data, as despite the lack of program versatility, Programmable Logic can implement a solution with minimal clock cycles, allowing time for each new packet of data to be captured before a new data sample is taken.

42 ENGINEERING↗

A digitizer based compact digital spectrometer for ion beam analysis using field programmable gate arrays and various energy algorithms

We report on the implementation of a compact multi-detector fully digital spectrometer and data acquisition system at a nuclear microprobe for ion beam analysis and imaging. The spectrometer design allows for system scalability with no restriction on the number of detectors. It consists of four-channel high-speed digitizer modules for detector signal acquisition and one low-speed digital-to-analog converter (DAC) module with two DAC channels and additional general purpose inputs/outputs to control ion beam scanning and data acquisition. Each digitizer module of the spectrometer provides its own Field Programmable Gate Array (FPGA) as digital signal processing unit to analyze detector signals as well as to synchronize the ion beam position in hard real-time. With the customized FPGA designs for all modules, all calculation intensive tasks are executed inside the modules, which reduces significantly the data stream to and CPU load on the control computer. To achieve an optimal energy resolution for all detector/preamplifier pulse shape characteristics, a user-definable infinite impulse response filter with high throughput for energy determination was implemented. The new spectrometer has an online data analysis feature, a compact size, and is able to process any type of detector signals such as particle induced x-ray emission, Rutherford backscattering spectrometry, or scanning transmission ion microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image processing with cellular nonlinear networks implemented on field-programmable gate arrays for real-time applications in nuclear fusion

In the past years cameras have become increasingly common tools in scientific applications. They are now quite systematically used in magnetic confinement fusion, to the point that infrared imaging is starting to be used systematically for real-time machine protection in major devices. However, in order to guarantee that the control system can always react rapidly in case of critical situations, the time required for the processing of the images must be as predictable as possible. The approach described in this paper combines the new computational paradigm of cellular nonlinear networks (CNNs) with field-programmable gate arrays and has been tested in an application for the detection of hot spots on the plasma facing components in JET. The developed system is able to perform real-time hot spot recognition, by processing the image stream captured by JET wide angle infrared camera, with the guarantee that computational time is constant and deterministic. The statistical results obtained from a quite extensive set of examples show that this solution approximates very well an ad hoc serial software algorithm, with no false or missed alarms and an almost perfect overlapping of alarm intervals. The computational time can be reduced to a millisecond time scale for 8 bit 496x560-sized images. Moreover, in our implementation, the computational time, besides being deterministic, is practically independent of the number of iterations performed by the CNN - unlike software CNN implementations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of data acquisition interface using on-board field-programmable gate array (FPGA) universal serial bus (USB) link

Typically a system consists of hardware as the controller and software which is installed in the personal computer (PC). In the effective nuclear detection, the hardware involves the detection setup and the electronics used, with the software consisting of analysis tools and graphical display on PC. A data acquisition interface is necessary to enable the communication between the controller hardware and PC. Nowadays, Universal Serial Bus (USB) has become a standard connection method for computer peripherals and has replaced many varieties of serial and parallel ports. However the implementation of USB is complex. This paper describes the implementation of data acquisition interface between a field-programmable gate array (FPGA) board and a PC by exploiting the USB link of the FPGA board. The USB link is based on an FTDI chip which allows direct access of input and output to the Joint Test Action Group (JTAG) signals from a USB host and a complex programmable logic device (CPLD) with a 24 MHz clock input to the USB link. The implementation and results of using the USB link of FPGA board as the data interfacing are discussed.

42 ENGINEERING↗

The digital mirror Langmuir probe: Field programmable gate array implementation of real-time Langmuir probe biasing

High bandwidth, high spatial resolution measurements of electron temperature, density, and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements, either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimized for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customizable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g., real-time control outputs and more voltage states) and scalability through collaboration.

47 OTHER INSTRUMENTATION↗

The Digital Mirror Langmuir Probe: Field Programmable Gate Array Implementation of Real-Time Langmuir Probe Biasing

High bandwidth, high spatial resolution measurements of electron temperature, density and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimised for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customisable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g. real-time control outputs, more voltage states) and scalability through collaboration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-434: Development of a Fan-Beam Optical Scanner Using CMOS Array for Small Field Dosimetry

Purpose: To design and construct a second generation optical computed tomography (OCT) system using a fan-beam with a CMOS array detector for the 3D dosimetry with polymer gel and radiochromic solid dosimeters. The system was specifically designed for the small field dosimetry. Methods: The optical scanner used a fan-beam laser, which was produced from a collimated red laser beam (λ=620 nm) with a 15-degree laser-line generating lens. The fan-beam was sent through an index-matching bath which holds the sample stage and a sample. The emerging laser light was detected with a 2.54 cm-long CMOS array detector (512 elements). The sample stage rotated through the full 360 degree projection angles at 0.9-degree increments. Each projection was normalized to the unirradiated sample at the projection angle to correct for imperfections in the dosimeter. A larger sample could be scanned by using a motorized mirror and linearly translating the CMOS detector. The height of the sample stage was varied for a full 3D scanning. The image acquisition and motor motion was controlled by a computer. The 3D image reconstruction was accomplished by a fan-beam reconstruction algorithm. All the software was developed inhouse with MATLAB. Results: The scanner was used on both PRESAGE and PAGAT gel dosimeters. Irreconcilable refraction errors were seen with PAGAT because the fan beam laser line refracted away from the detector when the field was highly varying in 3D. With PRESAGE, this type of error was not seen. Conclusion: We could acquire tomographic images of dose distributions by the new OCT system with both polymer gel and radiochromic solid dosimeters. Preliminary results showed that the system was more suited for radiochromic solid dosimeters since the radiochromic dosimeters exhibited minimal refraction and scattering errors. We are currently working on improving the image quality by thorough characterization of the OCT system.

60 APPLIED LIFE SCIENCES↗

Phased Array Ultrasonic Sound Field Mapping through Large-Bore Coarse Grained Cast Austenitic Stainless Steel (CASS) Components

A sound field beam mapping exercise was conducted to assist in understanding the effects of coarse-grained microstructures found in cast austenitic stainless steel (CASS) materials on acoustic longitudinal wave propagation. Ultrasonic laboratory measurements were made on three specimens representing four different grain structures. Phased array (PA) probes were fixed on each specimen surface and excited in the longitudinal mode at specific angles while a point receiver was scanned in a raster pattern over the end of the specimen, generating a transmitted sound field image. Three probes operating at nominal frequencies of 0.5, 0.8, and 1.0 MHz were used. A 6.4 mm (0.25-in.) thick slice was removed from the specimen end and beam mapping was repeated three times, yielding four full sets of beam images. Data were collected both with a constant part path for each configuration (probe, specimen and slice, angle, etc.) and with a variable part path (fixed position on the surface). The base specimens and slices were then polished and etched to reveal measureable grain microstructures that were compared to the sound field interactions and scattering effects seen in the collected data.

cast austenitic stainless steel↗

Microfabricated atomic vapor cell arrays for magnetic field measurements

We describe a method for charging atomic vapor cells with cesium and buffer gas. By this, it is possible to adjust the buffer gas pressure in the cells with good accuracy. Furthermore, we present a new design of microfabricated vapor cell arrays, which combine silicon wafer based microfabrication and ultrasonic machining to achieve the arrays of thermally separated cells with 50 mm{sup 3} volume. With cells fabricated in the outlined way, intrinsic magnetic field sensitivities down to 300 fT/Hz{sup 1/2} are reached.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reentrant quantum phase transitions in two capacitively coupled Josephson arrays in perpendicular magnetic fields

We have studied the phase diagram structure of two capacitively coupled Josephson junction arrays as a function of their charging energy E{sub c}, Josephson coupling energy E{sub J}, and a homogeneous perpendicular magnetic field. The arrays are coupled via a site interaction capacitance, C{sub int}=C{sub inter}/C{sub m}, with C{sub inter} as the interlayer mutual capacitance and C{sub m} as the intralayer mutual capacitance defined as the nearest neighbor grain mutual capacitance. The parameter that measures the competition between thermal and quantum fluctuations in the ith array (i=1,2) is {alpha}{sub i}{identical_to}E{sub c{sub i}}/E{sub J{sub i}}. The phase structure of the system is dominated by the thermally induced and magnetically induced vortices as well as intergrain charge induced excitations. We have studied the capacitively coupled array behavior when one of them is in the vortex dominated regime, and the other in the quantum charge dominated regime. We determined the different possible phase boundaries by carrying out extensive quantum path integral Monte Carlo calculations of the helicity modulus {upsilon}{sub 1,2}({alpha},f) and the inverse dielectric constant {epsilon}{sub 1,2}{sup -1}({alpha},f) for each array as a function of temperature, interlayer capacitance C{sub int}, quantum parameter {alpha}, and frustration values f{identical_to}({phi}/{phi}{sub 0})=1/2 and f=1/3. Here, {phi} is the total flux in a plaquette and {phi}{sub 0} is the quantum of flux. We found an intermediate temperature range when array 1 is in the semiclassical regime ({alpha}{sub 1}=0.5) and array 2 is in the quantum regime with 1.25{<=}{alpha}{sub 2}<2, in which {upsilon}{sub 2}(T,{alpha},f=1/2)>0 and then goes down to zero while {epsilon}{sub 2}{sup -1}(T,{alpha},f=1/2) increases from zero up to a finite value. This behavior is similar to the one previously found for unfrustrated capacitively coupled arrays. However, for {alpha}{sub 2}=2.0, a reentrant transition in {upsilon}{sub 2}(T,{alpha},f=1/2) occurs at intermediate temperatures for C{sub int}=0.782 61, 1.043 48, and 1.304 35. For smaller values of the interlayer capacitance no phase coherence was found in array 2. This suggest that the increase between the array capacitive coupling induces a normal-superconducting-normal (N-SC-N) reentrant phase transition. For values of {alpha}{sub 2}>2.0, the quantum array only exhibits an insulating phase, while the semiclassical array shows a superconducting behavior. In contrast, for phase frustration, f=1/3, we found that when array 2 is in the full quantum regime, 2{<=}{alpha}{sub 2}{<=}4, the semiclassical array is the one that shows a reentrant N-SC-N behavior at relatively low temperatures. This reentrance in the coupled array behavior is a manifestation of the gauge invariant capacitive interaction and the duality relation between vortices, in the semiclassical array, and charges in the quantum-fluctuation dominated array. We find that the phase diagrams for f=1/2 and f=1/3 are very different in nature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A field programmable gate array-based timing and control system for the dynamic compression sector

A field programmable gate array (FPGA)-based timing and trigger control system has been developed for the Dynamic Compression Sector (DCS) user facility located at the Advanced Photon Source (APS) at Argonne National Laboratory. The DCS is a first-of-its-kind capability dedicated to dynamic compression science. All components of the DCS laser shock station—x-ray choppers, single-shot shutter, internal laser triggers, and shot diagnostics—must be synchronized with respect to the arrival of x rays in the hutch. An FPGA synchronized to the APS storage ring radio frequency clock (352 MHz) generates trigger signals for each stage of the laser and x-ray shutter system with low jitter. The developed FPGA-based control system was the first system used to control the laser and the shutter system since its commissioning, and it has been developing since then to improve the timing jitter. The system is composed of a Zynq FPGA, a debug card, line drivers, and a power supply. The delay and offsets of the trigger signals can be adjusted by using a user-friendly graphical user interface with high precision. Here, the details of the system architecture, timing requirements, firmware, and software implementation along with the performance evaluation are presented in this paper. The system offers low timing jitter (15.5 ps rms) with respect to the APS 352 MHz clock, suitable for the 100 ps (FWHM) x-ray bunch duration at the APS.

47 OTHER INSTRUMENTATION↗

Radio Frequency Field Programable Gate Array Implementation of Reflectometry Cable Monitoring

PNNL has developed an innovative cable testing system that leverages the Xilinx RF System-on-Chip (RFSoC) technology to create a more flexible and capable measurement tool than traditional approaches. The architecture is designed on the ZCU111 development board and takes advantage of the high-speed digital to analog converters (DAC) and analog to digital converters (ADC) to generate and capture digitally synthesized waveforms. The platform allows engineers to easily adjust power, frequency, duration and modulation on the fly rather than being locked into fixed hardware configurations

Tedeschi, Jonathan [Pacific Northwest National Lab↗

Evaluation of nested wire array dynamics with mixed wire array Z pinches.

A series of experiments at the Z Accelerator was performed with 40mm and 50mm diameter nested wire arrays to investigate the interaction of the arrays and assess radiative characteristics. These arrays were fielded with one array as Al:Mg (either the inner or the outer array) and the other array as Ni-clad Ti (the outer or inner array, with respect to location of the Al:Mg). In all the arrays, the mass and radius ratio of the outer:inner was 2:1. The wire number ratio was also 2:1 in some cases, but the Al:Mg wire number was increased in some loads. This presentation will focus on analysis of the emitted radiation (in multiple photon energy bins) and measured plasma conditions (as inferred from x-ray spectra). A discussion on what these results indicate about nested array dynamics will also be presented.

43 PARTICLE ACCELERATORS↗