Search NASASearch

SEARCH · Search NASA

Results for “Field operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System

The Athena Mars Rover Science Payload

The Mars Surveyor missions that will be launched in April of 2001 will include a highly capable rover that is a successor to the Mars Pathfinder mission's Sojourner rover. The design goals for this rover are a total traverse distance of at least 10 km and a total lifetime of at least one Earth year. The rover's job will be to explore a site in Mars' ancient terrain, searching for materials likely to preserve a record of ancient martian water, climate, and possibly biology. The rover will collect rock and soil samples, and will store them for return to Earth by a subsequent Mars Surveyor mission in 2005. The Athena Mars rover science payload is the suite of scientific instruments and sample collection tools that will be used to perform this job. The specific science objectives that NASA has identified for the '01 rover payload are to: (1) Provide color stereo imaging of martian surface environments, and remotely-sensed point discrimination of mineralogical composition. (2) Determine the elemental and mineralogical composition of martian surface materials. (3) Determine the fine-scale textural properties of these materials. (4) Collect and store samples. The Athena payload has been designed to meet these objectives. The focus of the design is on field operations: making sure the rover can locate, characterize, and collect scientifically important samples in a dusty, dirty, real-world environment. The topography, morphology, and mineralogy of the scene around the rover will be revealed by Pancam/Mini-TES, an integrated imager and IR spectrometer. Pancam views the surface around the rover in stereo and color. It uses two high-resolution cameras that are identical in most respects to the rover's navigation cameras. The detectors are low-power, low-mass active pixel sensors with on-chip 12-bit analog-to-digital conversion. Filters provide 8-12 color spectral bandpasses over the spectral region from 0.4 to 1.1 micron Narrow-angle optics provide an angular resolution of 0.28 mrad/pixel, nearly a factor of four higher than that of the Mars Pathfinder and Mars Surveyor '98 cameras. Image compression will be performed using a wavelet compression algorithm. The Mini-Thermal Emission Spectrometer (Mini-TES) is a point spectrometer operating in -the thermal IR. It produces high spectral resolution (5 /cm) image cubes with a wavelength range of 5-40 gm, a nominal signal/noise ratio of 500:1, and a maximum angular resolution of 7 mrad (7 cm at a distance of 10 in). The wavelength region over which it operates samples the diagnostic fundamental absorption features of rockforming minerals, and also provides some capability to see through dust coatings that could tend to obscure spectral features. The mineralogical information that Mini-TES provides will be used to select from a distance the rocks and soils that will be investigated in more detail and ultimately sampled. Mini-TES is derived from the MO/MGS TES instrument, but is significantly smaller and simpler. The instrument uses an 8-cm Cassegrain telescope, a Michelson interferometer, and uncooled pyroelectric detectors. Along with its mineralogical capabilities, Mini-TES can provide information on the thermophysical properties of rocks and soils. Viewing upward, it can also provide temperature profiles through the martian atmospheric boundary layer. Elemental and Mineralogical Composition: Once promising samples have been identified from a distance using Pancam/Mini-TES, they will be studied in detail using up to three compositional sensors that can be placed directly against them by an Instrument Arm. The two compositional sensors, presently on the payload are an Alpha-Proton-X-Ray Spectrometer (APXS), and a Mossbauer Spectrometer. The APXS is derived closely from the instrument that flew on Mars Pathfinder. Radioactive alpha sources and three detection modes (alpha, proton, and x-ray) provide elemental abundances of rocks and soils to complement and constrain mineralogical data. The Athena APXS will have a revised mechanical design that will cut down significantly on backscattering of alpha particles from martian atmospheric carbon. It will also include a target of known elemental composition that will be used for calibration purposes. The Athena Mossbauer Spectrometer is a diagnostic instrument for the mineralogy and oxidation state of Fe-bearing phases, which are particularly important on Mars. The instrument measures the resonant absorption of gamma rays produced by a Co-57 source to determine splitting of nuclear energy levels in Fe atoms that is related to the electronic environment surrounding them. It has been under development for space flight for many years at the Technical University of Darmstadt. The Mossbauer Spectrometer (and the other arm instruments) will be able to view a small permanent magnet array that will attract magnetic particles in the martian soil. The payload may also include a Raman Spectrometer. If included, the Raman Spectrometer will provide precise identification of major and minor mineral phases. It requires no sample preparation, and is also sensitive to organics. Fine-Scale Texture: The Instrument Arm a also carries a Microscopic Imager that will obtain high-resolution monochromatic images of the same materials for which compositional data will be obtained. Its spatial resolution is 20 micron/pixel over a 1 cm depth of field, and 40 micron/pixel over a 1-cm depth of field. Like Pancam, it uses the same active pixel sensor detectors and electronics as the rover's navigation cameras. The Instrument Arm is a three degree-of-freedom arm that uses designs and components from the Mars Pathfinder and Mars Surveyor '98 projects. Its primary function is instrument positioning. Along with the instruments noted above, it also carries a brush that can be used to remove dust and other loose coatings from rocks. Sample Collection and Storage: Martian rock and soil samples will be collected using a low-power rotary coring drill called the Mini-Corer. An important characteristic of this device is that it can obtain intact samples of rock from up to 5 cm within strong boulders and bedrock, Nominal core dimensions are 8xl7 mm. The Mini-Corer drills a core to the commanded depth in a rock, shears it off, retains it, and extracts it. It can also acquire samples of loose soil, using soil sample cups that are pressed downward into loose material. The Mini-Corer can drill at angles from vertical to 45' off vertical. It has six interchangeable bits for long life. Mechanical damage to the sample during drilling is minimal, and heating is negligible. After acquisition, the sample may be viewed by the arm instruments, and/or placed in one of 104 compartments in the Sample Container. A subset of the acquired samples may be replaced with other samples obtained later if desired. The Sample Container has no moving parts, and is mounted external to the rover for easy removal by the Mars Surveyor 2005 flight system. Operation of the rover will make extensive use of automated onboard navigation and hazard avoidance capabilities. Otherwise, use of onboard autonomy is minimal. Data downlink capability is about 40 Mbit/sol, and the use of the Mars Surveyor '01 orbiter for data relay imposes a limit of at most two command cycles per sol. Because of the significant amount of time available between command cycles, all payload elements will be operated sequentially, rather than in parallel.; this approach also significantly simplifies operations and minimizes peak power usage. The landing site for the '01 rover has not been selected yet. Site selection will make as full use as possible of Mars Global Surveyor data, and will involve substantial input from the broad Mars science community. Summary: The following table describes the mass, power, providers, and key scientific objectives of all the major elements of the Athena payload. Additional Athena payload information may be found at: http://astrosun.tn.cornell.edu/athena/index.html. Additional information contained in the original.

Squyes, S. W.

Unravelling the origins of shale nanoporosity using small-angle neutron scattering (SANS)

Hydrocarbon production from tight rocks is constrained by slow diffusion within the shale matrix, limited by small pore sizes and low permeability. The nanopore proportion and size distribution significantly influence matrix permeability, a key property for optimizing hydrocarbon recovery and supporting hydrogen production while minimizing environmental impacts. Small-angle neutron scattering (SANS) has been an important tool for exploring the characteristics and structure of shale nanopores. This study used SANS to analyze nanoporosity and pore size distribution (<100 nm) in tight rocks with varying compositions to determine the influence of rock heterogeneity on SANS measurements. Results showed that nanoporosity correlates with clay content, with the highest clay-rich shale (52.48 wt% clay) exhibiting 8.8 % nanoporosity. SANS also revealed more nanopores than traditional nitrogen adsorption measurements, affirming its ability to reflect bulk mineralogy and upholding the relevance of experimental findings using this technique to optimize field operational approaches.

03 NATURAL GAS

A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION

Enhanced passivation and stability of negative charge injected SiN x with higher nitrogen content on the boron diffused surface of n-type Si solar cells

This paper explores the potential of the negatively charged SiN x using plasma charge injection technology to passivate the front textured boron-diffused emitter of n-type Si solar cells. The high-x value single SiN x layer with x ≥ 1.30 (x = N/Si) previously developed for the planarized rear-side passivation of p-type silicon solar cells, with an excellent passivation and charge stability, was found to be unacceptable for the passivation on the front textured boron emitter of n-type cells due to a severe bulk lifetime degradation issue. Therefore, in this study, we investigated a new concept of depositing a dual-x SiN x with a low-x SiN x layer (x~1.01) on top of a high-x SiN x layer (x~1.30) for passivation of the front textured rough surface of boron diffused emitter in n-type cells. Here, the optimized dual-x SiN x stack reveals the promise of charge retention for more than 25 years in field operation as well as excellent passivation of boron-doped emitter without bulk lifetime degradation. N-type cells with the optimized dual-x SiN x after charge injection show comparable cell performance to Al 2 O 3 passivated reference cells. The results of cell-level light stability tests using one-cell minimodules exhibit cell performance decay characteristics similar to the traditional Al 2 O 3 /SiN x passivated reference module.

14 SOLAR ENERGY

Interpretation of high-harmonic fast-wave propagation in the scrape-off layer of NSTX-U as a geometrically bounded-waveguide mode

This paper revisits the onset of high-harmonic fast-wave (HHFW) propagation in the scrape-off layer (SOL) plasma of the NSTX/NSTX-U spherical tokamak, motivated by past HHFW heating and current drive experiments and modelling. Previously, the fast-wave propagation in the SOL was correlated with the opening (suppression) of the fast-wave right-hand cutoff layer in front of the antenna. In this work, the SOL propagation is interpreted as a geometric waveguide mode guided by the SOL geometry, whose radial width can be comparable to the wave’s perpendicular wavelength in the HHFW regime. A two-dimensional circular model is first employed using full-wave solvers to characterise the poloidal eigenmode structures and to clarify their relationship to annulus resonance. By progressively adding a tokamak-like magnetic-field configuration, starting from a uniform axial field, the effects of magnetic-field gradients and pitch on the SOL waveguide mode are characterised. The poloidal mode numbers supported by the SOL plasma agree well with analytic estimates, indicating that an anisotropic plasma in a bounded geometry selectively supports and amplifies the resonant poloidal mode number. Additionally, two-dimensional axisymmetric NSTX-U simulations demonstrate that the SOL eigenmode features identified in the circular model persist in the experimentally relevant configurations. A control approach based on lengthening the wave perpendicular wavelength relative to the SOL width, including a higher magnetic (B)-field operation, is discussed. The analysis here shows the key role of a bounded geometry in interpreting HHFW eigenmode coupling and propagation in the NSTX-U SOL plasma.

plasma heating

First study of polarized proton-proton scattering with small-𝑥 helicity evolution

We perform a phenomenological study of helicity-dependent parton distribution functions (PDFs) using small-𝑥 helicity evolution equations, incorporating for the first time single-inclusive jet production data in polarized proton-proton (𝑝⁢𝑝) scattering at parton momentum fractions 𝑥 <0.1. We also simultaneously include double-longitudinal spin asymmetries in inclusive and semi-inclusive deep-inelastic scattering probing 𝑥 <0.1. Employing the polarized small-𝑥 pure-glue calculation of 𝑝⁢𝑝 → 𝑔⁡𝑋 for the jet production cross section, we modify the large-𝑁 𝑐 &𝑁 𝑓 KPS-CTT evolution equations by setting 𝑁 𝑓 = 0 to replicate the large-𝑁𝑐 (pure-glue) limit, while retaining external quark flavors for the spinor field operators. We find that the 𝑝⁢𝑝 data have a considerable impact on the helicity PDFs at small 𝑥, reducing their uncertainties and leading to a total quark and gluon helicity in the proton for 𝑥 < 0.1 of −0.04 ±0.23. Combining our analysis with a recent JAM helicity PDF analysis of the world polarized data, which includes 𝑥 > 0.1, we find a total quark and gluon helicity contribution for 𝑥 >10 −7 of between 0.02 and 0.51.

Adamiak, Daniel [Michigan State University] (ORCID

Site Characterization of the Highest-Priority Geologic Formations for CO2 Storage in Wyoming

The project Site Characterization of the Highest-Priority Geologic Formations for CO2 Storage in Wyoming is one of 9 site characterization projects that were implemented as part of ARRA (American Recovery and Reinvestment Act). Data from this project was used to improve resolution of data in NATCARB in the area of study. Data related to this study has already been incorporated in NATCARB Atlas. The Wyoming Carbon Underground Storage Project (WY-CUSP) consisted of CO2 storage site characterization and evaluation, focusing on Wyoming’s most promising CO2 storage reservoirs (the Pennsylvanian Weber/Tensleep Sandstone and Mississippian Madison Limestone) and premier CO2 storage site (Rock Springs Uplift). Results from the WY-CUSP project suggest the two reservoirs could store up to 17,000 million tons of CO2. The WY-CUSP team drilled a stratigraphic test well and acquired a 3-D seismic survey covering 25 square miles of the Rock Springs Uplift site. The team retrieved 916 feet of core from the 12,810-foot-deep well, along with a complete log suite, borehole images, fluid samples, and other data. Project partners (1) provided continuous visual documentation of the core, including grain size, mineralogy, facies distribution, and porosity; (2) performed continuous permeability and velocity scans of selected reservoir intervals; and (3) chemically analyzed the fluid samples. WY-CUSP scientists integrated seismic attributes with observations from log suites, a VSP survey, core, fluid samples, and laboratory analyses, including continuous permeability scans. From these integrations, researchers constructed 3-D spatial distribution volumes of reservoir and seal properties that represent geological heterogeneity at the targeted CO2 storage site. The WY-CUSP team used this data to perform new CO2 plume migration simulations. Baker Hughes, Inc., completed a series of small-scale, in-situ water injectivity measurements. A database was formed when observations, analyses, and experiments from the stratigraphic test well were integrated. Correlation of these data allowed petrophysical parameters to be extrapolated from the test well out into the storage domain (5x5 mile 3-D seismic survey volume). This resulted in an improved, realistic understanding of performance assessments for potential CO2 storage scenarios. The WY-CUSP team worked on (1) improving CO2 storage resource estimates, (2) establishing long-term integrity and permanence of confining layers, (3) designing a profitable strategy for pressure management, and (4) evaluating the utilization of stored CO2 at the Rock Spring Uplift. Finally, Baker Hughes developed a microseismic baseline for the test site using in-bore geophones to complete field operations.

3-D seismic

Geochemical Impact of Acid Spearhead and Slickwater Stimulation on Wolfcamp Shale from the Hydraulic Fracturing Test Site

The Hydraulic Fracturing Test Site 1 (HFTS-1) was a field study performed in the Wolfcamp Formation in the West Texas Permian (Midland) Basin, USA, with a focus on improving the efficiency of hydraulic fracturing. Investigating site-specific rock-fluid geochemical interactions during hydraulic fracturing is an important step to understanding the impact on formation shale porosity, permeability, and long-term shale gas production. During field operations in this region, hydraulic fracturing fluid (HFF) injection usually starts with a concentrated acid spearhead for rapid rock dissolution, followed by the injection of near-neutral pH slickwater containing chemicals and proppants. A multistep sequential injection approach was used to investigate different stages of rock-fluid interactions. The carbonate content in the host rock is important when acid spearhead is considered, as carbonate mineral dissolution is rapid and can result in porosity and permeability changes in the shale matrix. Here, in this study, we designed flow-through experiments using fractured carbonate-rich and clay-rich Wolfcamp shale cores with (1) a short-time acid soaking step and (2) a long-term slickwater flow-through step to simulate the injection method used at HFTS-1. The fluid chemistry was analyzed. A thorough mineralogical progression [e.g., Calcium (Ca) dissolution and iron (Fe) redox progression] in the cores during HFF injection was also characterized and imaged by synchrotron microprobe. Reactive transport modeling was performed based on the experimental setup. The results showed that the acid spearhead is a crucial step in creating a reaction front by mineral dissolution, especially in carbonate-rich shales. A slight layer of ferrihydrite precipitated during the slickwater flow-through period. This study provides insights into potential geochemical impact due to hydraulic fracturing operations in the Permian Basin.

clastic rock

Carbon Storage Core Characterization Efforts at NETL

The multi-scale Computed Tomography (CT) and core flow facility in the Geocharacterization Laboratory at NETL, Morgantown yields porosity, permeability, and fracture properties of rock core samples obtained from the subsurface while maintaining the integrity of the sample. Additionally, geophysical bulk rock properties are analyzed with the laboratory’s GeoTEK multi-sensor core logger in a comparable fashion to downhole methods. NETL researchers collaborate with stakeholders within the carbon storage, oil and gas, and critical minerals sectors. Since 2017, over 1.88 miles of core have been analyzed within the laboratory and all data is publicly available through the Technical Report Series (TRS) on the Energy Data eXchange (EDX). Additionally, the website, RokBase, was curated to extrapolate and visualize the high-resolution data from field operations. The characterization of the Lively Grove #1 (LG#1) well provides a case study into the full capabilities of the Geocharacterization Laboratory. During the comprehensive study of LG#1 ~1-2 mm in diameter, vertical to bedding, cylindrical structures were identified throughout the St. Peter Formation. These structures are pervasive throughout the St. Peter Formation at depth and are characterized as the trace fossil, Skolithos.

Isom, Shelby L

Physics Coupled Machine Learning Applications for Geological Carbon Storage

Poster presented at the 17th International Conference on Greenhouse Gas Control Technologies GHGT-17 held in Calgary, Canada, October 20-24, 2024. In this poster, a physics-based method, CRM is coupled with the advanced artificial intelligence (AI)/machine learning (ML) models in virtual learning environment (VLE) for three-dimension details of reservoir responses and evaluations for a comprehensive understanding for CCS field operations and reservoir managements.

Liu, Guoxiang

Southwest Regional Partnership on Carbon Sequestration: Phase III (Final Scientific/Technical Report)

The Southwest Regional Partnership on Carbon Sequestration (SWP) is one of 7 regional partnerships formed in 2003 under the U.S. Department of Energy’s (DOE) Regional Carbon Sequestration Partnerships (RCSPs) initiative. The overall purpose of the initiative was to help determine and implement the technology, infrastructure, and regulations most appropriate to promote carbon storage in different regions of the country. Covering Arizona, Colorado, New Mexico, Oklahoma, Utah, and parts of Texas, Wyoming, and Kansas, the SWP evaluated regional carbon storage and utilization potential and focused on technologies and sites that could complement the region’s strong position in energy production. The project progressed through three phases: • Phase I (2003–2005): Characterized regional geologic formations and CO 2 sources, assessed sequestration potential, and identified pilot test sites. • Phase II (2005–2013): Conducted small-scale field tests to validate sequestration methods, including geologic and terrestrial projects. • Phase III (2008–2022): Demonstrated large-scale CO 2 injection at a commercial oil field to test monitoring, verification, and long-term storage strategies. This report covers Phase III. The final project site, the Farnsworth Unit (FWU) in Texas, provided real-world testing of reservoir characterization, monitoring, and risk evaluation tools and processes that could be used in any commercial scale carbon capture, utilization, and storage (CCUS) project. Extensive data collection and analysis helped refine best practices for reservoir characterization, injection monitoring, and storage verification. The SWP contributed to national databases, DOE best practice manuals, and regional geological assessments to support future sequestration efforts. Key lessons learned include the importance of robust data management, strategic site selection, regulatory navigation, and effective industry collaboration. The project’s findings will inform ongoing and future carbon storage initiatives. Task 1 (Regional Characterization) • The SWP continued to participate in national outreach efforts and NATCARB. • The SWP evaluated multiple potential sites before selecting the FWU as the primary field test location. Task 2 (Public Outreach and Education) • The SWP contributed to national databases, DOE best practice manuals, and regional geological assessments to support future sequestration efforts. Task 3 (Permitting and Regulatory Compliance) • The SWP ensured compliance with federal and state regulations, including National Environmental Policy Act (NEPA) requirements. • The SWP obtained all necessary permits for drilling, injection, and monitoring activities. Task 4 (Site Characterization and Planning) • The SWP developed work plans for four key activities: characterization, simulation, monitoring and verification, and risk evaluation. • The SWP collected and synthesized legacy data from multiple sources to build initial static geological models and dynamic reservoir models demonstrating project feasibility. • The SWP conducted an initial risk evaluation and developed mitigation plans. Task 5 (Field Operations and Data Collection) • The SWP drilled, logged, and cored three characterization wells to gather critical subsurface data. • The SWP conducted multiple geophysical surveys, including 3D seismic, crosswell seismic, and vertical seismic profiling, to improve reservoir characterization. Task 6 (Monitoring and Verification) • The SWP performed extensive geological characterization using data from characterization wells and seismic surveys. • The SWP established a surface monitoring network to track CO 2 flux in soil gas, groundwater chemistry, and near-surface atmospheric CO 2 levels. • The SWP built and refined reservoir models to study the effects of relative permeability on simulation behavior and improve calibration with experimental data. Task 7 (Risk Assessment and Model Refinement) • The SWP conducted multiple studies to evaluate reservoir integrity, predict CO 2 plume behavior and improve predictive modeling capabilities. • The SWP refined geological models and used them to enhance the accuracy of simulation models. • The SWP continued quantitative risk assessment of top-ranked risks and strengthened the link between qualitative and quantitative risk methodologies.

02 PETROLEUM

TEAMER – Harvesting Subsea Water Motion to Provide Clean Electrical Power (Abstract)

Power generation from vortex induced vibration (VIV) is an emerging field with new technologies that are just beginning to be field tested. In this TEAMER project, WITT Energy will be field testing the power production of its pendulum system in two different configurations to evaluate its performance. The amount of power produced by a VIV instrument depend on the frequency at which it vibrates. The vibrational frequency is controlled by the device shape and its interaction with the flow velocity. Computer models are used to predict vibration frequencies as a function of flow velocity but they may be inaccurate due to complicated bathymetry and bottom roughness that is not captures by the models. This project will test the WITT VIV device in the Sequim Bay channel over a range of tidal velocities. Two tests will be completed with different pipe lengths that are expected to vary the vibrational frequency and therefore the power produced. PNNL will use an acoustic doppler current profiler (ADCP) to monitor the flow conditions during the tests. These tests will help WITT Energy evaluate how closely field operations follow computer model predictions and how best to configure their device for electricity production.

16 TIDAL AND WAVE POWER

II. Aerodynamic research relative to variable-sweep multimission aircraft

The development of a multimission military aircraft would be highly desirable both from the standpoint of easing the strain on the national budget by reducing the number of aircraft types and of providing versatility which would increase the effectiveness of the aircraft in the performance of a given mission. Some of the capabilities which might be required of such an aircraft are shown in figure 1 along with their respective aerodynamic and configuration requirements. The first three capabilities are grouped together since they all require good subsonic characteristics. The first, a long loiter capability for combat air patrol and the second, a long ferry range for efficient aircraft deployment both require a high subsonic lift-drag ratio. The third capability, STOL, is desirable for carrier and short-field operation and requires the development of high lift. All three of these capabilities can best be obtained with a high-aspect-ratio wing having a large span and a low-sweep angle. The fourth capability is that of a high-altitude supersonic attack or intercept and requires a high lift-drag ratio at supersonic speeds which dictates a rather slender configuration with a moderate-span wing which is either very thin or highly swept. The fifth capability listed in figure 1 is that of a low-altitude high-speed attack that would increase the probability of long-range penetration of antiaircraft defenses. The high dynamic pressures encountered on the deck at high speeds require a low-lift-curve slope to reduce the gust-induced normal accelerations, and low friction and wave drag (drag due to lift is insignificant at high dynamic pressures) to assure sufficient speed and range. In order to best satisfy these requirements, a slender aircraft having little or no wing is required. It is apparent from figure 1 that these five capabilities are highly incompatible and that an efficient multimission aircraft will require a means of varying its aerodynamic characteristics. This can be best accomplished with some type of variable-wing geometry. There are, of course, several types of variable wing geometry. However, in view of the extremely large variations in wing span desired, variable wing sweep, as indicated In the lower right sketch of figure 1, appears to provide the best method. The Langley Research Center of the National Aeronautics and Space Administration has therefore initiated a research program to provide the aerodynamic information needed for the development of a variable-sweep multimission military aircraft, and it is the purpose of this paper to briefly describe some of the results of this program.

Military aircraft

Microwave thermal noise standards.

Microwave thermal noise standards, discussing construction, calibration and errors for field operational liquid nitrogen cooled waveguide noise standard

Stelzried, C. T.

Microwave cryogenic thermal-noise standards

Field operational waveguide noise standard with nominal noise temperature of 78.09 plus/minus 0.12 deg K is calibrated more precisely than before. Calibration technique applies to various disciplines such as microwave radiometry, antenna temperature and loss measurement, and low-noise amplifier performance evaluation.

Stelzried, C. T.