Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Department of Transportation PHMSA Aerosol Spray Project: Phase-0

This report discusses the work conducted at Sandia National Laboratories during the preliminary phase (Phase-0) of the Department of Transportation (DOT) Pipeline and Hazardous Materials Safety Administration (PHMSA) project tasked to better understand what happens to a high-pressure liquid canister or vessel during a fire in which an accidental instantaneous release occurs. Phase 0 had two main objects: (1) to establish a methodology for the high temperature and pressure spray vessel release and (2) to characterize the spray droplet formation. For this test series, diagnostic equipment such as the Malvern Spraytec, high-speed photometric cameras, pencil gauges, and thermocouples were used. Additionally, the effect of surface tension on the particle size distribution was evaluated with 1-liter of distilled water and with the same including the addition of 0.5% soap/water mixture. Results from this effort indicated that the plume formed from the instantaneous release in all conditions primarily included two distinct particle size distributions including 217-312µm and 0.53µm on average. Soapy water formed a higher concentration of smaller mist (0.53µm) than distilled water, potentially due to decreased surface tension with the added surfactant. Though results showed good correlation to certain particle size distributions it is encouraged to conduct additional tests like this with a wider range of liquids with different properties, which could affect the overall particle size distribution when released.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Risk Assessment Models (HyRAM) (Version 3.0 Technical Reference Manual)

The HyRAM software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM is designed to facilitate the use of state-of-the-art science and engineering models to conduct robust, repeatable assessments of hydrogen safety, hazards, and risk. HyRAM includes generic probabilities for hydrogen equipment failures, probabilistic models for the impact of heat flux on humans and structures, and computationally and experimentally validated first-order models of hydrogen release and flame physics. HyRAM integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing hydrogen hazards (thermal effects from jet fires, overpressure effects from deflagrations), and assessing impact on people and structures. HyRAM is developed at Sandia National Laboratories for the U.S. Department of Energy to increase access to technical data about hydrogen safety and to enable the use of that data to support development and revision of national and international codes and standards. HyRAM is a research software in active development and thus the models and data may change. This report will be updated at appropriate developmental intervals. This document provides a description of the methodology and models contained in the HyRAM version 3.0. HyRAM 3.0 includes the new ability to model cryogenic hydrogen releases from liquid hydrogen systems, using a different property calculation method and different equations of state. Other changes include modifications to the ignition probability calculations, component leak frequency calculations, and addition of default impulse data.

08 HYDROGEN↗

Detecting Short Circuits: Post Accident Electric Vehicle Battery Safety Check

Fast and accurate detection of soft short circuits (SCs) in the battery packs of damaged electric vehicles is needed by first responders and mechanics to mitigate the potential risk from battery fires that may occur hours, days, or weeks after an accident. Here, this paper presents an SC-detection algorithm for potentially damaged lithium-ion batteries that works quickly and without a priori knowledge of the battery-pack chemistry, capacity, state of charge, or state of health. The proposed universal SC-detection algorithm is designed to be implemented on an inexpensive handheld device that can connect to and monitor the voltages of all cells in a pack. Transient filtering and linear-quadratic state observation provide estimates of normalized SC current for every cell in the pack. Cells with SC-current estimates outside a sigma-based threshold are detected. Simulations, experiments, and electric vehicle (EV) crash data are used to verify the speed, sensitivity, and accuracy of the method, demonstrating 96% accurate detection of 0.0027 C SCs in under 1 h for 5S cell groups in the lab and no false positives for crashed Volkswagen, Chevrolet, and Tesla vehicles without SCs.

25 - ENERGY STORAGE↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 4.1 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, methane, and propane systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards, and to provide developed models in a publicly-accessible toolkit usable by all stakeholders. This document provides a description of the methodology and models contained in HyRAM+ version 4.1. The two most significant changes for HyRAM+ version 4.1 from HyRAM+ version 4.0 are direct incorporation of unconfined overpressure into the QRA calculations and modification of the models for cryogenic liquid flow through an orifice. In QRA mode, the user no longer needs to input peak overpressure and impulse values that were calculated separately; rather, the unconfined overpressure is estimated for the given system inputs, leak size, and occupant location. The orifice flow model now solves for the maximum mass flux through the orifice at constant entropy while conserving energy, which does not require a direct speed of sound calculation. This does not affect the mass flow for all-gaseous releases; the method results in the same speed of sound for choked flow. However, this method does result in a higher (and more realistic) mass flow rate for a given leak size for liquid releases than was previously calculated.

08 HYDROGEN↗

WSF B696R Calcs

This calculation is applied to the accident analysis scenario of a limited combustibles fire breaching eight SWBs in B696R R1010. For a fire in a building with no breaches, there is only a ground release. The source term (ST) of the deflagration is determined by the Waste Storage Facilities Documented Safety Analysis (Ref. 1). The doses from the release are calculated by using MACCS2 (Ref. 2). This software take hourly meteorological data for a year as input. There are 8760 hours in a year. MACCS2 calculates a dose for each of the 8760 hours, taking into account the associated source term from Reference 1, the wind speed, the stability class (i.e., A through F), the directional sector of the wind (with associated distance to the site boundary). For each directional sector (i.e., 1 through 16) a MACCS2 run was performed. From the total collection of MACCS2 output files, Microsoft Excel is used to extract the dose that correspond to the meteorological conditions of each hour in the year. Note: although MACCS2 inputs a single year of meteorological data, five years are used (2010 through 2014) by performing multiple runs. This is discussed in Section 2.2. Conclusions: The final 95th percentile dose at the collocated worker used for accident analysis of a limited combustibles fire breaching eight SWBs in B696R R1010 is 18.4 rem.

99 GENERAL AND MISCELLANEOUS↗

BayoTech Risk and Modeling Support

This white paper describes the work performed by Sandia National Laboratories in the New Mexico Small Business Agreement with BayoTech. BayoTech is a hydrogen generation and distribution company that is located in Albuquerque, NM. Their goal is to distribute hydrogen via their hydrogen systems which utilize the core design that was developed by Sandia. However, because the hydrogen economy is in its nascency, the safety and operation of the generating systems require independent validation. Additionally, in their pursuit of permitting at various locations around the nation, they require fire protection engineering support in discussions with local fire marshals and neighboring industrial entities. Sandia National Laboratories has subject matter expertise in hydrogen risk modeling of consequence (overpressure and dispersion) as well as fire protection engineering. Throughout this project, Sandia has worked with BayoTech to provide our expertise in these subject areas to facilitate the market entry of their hydrogen generation project to address the dire need for decarbonization due to climate change. The general approach of the support by Sandia is outlined in the main body, while the location specific evaluation for the Port of Stockton is contained in Appendix A.

08 HYDROGEN↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers'’ for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field's Metal eutectic alloy with a melting point of 62°C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions. It is recommended that glass vessels of various volumes ranging from 125 mL to 1 gallon with modified tops containing the specified Field's Metal eutectic alloy which are appropriately designed to avoid flashing spray material releases be added to the DSA container list. These vessels will be utilized in the Shielded Cells for the storage of radioactive liquid samples of sludge slurries. Use of these vessels will also be advantageous for other liquid samples containing accountable amounts of nuclear material throughout other SRNL laboratories. Similarly constructed paraffin vessel lids could also potentially be added to the approved list, though additional testing would be required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 5.0 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, natural gas, and autogas systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying leak sizes and rates, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards, and to provide developed models in a publicly-accessible toolkit usable by all stakeholders. This document provides a description of the methodology and models contained in HyRAM+ version 5.0. The most significant change for HyRAM+ version 5.0 from HyRAM+ version 4.1 is the ability to model blends of different fuels. HyRAM+ was previously only suitable for use with hydrogen, methane, or propane, with users having the ability to use methane as a proxy for natural gas and propane as a proxy for autogas/liquefied petroleum gas. In version 5.0, real natural gas or autogas compositions can be modeled as the fuel, or even blends of natural gas with hydrogen. These blends can be used in the standalone physics models, but not yet in the quantitative risk assessment mode of HyRAM+.

03 NATURAL GAS↗

Grid Resilient, Self-Powered, Fuel Flexible, High Efficiency Heating System (Final Report)

The Grid Independent High Efficiency System (GIHES) delivers a heating system that operates free from the power grid and provides ultra-low emissions and high efficiency heating for residential and commercial buildings. The project demonstrated two weeks of continuous grid independent operation of a storage water heater equipped with a powered damper. The Thermoelectric Generator (TEG) integrated GIHES technology revolutionizes heating systems to provide grid resilient hot water production, while delivering significant value to the end user by eliminating impacts of power interruption and enhancing comfort, convenience and productivity. The system maximizes the thermal-to-electric conversion efficiency by optimizing location and orientation of the TEGs and durability while lowering system costs. The TEGs generate enough power to charge a battery and run the storage water heater unit with a powered damper uninterrupted by providing the required parasitic electrical power for start-up, shutdown and during idling. Several TEGs were analytically and experimentally evaluated based on the size, surface area and the power being generated before designing and fabricating a complete multi-TEG assembly for integration with the water heater. The GIHES technology can be extended to boilers, furnaces and tankless water heaters and integrated with heat pump to further increase the overall equipment efficiency. The technology has the potential to reduce the amount of dispatch power and peak power plant operation. An advanced burner was designed, developed and 3D printed for fuel flexible operation. The burner was designed to enable tighter integration with TEGs for potentially higher TEG output, should this be necessary. A bench-scale test rig to perform testing of a 200,000 Btu/h burner and capable of handling up to 10% H2 (by volume) was setup at GTI’s laboratory with appropriate safety and controls to ensure smooth and safe operation. Testing of the 3D burner showed < 5 ppm NOx emissions can be achieved for the entire firing range and with different levels of hydrogen blends with natural gas. The burner will enable a more integrated TEG-burner module design for improved system performance, should this be required in the future. Techno-economic analysis (TEA) of the TEG integrated with the water heaters was performed. The testing data and the power output were used to develop the TEA. The analysis for the storage unit with damper showed that the TEG integrated system costs $95. This is much lower than a one-time charge needed to wire and install dedicated power. Discussions with TEG manufacturers and OEM’s will provide more detailed information and methods to further lower these costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 5.1 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, natural gas, and autogas systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying leak sizes and rates, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards, and to provide developed models in a publicly-accessible toolkit usable by all stakeholders. This document provides a description of the methodology and models contained in HyRAM+ version 5.1. The most significant changes for HyRAM+ version 5.1 from HyRAM+ version 5.0 are updated default leak frequency values for propane, new default component counts for different fuel types, and an improved fuel specification view in the graphical user interface.

02 PETROLEUM↗

Compressible battery foams to prevent cascading thermal runaway in Li-ion pouch batteries

Lithium-ion battery packs require thermal management to achieve optimum life and safety. This is becoming crucial for battery packs composed of high-energy-density cells. Pouch cells themselves achieve highest packaging efficiency but require additional structural support and thermal management when grouped into modules, especially under abusive conditions such as thermal runaway. Novel foam battery pads have demonstrated to cushion volume changes of pouch cells and are reengineered in this study to mitigate cell-to-cell thermal runaway propagation. The compressible pads are made of polyurethane foams incorporating flame-retardant additives or coatings, including intumescent and fire wall materials. Here their performances were evaluated by conducting nail penetration tests on modules composed of pouch cells at 100% state of charge (SOC), with the foams placed in between the cells. Experimental results show cascading thermal runaway was considerably delayed by polyurethane foams incorporating flame-retardant additives or coatings. Complete prevention of cascading failure was achieved with dense polyurethane foams with multilayered coatings of both fire wall and intumescent materials.

25 ENERGY STORAGE↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers” for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field’s Metal eutectic alloy with a melting point of 62 °C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Fireproof, Lightweight, Polymer–Polymer Solid-State Electrolyte for Safe Lithium Batteries

Safety issues in lithium-ion batteries have raised serious concerns due to their ubiquitous utilization and close contact with the human body. Replacing flammable liquid electrolytes, solid-state electrolytes (SSEs) is thought to address this issue as well as provide unmatched energy densities in Li-based batteries. However, among the most intensively studied SSEs, polymeric solid electrolyte and polymer/ceramic composites are usually flammable, leaving the safety issue unattended. Here, we report the first design of a fireproof, ultralightweight polymer–polymer SSE. The SSE is composed of a porous mechanic enforcer (polyimide, PI), a fire-retardant additive (decabromodiphenyl ethane, DBDPE), and a ionic conductive polymer electrolyte (poly(ethylene oxide)/lithium bis(trifluoromethanesulfonyl)imide). The whole SSE is made from organic materials, with a thin, tunable thickness (10–25 μm), which endorse the energy density comparable to conventional separator/liquid electrolytes. The PI/DBDPE film is thermally stable, nonflammable, and mechanically strong, preventing Li–Li symmetrical cells from short-circuiting after more than 300 h of cycling. LiFePO 4 /Li half cells with our SSE show a high rate performance (131 mAh g –1 at 1 C) as well as cycling performance (300 cycles at C/2 rate) at 60 °C. Most intriguingly, pouch cells made with our polymer–polymer SSE still functioned well even under flame abuse tests.

25 ENERGY STORAGE↗

A Comprehensive Numerical and Experimental Study for the Passive Thermal Management in Battery Modules and Packs

Cooling plates in battery packs of electric vehicles play critical roles in passive thermal management systems to reduce risks of catastrophic thermal runaway. In this work, a series of numerical simulations and experiments are carried out to unveil the role of cooling plates (both between cells and a bottom plate parallel to the cell stack) on the thermal behavior of battery modules and packs under nail penetrations. First, we investigated the role of side cooling plates on the thermal runaway propagation mitigation in battery modules (1S3P) and packs (3S3P) by varying the key parameters of the side cooling plates, such as plate thicknesses, thermal contact resistances, and materials. Then, three important factors for passive thermal management systems are identified: (i) thermal mass of side cooling plates, (ii) interfacial thermal contact resistances, and (iii) the effective heat transfer coefficients at exterior surfaces. The roles of bottom cooling plates on thermal runaway propagation mitigation in 1S3P and 1S5P battery modules are numerically investigated by comparing the thermal behavior of the modules with only side cooling plates and with both side and bottom cooling plates.

25 ENERGY STORAGE↗

Radiation Hardened Foam Cold Test Plan – Phase-I: Foam Adhesion, Contamination Fixation, Moisture Stresses, Pipe Cutting, and Thermal Profile Testing

This document outlines the Phase-I test objectives and implementation plan for a down-selective foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of an intumescent, fire-retardant foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed in FIU’s Outdoor Test and Evaluation Facility using a mock-up that replicates the operational conditions at the proposed hot test location at F/H labs. Results from the cold test plan will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the site and transported to a proper disposal facility. Phase-I testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of foam fixative in piping, (2) evaluation of the adhesion of the foam fixative in piping under varying moisture conditions, (3) determination of the heat profile of the foam fixative during curing, (4) determination of the relationship between pipe diameter and foam fixative quantity, (5) determination of the internal pipe pressure after foam deployment and curing, (6) development of a leak test standard operating procedure to test for the effectiveness of the foam plug, (7) initiation of a literature review to determine if using a hot tap is a viable method to deliver foam into piping, and (8) initiation of a 10-foot mock up test that will be used in Phase-II cold testing. The cold test will be conducted at FIU and all testing activities will comply with SRNL Conduct of R&D Protocols (SRNL-IM-2020-00019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System Health and Status Reporting is Used to Improve Infrastructure Systems at the Hanford Site - 20449

Reliable physical infrastructure systems are vital to completing the clean-up mission and the start-up and commissioning of new nuclear waste processing facilities at the Hanford Site. Key infrastructure systems at Hanford include water, sewer, and electrical utilities, roads, telecommunications/network systems, and fire systems. All of the infrastructure systems are non-nuclear, General Service systems that are being maintained under formal engineering configuration control and none are specifically credited in any documented safety analysis (DSA). Starting in calendar year 2017, the Hanford Site's infrastructure and services contractor started producing system health and status reports for a total of 15 critical infrastructure systems as means to get a better understanding of each system's health and how it could be improved to ensure better and more reliable service delivery. As the reporting, tracking, and use of the metrics has matured, the number of systems for which reports are being developed has been expanded to a total of 23. Each of the critical infrastructure systems are assigned primary and alternate design authorities that complete qualifications on each assigned system. The design authorities actively manage and maintain configuration control on each of their systems and track metrics associated with availability, maintenance (corrective and preventive), and configuration of the technical baseline. The metrics are based on the principles established in Chapter V of DOE O 420.1C, Facility Safety, [1] and have been tailored as appropriate to each of the key infrastructure systems. An overall assessment of system health is performed and documented on a routine basis (e.g., quarterly). Included in this documentation is a quantitative score for each of the metrics (i.e., availability, maintenance, configuration management) along with results of system walk-downs, description of any permanent design modifications, identification of new or emerging issues and vulnerabilities affecting the system, and an assessment by the design authority of actions necessary to improve the system health score. The overall status scores are calculated using a formula and based on a pre-determined grading scale, a color is assigned for simple presentation. The information gained from developing the reports is being used to (1) assist with making timely and better informed decisions through the use of solid technical bases that are increasing the overall reliability and capabilities of the Site's infrastructure systems as new expense and capital projects in the Reliability Projects Investment Portfolio (RPIP) are prioritized and executed; (2) feed the risk management program, and (3) integrate the technical content of Master Plans that describe the Site's needs for the system and the system's capabilities to meet those future needs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flammable Gas Generation and Control at the Idaho Completion Project Legacy Combustible Gas Generation - 20191

On April 11, 2018, four drums containing transuranic waste at the Idaho National Laboratory underwent over-pressurization, ejecting their lids and spreading radiological waste within a facility. An investigation has found that waste in the drums generated methane gas, which contributed to the event. Subsequent to the investigation, the potential for drums to have methane and other flammable analytes whose concentrations could approach or exceed the lower flammability limit (LFL) and the adequacy of the controls to prevent or mitigate a possible deflagration was evaluated. An extensive review of the historical records was performed to determine how many drums exceed the LFL. The historical record identified a small quantity of drums that exceeded the LFL for xylene, hydrogen, and methane. The primary codified applicable code or standard for handling drums is 29 CFR 1910.120 (j) 'Handling Drums and Containers.' It is used throughout the commercial and government sector. This code is integrated throughout the Fluor Idaho safety management programs and procedures to control the Standard Industrial Hazards (SIHs) associated with drum and container handling. Example requirements include: - Drums and containers are inspected, and their integrity assured prior to being moved. - Site operations are organized to minimize the amount of drum or container movement. - When there is a reasonable possibility of flammable atmospheres being present, material handling equipment and hand tools are of the type to prevent sources of ignition. Drums and containers under pressure, as evidenced by bulging or swelling, are not moved until the cause for excess pressure is determined and appropriate containment procedures have been implemented to protect employees from explosive relief of the drum. Drums which exceed the WIPP FGA limit have NCRs associated with them. Once a drum fails flammable gas sampling, an NCR is initiated. The NCR drives placement into NCR dense pack rows. A standing order drives placement of the FGA failures to a single planer segregation location. These drums are not allowed for further processing or shipment until the NCR has been cleared. Once in the single planer rows, follow-up FGA testing is performed by CCP. The NCR is dispositioned by follow-up sampling occurring after adequate time has been provided for the gas to diffuse through the filter assembly, or, in some cases, the drums are repackaged into additional drums to reduce the source term. To date, the ICP project has performed approximately 1.5 million drums moves without a deflagration event due to combustible gas generation. Flammable gas generation in a transuranic waste drum is not unique to the ICP but is common across the DOE complex. Based on the experience at Idaho, application of industry standards is sufficient to control the risk of drum deflagration due to drum movements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solidification of REDC Organics and Airborne Release Fraction Measurements

The Radiochemical Engineering Development Center (REDC) generates various liquid organic wastes from processing irradiated targets to recover heavy elements. In the past, these organics were discharged to the Oak Ridge National Laboratory (ORNL) liquid low-level waste (LLLW) system, along with the aqueous waste. Because of a reduction in aqueous LLLW from other ORNL generators and an increase in the radionuclide concentration, particularly 238 Pu, in the organic waste stream, the organics can no longer be discharged to the LLLW system. The plan is to solidify the liquid organic waste for disposal as solid debris waste. The documented safety analysis for REDC uses an airborne release fraction of 5 x 10 -4 with a respirable fraction of 0.2 for plutonium and other actinides from packaged solid debris waste during a fire scenario, for an overall airborne release fraction/respirable fraction of 10 -4 . Solidifying the organic liquids, either by using PM-199 Organoclay ® or by grouting, would produce solid waste forms with no free liquid, which should qualify for disposal at the Waste Isolation Pilot Plant. The use of Organoclay would be much simpler to implement inside a hot cell. Granular Organoclay can be added to the organic waste solutions until there is a dry layer on top of the liquid and then allowed to cure for a few hours. Grouting the liquids would require using multiple ingredients and mixing steps. Both methods produced waste forms that trapped cerium, as a surrogate for plutonium, inside the waste, with airborne release fractions during fire scenario tests of well below the 10 -4 limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗