Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

[Quantification and monitoring of vascular resistance in the lower limbs by the Doppler method (animal model)]

The object of this study was to define and validate a non-invasive method of evaluation and monitoring of vascular resistances in the leg. Blood flow velocity was measured by Doppler ultrasound in an animal model (ewe) with similar blood flow characteristics in the lower limb as man and allowing access to the required invasive measurements for validation of the method (pressure and flow). Vascular resistances distal to the measuring point (femoral, for example) were assessed using the resistance index R = D/S, S being the peak systolic deflection and D that of diastolic reflux of the Doppler spectral analysis of flow in the femoral artery. The values and variations of this resistance index were compared with the vascular resistances calculated from measurements of pressure and flow at the point of Doppler sampling and expressed in mmHg/ml/min. Femoral flow was measured by Doppler ultrasound (Doppler-echo), and mean pressure by an arterial catheter introduced into the abdominal aorta. Compression of the lower limb veins induced a venous return resulting in a reduction of cardiac output and femoral flow. During compression, femoral flow decreased by an average of 29% (p < 0.001) although mean pressure and heart rate did not change significantly. The femoral resistance index (Rf) increased by an average of 37.5% (p < 0.01) and vascular resistances increased by 45.9% (p < 0.01). Injection of 1 mg adrenaline induced peripheral vasoconstriction with an increase in blood pressure and a decrease in heart rate and femoral flow.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

Low-Load Resistance Training with Blood Flow Occlusion as a Countermeasure to Disuse Atrophy

Decreases in strength and neuromuscular function are observed following prolonged disuse. Exercise countermeasures to prevent muscle dysfunction during disuse typically involve high intensity resistance training. The purpose of the study is to evaluate the effectiveness of low-load resistance training with a blood flow occlusion to mitigate muscle loss and dysfunction during 30 days of unilateral lower limb suspension (ULLS).

Ploutz-Snyder, L. L.↗

Orifice resistance for ejection into a grazing flow

To explain the decrease in orifice resistance with the addition of grazing flow, the flow from an orifice was modeled by using an inviscid analysis which is valid when the orifice flow total pressure is nearly the same as the free stream grazing flow total pressure. For steady outflow from an orifice into a grazing flow, the orifice flow can enter the main grazing flow in an inviscid manner without generating large eddies to dissipate the kinetic energy of the jet. From the analysis, a simple closed-form solution was developed for the steady resistance for ejection from an orifice into a grazing-flow field. The calculated resistance compare favorably with data for a flow regime where the total pressure difference between the grazing flow and the orifice flow is small.

Baumeister, K. J.↗

Ferroelectric Stirling-Cycle Refrigerator

A Stirling-cycle refrigerator has a three-pump configuration and pumping sequence, in which one pump serves as a compressor. one pump serves as an expander, and one pump serves as a displacer. The pumps are ferroelectrically actuated diaphragm pumps which are coordinated by synchronizing the ferroelectric-actuator voltages in such a way that the net effect of the displacer is to reduce the deleterious effect of dead space; that is, to circulate a greater fraction of the working fluid through the heat exchangers than would be possible by use of the compressor and expander alone. In addition. the displacer can be controlled separately to make the flow of working fluid in the heat exchangers turbulent (to increase the rate of transfer of heat at the cost of greater resistance to flow) or laminar (to decrease the resistance to flow at the cost of a lower heat-transfer rate).

Jalink, Antony, Jr.↗

Global Qualitative Flow-Path Modeling for Local State Determination in Simulation and Analysis

For qualitative modeling and analysis, a general qualitative abstraction of power transmission variables (flow and effort) for elements of flow paths includes information on resistance, net flow, permissible directions of flow, and qualitative potential is discussed. Each type of component model has flow-related variables and an associated internal flow map, connected into an overall flow network of the system. For storage devices, the implicit power transfer to the environment is represented by "virtual" circuits that include an environmental junction. A heterogeneous aggregation method simplifies the path structure. A method determines global flow-path changes during dynamic simulation and analysis, and identifies corresponding local flow state changes that are effects of global configuration changes. Flow-path determination is triggered by any change in a flow-related device variable in a simulation or analysis. Components (path elements) that may be affected are identified, and flow-related attributes favoring flow in the two possible directions are collected for each of them. Next, flow-related attributes are determined for each affected path element, based on possibly conflicting indications of flow direction. Spurious qualitative ambiguities are minimized by using relative magnitudes and permissible directions of flow, and by favoring flow sources over effort sources when comparing flow tendencies. The results are output to local flow states of affected components.

Malin, Jane T.↗

Effects of flows on viscous and resistive MHD stability

In many solar applications the viscosity appears to be more important than resistivity. In order to discuss the instabilities in solar conditions, an idealized configuration is considered in which the plasma is flowing in the z-direction along the magnetic field B sub 0 with a velocity V sub 0. As far as the velocity is concerned two different velocity profiles, with different hydrodynmaic stability properties are discussed. The results are summarized.

Einaudi, Giorgio↗

Neural Control of the Cardiovascular System in Space

During the acute transition from lying supine to standing upright, a large volume of blood suddenly moves from the chest into the legs. To prevent fainting, the blood pressure control system senses this change immediately, and rapidly adjusts flow (by increasing heart rate) and resistance to flow (by constricting the blood vessels) to restore blood pressure and maintain brain blood flow. If this system is inadequate, the brain has a backup plan. Blood vessels in the brain can adjust their diameter to keep blood flow constant. If blood pressure drops, the brain blood vessels dilate; if blood pressure increases, the brain blood vessels constrict. This process, which is called autoregulation, allows the brain to maintain a steady stream of oxygen, even when blood pressure changes. We examined what changes in the blood pressure control system or cerebral autoregulation contribute to the blood pressure control problems seen after spaceflight. We asked: (1) does the adaptation to spaceflight cause an adaptation in the blood pressure control system that impairs the ability of the system to constrict blood vessels on return to Earth?; (2) if such a defect exists, could we pinpoint the neural pathways involved?; and (3) does cerebral autoregulation become abnormal during spaceflight, impairing the body s ability to maintain constant brain blood flow when standing upright on Earth? We stressed the blood pressure control system using lower body negative pressure, upright tilt, handgrip exercise, and cold stimulation of the hand. Standard cardiovascular parameters were measured along with sympathetic nerve activity (the nerve activity causing blood vessels to constrict) and brain blood flow. We confirmed that the primary cardiovascular effect of spaceflight was a postflight reduction in upright stroke volume (the amount of blood the heart pumps per beat). Heart rate increased appropriately for the reduction in stroke volume, thereby showing that changes in heart rate regulation alone cannot be responsible for orthostatic hypotension after spaceflight. All of the astronauts in our study had an increase in sympathetic nerve activity during upright tilting on Earth postflight. This increase was well calibrated for the reduction in stroke volume induced by the upright posture. The results obtained from stimulating the sympathetic nervous system using handgrip exercise or cold stress were also entirely normal during and after spaceflight. No astronaut had reduced cerebral blood flow during upright tilt, and cerebral autoregulation was normal or even enhanced inflight. These experiments show that the cardiovascular adaptation to spaceflight does not lead to a defect in the regulation of blood vessel constriction via sympathetic nerve activity. In addition, cerebral autoregulation is well-maintained. It is possible that despite the increased sympathetic nerve activity, blood vessels did not respond with a greater degree of constriction than occurred preflight, possibly uncovering a limit of vasoconstrictor reserve.

Levine, Benjamin D.↗

Prostaglandin control of renal circulation in the unanesthetized dog and baboon

Effects of indomethacin and meclofenamate, inhibitors of prostaglandin synthesis, were evaluated in the regulation of renal blood flow in conscious and anesthetized dogs and in tranquilized baboons, instrumented with arterial pressure catheters and renal blood flow probes. Indomethacin, 10 mg/kg, did not alter renal blood flow or resistance significantly in the conscious dog. In the anesthetized dog, however, indomethacin caused a reduction in renal blood flow and an elevation of renal vascular resistance. Meclofenamate, 4 mg/kg, reduced renal flow and increased renal vascular resistance in conscious dogs. In conscious dogs and tranquilized primates, indomethacin and meclofenamate reduced the reactive hyperemia in the renal bed. Methoxamine and angiotensin II infused in graded doses induced significantly greater renal vasoconstriction in conscious dogs in the presence of indomethacin. Thus, in the conscious animal, prostaglandins appear to play only a minor part in the control of renal circulation at rest, but they are of greater importance in mediating the renal responses to reactive hyperemia and to vasoconstriction.

Swain, J. A.↗

Engine Hydraulic Stability

An analytical injector model was developed specifically to analyze combustion instability coupling between the injector hydraulics and the combustion process. This digital computer dynamic injector model will, for any imposed chamber of inlet pressure profile with a frequency ranging from 100 to 3000 Hz (minimum) accurately predict/calculate the instantaneous injector flowrates. The injector system is described in terms of which flow segments enter and leave each pressure node. For each flow segment, a resistance, line lengths, and areas are required as inputs (the line lengths and areas are used in determining inertance). For each pressure node, volume and acoustic velocity are required as inputs (volume and acoustic velocity determine capacitance). The geometric criteria for determining inertances of flow segments and capacitance of pressure nodes was set. Also, a technique was developed for analytically determining time averaged steady-state pressure drops and flowrates for every flow segment in an injector when such data is not known. These pressure drops and flowrates are then used in determining the linearized flow resistance for each line segment of flow.

Kesselring, R. C.↗

Effect of the Acceleration of Elongated Bodies of Revolution Upon the Resistance in a Compressible Flow

The problem of the motion of an elongated body of revolution in an incompressible fluid may, as is known, be solved approximately with the aid of the distribution of sources along the axis of the body. In determining the velocity field, the question of whether the body moves uniformly or with an acceleration is no factor in the problem. The presence of acceleration must be taken into account in determining the pressures acting on the body. The resistance of the body arising from the accelerated motion may be computed either directly on the basis of these pressures or with the aid of the so-called associated masses (inertia coefficients). A different condition holds in the case of the motion of bodies in a compressible gas. In this case the finite velocity of sound must be taken into account.

Frankl, F. I.↗

Permeability Measurements in Carbon-Epoxy Composites

To determine the permeability of the composite feedline, that is proposed to be used in the X-33 Reusable Launch Vehicle (RLV), three 8 x 8-in. coupons were constructed. Two of the coupons were layed-up with 4 plies of plain weave prepreg [0/90, plus or minus 45, plus or minus 45, 0/90] and the other one layed-up with 4 plies of unidirectional prepreg [0, 90, 90, 0]. The coupons were vacuumed bagged and cured to manufactures specifications. The coupons were then placed in an apparatus to test for permeability. Nitrogen gas was used to permeate through the coupons at a pressure of 5 psig. A manometer was placed on the opposite side of the coupons and was used to measure the height of the fluid with respect to time. From this data the mass flow rate of the gas could be calculated since the area of the manometer and the density of the gas is known. The results of the test are given. The permeability constant was calculated using Darcy's law, which related the pressure drop, flow rate of the permeating gas and resistance to flow through the coupon created. To put the results into prospective the permeability of sand stone and granite is 1E-15 and 1E-20 respectively.

Zdenek, Michael J.↗

Effect of grazing flow on steady-state resistance of isolated square-edged orifices

Steady state diagnostic testing of an isolated orifice has shown the nature of the interaction between grazing and orifice flow causing the large increase in orifice resistance for both inflow and outflow. A simple inviscid interaction model is developed which uses thin aerofoil theory to account for pressure forces exerted at the interface between the orifice and grazing flow together with a one-dimensional discharge coefficient concept. The effect of grazing flow boundary layer thickness is also included in the model. Resistance measurements for each orifice tested, over a wide range of grazing flow speeds and flow rates, collapse into a single curve when plotted in terms of effective discharge coefficient against orifice to grazing velocity ratio. The correlation curves for inflow and outflow are different. Data for clustered orifices collapse in the same way as those for the single orifice. The effect of boundary layer thickness is compared with model predictions.

Rogers, T.↗

The effect of grazing flow on the steady state resistance of square-edged orifices

A simple inviscid interaction model has been developed which uses thin airfoil theory to account for pressure forces exerted at the interface between the orifice and grazing flow together with a one-dimensional discharge coefficient concept. The effect of grazing flow boundary layer thickness was also included in the model. Resistance measurements for a wide range of grazing flow speeds and orifice flow rates collapse into a single curve when plotted in terms of effective discharge coefficient versus orifice-to-grazing velocity ratio. The correlation curves for inflow and outflow are different. Data for clustered orifices collapse in the same way as the single orifice. The effect of boundary layer thickness is compared with model predictions. The effect of orifice length-diameter ratio is shown to be significant for inflow but negligible for outflow.

Rogers, T.↗