Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluorescent Dyes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Fluorogenic Cell-Based Biosensors for Monitoring Microbes

Fluorogenic cell-based sensor systems for detecting microbes (especially pathogenic ones) and some toxins and allergens are undergoing development. These systems harness the natural signaltransduction and amplification cascades that occur in mast cells upon activation with antigens. These systems include (1) fluidic biochips for automated containment of samples, reagents, and wastes and (2) sensitive, compact fluorometers for monitoring the fluorescent responses of mast cells engineered to contain fluorescent dyes. It should be possible to observe responses within minutes of adding immune complexes. The systems have been shown to work when utilizing either immunoglobulin E (IgE) antibodies or traditionally generated rat antibodies - a promising result in that it indicates that the systems could be developed to detect many target microbes. Chimeric IgE antibodies and rat immunoglobulin G (IgG) antibodies could be genetically engineered for recognizing biological and chemical warfare agents and airborne and food-borne allergens. Genetic engineering efforts thus far have yielded (1) CD14 chimeric antibodies that recognize both Grampositive and Gram-negative bacteria and bind to the surfaces of mast cells, eliciting a degranulation response and (2) rat IgG2a antibodies that act similarly in response to low levels of canine parvovirus.

Curtis, Theresa↗

NASA Tech Briefs, November 2005

Topics covered include: Laser System for Precise, Unambiguous Range Measurements; Flexible Cryogenic Temperature and Liquid-Level Probes; Precision Cryogenic Dilatometer; Stroboscopic Interferometer for Measuring Mirror Vibrations; Some Improvements in H-PDLCs; Multiple-Bit Differential Detection of OQPSK; Absolute Position Encoders With Vertical Image Binning; Flexible, Carbon-Based Ohmic Contacts for Organic Transistors; GaAs QWIP Array Containing More Than a Million Pixels; AutoChem; Virtual Machine Language; Two-Dimensional Ffowcs Williams/Hawkings Equation Solver; Full Multigrid Flow Solver; Doclet To Synthesize UML; Computing Thermal Effects of Cavitation in Cryogenic Liquids; GUI for Computational Simulation of a Propellant Mixer; Control Program for an Optical-Calibration Robot; SQL-RAMS; Distributing Data from Desktop to Hand-Held Computers; Best-Fit Conic Approximation of Spacecraft Trajectory; Improved Charge-Transfer Fluorescent Dyes; Stability-Augmentation Devices for Miniature Aircraft; Tool Measures Depths of Defects on a Case Tang Joint; Two Heat-Transfer Improvements for Gas Liquefiers; Controlling Force and Depth in Friction Stir Welding; Spill-Resistant Alkali-Metal-Vapor Dispenser; A Methodology for Quantifying Certain Design Requirements During the Design Phase; Measuring Two Key Parameters of H3 Color Centers in Diamond; Improved Compression of Wavelet-Transformed Images; NASA Interactive Forms Type Interface - NIFTI; Predicting Numbers of Problems in Development of Software; Hot-Electron Photon Counters for Detecting Terahertz Photons; Magnetic Variations Associated With Solar Flares; and Artificial Intelligence for Controlling Robotic Aircraft.

Source record↗

Characterization of Microbial Communities Found in Bioreactor Effluent

The purpose of this investigation was to examine microbial communities of simulated wastewater effluent from hollow fiber membrane bioreactors collected from the Space Life Science Laboratory and Texas Technical University. Microbes were characterized using quantitative polymerase chain reaction where a total count of bacteria and fungi were determined. The primers that were used to determine the total count of bacteria and fungi were targeted for 16S rDNA genes and the internal transcribed spacer, respectively. PCR products were detected with SYBR Green I fluorescent dye and a melting curve analysis was performed to identify unique melt profiles resulting from DNA sequence variations from each species of the community. Results from both the total bacteria and total fungi count assays showed that distinct populations were present in isolates from these bioreactors. This was exhibited by variation in the number of peaks observed on the melting curve analysis graph. Further analysis of these results using species-specific primers will shed light on exactly which microbes are present in these effluents. Information gained from this study will enable the design of a system that can efficiently monitor microbes that play a role in the biogeochemical cycling of nitrogen in wastewater on the International Space Station to assist in the design of a sustainable system capable of converting this nutrient.

Flowe, Candice↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system's eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware. Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to-noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.

Ellis, Tayera↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system’s eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware.Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.Additionally, topics of what was learned and smaller tasks given at White Sands Test Facility (WSTF) will be discussed. All statements in this paper are newly gained knowledge of what I have learned, observed, and have done while at WSTF.

Ellis, Tayera↗

Handheld Fluorescence Resonance Energy Transfer (FRET)-Aptamer Sensor for Bone Markers

Astronauts lose significant bone mass during lengthy space flights. NASA wishes to monitor this bone loss in order to develop nutritional and exercise countermeasures. Operational Technologies Corporation (OpTech) has developed a handheld device that quantifies bone loss in a spacecraft environment. The innovation works by adding fluorescent dyes and quenchers to aptamers to enable pushbutton, one-step bind-and-detect FRET assays that can be freeze-dried, rehydrated with body fluids, and used to quantify bone loss.

Bruno, John G.↗

Shear Stress Sensing with Elastic Microfence Structures

In this work, elastic microfences were generated for the purpose of measuring shear forces acting on a wind tunnel model. The microfences were fabricated in a two part process involving laser ablation patterning to generate a template in a polymer film followed by soft lithography with a two-part silicone. Incorporation of a fluorescent dye was demonstrated as a method to enhance contrast between the sensing elements and the substrate. Sensing elements consisted of multiple microfences prepared at different orientations to enable determination of both shear force and directionality. Microfence arrays were integrated into an optical microscope with sub-micrometer resolution. Initial experiments were conducted on a flat plate wind tunnel model. Both image stabilization algorithms and digital image correlation were utilized to determine the amount of fence deflection as a result of airflow. Initial free jet experiments indicated that the microfences could be readily displaced and this displacement was recorded through the microscope.

Cisotto, Alexxandra↗

Polyurethane Microparticles for Stimuli Response and Reduced Oxidative Degradation in Highly Porous Shape Memory Polymers

Shape memory polymers (SMPs) have been found to be promising biomaterials for a variety of medical applications; however, the clinical translation of such technology is dependent on tailorable properties such as gravimetric changes in degradation environments. For SMPs synthesized from amino-alcohols, oxidation resulting in rapid mass loss may be problematic in terms of loss of material functionality as well as toxicity and cytocompatibility concerns. Control of gravimetric changes was achieved through the incorporation of small molecule antioxidants, either directly into the polymer matrix or included in microparticles to form a SMP composite material. Direct incorporation of small molecule antioxidants, such as phenolic alcohols, was found to alter shape memory attributes and increase elastic modulus at the expense of the strain to failure. Such changes could not ensure retention of the antioxidants and therefore did not increase oxidative stability. However, the inclusion of antioxidants in microparticles was found to produce materials with similar thermomechanical and shape memory properties while increasing oxidative resistance compared to controls. The microparticle composite SMPs also act as a platform for environmental sensing, such as pH-dependent fluorescence shifts and payload release, as demonstrated by fluorescent dyes and the release of antioxidants. The use of polyurethane-urea microparticles in porous SMPs is demonstrated to increase biostability of the materials, by approximately 25%, and ultimately extend their lifespan for use in aneurysm occlusion as determined through calculated in vivo degradation rates corresponding to a porcine aneurysm environment.

Weems, A. C.↗

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E. Z. Klier↗

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E Z Klier↗

Rhodol fluorophores for near-infrared imaging

The present disclosure encompasses embodiments of a novel near-infrared-emitting molecular fluorophore and probes incorporating said fluorophore advantageous for in vitro and in vivo research studies. The fluorophore is robust, photostable, and possesses functionalities for easy bioorthogonal conjugation (e.g., click chemistry, hydrazone formation, Diels Alder, Staudinger ligation, etc.). It is biocompatible and emits at 711 nm in aqueous conditions. These fluorophores may be used to fluorescently tag biological molecules or structures of interest, or used as optical reporters (i.e., activatable molecular probes, fluorescent dyes) for specific biomarkers/analytes as they can be switched from “off” to “on.” This fluorophore is useful for cellular assays and preclinical small animal imaging as the near-infrared emission is highly penetrating, and the photophysical properties are outstanding. As such, the properties of this class of fluorophores could easily be translated for use in clinical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BERYLLIUM DETECTION BY FLUORESCENT SPECTROSCOPY

Facilities that machine and process materials involving beryllium oxide are hazardous to workers safety and require monitoring of contamination. A primary goal in industrial worker safety in beryllium containing facilities is avoiding inhalation, which may cause chronic beryllium disease (CBD). Decontamination is labor intensive due to the miniscule size of beryllium dust and the difficulty of detecting its presence on surfaces. Current methods of beryllium detection, while successful, involve numerous intermediate steps such as obtaining wipe samples, applying buffers, centrifuging with ammonium bifluoride, additives to reduce influence of other competing metal ions, and require potentially long wait times of around 24 hours for a single surface sample. In some cases, these samples must be sent to testing facilities across the country and results may not be available for days. Therefore, for the purposes of this study, it has been deemed important to test new fluorescent dyes that can rapidly produce a beryllium presence confirmation via application spray.

61 RADIATION PROTECTION AND DOSIMETRY↗

Defect-resistant plastic scintillators with aliphatic additives

A plastic scintillator includes a polymer matrix, an aliphatic additive present in the polymer matrix in an effective amount to impart fog resistance to the plastic scintillator, and at least one fluorescent dye in the polymer matrix, the dye being effective to provide scintillation upon exposure to radiation. The effective amount of the aliphatic additive is in a range of greater than 0 weight percent up to 5 weight percent relative to the total weight of the plastic scintillator. Moreover, the aliphatic additive has a structure comprising up to 300 repeat units.

Mabe, Andrew Neil↗

Methods for ultraviolet excitation microscopy of biological surfaces

Microscopy with Ultraviolet Surface Excitation (MUSE) for use in the classroom to enhance life sciences education and curricula, or for other applications, including without limtiation the operating room, other medical environments, research environments, and low resource environments. MUSE's suitability is based on multiple key factors including its simplicity of use, the incorporation of inexpensive hardware including LED illumination, and very basic tissue preparation. The ultraviolet excitation acts as passive optical sectioning confining the generated fluorescence signal to only a few micrometers below the tissue surface thus eliminating the out of focus signals. This facilitates image capture of tissue microstructure and organization from specimens at the intact or sliced surface arising from varying fluorophore concentration within the different cellular compartments. Although just the tissue auto fluorescence maybe used, image quality is enhanced with brief application of nontoxic fluorescent dyes to selectively highlight cellular compartments. Sample preparation is safe, efficient and familiar to students with basic chemistry or biology lab experience. Mixed-dye powders may be used to simplify translation of this method for educational, medical, research, low resource, and other settings.

Demos, Stavros G.↗

Penetrant-Indication-Measuring Compass

Modified drafting compass well suited to measurement of length of crack or width of area stained by penetrant-dye-inspection method. Equipped with any of variety of standard curved or straight pointed tips. Modification consists in coating tips with dye that fluoresces light pink under same ultraviolet inspection light causing penetrant dye to fluoresce yellow green. Used in locations inaccessible to conventional fluorescent comparator. Eliminates errors of optical distortion in comparator, also eliminates errors of interpolation.

Schaefer, Lloyd↗

Cyanine-Incorporated Amorphous Polymeric Carbon Dots for Optical Reactive Oxygen Species Sensing

Reactive oxygen species (ROS) are common cellular oxidants that when overproduced by cellular stressors cause harm to cells. Detection of ROS is of utmost importance to understanding a wide variety of cellular function and toxicity mechanisms. Conventional ROS fluorescence assays involve using a single dye to visualize the ROS quantity. Herein, we describe ROS-sensitive, fluorescent-dye-incorporated carbon dots with dual fluorescence capabilities and good biocompatibility. Carbon dots (CDs) made of citric acid and urea were synthesized with incorporated cyanine-3-amine (Cy3), a bright red fluorescent dye, to create Cy3-CDs. Additionally, to get Cy3 into the ROS-sensitive form, this work demonstrated that Cy3 alone and Cy3 within carbon dots can be electrochemically reduced to their colorless ROS-sensitive form. Cy3, CDs, and Cy3-CDs are all responsive to additions of superoxide, leading to an increase in the fluorescence. Overall, this work examines how O 2 •– and additional oxidizers interact with CDs, Cy3, and Cy3-CDs, and molecular-level hypotheses are explored that will inform the design of future carbon dot-based ROS sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Species-specific ribosomal RNA-FISH identifies interspecies cellular-material exchange, active-cell population dynamics and cellular localization of translation machinery in clostridial cultures and co-cultures

ABSTRACT The development of synthetic microbial consortia in recent years has revealed that complex interspecies interactions, notably the exchange of cytoplasmic material, exist even among organisms that originate from different ecological niches. Although morphogenetic characteristics, viable RNA and protein dyes, and fluorescent reporter proteins have played an essential role in exploring such interactions, we hypothesized that ribosomal RNA-fluorescence in situ hybridization (rRNA-FISH) could be adapted and applied to further investigate interactions in synthetic or semisynthetic consortia. Despite its maturity, several challenges exist in using rRNA-FISH as a tool to quantify individual species population dynamics and interspecies interactions using high-throughput instrumentation such as flow cytometry. In this work, we resolve such challenges and apply rRNA-FISH to double and triple co-cultures of Clostridium acetobutylicum, Clostridium ljungdahlii, and Clostridium kluyveri . In pursuing our goal to capture each organism’s population dynamics, we demonstrate dynamic rRNA, and thus ribosome, exchange between the three species leading to the formation of hybrid cells. We also characterize the localization patterns of the translation machinery in the three species, identifying distinct, dynamic localization patterns among them. Our data also support the use of rRNA-FISH to assess the culture’s health and expansion potential, and, here again, our data find surprising differences among the three species examined. Taken together, our study argues for rRNA-FISH as a valuable and accessible tool for quantitative exploration of interspecies interactions, especially in organisms which cannot be genetically engineered or in consortia where selective pressures to maintain recombinant species cannot be used. IMPORTANCE Though dyes and fluorescent reporter proteins have played an essential role in identifying microbial species in co-cultures, we hypothesized that ribosomal RNA-fluorescence in situ hybridization (rRNA-FISH) could be adapted and applied to quantitatively probe complex interactions between organisms in synthetic consortia. Despite its maturity, several challenges existed before rRNA-FISH could be used to study Clostridium co-cultures of interest. First, species-specific probes for Clostridium acetobutylicum and Clostridium ljungdahlii had not been developed. Second, “state-of-the-art” labeling protocols were tedious and often resulted in sample loss. Third, it was unclear if FISH was compatible with existing fluorescent reporter proteins. We resolved these key challenges and applied the technique to co-cultures of C. acetobutylicum , C. ljungdahlii , and Clostridium kluyveri . We demonstrate that rRNA-FISH is capable of identifying rRNA/ribosome exchange between the three organisms and characterized rRNA localization patterns in each. In combination with flow cytometry, rRNA-FISH can capture sub-population dynamics in co-cultures.

Hill, John D.↗