Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluorescent probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

RBE of Energetic Iron Ions for the Induction of Early and Late Chromosome Aberrations in Different Cell Types

Numerous published studies have reported the RBE values for chromosome chromosomes induced by charged particles of different LET. The RBE for chromosome aberrations in human lymphocytes exposed ex vivo showed a similar relationship as the quality factor for cancer induction. Consequently, increased chromosome aberrations in the astronauts' white blood cells post long-duration missions are used to determine the biological doses from exposures to space radiation. The RBE value is known to be very different for different types of cancer. Previously, we reported that the RBE for initial chromosome damages was high in human lymphocytes exposed to Fe ions. After multiple cell divisions post irradiation, the RBE was significantly smaller. To test the hypothesis that the RBE values for chromosome aberrations are different between early and late damages and also different between different cell types, we exposed human lymphocytes ex vivo, and human fibroblast cells and human mammary epithelial cells in vitro to 600 MeV/u Fe ions. Post irradiation, the cells were collected at first mitosis, or cultured for multiple generations for collections of remaining or late arising chromosome aberrations. The chromosome aberrations were quantified using fluorescent in situ hybridization (FISH) with whole chromosome specific probes. This study attempts to offer an explanation for the varying RBE values for different cancer types.

Zhang, Ye↗

Simultaneous measurements of velocity, temperature, and pressure using rapid CW wavelength-modulation laser-induced fluorescence of OH

The beam from a rapid-tuning single-frequency laser was used to probe the R1(7) and R1(11) A2Sigma(+) - X2Pi(0,0) line pair of OH at a 45-deg incident angle in a combustion-driven, supersonic free jet. Absorption line shapes were recorded in spatially resolved, single-point fluorescence. The Doppler shift, intensity ratio, and collisional broadening of the measured line pair were used to determine velocity, temperature, and pressure. The repetition rate of the measurement was 3 kHz.

Chang, A. Y.↗

Biodosimetry results from space flight Mir-18

Astronauts are classified as radiation workers due to the presence of ionizing radiation in space. For the assessment of health risks, physical dosimetry has been indispensable. However, the change of the location of dosimeters on the crew members, the variation in dose rate with location inside the spacecraft and the unknown biological effects of microgravity can introduce significant uncertainties in estimating exposure. To circumvent such uncertainty, a study on the cytogenetic effects of space radiation in human lymphocytes was proposed and conducted for Mir-18, a 115-day mission. This study used fluorescence in situ hybridization (FISH) with whole-chromosome painting probes to score chromosomal exchanges and the Giemsa staining method to determine the frequency of dicentrics. The growth kinetics of cells and sister chromatid exchanges (SCEs) were examined to ensure that chromosomal aberrations were scored in the first mitosis and were induced primarily by space radiation. Our results showed that the frequency of chromosomal aberrations increased significantly in postflight samples compared to samples drawn prior to flight, and that the frequency of SCEs was similar for both pre- and postflight samples. Based on a dose-response curve for preflight samples exposed to gamma rays, the absorbed dose received by crew members during the mission was estimated to be about 14.75 cSv. Because the absorbed dose measured by physical dosimeters is 5.2 cGy for the entire mission, the RBE is about 2.8.

NASA Discipline Radiation Health↗

Accuracy Of Hot-Wire Anemometry In Supersonic Turbulence

Sensitivity of hot-wire probe compared to laser-induced-florescence measurements. Report discusses factors affecting readings of hot-wire anemometer in turbulent supersonic boundary layer. Presents theoretical analysis of responses of hot-wire probe to changes in flow; also compares measurements by hot-wire probe with measurements of same flows by laser-induced fluorescence (LIF). Because LIF provides spatially and temporally resolved data on temperature, density, and pressure, provides independent means to determine responses of hot-wire anemometers to these quantities.

Logan, Pamela↗

Phylogenetic perspective and the search for life on earth and elsewhere

Any search for microbial life on Mars cannot rely upon cultivation of indigenous organisms. Only a minority of even terrestrial organisms that are observed in mixed, naturally-occurring microbial populations can be cultivated in the laboratory. Consequently, methods are being developed for analyzing the phylogenetic affiliations of the constituents of natural microbial populations without the need for their cultivation. This is more than an exercise in taxonomy, for the extent of phylogenetic relatedness between unknown and known organisms is some measure of the extent of their biochemical commonalities. In one approach, total DNA is isolated from natural microbial populations and 16S rRNA genes are shotgun cloned for rapid sequence determinations and phylogenetic analyses. A second approach employs oligodeoxynucleotide hybridization probes that bind to phylogenetic group-specific sequences in 16S rRNA. Since each actively growing cell contains about 104 ribosomes, the binding of the diagnostic probes to single cells can be visualized by radioactivity or fluorescence. The application of these methods and the use of in situ cultivation techniques is illustrated using submarine hydrothermal vent communities. Recommendations are made regarding planning toward future Mars missions.

Pace, Norman R.↗

H2/O2 three-body rates at high temperatures

Hydrogen atoms are produced in the presence of excess O2, and the first-order decay are studied as a function of temperature and pressure in order to obtain the rate coefficient for the three-body reaction between H-atoms and O2. Attention is focused on the kinetic scheme employed as well as the reaction cell and photolysis and probe laser system. A two-photon laser-induced fluorescence technique is employed to detect H-atoms without optical-thickness or O2-absorption problems. Results confirm measurements reported previously for the H + O2 + N2 reaction at 300 K and extend these measurements to higher temperatures. Preliminary data indicate non-Arrehenius-type behavior of this reaction rate coefficient as a function of temperature. Measurements of the rate coefficient for H + O2 + Ar reaction at 300 K give a rate coefficient of 2.1 +/- 0.1 x 10 to the -32nd cm exp 6/molecule sec.

Marinelli, William J.↗

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This work seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the biosensors. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as exposure to radiation. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), and reporting agents. The reporting will be accomplished through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation. These nanosensors could facilitate the success and increase the safety of extended space flight. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. This period, synthesis of the test-bed biosensors continued. Studies were performed on the candidate fluorescent dyes to determine which might be suitable for the biosensor under development. Development continued on producing an artificial capillary bed as a tool for the use in the production of the fluorescence signal monitor. Work was also done on the in vitro multispectral analysis system, which uses the robotic microscope.

Baker, James R.↗

Nitric Oxide Planar Laser Induced Fluorescence Rotational Thermometry Characterization of A Hypersonic Boundary Layer

Nitric oxide (NO) planar laser-induced fluorescence (PLIF) was performed to determine rotational temperature profiles and fluctuations within a hypersonic boundary layer above the surface of a 2.75° half-angle wedge. The experiments were performed in the Texas A&M University Actively Controlled Expansion (ACE) hypersonic blow-down wind tunnel at Mach = 5.7 and 𝑅𝑒 = 6 × 10 6 /m. The NO was introduced to the flow in the settling chamber of the ACE tunnel and probed using two laser sheets near 226 nm. The resulting NO PLIF fluorescence signal was acquired using in-house software, which simultaneously recorded tunnel conditions. After a Fast Fourier Transform (FFT) blurring and statistical treatment was performed, the preshock temperature was evaluated to be 58 ± 2 K (3.5%), while the turbulent boundary layer temperature near the wall was found to be 350 K with fluctuations on the order of ±25 K (7%). The relative temperature fluctuations were determined to be 3 − 5% in the freestream and peaked at 33% in the turbulent boundary layer. The advantages and disadvantages of seeding NO in the tunnel settling chamber for thermometric PLIF measurements are discussed.

Hypersonics↗

NO PLIF Rotational Thermometry Characterization of a Hypersonic Boundary Layer

Nitric oxide (NO) planar laser-induced fluorescence (PLIF) was performed to determine rotational temperature profiles and fluctuations within a hypersonic boundary layer above the surface of a 2.75° half-angle wedge. The experiments were performed in the Texas A&M University Actively Controlled Expansion (ACE) hypersonic blow-down wind tunnel at Mach = 5.7 and 𝑅𝑒 = 6 × 10 6 /m. The NO was introduced to the flow in the settling chamber of the ACE tunnel and probed using two laser sheets near 226 nm. The resulting NO PLIF fluorescence signal was acquired using in-house software, which simultaneously recorded tunnel conditions. After a Fast Fourier Transform (FFT) blurring and statistical treatment was performed, the preshock temperature was evaluated to be 58 ± 2 K (3.5%), while the turbulent boundary layer temperature near the wall was found to be 350 K with fluctuations on the order of ±25 K (7%). The relative temperature fluctuations were determined to be 3 − 5% in the freestream and peaked at 33% in the turbulent boundary layer. The advantages and disadvantages of seeding NO in the tunnel settling chamber for thermometric PLIF measurements are discussed.

Hypersonics↗

Biological dosimetry by interphase chromosome painting

Both fluorescence in situ hybridization of metaphase spreads with whole-chromosome probes and premature chromosome condensation in interphase nuclei have been used in the past to estimate the radiation dose to lymphocytes. We combined these techniques to evaluate the feasibility of using painted interphase chromosomes for biodosimetry. Human peripheral lymphocytes were exposed to gamma rays and fused to mitotic Chinese hamster cells either immediately after irradiation or after 8 h incubation at 37 degrees C. Interphase or metaphase human chromosomes were hybridized with a composite probe specific for human chromosomes 3 and 4. The dose-response curve for fragment induction immediately after irradiation was linear; these results reflected breakage frequency in the total genome in terms of DNA content per chromosome. At 8 h after irradiation, the dose-response curve for chromosome interchanges, the prevalent aberration in interphase chromosomes, was linear-quadratic and similar to that observed for metaphase chromosomes. These results suggest that painting prematurely condensed chromosomes can be useful for biological dosimetry when blood samples are available shortly after the exposure, or when interphase cells are to be scored instead of mitotic cells.

NASA Discipline Radiation Health↗

Selective functionalization of carbon nanotube tips allowing fabrication of new classes of nanoscale sensing and manipulation tools

Embodiments in accordance with the present invention relate to techniques for the growth and attachment of single wall carbon nanotubes (SWNT), facilitating their use as robust and well-characterized tools for AFM imaging and other applications. In accordance with one embodiment, SWNTs attached to an AFM tip can function as a structural scaffold for nanoscale device fabrication on a scanning probe. Such a probe can trigger, with nanometer precision, specific biochemical reactions or conformational changes in biological systems. The consequences of such triggering can be observed in real time by single-molecule fluorescence, electrical, and/or AFM sensing. Specific embodiments in accordance with the present invention utilize sensing and manipulation of individual molecules with carbon nanotubes, coupled with single-molecule fluorescence imaging, to allow observation of spectroscopic signals in response to mechanically induced molecular changes. Biological macromolecules such as proteins or DNA can be attached to nanotubes to create highly specific single-molecule probes for investigations of intermolecular dynamics, for assembling hybrid biological and nanoscale materials, or for developing molecular electronics. In one example, electrical wiring of single redox enzymes to carbon nanotube scanning probes allows observation and electrochemical control over single enzymatic reactions by monitoring fluorescence from a redox-active cofactor or the formation of fluorescent products. Enzymes ''nanowired'' to the tips of carbon nanotubes in accordance with embodiments of the present invention, may enable extremely sensitive probing of biological stimulus-response with high spatial resolution, including product-induced signal transduction.

Wade, Lawrence A.↗

Planar Imaging of Hydroxyl in a High Temperature, High Pressure Combustion Facility

An optically accessible flame tube combustor is described which has high temperature, pressure, and air flow capabilities. The windows in the combustor measure 3.8 cm axially by 5.1 cm radially, providing 67 percent optical access to the square cross section flow chamber. The instrumentation allows one to examine combusting flows and combustor subcomponents, such as fuel injectors and air swirlers. These internal combustor subcomponents have previously been studied only with physical probes, such as temperature and species rakes. Planar laser-induced fluorescence (PLIF) images of OH have been obtained from this lean burning combustor burning Jet-A fuel. These images were obtained using various laser excitation lines of the OH A yields X (1,0) band for two fuel injector configurations with pressures ranging from 1013 kPa (10 atm) to 1419 kPa (14 atm), and equivalence ratios from 0.41 to 0. 59. Non-uniformities in the combusting flow, attributed to differences in fuel injector configuration, are revealed by these images.

Hicks, Yolanda R.↗

Estimate of the frequency of true incomplete exchanges in human lymphocytes exposed to 1 GeV/u Fe ions in vitro

PURPOSE: To study the frequency of true incomplete exchanges induced by high-LET radiation. MATERIALS AND METHODS: Human lymphocytes were exposed to 1 GeV/u Fe ions (LET = 140 keV/microm). Chromosome aberrations were analysed by a fluorescence in situ hybridization using a combination of whole-chromosome-specific probes and human telomere probes. Chromosomes 1, 3 and 4 were investigated. RESULTS: The percentage of incomplete exchanges was between 23 and 29% if telomere signals were not considered. The percentage decreased to approximately 10% after ruling out false incomplete exchanges containing telomere signals. The final estimation of true incomplete exchanges was <10%. CONCLUSION: Within a degree of uncertainty, the percentage of true incomplete exchanges in 1 GeV/u Fe ion-irradiated human lymphocytes was similar to that induced by gamma rays.

NASA Center JSC↗

Induction of chromosome aberrations in human cells by charged particles

Chromosome aberrations induced by high-energy charged particles in normal human lymphocytes and human fibroblasts have been investigated. The charged particles included 250 MeV/nucleon protons, 290 MeV/nucleon carbon ions and 1 GeV/nucleon iron ions. The energies of the charged particles were higher than in most of the studies reported in the literature. Lymphocytes were stimulated to grow immediately after irradiation, while fibroblasts were incubated at 37 degrees C for 24 h for repair. Chromosomes were collected at the first mitosis after irradiation and chromosome aberrations were scored using the fluorescence in situ hybridization (FISH) technique with a whole-chromosome 4 probe. Chromosome aberrations were classified as reciprocal exchanges, incomplete exchanges, deletions and complex exchanges. The relative biological effectiveness (RBE) for each type of aberration was calculated by dividing a dose of 4 Gy by the dose of the charged particles producing the same effect as 4 Gy of gamma rays. Results of this study showed that complex aberrations have the highest RBE for radiation of high linear energy transfer (LET) for human lymphocytes, but for fibroblasts, the greatest effect was for incomplete exchanges. For both lymphocytes and fibroblasts, iron ions induced a similar fraction of aberrant cells.

NASA Center JSC↗

The electrical performance of Ag Zn batteries for the Venus multi-probe mission

An evaluation of 5 Ah and 21 Ah Silver-Zinc batteries was made to determine their suitability to meet the energy storage requirements of the bus vehicle, 3 small probes and large probe for the Venus multi-probe mission. The evaluation included a 4 Ah battery for the small probe, a 21 Ah battery for the large probe, one battery of each size for the bus vehicle power, a periodic cycling test on each size battery and a wet stand test of charged and discharged cells of both cell designs. The study on the probe batteries and bus vehicle batteries included both electrical and thermal simulation for the entire mission. The effects on silver migration and zinc penetration of the cellophane separators caused by the various test parameters were determined by visual and X-ray fluorescence analysis. The 5 Ah batteries supported the power requirements for the bus vehicle and small probe. The 21 Ah large probe battery supplied the required mission power. Both probe batteries delivered in excess of 132 percent of rated capacity at the completion of the mission simulation.

Palandati, C.↗

New Constraints on the Geometry and Kinematics of Matter Surrounding the Accretion Flow in X-Ray Binaries from Chandra High-Energy Transmission Grating X-Ray Spectroscopy

The narrow, neutral Fe Kα fluorescence emission line in X-ray binaries (XRBs) is a powerful probe of the geometry, kinematics, and Fe abundance of matter around the accretion flow. In a recent study it has been claimed, using Chandra High-Energy Transmission Grating (HETG) spectra for a sample of XRBs, that the circumnuclear material is consistent with a solar-abundance, uniform, spherical distribution. It was also claimed that the Fe Kα line was unresolved in all cases by the HETG. However, these conclusions were based on ad hoc models that did not attempt to relate the global column density to the Fe Kα line emission. We revisit the sample and test a self-consistent model of a uniform, spherical X-ray reprocessor against HETG spectra from 56 observations of 14 Galactic XRBs. We find that the model is ruled out in 13/14 sources because a variable Fe abundance is required. In two sources a spherical distribution is viable, but with nonsolar Fe abundance. We also applied a solar-abundance Compton-thick reflection model, which can account for the spectra that are inconsistent with a spherical model, but spectra with a broader bandpass are required to better constrain model parameters. We also robustly measured the velocity width of the Fe Kα line and found FWHM values of up to approx. 5000 km/s. Only in some spectra was the Fe Kα line unresolved by the HETG.

Tzanavaris, P.↗

Optical probing of cold trapped atoms

Transitions between excited states of laser-cooled and laser-trapped rubidium and cesium atoms are probed by use of fiber and diode lasers. High-resolution Doppler-free spectra are detected by observation of the absorption and fluorescence of light from the intermediate level of two-step cascade systems. The optical double-resonance spectra show Autler-Townes splitting in the weak probe limit and more complicated spectra for a strongly coupled three-level system.

Fox, R. W.↗

Laser-Induced Fluorescence Measurements of Energetic Ions in a 100-A LaB6 Hollow Cathode

Increasingly long-duration space missions require a better understanding of the failure mechanisms of hollow cathodes to enable prediction of lifetime. Energetic ions have been measured in the plume of hollow cathodes but the energies are higher than can be explained classically. One of the mechanisms that appears to be contributing to the ion heating is ion acoustic turbulence (IAT), which has been investigated with plasma probes recently at JPL. In this work the ion velocity distribution has been measured using laser-induced fluorescence (LIF) at several high-current operating conditions on the centerline of a 100 A class hollow cathode at JPL. A retarding potential analyzer was (RPA) was used to measure the ion energy profile in the far plume and a Langmuir probe was used to measure electron temperature and plasma potential fluctuations. RPA energies are shown to correlate with the values measured by LIF. The ion temperature is shown to increase with distance downstream of the cathode. A parametric study of the ion heating as a function of discharge current and cathode flow rate was performed. It was found that for increasing current the ion temperature evolution did not vary even though the wave IAT wave energy increased. The effect of flow rate was more pronounced, with higher values reducing both ion temperature and wave energy linearly. These results indicate that IAT is at least partially responsible for energetic ion production in the hollow cathode plume.

Dodson, Christopher A.↗