Space-Based Near-Infrared CO2 Measurements: Testing the Orbiting Carbon Observatory Retrieval Algorithm and Validation Concept Using SCIAMACHY Observations over Park Falls, Wisconsin

Space-based measurements of reflected sunlight in the near-infrared (NIR) region promise to yield accurate and precise observations of the global distribution of atmospheric CO2. The Orbiting Carbon Observatory (OCO) is a future NASA mission, which will use this technique to measure the column-averaged dry air mole fraction of CO2 (XCO2) with the precision and accuracy needed to quantify CO2 sources and sinks on regional scales (approx.1000 x 1000 sq km and to characterize their variability on seasonal timescales. Here, we have used the OCO retrieval algorithm to retrieve XCO2 and surface pressure from space-based Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY) measurements and from coincident ground-based Fourier transform spectrometer (FTS) measurements of the O2 A band at 0.76 mm and the 1.58 mm CO2 band for Park Falls,Wisconsin. Even after accounting for a systematic error in our representation of the O2 absorption cross sections, we still obtained a positive bias between SCIAMACHY and FTS XCO2 retrievals of approx.3.5%. Additionally, the retrieved surface pressures from SCIAMACHY systematically underestimate measurements of a calibrated pressure sensor at the FTS site. These findings lead us to speculate about inadequacies in the forward model of our retrieval algorithm. By assuming a 1% intensity offset in the O2 A band region for the SCIAMACHY XCO2 retrieval, we significantly improved the spectral fit and achieved better consistency between SCIAMACHY and FTS XCO2 retrievals. We compared the seasonal cycle of XCO2 at Park Falls from SCIAMACHY and FTS retrievals with calculations of the Model of Atmospheric Transport and Chemistry/Carnegie-Ames-Stanford Approach (MATCH/CASA) and found a good qualitative agreement but with MATCH/CASA underestimating the measured seasonal amplitude. Furthermore, since SCIAMACHY observations are similar in viewing geometry and spectral range to those of OCO, this study represents an important test of the OCO retrieval algorithm and validation concept using NIR spectra measured from space. Finally, we argue that significant improvements in precision and accuracy could be obtained from a dedicated CO2 instrument such as OCO, which has much higher spectral and spatial resolutions than SCIAMACHY. These measurements would then provide critical data for improving our understanding of the carbon cycle and carbon sources and sinks.

carbon dioxide↗

Airborne Lidar Observations of the Stratosphere After the Pinatubo Eruption

The eruption of Mt. Pinatubo in June 1991 injected the largest mass of gases and ash into the stratosphere observed since lidar and satellite monitoring of the stratosphere became possible in the middle 1960's. Because of early indications of the significance of the eruption, NASA mounted an airborne mission to survey the stratospheric plume soon after the eruption. The NASA Wallops Electra aircraft was outfitted with a depolarization lidar, a correlation spectrometer (for SO2 measurements), a total-direct-diffuse spectral radiometer, and a Fourier transform spectrometer. Six flights were made during the period July 7-14.

Winker, David M.↗

Mesospheric and lower thermospheric winds, temperatures densities, and volume emission rates

This memo has been written to report on the progress made under grant NAG1-1315 and to request a continuation of funding for this work. Our proposal involved a plan to utilize an existing ground-based chain of optical and radar facilities to assemble a comprehensive, long-term, multi-station base of upper-mesospheric and lower thermospheric measurements of neutral winds, temperatures, and volume emission rates that can be used to make comparisons with data from the HRDI and WINDII instruments that are flying aboard the UARS spacecraft. The ground-based, optical data were to be obtained on a routine basis from five geographically separated observatories at: Thule, Greenland; Sondrestrom, Greenland; Watson Lake, Yukon (replacing Calgary, Alberta); Ann Arbor, Michigan; and Maynooth, Eire. Several different optical instruments are present at these sites: the total array of instruments is comprised of five Fabry-Perot interferometers, two half meter Ebert-Fastie spectrometers, one all-sky CCD imager, and a near infra-red Michelson Fourier transform spectrometer. In addition to these optical instruments, data were to be obtained from the incoherent scatter radar at Sondrestrom, Greenland. These radar measurements are comprised of neutral winds, temperatures, and densities from altitudes between approximately 70 - 120 km. The optical measurements are obtained locally from specific altitudes depending on the emission line studied. For example, red line optical data come from about 220 km. In this report we summarize the progress made in obtaining these data and relate it to the specific tasks outlined in the original grant application. These tasks are discussed in the next section. Progress towards their completion is discussed in section three, while future plans and summary are described in section four.

Killeen, Timothy L.↗

Cassini CIRS Observations of Saturn's Rings

In the spring of 2004, during Cassini s approach to Saturn, the Cassini Composite Infrared Spectrometer (CIRS) began acquiring thermal spectra of Saturn s rings. CIRS is a Fourier-transform spectrometer that measures radiation in the thermal infrared from 7 microns to 1 millimeter (1400 to 10/cm). CIRS has a set of 21 detectors, consisting of two 1 x 10 linear arrays with a pixel size of 0.3 mrad, and one 4 mrad circular detector. Just after the completion of the Saturn orbit insertion (SOI) burn, CIRS performed an especially high spatial resolution scan of portions of Saturn s A, B and C rings. In the months following SOI, additional ring measurements have been obtained, including radial scans on the lit and unlit sides of the rings, and azimuthal scans across the shadowed regions of the A, B and C rings.

Spilker, Linda J.↗

New Horizons in Cosmology with Spectral Distortions of the Cosmic Microwave Background

Following the pioneering observations with COBE in the early 1990s, studies of the cosmic mi- crowave background (CMB) have primarily focused on temperature and polarization anisotropies. CMB spectral distortions – tiny departures of the CMB energy spectrum from that of a perfect blackbody – provide a second, independent probe of fundamental physics, with a reach deep into the primordial Universe. The theoretical foundation of spectral distortions has seen major advances in recent years, highlighting the immense potential of this emerging field. Spectral distortions probe a fundamental property of the Universe – its thermal history – thereby providing additional insight into processes within the cosmological standard model(I) (CSM) as well as new physics beyond. Spectral distortions are an important tool for understanding inflation and the nature of dark matter. They shed new light on the physics of recombination and reionization, both prominent stages in the evolution of our Universe, and furnish critical information on baryonic feedback processes, in addition to probing primordial correlation functions at scales inaccessible to other tracers. In principle the range of signals is vast: many orders of magnitude of discovery space can be explored by detailed observations of the CMB energy spectrum. Several CSM signals are predicted and provide clear experimental targets that are observable with present-day technology. Confirmation of these signals would extend the reach of the CSM by orders of magnitude in physical scale as the Universe evolves from the initial stages to its present form. Their absence would pose a huge theoretical challenge, immediately pointing to new physics. Here, we advocate for a dedicated effort to measure CMB spectral distortions at the largest angular scales (greater than approximately 1°) within the ESA Voyage 2050 Program. We argue that an L-class mission with a pathfinder would allow a precise measurement of all the expected CSM distortions. With an M-class mission, the primordial distortions (created at z >~ 10(exp 3)) would still be detected at modest significance, while the late-time distortions will continue to be measured to high accuracy. Building on the heritage of COBE/FIRAS, a spectrometer that consists of multiple, cooled (approximately equal to 0.1 K), absolutely-calibrated Fourier Transform Spectrometers (FTS) with wide frequency coverage (ν approximately equal to 10 GHz to a few x THz) and all-sky spectral sensitivity at the level of 0.1 0.5 Jy/sr would be the starting point for the M-class option. A scaled and further optimized version of this concept is being envisioned as the L-class option. Such measurements can only be done from space and would deliver hundreds of absolutely-calibrated maps of the Universe at large scales, opening numerous science opportunities for cosmology and astrophysics. This will provide independent probes of inflation, dark matter and particle physics, recombination and the energy output of our Universe from at late times, turning the long-standing spectral distortion limits of COBE/FIRAS into clear detections.

Chluba, J.↗

Composite Infrared Spectrometer (CIRS) on Cassini

The Cassini spacecraft orbiting Saturn carries the composite infrared spectrometer (CIRS) designed to study thermal emission from Saturn and its rings and moons. CIRS, a Fourier transform spectrometer, is an indispensable part of the payload providing unique measurements and important synergies with the other instruments. It takes full advantage of Cassini's 13-year-long mission and surpasses the capabilities of previous spectrometers on Voyager 1 and 2. The instrument, consisting of two interferometers sharing a telescope and a scan mechanism, covers over a factor of 100 in wavelength in the mid and far infrared. It is used to study temperature, composition, structure, and dynamics of the atmospheres of Jupiter, Saturn, and Titan, the rings of Saturn, and surfaces of the icy moons. CIRS has returned a large volume of scientific results, the culmination of over 30 years of instrument development, operation, data calibration, and analysis. As Cassini and CIRS reach the end of their mission in 2017, we expect that archived spectra will be used by scientists for many years to come.

Jennings, Donald E.↗

The Composite Infrared Spectrometer

The Composite Infrared Spectrometer (CIRS) is a remote sensing instrument to be flown on the Cassini orbiter. It contains two Fourier transform spectrometers covering wavelengths of 7-1000 microns. The instrument is expected to have higher spectral resolution, smaller field of view, and better signal-to-noise performance than its counterpart, IRIS, on the Voyager missions. These improvements allow the study of the variability of the composition and temperature of the atmospheres of both Saturn and Titan with latitude, longitude and height, as well as allowing the possibility of discovery of previously undetected chemical species in these atmospheres. The long wavelengths accessible to CIRS allow sounding deeper into both atmospheres than was possible with IRIS.

Calcutt, Simon↗

Effects of Shear, Defocus, and Wavefront Error on the Theoretical Performance of the Composite Infrared Spectrometer for Cassini

The combined effects on performance of shear between the two arms, defocus of die detector, and difference in wavefront between the two arms of a Fourier transform spectrometer using cube corner retroreflectors were investigated. Performance was characterized by the amplitude of the fringe signals coming from a detector as the path-length difference was scanned. A closed-form expression was found for the combined effects of shear and defocus, and it was found that defocus had no effect in the absence of shear. The effect of wavefront error was modeled numerically and assumed to be independent of shear and defocus. Results were compared with measurements made on the breadboard and engineering model of the Composite Infrared Spectrometer for the Cassini mission to Saturn, and good agreement was found.

Martino, Antonio J.↗

The Atmospheres of Titan and Saturn in the Infrared from Cassini: The Interplay Between Observation and Laboratory Studies

The Composite Infrared Spectrometer (CIRS) aboard the Cassini spacecraft has been recording spectra of Saturn and Titan since its arrival in the Saturn system in 2004. CIRS, a Fourier transform spectrometer, observes the thermal infrared spectrum of both atmospheres from 10 to 1500/cm with resolutions up to 0.5/cm (Flasar et al. 2004). From these data CIRS provides global coverage of the molecular composition of the stratosphere and troposphere, as well as maps of temperature and winds. From such studies CIRS helps reveal the chemistry and evolutionary history of Saturn and Titan and their relationships to other Solar System bodies. The Cassini mission is continuing until 2017, permitting CIRS to search for atmospheric changes during more than a Saturnian season. By combining with results from Voyager (1980, 1981) the baseline becomes more than one Saturnian year (Coustenis et al. 2011). CIRS spectroscopy of the atmospheres of Saturn and Titan has raised a variety of questions that require new laboratory studies. A complete understanding of the CIRS high-resolution atmospheric spectra cannot be fully achieved without new or improved line positions and intensities for some trace molecules (e.g., Nixon et al. 2009). Isotopic variants of some of the more abundant species often need improved line parameters in order to derive isotopic ratios (e.g., Coustenis et al. 2008 and Fletcher et a!. 2009). Isotopic ratios contain information about the history of an atmosphere if experimental fractionation rates are available (Jennings et al. 2009). Some aerosol and haze features continue to defy identification and will not be explained without better knowledge of how these materials are formed and until we obtain their laboratory spectra. The interaction between CIRS investigations and laboratory research has been productive and has already led to new discoveries.

Jennings, D. E.↗

Characterization of Aerogel Scattering Filters for Astronomical Telescopes

We have developed a suite of novel infrared-blocking filters made by embedding scattering particles in a polymer aerogel substrate. Our developments allow us to tune the spectral performance of the filters based on both the composition of the base aerogel material and the properties of the scattering particles. Our filters are targeted for use in a variety of applications, from ground-based CMB experiments to planetary science probes. We summarize the formulations we have fabricated and tested to date, including several polyimide base aerogel formulations incorporating a range of size distributions of diamond scattering particles. We also describe the spectral characterization techniques used to measure the filters’ optical properties, including the development o fa mm-wave Fourier transform spectrometer testbed.

aerogel, filter, blocking, scattering, Fourier Tra↗

Spectrometer Baseline Control Via Spatial Filtering

An absorptive half-moon aperture mask is experimentally explored as a broad-bandwidth means of eliminating spurious spectral features arising from reprocessed radiation in an infrared Fourier transform spectrometer. In the presence of the spatial filter, an order of magnitude improvement in the fidelity of the spectrometer baseline is observed. The method is readily accommodated within the context of commonly employed instrument configurations and leads to a factor of two reduction in optical throughput. A detailed discussion of the underlying mechanism and limitations of the method are provided.

Burleigh, M. R.↗

In-Flight Performance of the TES Loop Heat Pipe Rejection System: Seven Years in Space

The Tropospheric Emission Spectrometer (TES) instrument heat rejection system has been operating in space for nearly 8 years since launched on NASA's EOS Aura Spacecraft. The instrument is an infrared imaging fourier transform spectrometer with spectral coverage of 3.2 to 15.4 microns. The loop heat pipe (LHP) based heat rejection system manages all of the instrument components waste heat including the two mechanical cryocoolers and their drive electronics. Five propylene LHPs collect and transport the instrument waste heat to the near room temperature nadir viewing radiators. During the early months of the mission, ice contamination of the cryogenic surfaces including the focal planes led to increased cryocooler loads and the need for periodic decontamination cycles. Focal plane decontamination cycles require power cycling both cryocoolers which also requires the two cryocooler LHPs to turn off and on during each cycle. To date, the cryocooler LHPs have undergone 24 start-ups in orbit successfully. This paper reports on the TES cryocooler loop heat pipe based heat rejection system performance. After a brief overview of the instrument thermal design, the paper presents detailed data on the highly successful space operation of the loop heat pipes since instrument turn-on in 2004. The data shows that the steady-state and transient operation of the LHPs has not changed since 2004 and shows consistent and predictable performance. The LHP based heat rejection system has provided a nearly constant heat rejection heat sink for all of its equipment which has led to exceptional overall instrument performance with world class science.

allowable flight temperature↗

The Tropospheric Emission Spectrometer: From Discovery Mission to Earth System Sounding

The Tropospheric Emission Spectrometer (TES) was launched aboard the Aura spacecraft in 2004 and decommissioned in February 2018. Over more than a decade of observations, TES has shown the potential of high-resolution Fourier Transform Spectrometer (FTS) measurements to alter our understanding of atmospheric composition and its relationship to the Earth System. We survey some of the major contributions TES has made to understanding air quality, chemistry-climate interactions, atmospheric hydrology, and carbon cycle science. We then show how innovations in retrieval methods pioneered by the TES team are now being applied to multi-spectral, multi-instrument records, establishing a new paradigm for composition measurements into the future.

Bowman, Kevin W.↗

Maintaining Flatness of a Large Aperture Potassium Bromide Beamsplitter Through Mounting and Vibration

The Composite Infrared Spectrometer (CIRS) instrument on the Cassini Mission launched in October of 1997. The CIRS instrument contains a mid-infrared (MIR) and a far-infrared interferometer (FIR) and operates at 170 Kelvin. The MIR is a Michelson Fourier transform spectrometer utilizing a 76 mm (3 inch) diameter potassium bromide beamsplitter and compensator pair. The potassium bromide elements were tested to verify effects of cooldown and vibration prior to integration into the instrument. The instrument was then aligned at ambient temperatures, tested cryogenically and re-verified after vibration. 'Me stringent design optical figure requirements for the beamsplitter and compensator included fabrication errors, mounting stresses and vibration load effects. This paper describes the challenges encountered in mounting the elements to minimize distortion and to survive vibration.

Losch, Patricia↗

Maintaining Flatness of a Large Aperture Potassium Bromide Beamsplitter through Mounting and Vibration

The Composite Infrared Spectrometer (CIRS) instrument on the Cassini Mission launched in October of 1997. The CIRS instrument contains a mid-infrared and a far-infrared interferometer and operates at 170 Kelvin. The mid-infrared interferometer is a Michelson- type Fourier transform spectrometer utilizing a 3 inch diameter potassium bromide beamsplitter/compensator pair. The potassium bromide elements were tested to verify effects of cooldown and vibration prior to integration into the instrument. The instrument was then aligned at ambient temperatures, tested cryogenically and re-verified after vibration. The stringent design optical figure requirements for the beamsplitter and compensator included fabrication errors, mounting stresses and vibration load effects. This paper describes the challenges encountered in mounting the elements to minimize distortion and to survive vibration.

Losch, Patricia↗

Measurement of HO2 And Other Trace Gases in The Stratosphere Using a High Resolution Far-Infrared Spectrometer

This report covers the time period 1 April 1999 to 31 March 2000. During this period we continued analyzing data from past flights, exploring issues such as radical partitioning, stratospheric transport, and stratosphere-troposphere exchange. With funding from Smithsonian we have also completed a preliminarY design for a compact, lightweight, next-generation Fourier-transform spectrometer.

Traub, Wesley A.↗

Development of a Submillimeter-Wavelength Immersion Grating Spectrometer

The broad goal of this project was to develop a broadband, moderate-resolution spectrometer for submillimeter wavelengths. Our original approach was to build an immersion grating spectrometer, and as such, the first step was to identify the best material (lowest loss, highest index) for the grating medium, and to characterize its properties at the foreseen optical-bench operating temperature of 1.5 K. To this end, we put our initial efforts into upgrading an existing laboratory submillimeter Fourier transform spectrometer, which allowed us to carry out the requisite materials measurements. The associated cryogenic detector dewar was also redesigned and rebuilt to carry out this work. This dewar houses the 1.5 K detector and the filter wheel used in the materials characterization. Our goal was to have the beam propagate through the samples as uniformly as possible, so the optics were redesigned to allow for the samples to be traversed by a well-defined collimated beam. The optics redesign also placed the samples at an image of the aperture stop located within the FTS. After the rebuild, we moved into the testing phase.

Phillips, T. G.↗