Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fractionalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Single Fraction Versus Fractionated Linac-Based Stereotactic Radiotherapy for Vestibular Schwannoma: A Single-Institution Experience

Purpose: To evaluate and compare outcomes for patients with vestibular schwannoma (VS) treated in a single institution with linac-based stereotactic radiosurgery (SRS) or by fractionated stereotactic radiotherapy (SRT). Methods and Materials: One hundred and nineteen patients (SRS = 78, SRT = 41) were treated. For both SRS and SRT, beam shaping is performed by a mini-multileaf collimator. For SRS, a median single dose of 12.5 Gy (range, 11-14 Gy), prescribed to the 80% isodose line encompassing the target, was applied. Of the 42 SRT treatments, 32 treatments consisted of 10 fractions of 3-4 Gy, and 10 patients received 25 sessions of 2 Gy, prescribed to the 100% with the 95% isodose line encompassing the planning target volume. Mean largest tumor diameter was 16.6 mm in the SRS and 24.6 mm in the SRT group. Local tumor control, cranial nerve toxicity, and preservation of useful hearing were recorded. Any new treatment-induced cranial nerve neuropathy was scored as a complication. Results: Median follow-up was 62 months (range, 6-136 months), 5 patients progressed, resulting in an overall 5-year local tumor control of 95%. The overall 5-year facial nerve preservation probability was 88% and facial nerve neuropathy was statistically significantly higher after SRS, after prior surgery, for larger tumors, and in Koos Grade {>=}3. The overall 5-year trigeminal nerve preservation probability was 96%, not significantly influenced by any of the risk factors. The overall 4-year probability of preservation of useful hearing (Gardner-Robertson score 1 or 2) was 68%, not significantly different between SRS or SRT (59% vs. 82%, p = 0.089, log rank). Conclusion: Linac-based RT results in good local control and acceptable clinical outcome in small to medium-sized vestibular schwannomas (VSs). Radiosurgery for large VSs (Koos Grade {>=}3) remains a challenge because of increased facial nerve neuropathy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Radiation Therapy (66 Gy in 22 Fractions at 3 Gy per Fraction) for Favorable-Risk Prostate Cancer: Long-term Outcomes

Purpose: To report long-term outcomes of low- and intermediate-risk prostate cancer patients treated with high-dose hypofractionated radiation therapy (HypoRT). Methods and Materials: Patients with low- and intermediate-risk prostate cancer were treated using 3-dimensional conformal radiation therapy to a dose of 66 Gy in 22 daily fractions of 3 Gy without hormonal therapy. A uniform 7-mm margin was created around the prostate for the planning target volume, and treatment was prescribed to the isocenter. Treatment was delivered using daily ultrasound image-guided radiation therapy. Common Terminology Criteria for Adverse Events, version 3.0, was used to prospectively score toxicity. Biochemical failure was defined as the nadir prostate-specific antigen level plus 2 ng/mL. Results: A total of 129 patients were treated between November 2002 and December 2005. With a median follow-up of 90 months, the 5- and 8-year actuarial biochemical control rates were 97% and 92%, respectively. The 5- and 8-year actuarial overall survival rates were 92% and 88%, respectively. Only 1 patient died from prostate cancer at 92 months after treatment, giving an 8-year actuarial cancer-specific survival of 98%. Radiation therapy was well tolerated, with 57% of patients not experiencing any acute gastrointestinal (GI) or genitourinary (GU) toxicity. For late toxicity, the worst grade ≥2 rate for GI and GU toxicity was 27% and 33%, respectively. There was no grade >3 toxicity. At last follow-up, the rate of grade ≥2 for both GI and GU toxicity was only 1.5%. Conclusions: Hypofractionation with 66 Gy in 22 fractions prescribed to the isocenter using 3-dimensional conformal radiation therapy produces excellent biochemical control rates, with moderate toxicity. However, this regimen cannot be extrapolated to the intensity modulated radiation therapy technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Do Coordinated Knowledge Translation Campaigns Persuade Radiation Oncologists to Use Single-Fraction Radiation Therapy Compared With Multiple-Fraction Radiation Therapy for Bone Metastases?

Although level 1 evidence supports the use of single-fraction radiation therapy (SFRT) compared with multiple-fraction radiation therapy (MFRT) for the palliative management of bone metastases, SFRT is underused. In early 2017, the Canadian Partnership Against Cancer and CancerCare Manitoba undertook a comprehensive knowledge translation campaign in Manitoba, Canada featuring educational outreach visits, local consensus meetings, and audit and feedback interventions to encourage greater use of SFRT. This study assessed the impact of this campaign on SFRT use and identified variables associated with MFRT usage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ternary Phase Diagram of Water/Bio-Oil/Organic Solvent for Bio-Oil Fractionation

Separating bio-oil by fractionation with different chemical composition is a critical step to refine these oils and obtain high value products. Cold-water precipitation of pyrolytic lignin from bio-oil is the most common approach used. However, the obtained aqueous phase from this method still contain phenols, is diluted and difficult to use. In this study, the use of liquid-liquid extraction with different solvents (1-butanol, ethyl acetate, 1-octanol, dichloromethane, toluene, and hexane) for the separation of targeted molecules (lignin oligomers, sugars, acetic acid) is explored. Ternary phase diagrams for the organic solvent/water/bio-oil are reported. The partition coefficient of compounds of interest (both light and heavy fraction) is reported for the liquid-liquid equilibrium zone. When using butanol as solvent, the highest separation factor of total phenols over total sugars was observed. Furthermore, our results provide information to design L-L separation units with the capacity to selectively recover targeted molecules from pyrolysis oils.

09 BIOMASS FUELS↗

Improving Land Surface Temperature Simulation in CoLM Over the Tibetan Plateau through Fractional Vegetation Cover Derived from a Remotely Sensed Clumping Index and Model-Simulated Leaf Area Index

Parameterizations of fractional vegetation cover (FVC) in land surface models have important effects on simulations of surface energy budget, especially in arid and semiarid regions. This study uses a FVC scheme in which FVC is derived from leaf area index and a remotely sensed clumping index. The performance of the new scheme (SMFVC) is evaluated against Moderate Resolution Imaging Spectroradiometer (MODIS) land surface temperature (LST) and in situ soil temperature observations, together with two other FVC schemes, a general FVC scheme (CTL) based on land cover map and a climatology-based FVC scheme (RSFVC) that uses long-term remotely sensed Normalized Difference Vegetation Index of MODIS. The three FVC schemes were implemented in the Common Land Model (CoLM) and applied in the Tibetan Plateau using the same forcing data and default parameters. Our results demonstrate that FVC schemes have significant influence on the CoLM performance: (1) the RSFVC and SMFVC schemes significantly reduce the LST biases found in CTL, particularly in grassland and during summer; (2) soil temperature evaluation by in situ observations from three networks on the Tibetan Plateau corroborates the LST results; and (3) the improvements are mainly related to representing temporal (seasonal) variability and subgrid heterogeneity of FVC, which improves surface albedo and surface energy balance. In other words, by including more vegetation characteristics, such as using a clumping index, land surface models may better simulate surface vegetation condition and further better represent the land surface energy budget over the Tibetan Plateau.

Li, Chengwei↗

Elastic properties, sp³ fraction, and Raman scattering in low and high pressure synthesized diamond-like boron rich carbides

Dense BC{sub x} phases with high boron concentration are predicted to be metastable, superhard, and conductors or superconductors depending on boron concentration. However, up to this point, diamond-like boron rich carbides BC{sub x} (dl-BC{sub x}) phases have been thought obtainable only through high pressure and high temperature treatment, necessitating small specimen volume. Here, we use electron energy loss spectroscopy combined with transmission electron microscopy, Raman spectroscopy, surface Brillouin scattering, laser ultrasonics (LU) technique, and analysis of elastic properties to demonstrate that low pressure synthesis (chemical vapor deposition) of BC{sub x} phases may also lead to the creation of diamond-like boron rich carbides. The elastic properties of the dl-BC{sub x} phases depend on the carbon sp²versus sp³ content, which decreases with increasing boron concentration, while the boron bonds determine the shape of the Raman spectra of the dl-BC{sub x} after high pressure-high temperature treatment. Using the estimation of the density value based on the sp³ fraction, the shear modulus μ of dl-BC₄, containing 10% carbon atoms with sp³ bonds, and dl-B₃C₂, containing 38% carbon atoms with sp³ bonds, were found to be μ = 19.3 GPa and μ = 170 GPa, respectively. The presented experimental data also imply that boron atoms lead to a creation of sp³ bonds during the deposition processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of miniaturized, spectroscopically assisted Penning gauges for fractional helium and hydrogen neutral pressure measurements

Direct measurements of the helium (He) fractional neutral pressure in the neutral gas around fusion devices is challenging because of the small mass difference between the abundant D{sub 2} molecules and the He ash which will be produced by deuterium-tritium fusion. To study He exhaust, an in situ Penning gauge system is being developed at UW-Madison that is optimized for good pressure and high spectroscopic sensitivity. Three different anode geometries have been studied regarding their vacuum electrostatic fields, light output, and ion current. The light output of the two new anode configurations are at least one order of magnitude above the currently available designs, hence improving the spectroscopic sensitivity at similar total neutral pressure resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the Branching Fraction and Lambda-bar Polarization in B0 -> Lambda-par p pi-

We present a measurement of the B{sup 0} {yields} {bar {Lambda}}p{pi}{sup -} branching fraction performed using the BABAR detector at the PEP-II asymmetric e{sup +}e{sup -} collider. Based on a sample of 467 x 10{sup 6} B{bar B} pairs we measure {Beta}(B{sup 0} {yields} {bar {Lambda}}p{pi}{sup -}) [3.07 {+-} 0.31(stat.) {+-} 0.23(syst.)] x 10{sup -6}. The measured differential spectrum as a function of the dibaryon invariant mass m({bar {Lambda}}p) shows a near-threshold enhancement similar to that observed in other baryonic B decays. We study the {bar {Lambda}} polarization as a function of {bar {Lambda}} energy in the B{sup 0} rest frame (E*{sub {bar {Lambda}}}) and compare it with theoretical expectations of fully longitudinally right-polarized {bar {Lambda}} at large E*{sub {bar {Lambda}}}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of Branching Fractions and CP Asymmetries and Studies of Angular Distributions for B to phi phi K Decays

We present branching fraction and CP asymmetry measurements as well as angular studies of B {yields} {phi}{phi}K decays using 464 x 10{sup 6} B{bar B} events collected by the BABAR experiment. The branching fractions are measured in the {phi}{phi} invariant mass range below the {eta}{sub c} resonance (m{sub {phi}{phi}} < 2.85 GeV). We find {Beta}(B{sup +} {yields} {phi}{phi}K{sup +}) = (5.6 {+-} 0.5 {+-} 0.3) x 10{sup -6} and {Beta}(B{sup 0} {yields} {phi}{phi}K{sup 0}) = (4.5 {+-} 0.8 {+-} 0.3) x 10{sup -6}, where the first uncertaintiy is statistical and the second systematic. The measured direct CP asymmetries for the B{sup {+-}} decays are A{sub CP} = -0.10 {+-} 0.08 {+-} 0.02 below the {eta}{sub c} threshold (m{sub {phi}{phi}} < 2.85 GeV) and A{sub CP} = 0.09 {+-} 0.10 {+-} 0.02 in the {eta}{sub c} resonance region (m{sub {phi}{phi}} in [2.94,3.02] GeV). Angular distributions are consistent with J{sub P} = 0{sup -} in the {eta}{sub c} resonance region and favor J{sup P} = 0{sup +} below the {eta}{sub c} resonance.

79 ASTRONOMY AND ASTROPHYSICS↗

Invariant-mass and fractional-energy dependence of inclusive production of dihadrons in e + e - annihilation at s = 10.58 GeV

The inclusive cross sections for dihadrons of charged pions and kaons ( e + e - → h h X ) in electron-positron annihilation are observed and reported on. They are obtained as a function of the total fractional energy and invariant mass for any di-hadron combination in the same hemisphere as defined by the thrust event-shape variable and its axis. Since same-hemisphere dihadrons can be assumed to originate predominantly from the same initial parton, di-hadron fragmentation functions are probed. Moreove, these di-hadron fragmentation functions are needed as an unpolarized baseline in order to quantitatively understand related spin-dependent measurements in other processes and to apply them to the extraction of quark transversity distribution functions in the nucleon. The di-hadron cross sections are obtained from a 655 fb - 1 data sample collected at or near the Υ ( 4 S ) resonance with the Belle detector at the KEKB asymmetric-energy e + e - collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Branching Fractions of Bbar -> D** l^- nubar_l Decays in Events Tagged by a Fully Reconstructed B Meson

We report a measurement of the branching fractions of {bar B} {yields} D** {ell}{sup -}{bar {nu}}{sub {ell}} decays based on 417 fb{sup -1} of data collected at the {Upsilon}(4S) resonance with the BABAR detector at the PEP-II e{sup +}e{sup -} storage rings. Events are selected by fully reconstructing one of the B mesons in a hadronic decay mode. A fit to the invariant mass differences m(D{sup (*)})-m(D{sup (*)}) is performed to extract the signal yields of the different D** states. We observe the {bar B} {yields} D**{ell}{sup -}{bar {nu}}{sub {ell}} decay modes corresponding to the four D** states predicted by Heavy Quark Symmetry with a significance greater than six standard deviations including systematic uncertainties.

43 PARTICLE ACCELERATORS↗

Measurement of B->K*(892)gamma Branching Fractions and CP and Isospin Asymmetries

We present an analysis of the decays B{sup 0}->K*{sup 0}(892)gamma and B{sup +}->K*{sup +}(892)gamma using a sample of about 383x10{sup 6} BB events collected with the BABAR detector at the PEP-II asymmetric energy B factory. We measure the branching fractions B(B{sup 0}->K*{sup 0}gamma)=(4.47+-0.10+-0.16)x10{sup -5} and B(B{sup +}->K*{sup +}gamma)=(4.22+-0.14+-0.16)x10{sup -5}. We constrain the direct CP asymmetry to be -0.033<A(B->K*gamma)<0.028 and the isospin asymmetry to be 0.017<DELTA{sub 0-}<0.116, where the limits are determined by the 90% confidence interval and include both the statistical and systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for C P Violation and Measurement of the Branching Fraction in the Decay D 0 → K S 0 K S 0

In this work we study the decay D 0 → K S 0 K S 0 using 921 fb - 1 of data collected at or near the Υ ( 4 S ) and Υ ( 5 S ) resonances with the Belle detector at the KEKB asymmetric energy e + e - collider. The measured time-integrated C P asymmetry is A C P ( D 0 → K S 0 K S 0 ) = ( - 0.02 ± 1.53 ± 0.02 ± 0.17 ) % , and the branching fraction is B ( D 0 → K S 0 K S 0 ) = ( 1.321 ± 0.023 ± 0.036 ± 0.044 ) × 10 - 4 , where the first uncertainty is statistical, the second is systematic, and the third is due to the normalization mode ( D 0 → K S 0 π 0 ). These results are furthermore more precise than previous measurements available for this mode. The A C P measurement is consistent with the standard model expectation.