Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAS CELL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

In-situ measurement of moist flue gas under high pressure using a nafion dryer and FTIR

The formation of the main flue gas species (NOx, SOx, CO2, and CO) in pressurized oxy-fuel combustion can be fundamentally different from oxy-fuel combustion at atmospheric pressure. To accurately obtain the concentration of these gas species in a pressurized oxy-fuel combustor, a gas measurement which maintains the sampling pressure is needed. Very few published studies have accomplished this, and never under the conditions reported herein. In this work, we fire PRB coal in a 100 kWth staged pressurized oxy-fuel combustor (SPOC) under a pressure 15 bara. We utilize a state-of-the-art FTIR (Thermo Scientific Nicolet iS20) with a novel high-pressure gas cell that is under process pressure to measure the in-situ flue-gas concentration in a sampled flow. However, water vapor can significantly interfere with the FTIR measurement, particularly under pressure. To address this problem, we have developed a high-pressure nafion dryer to selectively remove the water vapor from the flue gas while retaining the flue gas species. This approach can significantly increase the signal-noise ratio for the FTIR. By integrating the nafion dryer and the high-pressure gas cell, we were able to successfully measure flue gas species at system pressure with the FTIR.

Cheng, Mao↗

Techno-Economic Analysis of Natural Gas Fuel Cell Plant Configurations

The United States (U.S.) Department of Energy (DOE) Office of Fossil Energy and Carbon Management (FECM) and the National Energy Technology Laboratory (NETL) have been pursuing the development of solid oxide fuel cell (SOFC) technology to enable future power generation systems that are consistent with the cornerstones of the DOE mission—to ensure America’s security and prosperity by addressing its energy and environmental challenges through transformative science and technology solutions. The U.S. DOE FECM SOFC Program is currently focused on the development of low-cost, highly efficient, and reliable SOFC power systems. NETL’s SOFC technology development roadmap is aligned with near-term market opportunities in the distributed generation sector to validate and advance the technology while paving the way for utility-scale (> 50 MW) natural gas and coal-derived synthesis gas-fueled applications via progressively larger system demonstrations. The present study represents a part of a series of system evaluations being developed at NETL to aid in prioritizing technological advances along research pathways to the realization of utility-scale SOFC systems, a transformational goal of the fuel cell program. In particular, the system performance of utility-scale natural gas fuel cell (NGFC) systems with and without carbon dioxide (CO 2 ) capture is presented. The objective of the study is to provide targeted research and development (R&D) guidance to the FECM SOFC Program and SOFC commercial developers to accelerate technology deployment.

03 NATURAL GAS↗

Spatially coherent high-order harmonics generated at optimal high gas pressure with high-intensity one- or two-color laser pulses

Here, we investigate the gas-pressure dependence of macroscopic harmonic spectra generated in a high-ionization medium using intense 800-nm laser pulses. The harmonics obtained at the optimal pressure show good spatial coherence with small divergence (less than 2 mrad) in the far field. By analyzing the evolution of the laser's electric field as it propagates, we find that dynamic phase matching conditions are fulfilled in the second half of the gas cell and that harmonic yields do not depend on the position of the gas cell with respect to the focusing position. We also demonstrate that harmonic yields at the optimal pressure can be further enhanced by increasing input laser energy or by adding a few percent of second or third harmonic to the fundamental.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical study of charge exchange collisions between He+ and CO2.

Helium ions were produced in an electron bombardment ion source and directed into a gas cell containing carbon dioxide. A Wien filter placed between the ion source and the gas cell insured that only singly charged helium ions reached the cell. The spectrum obtained for the bombardment of carbon dioxide with the helium ions at 1200 eV is shown in a graph. Prominent features of the lower spectrum are two atomic lines at 3889 and 4471 A.

Coplan, M. A.↗

Effect of collisions on the shape of the coherent population trapping resonance detected by the Ramsey method

We report on a theoretical model of the effect of coherent population trapping in alkali atoms in an optically thin gas cell with a buffer gas at a nonzero temperature in a pulsed laser field. The shape of the Ramsey resonance is analysed for two different temperature ranges, i. e. for a ‘cold’ atomic ensemble and for an ensemble of ‘hot’ atoms in a cell with a buffer gas. The influence of the hyperfine structure of the excited level on the shift of the central Ramsey resonance is investigated. (paper)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray absorption spectroscopy measurements of radiatively ionized argon gas

X-ray absorption spectroscopy is a diagnostic tool that can characterize the temperature and ionization state of a plasma. This technique requires experiments to characterize the platform, careful data calibration, and comparison with atomic models to understand the plasma parameters. We performed ionizing radiation wave experiments at the OMEGA Laser Facility that used an ∼ 80 eV X-ray source to heat an Argon (Ar) gas cell at fill pressures of 3 atm. To diagnose the Ar plasma, we used a capsule backlighter offset 10 mm from the gas cell, to produce X-rays that were absorbed by the ionized Ar gas. The absorption analysis was calibrated using the significant line structure in the backlighter spectrum, which served as independent energy fiducials enabling definitive measurements of a 50-eV shift in the energy of the Ar K-edge due to ionization. We compare the measured absorption spectra to two independent atomic models, PrismSPECT and SCRAM, and show that the observed K-edge shift in the heated gas is consistent with ionization up to Ar 4+ and temperatures of 10 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Role of Gas in Determining Image Quality and Resolution During In Situ Scanning Transmission Electron Microscopy Experiments

As gas-solid heterogeneous catalytic reactions are molecular in nature, a full mechanistic understanding of the process requires atomic scale characterization under realistic operating conditions. While atomic resolution imaging has become a routine in modern high-vacuum (scanning) transmission electron microscopy ((S)TEM), both image quality and resolution nominally degrade when reaction gases are introduced. In this work, we systematically assess the effects of different gases at various pressures on the quality and resolution of images obtained at room temperature in the annular dark field STEM imaging mode using a differentially pumped (DP) gas cell. This imaging mode is largely free from inelastic scattering effects induced by the presence of gases and retains good imaging properties over a wide range of gas mass/pressures. We demonstrate the application of the ESTEM with atomic resolution images of a complex oxide alkane oxidation catalyst MoVNbTeOx (M1) immersed in light and heavy gas environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic field effects on laser energy deposition and filamentation in magneto-inertial fusion relevant plasmas

We report on experimental measurements of how an externally imposed magnetic field affects plasma heating by kJ-class, nanosecond laser pulses. The experiments reported here took place in gas cells analogous to magnetized liner inertial fusion targets. We observed significant changes in laser propagation and energy deposition scale lengths when a 12T external magnetic field was imposed in the gas cell. We find evidence that the axial magnetic field reduces radial electron thermal transport, narrows the width of the heated plasma, and increases the axial plasma length. Reduced thermal conductivity increases radial thermal gradients. This enhances radial hydrodynamic expansion and subsequent thermal self-focusing. Our experiments and supporting 3D simulations in helium demonstrate that magnetization leads to higher thermal gradients, higher peak temperatures, more rapid blast wave development, and beam focusing with an applied field of 12T.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atomic kinetics of laboratory photoionized plasmas relevant to astrophysics. Final report

The major goal of this project was to study the atomic and radiation physics of photoionized plasmas driven by a broadband x-ray flux and its impact on plasma x-ray heating and ionization, emissivity and opacity, and radiation-hydrodynamics. This problem is relevant to the physics of accretion disks surrounding black holes, x-ray binaries, and active galactic nuclei in astrophysics. In addition, it is also important for understanding non-equilibrium laboratory plasmas driven by a distribution of photons. To this end, and motivated by previous and ongoing gas-cell experiments performed by the PI at the Z facility of Sandia National Laboratories, we developed a new experimental platform at the 1MA Zebra pulsed power accelerator of the University of Nevada, Reno based on using a gas jet produced by a supersonic nozzle. The gas jet is turned into a photoionized plasma driven by the x- ray flux from a wire-array z-pinch. Establishing this new experimental platform at Zebra was a major goal of this project. In addition, we have also dedicated effort to continue complementary experiments at the Z facility using the gas-cell photoionized plasma set up with support from the Fundamental Science Program at Z as well as to perform data processing and analysis, and theory and modeling simulations, including electron kinetics and radiation-hydrodynamics. Since we seek to test and establish what physics models are needed to describe photoionized plasma guided by experimental observation, these complementary experimental efforts were central to achieving the goals of this project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metal-Supported Solid Oxide Fuel Cells for Natural Gas

Solid oxide fuel cells (SOFCs) are high temperature energy conversion devices that produce electricity efficiently and sustainably. High operating temperatures required for SOFC function endow these devices with many advantages including fuel flexibility and high conversion efficiencies. Fuel flexibility, in particular, distinguishes SOFCs from other types of fuel cells that operate with clean H 2 only, and enables operation with natural gas (NG). LBNL has developed metal supported SOFCs (MS-SOFCs) with unique symmetrical architecture that offer several advantages over state of the art (SoA) ceramic SOFC models including inexpensive materials, rapid start up capability, increased mechanical strength and high tolerance to thermal cycling, Fig 1. These advantages make LBNL MS-SOFCs uniquely suited for fast start-up, portable, and mobile backup generator applications. Specifically motivating this work was a scenario of backup generators fueled by pipeline natural gas delivered from SoCalGas in the event of an electric grid shut down. This project investigates the feasibility of using MS-SOFCs with pre-reformed natural gas as well as direct on-cell reforming of simulated natural gas both with and without sulfur.

03 NATURAL GAS↗

Mid Infra-Red Laser Sensor for Continuous Sulfur Trioxide Monitoring to Improve Coal-Fired Power Plant Performance during Flexible Operations

During the course of this project, we performed exhaustive research and development of SO3/H2SO4 sensing technology for coal-fired power plant applications (Figure 1). The development culminated in a successful field campaign of a prototype continuous real-time H2SO4 monitor at a coal-fired power plant (TRL 6) accomplishing the primary goal of the project. The developed sensors utilize tunable laser absorption spectroscopy (TLAS) operating in the mid-infrared (Mid-IR) wavelength region, which is the so-called “molecular fingerprint” region. Systems operating in the Mid-IR have orders of magnitude more sensitivity than systems operating at shorter wavelengths, such as near-infrared (NIR). However, NIR systems are more widespread due to more mature supporting technology (e.g., fiber optics, optical components, etc.). In this project, we not only produced a specific Mid-IR sensor, we also advanced Mid-IR sensor technology in general through the development and demonstration of such supporting technology. In this project, we also developed proprietary broad tuning lasers enabling the ability to effectively measure SO3, H2SO4, H2O, and SO2. Different molecular species have unique spectral signatures that can be probed with lasers operating at different wavelengths. Standard TLAS uses relatively narrow wavelength tuning distributed feedback (DFB) lasers, which can typically only target a single species with narrow features, and are not appropriate for species with broad features, such as SO3 or H2SO4. In contrast, by developing unique, broad-tuning laser technology, we were able to measure these species, as well as SO2 and H2O simultaneously. Furthermore, to enable real-time analysis at a power plant, we modified a commercially available heated gas cell to operate in the Mid-IR wavelength range and fiber coupled the lasers to enable remote delivery of the beams. To generate reference data (library spectra), our collaborators at the University of California Irvine (UCI) developed a catalytic SO3 generation facility. It is worth mentioning that representative H2SO4 and SO3 Mid-IR spectra are not a part of any publicly available database and the data generated under this project is a valuable resource in and of itself. In addition, based on the UCI study we determined that detection of SO3 is complicated by the very strong SO2 absorption. For that reason, we concentrated on H2SO4 detection. Since SO3 and H2SO4 exist in a flue gas in a state of equilibrium, which depends on temperature and humidity, by measuring water concentration and controlling the temperature of the gas cell, we developed an approach to determine SO3 concentration from the H2SO4 measurement. During the development phase of the project, we performed three testing campaigns at our collaborator’s FERCo flue gas facility with conditions representative of the coal-fired power plant (~ 40ppm SO3, 1700ppm to 2800 ppm SO2, 10% water) with the exception of particulate matter. After three test campaigns at FERCo we performed field testing at Harrison Power Station. The final system was mounted on a duct and measured H2SO4, SO2 and water. The tests were highly successful with a demonstrated real-time H2SO4 precision of 1 ppm with a 1 second update. Our collaborators at EPRI conducted an industry survey and determined that there is a very high interest for the SO3/H2SO4 monitoring in the power generation industry as well as in heavy industries in general. Furthermore, work performed by OptoKnowledge beyond the scope of this project under a synergistic DOE SBIR determined another approach to SO3 detection. We applied for Phase II on this SBIR for development a of versatile SO3/H2SO4 sensor but were not selected. We are currently looking for another opportunity to leverage all the technological advancements produced by this project including but not limited to the flue gas facility at UCI, the hardware and software developed, and relationships with FERCo, EPRI CEMTEK, and Harrison Station.

01 COAL, LIGNITE, AND PEAT↗

Analysis of the Two-Level NO PLIF Model for Low-Temperature High-Speed Flow Applications

The current work compares experimentally obtained nitric oxide (NO) laser-induced fluorescence (LIF) spectra with the equivalent spectra obtained analytically. The experimental spectra are computed from captured images of fluorescence in a gas cell and from a laser sheet passing through the fuel-air mixing flowfield produced by a high-speed fuel injector. The fuel injector is a slender strut that is currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. This injector is placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number airflow at the entrance of a scramjet combustor, and injects helium, which is used as an inert substitute for hydrogen fuel. Experimental planar (P) LIF is obtained by using a UV laser to excite fluorescence from the NO molecules that are present in either a gas cell or the facility air used for the EIMP experiments. The experimental data are obtained for several segments of the NO fluorescence spectrum. The selected segments encompass LIF lines with rotational quantum numbers appropriate for low-to-moderate temperature flows similar to those corresponding to the nominal experimental flow conditions. The experimental LIF spectra are then evaluated from the data and compared with those obtained from the theoretical models. The theoretical spectra are obtained from LIFBASE and LINUS software, and from a simplified version of the two-level fluorescence model. The equivalent analytic PLIF images are also obtained by applying only the simplified model to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield. Good agreement between the experimental and theoretical results provides increased confidence in both the simplified LIF modeling and CFD simulations for further investigations of high-speed injector performance using this approach.

Drozda, Tomasz G.↗

Analysis of the Two-Level NO PLIF Model for Low-Temperature High-Speed Flow Applications

The current work compares experimentally obtained nitric oxide (NO) laser-induced fluorescence (LIF) spectra with the equivalent spectra obtained analytically. The experimental spectra are computed from captured images of fluorescence in a gas cell and from a laser sheet passing through the fuel-air mixing flowfield produced by a high-speed fuel injector. The fuel injector is a slender strut that is currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. This injector is placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number airflow at the entrance of a scramjet combustor, and injects helium, which is used as an inert substitute for hydrogen fuel. Experimental planar (P) LIF is obtained by using a UV laser to excite fluorescence from the NO molecules that are present in either a gas cell or the facility air used for the EIMP experiments. The experimental data are obtained for several segments of the NO fluorescence spectrum. The selected segments encompass LIF lines with rotational quantum numbers appropriate for low-to-moderate temperature flows similar to those corresponding to the nominal experimental flow conditions. The experimental LIF spectra are then evaluated from the data and compared with those obtained from the theoretical models. The theoretical spectra are obtained from LIFBASE and LINUS software, and from a simplified version of the two-level fluorescence model. The equivalent analytic PLIF images are also obtained by applying only the simplified model to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield. Good agreement between the experimental and theoretical results provides increased confidence in both the simplified LIF modeling and CFD simulations for further investigations of high-speed injector performance using this approach.

Tomasz G Drozda↗

Pulse dilation gas Cherenkov detector for ultra-fast gamma reaction history at the National Ignition Facility (invited)

The Cherenkov mechanism used in Gas Cherenkov Detectors (GCDs) is exceptionally fast. However, the temporal resolution of GCDs, such as the Gamma Reaction History diagnostic at the National Ignition Facility (NIF), has been limited by the current state-of-the-art photomultiplier tube technology to ~100 ps. The soon-to-be deployed Pulse Dilation Photomultiplier Tube (PD-PMT) at NIF will allow for temporal resolution comparable to that of the gas cell or ~10 ps. Enhanced resolution will contribute to the quest for ignition in a crucial way through precision measurements of reaction history and ablator areal density (ρR) history, leading to better constrained models. Features such as onset of alpha heating, shock reverberations, and burn truncation due to dynamically evolving failure modes may become visible for the first time. Test measurements of the PD-PMT at Atomic Weapons Establishment confirmed that design goals have been met. The PD-PMT provides dilation factors of 2 to 40× in 6 increments. The GCD-3 recently deployed at the NIF has been modified for coupling to a PD-PMT and will soon be making ultrafast measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative isotopic measurements of gas-phase alcohol mixtures using a broadly tunable swept external cavity quantum cascade laser

A swept-ECQCL is used for broadband IR spectroscopy of isotopic mixtures of CH3OH, CH3OD, CH3CH2OH, and CH3CH2OD in a static gas cell over a wavelength range of 9.5 to 10.4 µm. A weighted least squares fitting approach with quantitative library spectra illustrates that significant spectral congestion does not negatively impact the ability for in situ quantification of large isotopic species in a mixture. The noise equivalent concentrations for CH3OH, CH3OD, CH3CH2OH, and CH3CH2OD are 19 ppbv x m, 28 ppbv x m, 450 ppbv x m, and 330 ppbv x m respectively for a 50 second integration time. Based on the observed NECs, isotopic precisions of 0.07‰ and 0.79‰ for a 50 s integration time are calculated for measurements of the [MeOD]/[MeOH] and [EtOD]/[EtOH] isotope ratios , respectively, for the species concentrations in the gas cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating CO 2 -to-formic acid electrocatalysts in different device configurations

We evaluated CO 2 electroreduction differences of three materials in aqueous H-cell, gas diffusion electrode (GDE) half-cell, and full-cell electrolyzer devices. Mass-transport limited catalyst differences in H-cells become more apparent in gas-fed GDE half-cells; however, voltage contributions from device components can mask cathode differences in full-cell devices until high current density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of spatially and temporally resolved electron density measurements for the assessment of radiation hydrodynamics simulations of laboratory X-ray photoionized plasmas

The photoionized plasma gas cell experiment is an established platform we use to make at-parameter (ξ > > 1 ergs cm s –1 ) measurements of plasma properties with application to high-energy astrophysical systems. We model the experiments with 1D radiation hydrodynamics simulations using the HELIOS-CR code to inform our understanding and assist in the interpretation of results. The simulations predict that the bulk of the plasma is in a quasi-uniform and hydrodynamically unperturbed state throughout the duration of the experiment. To evaluate this prediction, we introduced a photonic Doppler velocimetry (PDV) diagnostic to measure spatially and temporally resolved plasma electron density. The initial measurements were successful but had limitations that made model-data comparisons challenging. To address this, we re-designed the gas cell PDV diagnostic and doubled the number of measurement locations to sample across two thirds of the depth of the cell. We also present a comparison of the results from the upgraded PDV diagnostic to the HELIOS-CR simulations for the first time. As a result, the experimental data confirms the prediction of an unperturbed region in the bulk of the plasma but reveals discrepancies in the time evolution and spatial distribution of the simulated electron density.

79 ASTRONOMY AND ASTROPHYSICS↗

Compact CH 4 sensor system based on a continuous-wave, low power consumption, room temperature interband cascade laser

A tunable diode laser absorption spectroscopy-based methane sensor, employing a dense-pattern multi-pass gas cell and a 3.3 µm, CW, DFB, room temperature interband cascade laser (ICL), is reported. The optical integration based on an advanced folded optical path design and an efficient ICL control system with appropriate electrical power management resulted in a CH 4 sensor with a small footprint (32 x 20 x 17 cm 3 ) and low-power consumption (6 W). Polynomial and least-squares fit algorithms are employed to remove the baseline of the spectral scan and retrieve CH 4 concentrations, respectively. An Allan-Werle deviation analysis shows that the measurement precision can reach 1.4 ppb for a 60 s averaging time. Continuous measurements covering a seven-day period were performed to demonstrate the stability and robustness of the reported CH 4 sensor system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗