Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAS SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Remote sensing of stratospheric and mesospheric winds by gas correlation electrooptic phase-modulation spectroscopy

A method is developed for directly measuring atmospheric winds in the 20-120 km altitude interval from a spacecraft. The wind sensor measures the Doppler shift between the spectral absorption lines of a gas in a cell within the instrument and the thermal emission lines of the same gas in the atmosphere. The wind measurements are performed using a spacecraft-borne gas correlation spectrometer viewing the limb of the atmosphere. The wind-induced Doppler shift between the two spectra, and thus the magnitude of the wind itself, is obtained by phase modulating the incoming thermal radiation (equivalent to frequency modulation) by means of an electrooptically active crystal to determine the frequency shift required to reestablish exact correlation between the lines in the cell and the lines from the atmosphere. Results of numerical simulations of the wind-sensor performance indicate that the noise-equivalent-wind is between 1-5 m/s over most of the stratosphere and mesosphere.

Mccleese, D. J.↗

Application of deep learning to single-shot gas-phase laser-induced breakdown spectroscopy

Single-shot fs laser-induced breakdown spectroscopy (LIBS) has the potential to capture ns-scale electrode desorption phenomena in pulsed power fusion drivers. However, the successful implementation of the diagnostic for this purpose is challenging, as it requires interpreting single-shot measurements collected from low-density gas mixtures. In this work, we demonstrate the efficacy of a Bayesian-optimized convolutional neural network (CNN) to interpret these measurements. We generated 256 distinct measurement conditions at relevant gas pressures ranging from 80–530 mTorr by mixing 100–250 sccm H 2 and 50–200 sccm CH 4 in increments of 10 sccm. Despite the considerable overlap between signals separated by 20 sccm, the CNN is able to predict the H 2 flow rate with a root-mean-square error (RMSE) of 15.9 sccm and the CH 4 flow rate with an RMSE of 12.0 sccm. The average relative prediction error is <9% for each gas and largely remains below or near 10%.

Brown, Nathan Parnell [Sandia National Lab. (SNL-N↗

Outgassing of Flown and Unflown MIR Solar Cells

A solar panel array with more than ten years space exposure was removed from the Mir core module in November 1997, and an eight panel section was returned to Earth in January 1998. Several solar cells were removed from panel eight of the returned array and placed in a high vacuum system with a residual gas analyzer (200 amu mass spectrometer) and a cold finger. Similar unflown solar cells of the same vintage were later obtained from Energia. Several of the unflown cells were also placed in the vacuum system and outgassed residues were collected on the LN2 cold finger. Almost 3 mg of outgassed residue was collected -from a string of three unflown solar cells over a period of 94 hours under vacuum. The collected residue was weighed with a microbalance, and then the residue was analyzed by FTIR spectroscopy, and by gas chromatograph-mass spectroscopy. About 25 outgassed constituents were separated by the gas chromatograph, and a high-resolution mass spectrum was obtained of each constituent. Molecular identifications have been made for the constituents. The constituents are primarily cyclic siloxanes, and several of the constituents are isomers of the same molecule. Most of the outgassed constituents have a molecular mass of about 500 amu. Almost one mg of residue was extracted from one sq cm of coverglass/adhesive from a flown solar cell by soaking in isopropyl alcohol for 30 minutes. The gas chromatograph separated about 20 constituents. The constituents are mostly cyclic siloxanes with linear branches, hydrocarbons, and phthalates. The typical molecular mass is about 600 amu. These identifications of specific outgassing molecules have resulted in a more complete understanding of the SiO(x) contamination on the Mir solar cell coverglasses, and on the MEEP experiment trays and optical specimens during the Shuttle-Mir Phase One flight experiment program. Adjusted outgassing rates based on the data reported here, and/or measured outgassing rates and specific molecular identifications of ISS hardware samples are needed to input into model predictions of induced environment effects of the ISS.

Harvey, Gale A.↗

On the Use of Fourier Transform Infrared (FT-IR) Spectroscopy and Synthetic Calibration Spectra to Quantify Gas Concentrations in a Fischer-Tropsch Catalyst System

One possible origin of prebiotic organic material is that these compounds were formed via Fischer-Tropsch-type (FTT) reactions of carbon monoxide and hydrogen on silicate and oxide grains in the warm, inner-solar nebula. To investigate this possibility, an experimental system has been built in which the catalytic efficiency of different grain-analog materials can be tested. During such runs, the gas phase above these grain analogs is sampled using Fourier transform infrared (FT-IR) spectroscopy. To provide quantitative estimates of the concentration of these gases, a technique in which high-resolution spectra of the gases are calculated using the high-resolution transmission molecular absorption (HITRAN) database is used. Next, these spectra are processed via a method that mimics the processes giving rise to the instrumental line shape of the FT-IR spectrometer, including apodization, self-apodization, and broadening due to the finite resolution. The result is a very close match between the measured and computed spectra. This technique was tested using four major gases found in the FTT reactions: carbon monoxide, methane, carbon dioxide, and water. For the ranges typical of the FTT reactions, the carbon monoxide results were found to be accurate to within 5% and the remaining gases accurate to within 10%. These spectra can then be used to generate synthetic calibration data, allowing the rapid computation of the gas concentrations in the FTT experiments.

Infrared Spectroscopy↗

Optical remote measurement of toxic gases

Enactment of the Clean Air Act Amendments (CAAA) of 1990 has resulted in increased ambient air monitoring needs for industry, some of which may be met efficiently using open-path optical remote sensing techniques. These techniques include Fourier transform spectroscopy, differential optical absorption spectroscopy, laser long-path absorption, differential absorption lidar, and gas cell correlation spectroscopy. With this regulatory impetus, it is an opportune time to consider applying these technologies to the remote and/or path-averaged measurement and monitoring of toxic gases covered by the CAAA. This article reviews the optical remote sensing technology and literature for that application.

Review↗

When Photoelectrons Meet Gas Molecules: Determining the Role of Inelastic Scattering in Ambient Pressure X-ray Photoelectron Spectroscopy

Inelastic photoelectron scattering (IPES) by gas molecules, a critical phenomenon observed in ambient pressure X-ray photoelectron spectroscopy (APXPS), complicates spectral interpretation due to kinetic energy loss in the primary spectrum and the appearance of additional features at higher binding energies. In this study, we systematically investigate IPES in various gas environments using APXPS, providing detailed insights into interactions between photoelectrons emitted from solid surfaces and surrounding gas molecules. Corelevel XPS spectra of Au, Ag, Zn, and Cu metals were recorded over a wide kinetic energy range in the presence of CO 2 , N 2 , Ar, and H 2 gases, demonstrating the universal nature of IPES across different systems. Additionally, we analyzed spectra of scattering effects induced by gas-phase interactions without metal solids. In two reported CO 2 -reduction systems (p-GaN/ Au/Cu and p-Si/TaO x /Cu), we elucidated that IPES is independent of the composition, structure, or size of the solid materials. Using metal foil platforms, we further developed an analytical model to extract electron excitation cross sections of gas molecules. These findings enhance our understanding of IPES mechanisms and enable the predictions of IPES structures in other solid–gas systems, providing a valuable reference for future APXPS studies and improving the accuracy of spectral analysis in gas-rich catalytic interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diode laser absorption sensors for gas-dynamic and combustion flows

Recent advances in room-temperature, near-IR and visible diode laser sources for tele-communication, high-speed computer networks, and optical data storage applications are enabling a new generation of gas-dynamic and combustion-flow sensors based on laser absorption spectroscopy. In addition to conventional species concentration and density measurements, spectroscopic techniques for temperature, velocity, pressure and mass flux have been demonstrated in laboratory, industrial and technical flows. Combined with fibreoptic distribution networks and ultrasensitive detection strategies, compact and portable sensors are now appearing for a variety of applications. In many cases, the superior spectroscopic quality of the new laser sources compared with earlier cryogenic, mid-IR devices is allowing increased sensitivity of trace species measurements, high-precision spectroscopy of major gas constituents, and stable, autonomous measurement systems. The purpose of this article is to review recent progress in this field and suggest likely directions for future research and development. The various laser-source technologies are briefly reviewed as they relate to sensor applications. Basic theory for laser absorption measurements of gas-dynamic properties is reviewed and special detection strategies for the weak near-IR and visible absorption spectra are described. Typical sensor configurations are described and compared for various application scenarios, ranging from laboratory research to automated field and airborne packages. Recent applications of gas-dynamic sensors for air flows and fluxes of trace atmospheric species are presented. Applications of gas-dynamic and combustion sensors to research and development of high-speed flows aeropropulsion engines, and combustion emissions monitoring are presented in detail, along with emerging flow control systems based on these new sensors. Finally, technology in nonlinear frequency conversion, UV laser materials, room-temperature mid-IR materials and broadly tunable multisection devices is reviewed to suggest new sensor possibilities.

Non-NASA Center↗

Laser absorption spectroscopy - Method for monitoring complex trace gas mixtures

A frequency stabilized CO2 laser was used for accurate determinations of the absorption coefficients of various gases in the wavelength region from 9 to 11 microns. The gases investigated were representative of the types of contaminants expected to build up in recycled atmospheres. These absorption coefficients were then used in determining the presence and amount of the gases in prepared mixtures. The effect of interferences on the minimum detectable concentration of the gases was measured. The accuracies of various methods of solution were also evaluated.

Green, B. D.↗

Miniature Gas Chromatograph (GC): Penning Ionization Electron Spectroscopy (PIES) Instrument for the Trace Analyses of Extraterrestrial Environments

In situ exploration of the solar system to identify its early chemistry as preserved in icy bodies and to look for compelling evidence of astrobiology will require new technology for chemical analysis. Chemical measurements in space flight environments highlight the need for a high level of positive identification of chemical compounds, since re-measurement by alternative techniques for confirmation will not be feasible. It also may not be possible to anticipate all chemical species that are observed, and important species may be present only at trace levels where they can be masked by complex chemical backgrounds. Up to now, the only techniques providing independent sample identification of GC separated components across a wide range of chemical species have been Mass Spectrometry (MS) and Ion Mobility Spectrometry (IMS). We describe here the development of a versatile and robust miniature GC detector based on Penning Ionization Electron Spectroscopy (PIES), for use with miniature GC systems being developed for planetary missions. PIES identifies the sample molecule through spectra related to its ionization potential. The combination of miniature GC technology with the primary identification capabilities of PIES provides an analytical approach ideal for planetary analyses.

Kojiro, Daniel R.↗

Real-time monitoring of trace noble gases using laser-induced breakdown spectroscopy—An investigation of the impact of bulk gas on plasma properties and sensitivity

The impact of Ar and He bulk gases on laser-induced breakdown spectroscopy (LIBS) real-time monitoring of trace Xe and Kr was assessed. LIBS is being developed as a monitoring tool for measuring noble gas transport in molten salt systems, in which traditional sensors may face challenges associated with radiation, corrosive materials, and/or mixed phases. The plasma temperature and electron densities of LIBS plasmas were measured in both static and various flowing Ar and He streams (0–5 L min −1 ). The use of an Ar bulk gas resulted in higher plasma temperature, greater electron densities by an order of magnitude, and extended plasma lifetime compared with when He bulk gas was used. Gas flow rate was found to have little impact on plasma temperature; however, its effect on electron density was significant, indicating the need to consider flow rate–specific models. Matrix effects on emission peaks were reported for both bulk gases. Due to these matrix effects, multivariate models were developed for Xe and Kr ranging from 0 to 700 ppm in both bulk gases. Although the predictive behavior was similar (root mean square error of prediction ranging from 11.1 to 20.6 ppm), the limits of detection were superior in He (Xe: 22.9 ppm, Kr: 30.4 ppm). Furthermore, these models were employed in demonstrative real-time tests (>1 h), which showed strong predictive precision (relative standard deviation <5 %) regardless of the bulk gas. Ultimately, this study provides a guide for the considerations required when developing gaseous LIBS models for real-time monitoring.

Gas flow effects↗

Discovering CO Adsorption and Desorption Pathways from Chemical Reaction Neural Network Modeling of Transient Kinetics Spectroscopy

Here, we demonstrate a data-driven approach to interpreting surface reactions by combining time-resolved gas pulsing infrared spectroscopy with chemical reaction neural networks (CRNNs). Using CO adsorption and desorption on Pd(111) at 460–490 K as a model system, we show how transient kinetic data can reveal detailed reaction mechanisms. Starting with a simple one-species model, we systematically evaluate increasingly complex mechanisms involving hollow and bridge site adsorption. Despite the similar goodness of fit to the same experimental absorbance data, our models predict distinct coverage dynamics for different adsorption sites. Through analysis of spectral peak stability and predicted dynamics, we identify a mechanism in which CO primarily adsorbs on bridge sites followed by rapid conversion to hollow sites as being the most physically consistent with experimental observations. This work provides a framework for extracting mechanistic insights from limited experimental data, demonstrating how machine learning can bridge the gap between transient kinetic measurements and a molecular-level understanding of surface reactions.

36 MATERIALS SCIENCE↗

Gas in Protoplanetary and Debris Disks: Insights from UV Spectroscopy

Over the last two decades, observations of protoplanetary and debris disks have played an important role in the new field of extrasolar planetary studies. Many are familiar with the extensive work on the cold circumstellar dust present in these disks done using infrared and sub-millimeter photometry and spectroscopy. However. UV spectroscopy has made some unique contributions by probing the elusive but vital gas component in protoplanetary and debris disks. In this talk, I will outline our picture of the evolution of protoplanetary disks and discuss the importance of the gas component. New insights obtained from UV spectroscopy will be highlighted, as well as some new puzzles. Finally, I will touch on upcoming studies of gas in protoplanetary and debris disks, some at UV wavelengths, some at far-IR and sub-mm wavelengths.

Roberge, Aki↗

A microwave plasma cleaning apparatus

In a microwave electron cyclotron resonance plasma source, reactive plasmas of oxygen and its mixtures of argon have been used for evaluating plasma cleaning technologies. Small aluminum samples (0.95 x 1.9 cm) were coated with thin films (less than or equal to 20 micrometers in thickness) of Shell Vitrea oil and cleaned with reactive plasmas. The discharge parameters, such as gas pressure, magnetic field, substrate biasing, and microwave power, were varied to change cleaning conditions. A mass spectroscopy (or residual gas analyzer) was used to monitor the status of plasma cleaning. Mass loss of the samples after plasma cleaning was measured to estimate cleaning rates. Measured cleaning rates of low-pressure (0.5-m torr) argon/oxygen plasmas were as high as 2.7 micrometers/min. X-ray photoelectron spectroscopy was used to determine cleanliness of the sample surfaces. In this paper, significant results of the plasma cleaning are reported and discussed.

Tsai, C. C.↗

Quantification of trace iodine using laser-induced breakdown spectroscopy for real-time monitoring of nuclear off-gas streams

This study evaluated the potential of laser-induced breakdown spectroscopy (LIBS) for real-time monitoring of trace gas-phase iodine, which is an element of high significance in nuclear applications due to its long radioactive half-life (as iodine-129), volatility, and biological impact. In anticipation of iodine evolving into off-gas systems in molten salt reactor and nuclear fuel recycling applications, this research aimed to assess LIBS performance in flowing argon and helium matrices; optimize measurement parameters using a multichannel spectrometer; and perform calibrations to assess predictive capabilities and limits of detection (LODs). Experimental results successfully measured gas-phase iodine in flowing argon and helium; however, trace iodine was not detected in air. Optimal delay times were determined to be 10 µs for argon and 1 µs for helium, which are consistent with the expected shorter plasma lifetime in helium relative to argon. An emission line survey was provided with the 206.16, 804.37, 902.24, and 905.83 nm peaks, which were identified as the strongest emission peaks. Calibration models were successfully built in both helium and argon, achieving LODs down to 3 ppm in helium and 5 ppm in argon. The iodine emission at 905.83 nm emerged as the most robust for calibration and was subsequently applied to a time series dataset in argon. The predictive trace confirmed the feasibility of employing LIBS for continuous, online quantification of trace iodine in flowing gas systems.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Integrated material-surface analyzer

These 10 surface-analysis tests can be run without breaking vacuum: secondary-ion mass spectroscopy, ion-scattering spectroscopy, electron-stimulated desorption, residual-gas analysis, auger electron spectroscopy, x-ray photoelectron spectroscopy, ultraviolet photoelectron spectroscopy, characteristic-electron energy-loss spectroscopy, scanning electron microscope, scanning low-energy electron probe. Quadruple mass spectrometer, used in first 4 tests, serves as electron transfer lens in last 6 tests.

Grunthaner, F. J.↗

Interstellar matter in early-type galaxies - Optical observations

Results of optical observations of 26 bright elliptical galaxies selected on the basis of IRAS data are discussed. Optical broadband imaging (using B and R filters) and narrow-band imaging (using H-alpha interference filters) have been performed to study dust patches and ionized gas. Long-split spectroscopy has also been made to determine gas kinematics and relative line ratios. The spectroscopic data confirm the presence and distribution of interstellar matter (dust lanes and ionized gas) seen in the direct imaging. Decoupled kinematics of interstellar gas and stars favors an external origin of the interstellar matter. However, for one isolated galaxy, an internal origin is not excluded. The rotation curves determined by optical emission lines are symmetric around the center in most galaxies observed. Galaxy masses and mass-to-light ratios are estimated using the rotation curves of the ionized gas.

Kim, Dong-Woo↗

The kinematics of the extended gas in the Seyfert galaxy NGC 3516

Long-slit spectroscopy of the extended gas in the Seyfert galaxy NGC 3516 reveals considerable substructure in the narrow emission lines with several kinematically distinct components visible in H-alpha and N II lambda 6583. The velocity measurements cover almost all of the 3 kpc scale, Z-shaped emission-line structure seen in narrow-band images and suggest that a significant rotational component is present. At large radii, strong deviations from this rotation are observed, indicating that a radial component of motion to the gas is also required to adequately describe the velocity field. There is a clear antisymmetry in these deviations with the velocities being blueshifted with respect to 'normal' galactic rotation on the southwest side of the nucleus and redshifted with respect to it on the northeast side. Although several models can be invoked to explain the observed velocities, the symmetries in the kinematics and emission-line morphology are most easily explained by a bent bipolar mass outflow from the nucleus. In this simple model, gas is ejected out of the plane of the stellar disk and is then slowed by gravitational forces. As the gas trajectory begins to bend, significant velocity deviations are produced. These observations provide some of the best kinematic evidence for mass outflow, although indirect arguments suggest they may be a common feature in many Seyfert galaxies.

Mulchaey, John S.↗