JTu3A.64 ? 1 Dielectric Metasurfaces made of Vertically Oriented Germanium Ellipses.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The presentation summarizes a project completed by our group a couple years ago comparing two detectors and attempting to normalize the results using a mathematical equation and how those results impacted our current operations.
Ionization produced by low-energy nuclear recoils is among the primary direct signatures of dark matter interactions. Despite the urgency of dark matter detection and the recent measurements of coherent elastic neutrino-nucleus scattering, detector response to nuclear recoils is not well characterized in the keVnr and sub-keVnr regime across a variety of materials. We have re-performed a measurement of the ionization produced by monoenergetic 254 eVnr nuclear recoils in Ge with improved digital electronics and additional systematic studies. Our results indicate an ionization yield of 64 +/- 8 eVee corresponding to a quenching factor of 25 +/- 3%, greater than the 14% predicted by the Lindhard model. This ionization enhancement could greatly improve the sensitivity of high-purity Ge detectors in dark matter detection and measurement of neutrinos via coherent scattering.
Methods for fabricating thin, high-aspect-ratio Ge nanostructures from high-quality, single-crystalline Ge substrates are provided. Also provided are grating structures made using the methods. The methods utilize a thin layer of graphene between a surface of a Ge substrate, and an overlying resist layer. The graphene passivates the surface, preventing the formation of water-soluble native Ge oxides that can result in the lift-off of the resist during the development of the resist.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
SNM verification can be accomplished via two methods i.e. destructive analysis (DA) or nondestructive analysis (NDA). The DA modes are much more accurate compared to NDA modes; nevertheless, the sample's physical integrity is destroyed in the process. Techniques such as ICP-MS, ID-ICP-MS, TI-MS are few examples of DA, where a bulk material is ground and mixed with a solution (some form of acid) to acquire a homogenous sample. In contrast, NDA modes utilize signals emitted by the sample such as gamma, neutrons, light, or heat to analyze samples under investigation. HPGe detectors are some of the most frequently used gamma detectors to assay SNM. However, in a high activity scenario it provides a large uncertainty and sometimes becomes unfeasible to measure low energy gamma rays. Meanwhile, neutron detectors are not affected by the gamma background, therefore they can be used in addition to the gamma detectors to verify total fissile mass ({sup 235}U + {sup 239}Pu) of SNM. The AWCC is one of the thermal neutron NDA systems developed at the Los Alamos National Laboratory (LANL). It consists of 42 {sup 3}He detectors to measure gross neutrons (singles), coincidence neutrons (doubles), higher order multiplicity counting (triples, quadruples, etc.). It can effectively operate in both active and passive neutron interrogation modes. It can utilize AmLi, AmBe, or {sup 252}Cf active interrogation neutron sources. It is used to verify declared fissile mass ({sup 235}U or {sup 239}Pu) present in SNM. Objectives: Calibrate HPGe and AWCC for lightly irradiated (with enough {sup 137}Cs gamma background) ∼93% enriched HEU fuels; Verify fissile mass ({sup 235}U +{sup 239}Pu) content using AWCC and HPGe; Model and benchmark AWCC in MCNP6. Neutron coincidence and multiplicity counting: Two or more neutrons are coincident if they are detected by the system within the specified gate window; In AWCC: Gate window is 128 μsec; Induced fission in fissile material such as {sup 235}U and {sup 239}Pu - emission of time correlated neutrons - Singles, Doubles, Triples, or Quadruples; No induced fission in non-fissile materials- no correlated neutrons - only singles. SNM can be verified with high accuracy and precision using gamma and neutron NDA instruments such as HPGe and AWCC. Interaction with thermal neutrons. Non-fissile atoms - do not emit correlated neutrons. Fissile atoms - emit correlated neutrons during induced fission events. The time correlated neutrons can be detected by using coincidence or multiplicity counters such as AWCC. Likewise, {sup 235}U produces 186 keV gamma peak that can be measured by a HPGe gamma detector. Counts under 186 keV gamma peak provide information about {sup 235}U content. Combining AWCC and HPGe results can provide better understanding of special nuclear material under investigation.
As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).
Methods for patterning highly sensitive materials, such as organic materials, organic semiconductors, biomolecular materials, and the like, with photolithographic resolution are disclosed. In some embodiments, a germanium mask (304) is formed on the surface of the sensitive material (302), thereby protecting it from subsequent processes that employ harsh chemicals that would otherwise destroy the sensitive material (302). A microlithography mask (306) is patterned on the germanium mask layer (304), after which the germanium exposed by the microlithography mask (306) is removed by dissolving it in water. After transferring the pattern of the germanium mask (304) into the sensitive material (302), the germanium and microlithography masks (304, 306) are completely removed by immersing the substrate in water, which dissolves the remaining germanium and lifts off the microlithography mask material. As a result, the only chemical to which the sensitive material (302) is exposed during the patterning process is water, thereby mitigating or avoiding damage to the material (302).
The physical properties of two-dimensional (2D) materials depend strongly on the number of layers. Hence, methods for controlling their thickness with atomic layer precision are highly desirable, yet still too rare, and demonstrated for only a limited number of 2D materials. Here we present a simple and scalable method for the continuous layer-by-layer thinning that works for a large class of 2D materials, notably layered germanium pnictides and chalcogenides. It is based on a simple oxidation/etching process, which selectively occurs on the topmost layers. Through a combination of atomic force microscopy, X-ray photoelectron spectroscopy, Raman spectroscopy and X-ray diffraction experiments we demonstrate the thinning method on germanium arsenide (GeAs), germanium sulfide (GeS) and germanium disulfide (GeS 2 ). We use first-principles simulation to provide insights into the oxidation mechanism. Our strategy, which could be applied to other classes of 2D materials upon proper choice of the oxidation/etching reagent, could pave the way for the realization of 2D material-based devices, such as electronic or optoelectronic ones, where a precise control over the number of layers (hence over the material’s physical properties) is needed. We also show that when used in combination with lithography, our method can be used to make precise patterns in the 2D materials.
Vitreous germanium disulfide GeS 2 and diselenide GeSe 2 belong to canonical chalcogenide glasses extensively studied over the past half century. Their high-temperature orthorhombic polymorphs are congruently melting compounds, and the tetrahedral crystal and glass structure is largely preserved in the melt. In contrast, the ditelluride counterpart is absent in the Ge-Te phase diagram, which shows only a single compound, monotelluride GeTe. Phase-change materials based on GeTe have become a technologically important class of solids, and their structure and properties are also widely studied. Surprisingly, very scarce information is available for alloys having GeTe 2 stoichiometry. Using a fast quenching procedure in silica capillaries, high-energy X-ray diffraction, and Raman spectroscopy supported by first-principles simulations, we show that bulk glassy GeTe 2 differs substantially from the lighter GeX 2 members, revealing 46% of trigonal germanium, 31% of three-fold coordinated tellurium, and only 20% of edge-sharing tetrahedra or pyramids. The fraction of homopolar Ge-Ge bonds is low; however, the population of dominant Te-Te dimers and Te n oligomers, n <= 10, appears to be significant. The complex structural and chemical topology of g-GeTe 2 is directly related to the thermodynamic metastability of germanium ditelluride, schematically represented by the following reaction: GeTe 2 $\rightleftarrows$ GeTe + Te. Disproportionation is complete above liquidus in the temperature range of semiconductor-metal transition, and the dense metallic GeTe 2 liquid, mostly consisting of five-fold coordinated Ge species, exhibits high fluidity, strong fragility (m = 99 ± 5), and presumably a fast structural transformation rate combined with low atomic mobility in the vicinity of the glass transition temperature, favorable for reliable long-term data retention in nonvolatile memories. The observed and predicted characteristic features make GeTe 2 a promising precursor for the next generation of phase-change materials, especially coupled with additional metal doping, depolymerizing the tetrahedral interconnected glass network and accelerating (sub)nanosecond crystallization.
The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to maximize the amount of information provided by these detectors, but the data-driven nature makes it less interpretable compared to traditional analysis. An interpretability study reveals the machine's decision-making logic, allowing us to learn from the machine to feedback to the traditional analysis. In this work, we have presented the first machine learning analysis of the data from the Majorana Demonstrator; this is also the first interpretable machine learning analysis of any germanium detector experiment. Two gradient boosted decision tree models are trained to learn from the data, and a game-theory-based model interpretability study is conducted to understand the origin of the classification power. By learning from data, this analysis recognizes the correlations among reconstruction parameters to further enhance the background rejection performance. By learning from the machine, this analysis reveals the importance of new background categories to reciprocally benefit the standard Majorana analysis. This model is highly compatible with next-generation germanium detector experiments like LEGEND since it can be simultaneously trained on a large number of detectors.
Here, we report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass ~500g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced inside of which was mounted a 25 mm diameter germanium inner target detector of mass ~10g. The detector was designed using inputs from a GEANT4 based simulation, where it was modeled to be sandwiched between two germanium detectors. The simulation showed that the background rates (dominated by gamma interactions) could be reduced by >90%, and that such an arrangement is sufficient for aggressive background reduction needed for neutrino and dark matter search experiments. Operating at mK temperatures at the experimental site, the veto detector prototype achieved a baseline resolution of 1.24±0.02 keV while hosting a functional inner target detector. The baseline resolution of the inner target detector was 147±2 eV. The experimental results of an identical detector arrangement are in excellent agreement with the simulation.