Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The High-Altitude Water Cherenkov (HAWC) observatory in México: The primary detector

The High-Altitude Water Cherenkov (HAWC) observatory is a second-generation continuously operated, wide field-of-view, TeV gamma-ray observatory. The HAWC observatory and its analysis techniques build on experience of the Milagro experiment in using ground-based water Cherenkov detectors for gamma-ray astronomy. HAWC is located on the Sierra Negra volcano in México at an elevation of 4100 meters above sea level. The completed HAWC observatory principal detector (HAWC) consists of 300 closely spaced water Cherenkov detectors, each equipped with four photomultiplier tubes to provide timing and charge information to reconstruct the extensive air shower energy and arrival direction. The HAWC observatory has been optimized to observe transient and steady emission from sources of gamma rays within an energy range from several hundred GeV to several hundred TeV. However, most of the air showers detected are initiated by cosmic rays, allowing studies of cosmic rays also to be performed. This paper describes the characteristics of the HAWC main array and its hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the gamma-ray emission from the core of the Sagittarius dwarf galaxy

ABSTRACT We use Fermi-LAT data to analyse the faint gamma-ray source located at the centre of the Sagittarius (Sgr) dwarf spheroidal galaxy. In the 4FGL-DR3 catalogue, this source is associated with the globular cluster, M54. We investigate the spectral energy distribution and spatial extension of this source, with the goal of testing two hypotheses: (1) the emission is due to millisecond pulsars within M54, or (2) the emission is due to annihilating dark matter from the Sgr halo. For the pulsar interpretation, we consider a two-component model which describes both the lower-energy magnetospheric emission and possible high-energy emission arising from inverse Compton scattering. We find that this source has a point-like morphology at low energies, consistent with magnetospheric emission, and find no evidence for a higher-energy component. For the dark matter interpretation, we find the signal favours a dark matter mass of mχ = 29.6 ± 5.8 GeV and an annihilation cross section of $\sigma v = (2.1 \pm 0.59) \times 10^{-26} \, \text{cm}^3$ s−1 for the $b \bar{b}$ channel (or mχ = 8.3 ± 3.8 GeV and $\sigma v = (0.90 \pm 0.25) \times 10^{-26} \, \text{cm}^3$ s−1 for the τ+τ− channel), when adopting a J-factor of $J=10^{19.6} \, \text{GeV}^2 \, \text{cm}^{-5}$. This parameter space is consistent with gamma-ray constraints from other dwarf galaxies and with dark matter interpretations of the Galactic Centre Gamma-Ray Excess.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiple emission components in the Cygnus cocoon detected from Fermi -LAT observations

Star-forming regions may play an important role in the life cycle of Galactic cosmic rays (CRs), notably as home to specific acceleration mechanisms and transport conditions. Gamma-ray observations of Cygnus X have revealed the presence of an excess of hard-spectrum gamma-ray emission, possibly related to a cocoon of freshly accelerated particles. We seek an improved description of the gamma-ray emission from the cocoon using ~13 yr of observations with the Fermi-Large Area Telescope (LAT) and use it to further constrain the processes and objects responsible for the young CR population. We developed an emission model for a large region of interest, including a description of interstellar emission from the background population of CRs and recent models for other gamma-ray sources in the field. Thus, we performed an improved spectro-morphological characterisation of the residual emission including the cocoon. The best-fit model for the cocoon includes two main emission components: an extended component FCES G78.74+1.56, described by a 2D Gaussian of extension r 68 = 4.4° ± 0.1° -0.1° +0.1° and a smooth broken power law spectrum with spectral indices 1.67 ± 0.05 -0.01 +0.02 and 2.12 ± 0.02 -0.01 +0.00 below and above 3.0 ± 0.6 -0.2 +0.0 GeV, respectively; and a central component FCES G80.00+0.50, traced by the distribution of ionised gas within the borders of the photo-dissociation regions and with a power law spectrum of index 2.19 ± 0.03 -0.01 +0.00 that is significantly different from the spectrum of FCES G78.74+1.56. An additional extended emission component FCES G78.83+3.57, located on the edge of the central cavities in Cygnus X and with a spectrum compatible with that of FCES G80.00+0.50, is likely related to the cocoon. For the two brightest components FCES G80.00+0.50 and FCES G78.74+1.56, spectra and radial-azimuthal profiles of the emission can be accounted for in a diffusion-loss framework involving one single population of non-thermal particles with a flat injection spectrum. Particles span the full extent of FCES G78.74+1.56 as a result of diffusion from a central source, and give rise to source FCES G80.00+0.50 by interacting with ionised gas in the innermost region. For this simple diffusion-loss model, viable setups can be very different in terms of energetics, transport conditions, and timescales involved, and both hadronic and leptonic scenarios are possible. The solutions range from long-lasting particle acceleration, possibly in prominent star clusters such as Cyg OB2 and NGC 6910, to a more recent and short-lived release of particles within the last 10–100 kyr, likely from a supernova remnant. The observables extracted from our analysis can be used to perform detailed comparisons with advanced models of particle acceleration and transport in star-forming regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

In situ observation of irradiation-induced enhancement to the desorption pressure of zirconium hydride in a nuclear reactor

We quantify the effect of a nuclear-reactor environment on the hydrogen isotope equilibrium vapor pressure over pure zirconium and zirconium hydride. A vacuum-sealed capsule containing a zirconium foil with 6 atom% deuterium was irradiated at a neutron flux of ~10 14 cm -2 s -1 at the University of Missouri Research Reactor (MURR). The internal stainless-steel (SS) sample holder acted as the heat source via gamma absorption. To measure low desorption pressures in a high-flux environment, we developed a method to transduce pressure from the measured sample temperature during irradiation, calibrating with known deuterium pressures in unirradiated capsules at various heating powers using an internal filament-heated system designed to mimic irradiation-induced heating. Our temperature-pressure transduction method operates similarly to a Pirani or thermocouple pressure gauge. The in-reactor measurements revealed a roughly 4-fold enhancement in desorption pressure after only 6 h of irradiation (~2 × 10 18 cm -2 neutron fluence) compared to thermal desorption in control experiments, indicating a nonthermal contribution from neutron irradiation. The slower temperature/pressure stabilization rate in the reactor suggests that desorption pressure enhancement increases with neutron fluence. Further, this enhancement signifies increased solubility of hydrogen isotopes in zirconium during irradiation. We propose that high-energy neutron collisions with hydrogen isotopes in hydrides lead to their decomposition at lower temperatures, supersaturating the surrounding αZr lattice and resulting in higher desorption pressure, which continues to rise as more hydrides dissolve with increasing neutron fluence.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photonuclear cross sections for the 197 Au ⁢(𝛾, 𝑝⁢𝑛)⁢ 195⁢𝑚 Pt reaction near threshold

Platinum radioisotopes are of growing interest for targeted cancer therapy and diagnostic imaging because their decay delivers highly localized radiation doses in tissue, herewith enabling precise DNA damage through Auger-electron emission. Developing production technologies that provide platinum isotopes with high specific activity is essential in radioisotope therapy. Photonuclear reactions on stable nuclei offer a viable accelerator-based route for isotope production when supported by reliable cross-section data. We report photonuclear cross-section measurements for the 197 Au(γ, pn) 195m Pt reaction at incident γ-ray energies of 27, 29, and 31 MeV using the activation method. The measurements were performed by irradiating a stack of concentric-ring gold targets with a quasi-monoenergetic γ-ray beam provided by the High Intensity Gamma-ray Source (HI γS). The induced 195m Pt activity was quantified using off-line γ-ray spectroscopy. These data provide the first experimental constraints on the 197 Au(γ, pn) 195m Pt cross section in the near-threshold region. Furthermore, the comparison of the measured excitation function to PHITS and TALYS calculations indicates that the reaction becomes measurable only near 30 MeV and that substantially higher bremsstrahlung end-point energies are required for practically meaningful production.

190 ≤ A ≤ 219↗

Measurement of the Li 7 ( γ , t ) He 4 ground-state cross section between E γ = 4.4 and 10 MeV

Here, the Li 7 ( γ , t ) He 4 ground state cross section was measured for the first time using monoenergetic γ rays with energies between 4.4 and 10 MeV at the High Intensity Gamma-ray Source. The reaction is important for the primordial Li problem and for testing our understanding of the mirror α -capture reactions H 3 ( α , γ ) Li 7 and He 3 ( α , γ ) Be 7 . Although over the last 30 years most measurements of the H 3 ( α , γ ) Li 7 reaction have concentrated in an energy range below E γ = 3.65 MeV, measurements at higher energies could potentially restrict the extrapolation to astrophysically important energies. The experimental arrangement for measuring the Li 7 ( γ , t ) He 4 reaction included a large-area silicon detector array and several beam characterization instruments. The experimental astrophysical S factor of H 3 ( α , γ ) calculated from the present data was fitted using the R -matrix formalism. The results are in disagreement with previous experimental measurements in the same energy range but the extrapolated S factor agrees with the potential model calculation and lower energy experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Testing shell-model interactions at high excitation energy and low spin: Nuclear resonance fluorescence in Ge 74

With their complex low-spin structure, the germanium isotopes have accrued a large number of experimental data which challenge nuclear models. The structure of the 74 Ge isotope is investigated here with nuclear resonance fluorescence as part of an extensive campaign of experimental tests of the shell model in the germanium isotopic chain using a number of complementary techniques. Levels were excited with 3.10 – 5.44 MeV photon beams provided by the High Intensity Gamma-Ray Source at TUNL. Many new levels were identified and their spins, parities, branching ratios, and associated scattering cross section values were determined. Large-scale shell-model calculations, which include jj44b and JUN45 effective interactions developed to describe nuclei in this mass region, predict the new data satisfactorily. Herein this study extends the validation of these two interactions, which are candidates for computation of matrix elements to be used in the interpretation of neutrinoless double-β decay experiments in 76 Ge, into the low-spin, high excitation energy domain.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photonuclear cross sections for 197 Au: An update on the gold standard

Cross sections for the 197 Au(γ, n) reaction are broadly used in nuclear physics as a standard for normalizing photonuclear reaction cross-section data at photon beam energies above approximately 8 MeV. In this paper, we report cross-section measurements for the 197 Au(γ, n) 196 Au g+m1 reaction at beam energies from 13 to 31 MeV. Our measurements provide the first cross-section data for this reaction at beam energies above 20 MeV, enabling the use of this reaction as a cross-section standard up to 30 MeV. Also, this work provides first cross-section measurements for the 197 Au(γ, n) 196 Au m2 reaction. In addition, we measured cross-section data for the 197 Au(γ, 3n) 194 Au reaction, which can be used as a cross-section standard above about 25 MeV. These measurements were performed using a new target activation method that is based on the angle-energy correlation of the laser Compton- scattered photon beams at the High Intensity Gamma-ray Source (HIγS). The technique enables measuring photonuclear reaction cross-sections at several discrete beam energies concurrently via a single irradiation on a stack of different targets. Measurements were carried out by irradiating a stack of concentric-ring targets consisting of Au, TiO 2 , Zn, Os, and Au (in order of the γ-ray beam direction). Our data for the 197 Au(γ,n) 196 Au g+m1 reaction in the energy range of 13 to 20 MeV are in good agreement with existing ones measured using monoenergetic γ-ray beams, but differ from data acquired using a bremsstrahlung γ-ray beam. Also, above 18 MeV, our data for the 197 Au(γ,n) 196 Au g+m1 and 197 Au(γ,n) 196 Au m2 reactions differ significantly from the most recent TENDL and JENDL evaluations, suggesting a need to update these data libraries. Furthermore, the TENDL evaluation and existing data are consistent with our data for the 197 Au(γ,3n) reaction, but differ significantly from the JENDL evaluation above 26 MeV.

190 ≤ A ≤ 219↗

Proton Compton Scattering from Linearly Polarized Gamma Rays

In this work, differential cross sections for Compton scattering from the proton have been measured at scattering angles of 55°, 90°, and 125° in the laboratory frame using quasimonoenergetic linearly (circularly) polarized photon beams with a weighted mean energy value of 83.4 MeV (81.3 MeV). These measurements were performed at the High Intensity Gamma-Ray Source facility at the Triangle Universities Nuclear Laboratory. The results are compared to previous measurements and are interpreted in the chiral effective field theory framework to extract the electromagnetic dipole polarizabilities of the proton, which gives $α^p_{E1} = 13.8 ± 1.2_{\text{stat}} ± 0.1_{\text{BSR}} ± 0. 3_{\text{theo}} , β^p_{M1} = 0.2 ∓ 1. 2_{\text{stat}} ± 0. 1_{\text{BSR}} ∓ 0. 3_{\text{theo}}$ in units of $10^{–4}$ fm$^3$ .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Total-Ionizing-Dose Resistant Data Storing Technique for NAND Flash Memory

This paper describes a new non-charge-based data storing technique in NAND flash memory called watermark that encodes read-only data in the form of physical properties of flash memory cells. Unlike traditional charge-based data storing method in flash memory, the proposed technique is resistant to total ionizing dose (TID) effects. To evaluate its resistance to irradiation effects, we analyze data stored in several commercial single-level-cell (SLC) flash memory chips from different vendors and technology nodes. These chips are irradiated using a Co-60 gamma-ray source array for up to 100 krad(Si) at Sandia National Laboratories. Experimental evaluation performed on a flash chip from Samsung shows that the intrinsic bit error rate (BER) of watermark increases from 0.8% for TID = 0 krad(Si) to 1% for TID = 100 krad(Si). Conversely, the BER of charge-based data stored on the same chip increases from 0% at TID = 0 krad(Si) to 1.5% at TID = 100 krad(Si). Overall, the results imply that the proposed technique may potentially offer significant improvements in data integrity relative to traditional charge-based data storage for very high radiation (TID > 100 krad(Si)) environments. These gains in data integrity relative to the charge-based data storage are useful in radiation-prone environments, but they come at the cost of increased write times and higher BERs before irradiation.

36 MATERIALS SCIENCE↗

Radiation-Induced Error Mitigation by Read-Retry Technique for MLC 3-D NAND Flash Memory

Here, we have evaluated the Read-Retry (RR) functionality of the 3-D NAND chip of multilevel-cell (MLC) configuration after total ionization dose (TID) exposure. The RR function is typically offered in the high-density state-of-the-art NAND memory chips to recover data once the default memory read method fails to correct data with error correction codes (ECCs). In this work, we have applied the RR method on the irradiated 3-D NAND chip that was exposed with a Co-60 gamma-ray source for TID up to 50 krad (Si). Based on our experimental evaluation results, we have proposed an algorithm to efficiently implement the RR method to extend the radiation tolerance of the NAND memory chip. Our experimental evaluation shows that the RR method coupled with ECC can ensure data integrity of MLC 3-D NAND for TID up to 50 krad (Si).

3-D NAND↗

Total-Ionizing-Dose Effects on Long-term Data Retention Characteristics of Commercial 3-D NAND Memories

This article evaluates the data retention characteristics of irradiated multi-level cell (MLC) 3-D NAND flash memories. We irradiate the memory chips by a Co-60 gamma-ray source for up to 50 krad(Si) and then write a random data pattern on the irradiated chip to find its retention characteristics. The experimental results show that the data retention property of the irradiated chips is significantly degraded compared to the un-irradiated ones. We evaluate two independent strategies to improve the data retention characteristics of the irradiated chips. Furthermore, the first method involves high-temperature annealing of the irradiated chip while the second method suggests pre-programming the memory modules before deploying them in radiation-prone environments.

3-D NAND flash↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗

Connecting Nuclear Structure to Stellar Astrophysics: Neutron Skin in Tin Isotopes

The first observation of a neutron star merger by the LIGO-Virgo collaboration in 2017 highlights the need to improve our fundamental understanding of the equation of state of dense, neutron rich matter. The origin of heavy elements in the r-process and the structure of neutron stars are governed by the properties of neutron rich matter, for which experimental data is limited. Further analysis of this historic event and all future neutron star mergers relies on constraining the nuclear equation of state with experimental observables. We propose a novel method for systematically studying the evolution of the neutron skin in stable tin isotopes, by measuring the low-energy nuclear dipole strength over the broadest possible range of neutron-to-proton ratios in a single element. Nuclear resonance fluorescence with 100% linearly polarized photons from the High Intensity Gamma-ray Source (HIGS) facility was used to selectively measure the E1 photoabsorption strength of 112 Sn and 124 Sn at excitation energies from 3.5 MeV up to neutron separation, where the Pygmy Dipole Resonance dominates. The dipole polarizabilities of 112 Sn and 124 Sn were measured to be 9.03 ± 0.23 fm 3 and 9.11 ± 0.24 fm 3 , respectively. These uniquely systematically consistent measurements provide highly accurate experimental data for improving microscopic nuclear models as well as calculations of astrophysical nucleosynthesis and neutron star structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of Anomalies in Environmental Gamma Radiation Background with Hopfield Artificial Neural Network - Consortium on Nuclear Security Technologies (CONNECT) Q3 Report

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to investigate performance of a Hopfield Neural Network (HNN) in in detection and identification of weak nuisances and anomalies events in the presence of a highly fluctuating background. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign. One data set contained a 137 Cs source, and another dataset contained a 131 I source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗