At least 127 records · Page 7

Electroluminescence Yield Measurements in Xenon Gas with the NEXT-DEMO++ Detector

The NEXT-DEMO++ detector, a high-pressure xenon gas time projection chamber serving as a prototype for the NEXT-100 experiment, was used to measure the electroluminescence (EL) yield as a function of reduced electric field ($E/p$) across pressures from 2.0 to 9.4 bar, utilizing the 41.5 keV de-excitation peak of $^{83m}$Kr. These measurements were made to examine the pressure dependence of the slope of the reduced EL yield $Y/p$, which has shown inconsistencies in the literature. The reduced yield was fitted with a linear model, revealing a modest ($\sim$5%) change in slope, beginning around 5 bar and increasing with pressure up to 9.4 bar.

Renner, J. [Valencia U., IFIC]↗

Measurement of isosteric heat of gas adsorption and Brunauer–Emmett–Teller (BET) surface area using a quartz crystal microbalance

The study of gas adsorption on a solid surface evaluates the affinity between sorbate gas and sorbent substrate and factors that contribute to this. This report presents a test platform for adsorption experiments of various gases on various solid surfaces. Controlled environmental conditions enable investigations in materials surface science and increase the consistency among adsorption data. The system utilizes a quartz crystal microbalance to perform gravimetric analysis of deposition and adsorption, enabling investigation of the interaction of gaseous molecules with solid surfaces. In this study, a quartz crystal microbalance as gas adsorption detector was integrated with an environmental chamber to create a versatile tool for gas adsorption experiments on thin films. Experimental operation of this apparatus was demonstrated via acquisition of the adsorption isotherms of cyclohexane vapor on a gold surface at 55 and 70 °C. The result indicated International Union of Pure and Applied Chemistry Type II adsorption. Consequentially, application of the Brunauer–Emmett–Teller model to the isotherm data subject to predefined criteria for linear region selection yielded a surface area of the sorbent of 0.53 cm2 at 55 °C. From the monolayer region of the isotherms, the isosteric heat of adsorption of the cyclohexane vapor on gold was calculated to be 37 kJ mol-1.

47 OTHER INSTRUMENTATION↗

Properties of states near 𝐸 𝑥 = 6 MeV in 18 Ne through 17 F +𝑝 scattering

The rate of energy production in the hot-CNO cycle and breakout to the rapid-proton capture process in Type I X-ray bursts is strongly related to the 14 O⁡(𝛼,𝑝)⁢ 17 F reaction rate. The properties of states in 18 Ne near 𝐸 𝑥 = 6.1–6.3 MeV are important for understanding the 14 O⁡(𝛼,𝑝)⁢ 17 F reaction rate. In order to study 18 Ne resonances around this energy region, the RESOLUT radioactive-ion beam facility at Florida State University was used to perform 17 F⁡(𝑝,𝑝)⁢ 17 F elastic scattering on a polypropylene target under inverse kinematics. Scattered protons were detected in a silicon-strip detector array while recoiling 17 F ions were detected in coincidence in a gas ionization detector. An 𝑅-matrix analysis of measured cross sections was conducted along with a reanalysis of data from previous 17 F +𝑝 measurements. All the data analyzed are well described by a consistent set of parameters with a 1 − assignment for a state at 6.14(1) MeV. A second comparable solution is also found with a 3 − assignment for the 6.14(1) MeV state. There is no conclusive evidence supporting one of the two solutions over the other. The rates of the 14 O⁡(𝛼,p)⁢ 17 F reaction that are determined from the two solutions differ by up to an order of magnitude.

6 ≤ A ≤ 19↗

Kryptonate Hydrogen Detection System (Final Report)

A prototype model of a multipurpose instrument which demonstrates the applicability of the Kryptonate® technique for detecting hydrogen gas was developed. This report describes the construction of the instrument and presents a laboratory evaluation of its performance. Performance was excellent. The instrument was designed to detect hydrogen in air at concentrations of 0-3% by volume, and to detect hydrogen in nitrogen or other inert gas at concentrations of 0-10% by volume. Other detection levels (both higher and lower) could be set if required. Ultimate response times can be made of the order of 0.5 seconds. The instrument is an all solid state device operating from 120V 60 Hz power source. The instrument has been designed to enable modifications to be made with a minimum amount of difficulty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy resolution and gain measurements in Argon-based gas mixtures: Exploring Ar:CF 4 for low energy measurements with TPCs

Time Projection Chambers (TPCs) are among the most advanced charged-particle detectors. Gas-filled TPCs have tracking capabilities that provide 3D-imaging of charged particles with a good energy resolution for spectroscopy. Different gas mixtures have different properties that determine the energy resolution as well as the spatial resolution. Therefore, optimization of operating conditions is required to simultaneously obtain adequate gain, energy resolution, spatial/track resolution, as well as higher drift velocities for high counting rates applications. Ar:CF 4 gas mixture has higher electron drift velocities and lower electron diffusion, which makes it an attractive candidate for TPC filling gas for low energy nuclear physics applications as compared to commonly used Ar:CH 4 and Ar:CO 2 gas mixtures, namely when tracking information is needed. However, other properties, including energy resolution and gain, remain largely unexplored in Ar:CF 4 especially at pressures and other operating conditions relevant for low-energy nuclear physics applications. Here, in this paper we report on gain and energy resolution measurements, using Gas Electron Multipliers (GEMs), in the less explored Ar:CF 4 mixture (Alfonsi et al., 2006), as well as in the more commonly used gas mixtures Ar:CH 4 and Ar:CO 2 . In addition to obtaining energy resolution and gain, we provide results from Garfield++ simulations for gain fluctuations, and their impact on energy resolution is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the CMS detector for the CERN LHC Run 3

Since the initial data taking of the CERN LHC, the CMSexperiment has undergone substantial upgrades and improvements. Thispaper discusses the CMS detector as it is configured for the thirddata-taking period of the CERN LHC, Run 3, which started in2022. The entire silicon pixel tracking detector was replaced. A newpowering system for the superconducting solenoid was installed. Theelectronics of the hadron calorimeter was upgraded. All the muonelectronic systems were upgraded, and new muon detector stationswere added, including a gas electron multiplier detector. Theprecision proton spectrometer was upgraded. The dedicated luminositydetectors and the beam loss monitor were refurbished. Substantialimprovements to the trigger, data acquisition, software, andcomputing systems were also implemented, including a new hybridCPU/GPU farm for the high-level trigger.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved nondispersive infrared analyzer

Light from radiant energy source passes through filter, sample, and reference gas chambers to detector. Chamber with amount of gas to be measured is sealed. Filter may be gelatinous, interference, dispersive, or negative-gas, as required.

Dimeff, J.↗

XIPE the X-Ray Imaging Polarimetry Explorer

X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017. The proposal was, unfortunately, not selected. To be compliant with this schedule, we designed the payload mostly with existing items. The XIPE proposal takes advantage of the completed phase A of POLARIX for an ASI small mission program that was cancelled, but is different in many aspects: the detectors, the presence of a solar flare polarimeter and photometer and the use of a light platform derived by a mass production for a cluster of satellites. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus. Two additional GPDs filled with a 3-bar Ar-DME mixture always face the Sun to detect polarization from solar flares. The Minimum Detectable Polarization of a 1 mCrab source reaches 14 in the 210 keV band in 105 s for pointed observations, and 0.6 for an X10 class solar flare in the 1535 keV energy band. The imaging capability is 24 arcsec Half Energy Width (HEW) in a Field of View of 14.7 arcmin 14.7 arcmin. The spectral resolution is 20 at 6 keV and the time resolution is 8 s. The imaging capabilities of the JET-X optics and of the GPD have been demonstrated by a recent calibration campaign at PANTER X-ray test facility of the Max-Planck-Institut fr extraterrestrische Physik (MPE, Germany). XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil). The data policy is organized with a Core Program that comprises three months of Science Verification Phase and 25 of net observing time in the following 2 years. A competitive Guest Observer program covers the remaining 75 of the net observing time.

Astronomy X-ray Polarimetry↗

133Xe Noble Gas Mass Spectrometry Measurement for High Purity Germanium Detector Performance Verification

Idaho National Laboratory produces quality control standards for laboratories that operate xenon radionuclide monitoring systems. Activities reported with each quality control standard are quantified using high purity germanium detectors. A collection of measurement capabilities are being set up at Idaho National Laboratory to establish an in-house high purity germanium detector performance verification system, with noble gas mass spectrometry being one of these measurement capabilities. The first noble gas mass spectrometry and high purity germanium measurement comparison is presented here. A Xe-133 gas sample was prepared and the activity was quantified with high purity germanium detectors. The Xe-133 sample was diluted with a known quantity of isotopically enriched Xe-126 gas; the resulting Xe-133 : Xe-126 atom ratio was calculated to be 1.15x10-4 +/- 2% at reference time t. An aliquot of this gas sample containing approximately 10 million Xe-133 atoms was introduced into a ThermoFisher Scientific Helix MC Plus noble gas mass spectrometer for analysis. The measured Xe-133 : Xe-126 atom ratio was determined to be 1.10x10-4 +/- 2% (1-sigma uncertainty) at reference time t, about 4.3% lower than the atom ratio determined with the measured high purity germanium activity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Coupling of TIGRESS and EMMA with Auxiliary Array TIP at TRIUMF

The combination of a germanium detector array and recoil mass spectrometer allows for high-sensitivity experiments in nuclear structure and astrophysics by enabling high-energy-resolution -ray spectroscopy and reaction measurements of weak fusion-evaporation, transfer or radiative-capture reactions in the presence of dominant background reaction channels. The TIGRESS -ray spectrometer with an upgraded data acquisition system has been coupled with the EMMA mass spectrometer alongside a suite of auxiliary detectors housed within TIGRESS such as TIP. This paper reviews the unique combination of radioactive beams at TRIUMF with the capabilities of TIGRESS and EMMA in the context of fusion-evaporation with TIP and radiative-capture reactions without an auxiliary array.

A/Q identification↗

Milestone 2.7: Evaluation of Techniques for the Measurement of Molecular Hydrogen Gas in Helium Matrices

Published data by Task 2 (Oxyhydroxide Layer Radiolytic Gas Generation Resolution) for Technical Considerations and Challenges for Extended (>50 yrs) Dry Storage of Aluminum Cladded Spent Nuclear Fuel (ASNF), demonstrated that radiolytic molecular hydrogen (H2) production from gamma irradiated aluminum alloy 1100 (Al-1100) coupons exhibited significant dependence on backfill gaseous environment conditions: air, due to the presence of oxygen, completely inhibited H2 production; nitrogen promoted H2 production; and argon yielded more H2 than nitrogen environments. The concern here is that helium has been proposed as the backfill gas for extended storage and is more inert than argon, which may translate into significantly more H2 production than current Task 3 argon-based models predict. However, the measurement of H2 in helium media was not possible using the previously establish gas chromatography (GC) flame ionization detector, due to similarities in thermal conductivity. This milestone was initiated to evaluate an alternative GC approach that employed a mercuric oxide (HgO) reduction gas detector (RGD). Using the HgO RGD setup, H2 was successfully calibrated in the presence of a helium carrier gas, and then subsequently measured in control and irradiated crush-tube sample vials, consistent with previous sample measurements. Overall, the HgO RGD approach was found to be sufficient for future helium environment irradiations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF 4 . Initially, pure CF 4 will be used, and then in mixtures containing other elements employed by leading dark matter search technologies — including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process — an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF 4 we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D–D (D–T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5σ median discovery significance can be achieved in under one day with either generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-pulse time resolved gamma ray spectroscopy of the advanced radiographic capability using gas Cherenkov diagnostics

The advanced radiographic capability located at the National Ignition Facility (NIF) uses high intensity, short pulse lasers to create bright photon sources for diagnosing high energy density experiments. There are radiographic needs for a multi-frame time-resolved MeV gamma diagnostic for experiments on the NIF with sub-nanosecond resolution. A series of experiments demonstrated measurements of MeV x-ray spectra resolved with a time separation of a few nanoseconds through the use of gas Cherenkov detectors. In this work, a two-pulse radiographic experiment found a 30% reduction in > 2.8 MeV photon flux compared to the first frame exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of multi neutron-to-gamma converter array for measuring time resolved ion temperature of inertial confinement fusion implosions

The ion temperature varying during inertial confinement fusion implosions changes the amount of Doppler broadening of the fusion products, creating subtle changes in the fusion neutron pulse as it moves away from the implosion. A diagnostic design to try to measure these subtle effects is introduced—leveraging the fast time resolution of gas Cherenkov detectors along with a multi-puck array that converts a small amount of the neutron pulse into gamma-rays, one can measure multiple snapshots of the neutron pulse at intermediate distances. Further, precise measurements of the propagating neutron pulse, specifically the variation in the peak location and the skew, could be used to infer time-evolved ion temperature evolved during peak compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of fusion reaction history in inertially confined burning plasmas

Direct evidence of inertially confined fusion ignition appears in the abrupt temperature increase and consequent rapid increase in the thermonuclear burn rate as seen in the reaction history. The Gamma Reaction History (GRH) and Gas Cherenkov Detector (GCD) diagnostics are γ-based Cherenkov detectors that provide high quality measurements of deuterium–tritium fusion γ ray production and are, thus, capable of monitoring the thermonuclear burn rate. Temporal shifts in both peak burn time and burn width have been observed during recent high-yield shots (yields greater than 1017 neutrons) and are essential diagnostic signatures of the ignition process. While the current GRH and GCD detectors are fast enough to sense the changes of reaction history due to alpha heating, they do not have enough dynamic range to capture the onset of alpha heating. The next generation of instrumentation, GRH-15m, is proposed to increase the yield-rate coverage to measure the onset of alpha-heating.

42 ENGINEERING↗

C 13 ( n , 2 n γ ) C 12 γ -ray production in the 14–16 MeV incident neutron energy range

We report γ-ray emission from 12 C and 13 C samples irradiated with deuterium-tritium fusion neutrons was experimentally measured at the Omega Laser Facility and at the Ohio University Edwards Accelerator Laboratory. The intent of these measurements was to determine the feasibility of using 13 C-based plastic ablators with embedded 12 C layers for “dark mix” diagnosis of inertial confinement fusion implosions. Spectrally resolved measurements at Ohio University identified significant 4.44-MeV γ-ray emission from the 13 C(n, 2nγ) 12 C-L1 reaction channel. The recorded 4.44-MeV 13 C signal was compared against emission from an identically irradiated 12 C target with known 12 C(n, n'γ) 12 C-L1 cross section, which resulted in an average 13 C(n, 2nγ) 12 C-L1 cross section of 117 ± 17 mb over the incident neutron energy distribution range from 14.4 to 15.8 MeV. Integrated 13C γ -ray signals above 2.9 MeV recorded with the Gas Cherenkov Detector at Omega exceeded MCNP6.1 predictions by a factor of 3. The additional signal was attributed to 4.44-MeV γs resulting in an inferred 13 C(n, 2nγ) 12 C-L1 cross section of 95 ± 11 mb at 14.1-MeV average incident neutron energy. As a result, the 13 C-based “dark mix” diagnostic concept was deemed infeasible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗