The CLAS12 Forward Tagger

This document presents the technical layout and the performance of the CLAS12 Forward Tagger (FT). The FT, composed of an electromagnetic calorimeter based on PbWO$_4$ crystals (FT-Cal), a scintillation hodoscope (FT-Hodo), and several layers of Micromegas trackers (FT-Trk), has been designed to detect electrons and photons scattered at polar angles from 2$^\circ$ to 5$^\circ$ and to meet the physics goals of the hadron spectroscopy program and other experiments running with the CLAS12 spectrometer in Hall B.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning and operation in magnetic field of CMS GE1/1 station

In October and November 2021 the CMS Gas Electron Multiplier (GEM) detectors of station GE1/1 were operated for the first time in presence of a magnetic field in CMS. The phenomena observed in this first period led to performing a test on GE1/1 chambers to study their behaviour in presence of a magnetic field ramp. The magnetic field has been created using the Goliath magnet installed in the CERN North Area. In conclusion, the aim of the test is to determine if a magnetic field ramp causes serious problems to the operation of the GEM chambers and to develop a clear set of procedures, that will permit the safe operations of the GEM chambers during a magnetic field ramp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conversion of Phenolic Oil from Biomass Pyrolysis into Phenyl Esters

Bio-oil is among the most economical approaches for advanced biofuel production. However, bio-oil faces several challenges including high acidity and viscosity, poor storage, and thermal stability. This study focuses on the upgradation of lignocellulosic (corn stover and yellow pine) bio-oil derived phenolic oil (PO), produced by the autothermal fast pyrolysis, through acid-catalyzed esterification reaction. Our strategy exploits a little recognized chemistry: the Fischer esterification of PO and carboxylic acids into carboxylic acid phenyl esters (CAPE) using Dean Stark distillation. Analyses by the Folin–Ciocalteu method, Karl Fischer titration, gas chromatography flame ionization detector, and the molecular weight determination by gel permeation chromatography suggest the conversion of 50 wt% added phenolics to their corresponding CAPE. The Fourier transform infrared spectroscopy analysis confirmed the formation of new C=O and two C–O stretching bands and decrease in the intensity of phenolic-OH bands in the CAPE. The 13 C NMR analysis supports the formation of CAPE together with some unreacted precursors. A base-catalyzed ester hydrolysis experiment and mass balance calculation show an excellent agreement (within 5% range) of the equivalent weight between the produced ester and the phenyl hexanoate. Brookfield analysis indicates that CAPE has 330-fold lower viscosity than starting PO. Heating values of CAPE were higher than PO, from which they were derived (42.2 and 43.6%, respectively, for PO from pyrolysis of corn stover and yellow pine), while moisture content decreased by 98.3 and 98.7%, respectively. The CAPE, which is a phenolic analogue of methyl esters used in biodiesel, has improved stability compared to PO from which it was derived.

42 ENGINEERING↗

The upgrade of the ALICE TPC with GEMs and continuous readout

The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous readout electronics based on the SAMPA chip, an ALICE development, are replacing the previous elements. The construction of these new elements, together with their associated quality control procedures, is explained in detail. Finally, the readout chamber and front-end electronics cards replacement, together with the commissioning of the detector prior to installation in the experimental cavern, are presented. After a nine-year period of R&D, construction, and assembly, the upgrade of the TPC was completed in 2020.

47 OTHER INSTRUMENTATION↗

Inertial-confinement fusion-plasma-based cross-calibration of the deuterium-tritium γ-to-neutron branching ratio

The deuterium-tritium (D-T) γ -to-neutron branching ratio [ H 3 ( d , γ ) He 5 / H 3 ( d , n ) He 4 ] has been determined previously under inertial-confinement fusion (ICF) conditions and in beam-target based experiments. In the former case, neutron-induced backgrounds are mitigated compared to the latter due to the short pulse nature of ICF implosions and the use of gas Cherenkov γ -ray detectors. Furthermore, an added benefit of ICF based measurements is the ability to achieve lower center-of-mass energies as compared to accelerators. Previous ICF based experiments however report a large uncertainty in the D-T γ -to-neutron branching ratio of ≈ 48 % , which arises from the necessity of an absolute detector calibration and/or a cross-calibration against the D- He 3 γ -to-proton branching ratio. A more precise value for the branching ratio based on data taken at the OMEGA laser facility is reported here, which relies on a cross-calibration against the better known C 12 neutron inelastic scattering cross section. A D-T branching ratio value of ( 4.6 ± 0.6 ) × 10 - 5 is determined by this method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches

We report that large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay (0νββ) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas- or liquid-phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomena. The key challenge to extending this technology to detectors well beyond the ton scale is the acquisition of the Xe itself. We describe the motivation for extending Xe time-projection chambers to the kton scale and possible avenues for Xe acquisition that avoid existing supply chains. If acquisition of Xe in the required quantities is successful, kton-scale detectors of this type could enable a new generation of experiments, including searches for 0νββ at half-life sensitivities as long as 10 30 yr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasma enhanced atomic layer deposition and atomic layer etching of gallium oxide using trimethylgallium

Atomic layer etching driven by self-limiting thermal reactions has recently been developed as a highly conformal and isotropic technique for low damage atomic scale material removal by sequential exposures of vapor phase reactants. Gallium oxide (Ga2O3) is currently among the materials of interest due to a large variety of applications including power electronics, solar cells, gas sensors, and photon detectors. In this study, Ga2O3 was deposited by plasma enhanced atomic layer deposition using trimethylgallium [TMG, Ga(CH3)3] and O2 plasma at a substrate temperature of 200 °C. We report a newly developed method for Ga2O3 thermal atomic layer etching, in which surface modification is achieved through HF exposure resulting in a gallium fluoride surface layer, and then removed through volatile product formation via ligand exchange with TMG. Saturation of the precursor exposure at a substrate temperature of 300 °C resulted in an etch rate of 1.0 ± 0.1 Å/cycle for amorphous Ga2O3. Uniformity and conformality of the atomic layer etching process were confirmed via atomic force microscopy with a measured surface roughness of 0.55 ± 0.05 nm that remains unchanged after etching. The use of TMG for etching may expand available precursors for atomic layer etching processes, while allowing for both etching and deposition of Ga2O3 using the same metalorganic precursor.

Hatch, Kevin A. (ORCID:0000000283118623)↗

Development of Thin Gap GEM-µRWELL Hybrid Detectors at Jefferson Lab

Over the past few decades, Micro Pattern Gaseous Detector (MPGD) technologies have been increasingly adopted as tracking detector options in High Energy and Nuclear Physics experiments thanks to their good spatial resolution, high-rate capability, stability and more importantly their ability for large area coverage at a relatively low cost compared to the alternative. The thin gap GEM-µRWELL hybrid detector is the latest addition to the MPGD family, that was introduced to vastly improve the spatial resolution capability of gaseous trackers when deployed in the barrel region to cover large angular acceptance of the central tracker in a collider experiment. In this talk, I will re-introduce the concept and motivation for the development of thin gap GEM-µRWELL hybrid technology with an emphasis on the initial studies that establish the proof-of-concept of the technology. I will then discuss the more recent results from latest beam test campaign at Jefferson Lab in May 2025 to study detector efficiency performance with various gas mixtures. I will also briefly present the ongoing activities to develop large area thin gap GEM-µRWELL tracking detectors for the ePIC experiment of the future Electron Ion Collider as well as the exploration of the technology to provide large area tracking options to the muon system of experiments at a future Higgs Factory Collider such as the FCC-ee for example. Finally, I will conclude with some perspectives on new ideas under exploration to develop the next generation of thin gap MPGD technologies with enhanced timing and spatial resolution capabilities

Gnanvo, Kondo [Thomas Jefferson National Accelerat↗

System and method for determining absolute carrier-envelope phase of ultrashort laser pulses

A system for determining an absolute carrier-envelope phase (CEP) of ultrashort laser pulses includes a laser system for generating a laser beam including ultrashort optical pulses of a duration of less than 10 fs, an ultrabroadband quarter-wave plate configured to polarize the laser beam, and a gas jet emitting a continuous jet stream into the laser beam. The system includes focusing optics to adjust a focal spot of the laser beam to the gas jet, and a detector arrangement including a beam block and a microchannel plate (MCP) imaging detector, wherein the laser beam is directed to the detector arrangement. The method involves using angular streaking to determine the absolute CEP of both elliptically and linearly polarized light.

Li, Wen↗

A Measurement of the Neutron Electromagnetic Form Factor Ratio from a Rosenbluth Technique with Simultaneous Detection of Neutrons and Protons

The internal structure of protons and neutrons provides insight into both the dynamical behavior of the constitute quarks and gluons, and emergent properties of the nucleons (such as mass, spin, and electromagnetic distributions). Elastic electron-nucleon scattering can probe the elastic electromagnetic form factors of the nucleon. The electric and magnetic form factors, respectively, encode information about the internal charge and magnetization distributions within the nucleon. Precision data for these form factors, over a broad range of the four-momentum transfer squared, Q^2, can benchmark theoretical models describing the strong interaction of nuclear physics. The Super BigBite Spectrometer (SBS) program in Hall A at Jefferson Lab, is a series of high-precision experiments which seek to significantly extend the Q^2 reach of previous data for the nucleon electromagnetic form factors. The first two experiments of this program are known as G_M^n and the neutron Two Photon Exchange (nTPE) and the data were collected from October 2021 to February 2022. Both experiments were conducted with the simultaneous measurement of D(e,e'n) and D(e,e'p) reactions for quasi-elastic electron-deuteron scattering. The scattered electrons were detected in the BigBite Spectrometer, which features multiple large-acceptance Gas Electron Multiplier (GEM) detectors. The Super BigBite Spectrometer provided simultaneous detection of scattered nucleons, and utilized a large acceptance dipole magnet and Hadron Calorimeter (HCal). The G_M^n experiment provides precision measurements of the neutron magnetic form factor, via the ratio method, over a Q^2 range of 3.0 to 13.5 (GeV/c)2. From this data analysis, preliminary values for G_M^n/µ_n G_D are extracted. For Q^2=4.48 (GeV/c)2 we find G_M^n/µ_n G_D=0.9546±0.0132 and for Q^2=4.476 (GeV/c)2 we find G_M^n/µ_n G_D=0.9563±0.0110. These preliminary G_M^n/µ_n G_D values are more precise than existing world data in this Q^2 regime and are consistent with the most recent parameterization of the G_M^n/µ_n G_D world data. The nTPE experiment provides a first measurement of the neutron Rosenbluth Slope and seeks to quantify the two-photon exchange(TPE) contribution to elastic electron-neutron scattering at a fixed Q^2=4.5 (GeV/c)2 with two different beam energies and scattering angle values. For data of the proton form factor ratio, µ_p G_E^p/G_M^p, significant discrepancies exist between values obtained from Rosenbluth Separation and polarization transfer measurement, particularly at large Q^2, and TPE contributions are thought to resolve this discrepancy. The impacts of TPE contributions have not yet been experimentally established for the neutron. From the data analysis presented in this dissertation, a preliminary result for the neutron Rosenbluth Slope is found as S^n=(G_E^n )^2/t_n (G_M^n )^2=0.0916±0.0476 for Q^2=4.48 (GeV/c)2. This value of the neutron Rosenbluth Slope is consistent with the world data extrapolation and the absence of large TPE corrections.

Wertz, Ezekiel [Thomas Jefferson National Accelera↗

Performance of the ATLAS RPC detector and Level-1 muon barrel trigger at √(s)=13 TeV

The ATLAS experiment at the Large Hadron Collider (LHC) employs a trigger system consisting of a first-level hardware trigger (L1) and a software-based high-level trigger. The L1 muon trigger system selects muon candidates, assigns them to the correct LHC bunch crossing and classifies them into one of six transverse-momentum threshold classes. The L1 muon trigger system uses resistive-plate chambers (RPCs) to generate the muon-induced trigger signals in the central (barrel) region of the ATLAS detector. The ATLAS RPCs are arranged in six concentric layers and operate in a toroidal magnetic field with a bending power of 1.5 to 5.5 Tm. The RPC detector consists of about 3700 gas volumes with a total surface area of more than 4000 m2. This paper reports on the performance of the RPC detector and L1 muon barrel trigger using 60.8 fb-1 of proton-proton collision data recorded by the ATLAS experiment in 2018 at a centre-of-mass energy of 13 TeV. Detector and trigger performance are studied using Z boson decays into a muon pair. Measurements of the RPC detector response, efficiency, and time resolution are reported. Measurements of the L1 muon barrel trigger efficiencies and rates are presented, along with measurements of the properties of the selected sample of muon candidates. Measurements of the RPC currents, counting rates and mean avalanche charge are performed using zero-bias collisions. Finally, RPC detector response and efficiency are studied at different high voltage and front-end discriminator threshold settings in order to extrapolate detector response to the higher luminosity expected for the High Luminosity LHC.

47 OTHER INSTRUMENTATION↗

Commercially available Hydrogen Detection Systems for Corrosive, Oxygen-free Gas Streams: A Technical Summary

The growing use of hydrogen gas across energy, transportation, and chemical applications necessitates better hydrogen sensors and detectors. Few sensors exist for quantifying hydrogen gas in a corrosive, oxygen-free gas stream due to the challenging nature of the sampling environment and current technological status. Handheld, economic options include palladium-based, metal oxide, catalytic bead, and electrochemical sensors. More permanent and costly options include electrochemical sensors, thermal gas analyzers, mass spectrometers, gas chromatographs, and Raman spectrometers. In this technical report, a short review of current technology, along with the associated commercially available products, is provided. Raman spectroscopy is recommended as an ideal technology for on-line detection of hydrogen at low concentrations in a corrosive, oxygen-free gas stream.

08 HYDROGEN↗

Development of a new CEDAR for kaon identification at the NA62 experiment at CERN

The NA62 experiment at CERN utilises a differential Cherenkov counter with achromatic ring focus (CEDAR) for tagging kaons within an unseparated monochromatic beam of charged hadrons. The CEDAR-H detector was developed to minimise the amount of material in the path of the beam by using hydrogen gas as the radiator medium. The detector was shown to satisfy the kaon tagging requirements in a test-beam before installation and commissioning at the experiment. The CEDAR-H performance was measured using NA62 data collected in 2023.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning for single-ended event reconstruction in PROSPECT experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, was a segmented antineutrino detector that successfully operated at the High Flux Isotope Reactor in Oak Ridge, TN, during its 2018 run. Despite challenges with photomultiplier tube base failures affecting some segments, innovative machine learning approaches were employed to perform position and energy reconstruction, and particle classification. This work highlights the effectiveness of convolutional neural networks and graph convolutional networks in enhancing data analysis. By leveraging these techniques, a 3.3% increase in effective statistics was achieved compared to traditional methods, showcasing their potential to improve analysis performance. Furthermore, these machine learning methodologies offer promising applications for other segmented particle detectors, underscoring their versatility and impact.

47 OTHER INSTRUMENTATION↗

Primary track recovery in high-definition gas time projection chambers

Abstract We develop and validate a new algorithm called primary track recovery () that effectively deconvolves known physics and detector effects from nuclear recoil tracks in gas time projection chambers (TPCs) with high-resolution readout. This gives access to the primary track charge, length, and vector direction (helping to resolve the “head-tail” ambiguity). Additionally, provides a measurement of the transverse and longitudinal diffusion widths, which can be used to determine the absolute position of tracks in the drift direction for detector fiducialization. Using simulated helium recoils in an atmospheric pressure TPC with a 70:30 mixture of $$\hbox {He:CO}_2$$ He:CO 2 we compare the performance of to traditional methods for all key track variables. We find that the algorithm reduces reconstruction errors, including those caused by charge integration, for tracks with mean length-to-width ratios 1.4 and above, corresponding to recoil energies of 20 keV and above in the studied TPCs. We show that improves on existing methods for head-tail disambiguation, particularly for highly inclined tracks, and improves the determination of the absolute position of recoils on the drift axis via transverse diffusion. We find that can partially recover charge structure integrated out by the detector in the z direction, but that its determination of energy and length have worse resolution compared to existing methods. We use experimental data to qualitatively verify these findings and discuss implications for future directional detectors at the low-energy frontier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correction of the baseline fluctuations in the GEM-based ALICE TPC

To operate the ALICE Time Projection Chamber in continuous mode during the Run 3 and Run 4 data-taking periods of the Large Hadron Collider, the multi-wire proportional chamber-based readout was replaced with gas-electron multipliers. As expected, the detector performance is affected by the so-called common-mode effect, which leads to significant baseline fluctuations. A detailed study of the pulse shape with the new readout has revealed that it is also affected by ion tails. Since reconstruction and data compression are performed fully online, these effects must be corrected at the hardware level in the FPGA-based common readout units. The characteristics of the common-mode effect and of the ion tail, as well as the algorithms developed for their online correction, are described in this paper. The common-mode dependencies are studied using machine-learning techniques. Toy Monte Carlo simulations are performed to illustrate the importance of online corrections and to investigate the performance of the developed algorithms.

47 OTHER INSTRUMENTATION↗