Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gaseous detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

116 records · Page 7

FPMS_XPeRT_INL_Poster

As nuclear energy expands and experimental programs increasingly rely on the facilities at Idaho National Laboratory (INL) for reactor and fuel testing, research capabilities must also expand to meet these demands. A new Fission Product Monitoring System (FPMS) has been deployed at the Advanced Test Reactor (ATR) at the Auxiliary Lead-out Experiment (ALE) House to support this expanding fuel testing mission. By tracking gaseous fission products releases from test fuel in near real-time, release rates, calculated from FPMS data, can be used to characterize the effectiveness of fuel cladding, especially for Tri-structural Isotropic (TRISO) fuel concepts. The new iteration of the FPMS supports up to 14 fission product monitors for online fission-product tracking via gamma-ray spectroscopy of the experiment’s effluent gas. Each monitor consists of a nominally 10% HPGe detector housed in a copper-lined lead shield with a warm gas trap. The new system features gamma-ray count rate information with a five-second temporal resolution and provides isotopic activity every five minutes, capable of resolving multiple overlapping fission product releases over a broad range of activities in near real-time. This work includes data from ATR cycle 175D data to demonstrate these capabilities. The hourly resolution data shows general trends and significant releases over the cycle, while the 5-minute resolution data allows for a more detailed examination of events due to unexpected particle releases.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING↗

Milestone 2.7: Evaluation of Techniques for the Measurement of Molecular Hydrogen Gas in Helium Matrices

Published data by Task 2 (Oxyhydroxide Layer Radiolytic Gas Generation Resolution) for Technical Considerations and Challenges for Extended (>50 yrs) Dry Storage of Aluminum Cladded Spent Nuclear Fuel (ASNF), demonstrated that radiolytic molecular hydrogen (H2) production from gamma irradiated aluminum alloy 1100 (Al-1100) coupons exhibited significant dependence on backfill gaseous environment conditions: air, due to the presence of oxygen, completely inhibited H2 production; nitrogen promoted H2 production; and argon yielded more H2 than nitrogen environments. The concern here is that helium has been proposed as the backfill gas for extended storage and is more inert than argon, which may translate into significantly more H2 production than current Task 3 argon-based models predict. However, the measurement of H2 in helium media was not possible using the previously establish gas chromatography (GC) flame ionization detector, due to similarities in thermal conductivity. This milestone was initiated to evaluate an alternative GC approach that employed a mercuric oxide (HgO) reduction gas detector (RGD). Using the HgO RGD setup, H2 was successfully calibrated in the presence of a helium carrier gas, and then subsequently measured in control and irradiated crush-tube sample vials, consistent with previous sample measurements. Overall, the HgO RGD approach was found to be sufficient for future helium environment irradiations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

AGR-5/6/7 Final Release-to-Birth Ratio Data Analysis

AGR-5/6/7 is the last of a series of Advanced Gas Reactor (AGR) experiments conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) in support of development and qualification of tristructural isotropic (TRISO) low-enriched fuel for use in the high-temperature gas cooled reactor (HTGR). AGR configuration and irradiation conditions are based on prismatic HTGR technology that is distinguished primarily through the use of helium coolant, a low-power-density ceramic core capable of withstanding very high temperatures, and TRISO-coated particle fuel. The AGR tests provide valuable irradiation-performance data to support fuel process development, qualify fuel for normal operation and accident conditions, and support development and validation of fuel performance and fission-product (FP) transport models and codes. Each AGR test consists of multiple independently controlled and monitored capsules containing fuel compacts placed in a graphite cylinder shrouded by a steel shell. Release-to-birth ratios (R/B) for fission-gas isotopes released from each capsule are calculated from release rates, measured by germanium detectors in the Fission Product Monitoring System (FPMS) installed downstream from each capsule, and birth rates calculated using numerical models of FG generation. The R/Bs are a critical measure of the ability of the fuel kernel, the particle coating layers, and the compact matrix to retain fission-gas atoms, preventing their release into the sweep-gas flow, and the impact of initially defective particles and/or particle-coating failures that occur during irradiation. For fission-gas isotopes, particle failure is defined as failure of all coating layers, allowing gaseous fission atoms to escape from a particle. During the first five cycles (162B ? 165A), R/Bs were stable in the 10-8?10-6 range, and no in-pile particle failures were observed, based on the gross gamma counts. The maximum R/B value of around 2 ? 10-6 for Kr-85m resulted from the presence of as-fabricated exposed kernels (based on the high exposed kernel fraction), the dispersed uranium, and high fuel particle temperatures in Capsule 1. Comparison of capsule-measured R/Bs from these early cycles to predictions using the previously developed AGR R/B model demonstrated FG release from the AGR-5/6/7 TRISO fuel was comparable to that of previous experiments. In addition, the Kr-85m R/B per-exposed-kernel values are comparable to R/B values obtained in AGR-3/4 irradiation experiment and four irradiation experiments performed during 1980s: (1) HRB-17/18, (2) COMEDIE-BD1, (3) HFR B1, and (4) HRB-21. In contrast, all measured R/B values are lower than predictions by the commonly used Richards and German models, which are intentionally conservative. A large number of in-pile particle failures occurred in Capsule 1 by the end of Cycle 166A. During the final four cycles (166A ? 168A), apparent damage to the Capsule 1 gas line appeared to cause FG leakage from that capsule into the other four capsules, resulting in an increase in fission gas (FG) detected in the effluent for all capsules. Isolation of the Capsule 1 gas line during the last three cycles also prevented measurement of its FG release. Thus, R/Bs in all capsules after Cycle 166A are highly uncertain because of undefined amount of leakage from Capsule 1, especially for long-lived isotopes. A few hundred in-pile particle failures were estimated for Capsule 1 before the end of Cycle 166A, but the total number of failures is unknown due to the lack of FG release data in the later cycles. Based primarily on evidence from the gross gamma counts during Cycle 168A, approximately 15 particles failed in Capsule 3 and four particles failed in Capsule 2. In-pile failures in Capsule 3 were anticipated because this capsule was designed to operate beyond the HTGR normal operating temperature range. In contrast, no in-pile failures were identified in the top two capsules (4 and 5) based on the absence of the typical spikes in gross gamma counts and low failure estimates using the AGR model, developed in INL/EXT-14-32970, for R/B of the short-lived isotopes (Kr-89 and Xe-137) with minimal leakage from Capsule 1.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions

NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. Furthermore, the electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Projection Chambers instrumented with resistive MicroMegas for the SAND near detector of DUNE

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino accelerator experiment aiming for precise measurements of the neutrino oscillation parameters. DUNE will include a near detector complex regrouping three different detectors among which SAND (System for on-Axis Neutrino Detection) that will be the only one permanently on the neutrino beam axis in charge of monitoring in detail the emitted neutrino beam and its stability through time, a crucial characteristic to realize accurate oscillation measurements at the percent level. SAND will reuse the superconducting magnet and the electromagnetic calorimeter of the KLOE experiment. We will describe in the following the proposal of using, as inner tracker of SAND, a large 3D matrix of 1.5cm side scintillator cubes (3DST) surrounded by 3 gaseous Time Projection Chambers. This setup allows to realize accurate beam monitoring combining the 3DST unprecedented capability of neutron detection and energy measurement with the high precision momentum resolution for charged particles offered by the TPCs. The proposed TPC design allows to reach spatial resolutions of a few hundreds of micrometers using 1 cm pads by deploying the resistive MicroMegas technology for the charge readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operation modes of the KATRIN experiment Tritium Loop System using 83m Kr

The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to search for the effective electron antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.). In order to achieve this goal, KATRIN measurement phases focusing on the neutrino mass search are alternated with phases of investigations of systematic effects. During these phases, metastable 83m Kr is used as a calibration source. The monoenergetic conversion electrons emitted accompanying the decay of 83m Kr allow a direct access to the starting conditions of β-electrons produced inside the windowless gaseous tritium source (WGTS) of KATRIN. To make use of 83m Kr in the WGTS, the Tritium Loop System, which provides a stable flow of tritium to the WGTS, needs to be operated in special modes. This paper focuses on the technical implementation of these modes and their performance with regard to the achievable 83m Kr-rates, gas densities, and gas compositions inside the WGTS.

47 OTHER INSTRUMENTATION↗

Quantifying fission yields at the National Ignition Facility using depleted uranium foil experiments

There are programs for high-Z shell experiments at the National Ignition Facility (NIF). For shells made of actinide material, a quantitative fission diagnostic is needed in order to determine how much fission took place and whether the fission was sufficient to produce a non-negligible heat source in the burning capsule. Here, we present a viable coupled experimental and theoretical technique for making quantitative fission measurements possible. The proposed scheme involves using a well-characterized set of depleted uranium foils outside an NIF capsule to verify the conversion of xenon and krypton fission fragments collected at the Radiochemical Analysis of Gaseous Samples (RAGS) facility into total fission yield. We present the calculations needed for this conversion, including the decays in and out of fission fragment chains during the RAGS pump-down of the NIF chamber.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗