Search NASA⌕ Search

SEARCH · Search NASA

Results for “Geant4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Photon-rejection power of the Light Dark Matter eXperiment in an 8 GeV beam

The Light Dark Matter eXperiment (LDMX) is an electron-beam fixed-target experiment designed to achieve comprehensive model independent sensitivity to dark matter particles in the sub-GeV mass region. An upgrade to the LCLS-II accelerator will increase the beam energy available to LDMX from 4 to 8 GeV. Using detailed GEANT4-based simulations, we investigate the effect of the increased beam energy on the capabilities to separate signal and background, and demonstrate that the veto methodology developed for 4 GeV successfully rejects photon-induced backgrounds for at least 2 × 10 14 electrons on target at 8 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Generative Models for Fast Photon Shower Simulation in ATLAS

The need for large-scale production of highly accurate simulated event samples for the extensive physics programme of the ATLAS experiment at the Large Hadron Collider motivates the development of new simulation techniques. Building on the recent success of deep learning algorithms, variational autoencoders and generative adversarial networks are investigated for modelling the response of the central region of the ATLAS electromagnetic calorimeter to photons of various energies. The properties of synthesised showers are compared with showers from a full detector simulation using GEANT4 . Both variational autoencoders and generative adversarial networks are capable of quickly simulating electromagnetic showers with correct total energies and stochasticity, though the modelling of some shower shape distributions requires more refinement. This feasibility study demonstrates the potential of using such algorithms for ATLAS fast calorimeter simulation in the future and shows a possible way to complement current simulation techniques.

97 MATHEMATICS AND COMPUTING↗

Antihelium-3 sensitivity for the GRAMS experiment

The Gamma-Ray and AntiMatter Survey (GRAMS) is a next-generation balloon/satellite mission utilizing a Liquid Argon Time Projection Chamber (LArTPC) detector to measure both MeV gamma rays and antinuclei produced by dark matter annihilation or decay. The GRAMS can identify antihelium-3 events based on the measurements of X-rays and charged pions from the decay of the exotic atoms, Time of Flight (TOF), energy deposition, and stopping range. This paper shows the antihelium-3 sensitivity estimation using a GEANT4 Monte Carlo simulation. For the proposed long-duration balloon (LDB) flight program (35 days x 3 flights) and future satellite mission (2-year observation/10-year observation), the sensitivities become 1.47 × 10 −7 [m 2 s sr GeV/n] −1 and 1.55 × 10 −9 [m 2 s sr GeV/n] −1 /3.10 x 10 -10 [m 2 s sr GeV/n] −1 , respectively. The results indicate that GRAMS can extensively investigate various dark matter models through the antihelium-3 measurements.

Antihelium-3↗

Simulating low-energy neutrino interactions with MARLEY

Monte Carlo event generators are a critical tool for the interpretation of data obtained by neutrino experiments. Several modern event generators are available which are well-suited to the GeV energy scale used in studies of accelerator neutrinos. However, theoretical modeling differences make their immediate application to lower energies difficult. In this paper, I present a new event generator, MARLEY, which is designed to better address the simulation needs of the low-energy (tens of MeV and below) neutrino community. The code is written in C++14 with an optional interface to the popular ROOT data analysis framework. The current release of MARLEY (version 1.2.0) emphasizes simulations of the reaction 40 Ar ( ν e , e − ) 40 K ⁎ but is extensible to other channels with suitable user input. This paper provides detailed documentation of MARLEY's implementation and usage, including guidance on how generated events may be analyzed and how MARLEY may be interfaced with external codes such as Geant4. Further information about MARLEY is available on the official website at http://www.marleygen.org. Program title:MARLEY 1.2.0 CPC Library link to program files:https://doi.org/10.17632/4v7zxnc8j3.1 Developer's respository link:http://github.com/MARLEY-MC/marley Code Ocean capsule:https://codeocean.com/capsule/9868179 Licensing provisions: GNU General Public License 3.0 Programming language: C++14 External routines/libraries used: GNU Scientific Library [1,2] (required), ROOT [3,4] (optional) Nature of problem: Simulation of neutrino-nucleus scattering events at energies of tens-of-MeV and below Solution method: Initial two-to-two scattering kinematics are sampled using the allowed approximation differential cross section and tables of precomputed nuclear matrix elements. Subsequent de-excitations of the remnant nucleus are simulated using a Monte Carlo implementation of the Hauser-Feshbach statistical model and tabulated γ-ray decay schemes for discrete nuclear levels. Additional comments including restrictions and unusual features: Input data are provided with the code that are suitable for producing simulations of the charged-current reaction 40 Ar ( ν e , e − ) 40 K ⁎ , coherent elastic neutrino-nucleus scattering on spin-zero target nuclei, and neutrino-electron elastic scattering on any atomic target. Preparation of new reaction input files (whose format is documented in Appendix B) would enable other reaction channels and nuclear targets to be handled by the existing code framework. Although there is no maximum neutrino energy enforced by the code itself, realistic neutrino-nucleus scattering events may be generated up to roughly 50 MeV. Above this energy, the effects of forbidden nuclear transitions, which are neglected in the current treatment of the cross sections (see section 2.1), become increasingly important.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TPCpp-10M: Simulated proton-proton collisions in a time projection chamber for AI foundation models

Scientific foundation models hold great promise for advancing nuclear and particle physics by improving analysis precision and accelerating discovery. Yet, progress in this field is often limited by the lack of openly available large scale datasets, as well as standardized evaluation tasks and metrics. Furthermore, the specialized knowledge and software typically required to process particle physics data pose significant barriers to interdisciplinary collaboration with the broader machine learning community. This work introduces a large, openly accessible dataset of 10 million simulated proton-proton collisions, designed to support self-supervised training of foundation models. To facilitate ease of use, the dataset is provided in a common NumPy format. In addition, it includes 70,000 labeled examples spanning three well defined downstream tasks: track finding, particle identification, and noise tagging, to enable systematic evaluation of the foundation model's adaptability. The simulated data are generated using the Pythia Monte Carlo event generator at a center of mass energy of $\sqrt{s}$ = 200 GeV and processed with Geant4 to include realistic detector conditions and signal emulation in the sPHENIX Time Projection Chamber at the Relativistic Heavy Ion Collider, located at Brookhaven National Laboratory. This dataset resource establishes a common ground for interdisciplinary research, enabling machine learning scientists and physicists alike to explore scaling behaviors, assess transferability, and accelerate progress toward foundation models in nuclear and high energy physics. The complete simulation and reconstruction chain is reproducible with the sPHENIX software stack. All data and code locations are provided under Data Accessibility.

Data Analysis, Statistics and Probability (physics↗

Preliminary results in using Deep Learning to emulate BLOB, a nuclear interaction model

Purpose: A reliable model to simulate nuclear interactions is fundamental for Ion-therapy. We already showed how BLOB (“Boltzmann-Langevin One Body”), a model developed to simulate heavy ion interactions up to few hundreds of MeV/u, could simulate also 12 C reactions in the same energy domain. However, its computation time is too long for any medical application. For this reason we present the possibility of emulating it with a Deep Learning algorithm. Methods: The BLOB final state is a Probability Density Function (PDF) of finding a nucleon in a position of the phase space. We discretised this PDF and trained a Variational Auto-Encoder (VAE) to reproduce such a discrete PDF. As a proof of concept, we developed and trained a VAE to emulate BLOB in simulating the interactions of 12 C with 12 C at 62 MeV/u. To have more control on the generation, we forced the VAE latent space to be organised with respect to the impact parameter (b) training a classifier of b jointly with the VAE. Results: In this work, the distributions obtained from the VAE are similar to the input ones and the computation time needed to use the VAE as a generator is negligible. Conclusions: We show that it is possible to use a Deep Learning approach to emulate a model developed to simulate nuclear reactions in the energy range of interest for Ion-therapy. We foresee the implementation of the generation part in C++ and to interface it with the most used Monte Carlo toolkit: Geant4.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and performance of a silicon–tungsten calorimeter prototype module and the associated readout

Here, we describe the details of a silicon–tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance of a custom ASIC designed for fast, lower-power, high-granularity applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reaction losses of charged particles in CsI(Tl) crystals

To efficiently detect energetic light charged particles, it is common to use arrays of energy-loss telescopes involving two or more layers of detection media. As the energy of the particles increases, thicker layers are usually needed. However, carrying out measurements with thick-telescopes may require corrections for the losses due to nuclear reactions induced by the incident particles on nuclei within the detector and for the scattering of incident particles out of the detector, without depositing their full energy in the active material. In this paper, we develop a method for measuring such corrections and determine the reaction and out-scattering losses for data measured with the silicon-CsI(Tl) telescopes of the newly developed HiRA10 array. Here, the extracted efficiencies are in good agreement with model predictions using the GEANT4 reaction loss algorithm for Z = 1 and Z = 2 isotopes. After correcting for the HiRA10 geometry, we obtain a general function that describes the loss of efficiency due to reaction losses in CsI(Tl) crystals as a function of range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel active veto prototype detector with an inner target for improved rare event searches

Here, we report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass ~500g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced inside of which was mounted a 25 mm diameter germanium inner target detector of mass ~10g. The detector was designed using inputs from a GEANT4 based simulation, where it was modeled to be sandwiched between two germanium detectors. The simulation showed that the background rates (dominated by gamma interactions) could be reduced by >90%, and that such an arrangement is sufficient for aggressive background reduction needed for neutrino and dark matter search experiments. Operating at mK temperatures at the experimental site, the veto detector prototype achieved a baseline resolution of 1.24±0.02 keV while hosting a functional inner target detector. The baseline resolution of the inner target detector was 147±2 eV. The experimental results of an identical detector arrangement are in excellent agreement with the simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECCE sensitivity studies for single hadron transverse single spin asymmetry measurements

Here, we performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in pythia6 and geant4 simulated e+p collisions at 18 GeV on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector configuration. Typical DIS kinematics were selected, most notably Q 2 >1 GeV 2 , and cover the x range from 10 -4 to 1. The single spin asymmetries were extracted as a function of x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton, and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. They are obtained in azimuthal moments in combinations of the azimuthal angles of the hadron transverse momentum and transverse spin of the nucleon relative to the lepton scattering plane. In order to extract asymmetries, the initially unpolarized MonteCarlo was re-weighted in the true kinematic variables, hadron types and parton flavors based on global fits of fixed target SIDIS experiments and e + e – annihilation data. The expected statistical precision of such measurements is extrapolated to 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. Similar neutron information is obtained by comparing the ECCE e+p pseudo-data with the same from the EIC Yellow Report and scaling the corresponding Yellow Report e+ 3 He pseudo-data uncertainties accordingly. The impact on the knowledge of the Sivers functions, transversity and tensor charges, and the Collins function has then been evaluated in the same phenomenological extractions as in the Yellow Report. Finally, the impact is found to be comparable to that obtained with the parametrized Yellow Report detector and shows that the ECCE detector configuration can fulfill the physics goals on these quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The LSU-Argonne conversion electron spectrometer: A new detector for the X-Array and SATURN decay station

In this study, a new conversion electron detector has been commissioned at the ATLAS/ CARIBU facility at Argonne National Laboratory. The LSU-Argonne Conversion Electron Spectrometer (LACES) is a LN 2 -cooled Si(Li) detector system designed to be incorporated into a decay station that comprises the dedicated HPGe clover array with a box geometry (X -Array) and the Scintillator and Tape Using Radioactive Nuclei (SATURN) device. This integration enables simultaneous measurements of conversion electrons and gamma-rays in decay experiments, yielding novel information on transition multipolarities, electric monopole transitions, and isomeric states that decay mostly via conversion electrons. A measurement of the energy resolution of LACES yielded 2.3-keV FWHM at 975 keV for electrons and 1.3-keV FWHM at 75 keV for X-rays. A detailed study of the absolute detection efficiency (at 5 mm from the source) was performed, where this quantity was determined experimentally in the range of electron transition energies between 25.5 keV and 1047.8 keV and subsequently simulated using the GEANT4 code. Measurement and simulations are found to be in excellent agreement. A precise characterization, for this type of detector system, of the absolute detection efficiency for such a wide energy range is reported for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing the spatial resolution and gamma discrimination of SiPM-based Anger cameras

SiPM Anger cameras have been designed for use as 2-dimensional thermal neutron detectors for scientific applications such as at single crystal diffraction instruments. These cameras utilize a neutron sensitive scintillator and an array of SiPM photosensors, separated by a light spreading glass. While this optics package is very effective at detecting and positioning neutrons, it is also sensitive to gamma rays, which are a source of unwanted noise. In this work, we underwent a search of scintillator and spreader glass thicknesses to determine the optimal combination for maximizing spatial resolution. Both experimental results and GEANT4 simulations are presented. Further, to address the issue of gamma ray detection, we have also designed and presented a multi-layer scintillator that reduces the amount of scintillation light produced via gamma-ray energy deposition, allowing for easier pulse-height discrimination. A sample of this geometry has been produced that results in a factor of 2 improvement over an equivalent thickness monolithic scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling athermal phonons in novel materials using the G4CMP simulation toolkit

Understanding phonon and charge propagation in superconducting devices plays an important role in both performing low-threshold dark matter searches and limiting correlated errors in superconducting qubits. The Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, models charge and phonon transport within silicon and germanium detectors and has been validated by experimental measurements of phonon caustics, mean charge-carrier drift velocities, and heat pulse propagation times. Here, in this work, we present a concise framework for expanding the capabilities for phonon transport to a number of other novel substrate materials of interest to the dark matter and quantum computing communities, including sapphire (Al 2 O 3 ), gallium arsenide (GaAs), lithium fluoride (LiF), calcium tungstate (CaWO 4 ), and calcium fluoride (CaF 2 ). We demonstrate the use of this framework in generating phonon transport properties of these materials and compare these properties with experimentally-determined values where available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube

The magnetized near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrino–nucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm 3 cubes. The SuperFGD cube unit shows promising optical performance, including a high light yield of about 40 photoelectrons (p.e.) per channel, a low cube-to-cube crosstalk rate below 3%, and a sub-nanosecond time resolution of 0.96 ns. By combining tracking and stopping power measurements of final state particles, this novel detector enables precise 3D-imaging of GeV neutrino interactions with reduced systematic uncertainties. A detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

Neutrino oscillations↗

Absolute efficiency response of the γ-ray spectrometer GRETINA for high-energy γ rays up to 6 MeV

GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array), a state-of-the-art γ-ray tracking spectrometer, has been instrumental in advancing nuclear structure studies, particularly in experiments using fast beams of rare isotopes where the γ rays emitted in flight are subject to large Doppler shifts. This work presents an experimental determination of the γ-ray detection efficiency of GRETINA at energies up to 6 MeV. The high-energy γ rays originated from states that were populated in nucleon-removal reactions from a projectile beam at an intermediate beam energy of about 85 MeV/nucleon. Utilizing γ-γ coincidences, efficiency values were extracted in-beam and translated into a source efficiency at rest employing GEANT4 Monte Carlo simulations. A systematic discrepancy in the efficiency of the forward-positioned detectors was identified which is attributed to specific dead-time effects caused by high-energy light-particle events prevalent at forward angles, generating signals in the Ge crystals that saturate the preamplifier’s first stage. Furthermore, this study provides refined efficiency benchmarks for in-beam experiments, improving the accuracy of quantitative γ-ray spectroscopy analyses with GRETINA and GRETA (Gamma Ray Energy Tracking Array) in the future.

GRETINA↗

Simulation study for particle identification with the dRICH of the ePIC experiment at the EIC

The dual-radiator Imaging Cherenkov detector (dRICH), employing an aerogel and a gas radiator, is a key component of the forward particle identification system for the ePIC experiment at the Electron-Ion Collider (EIC). This study evaluates the dRICH performance using Geant4 simulations in the context of the global ePIC simulation stack, focusing on the optimization of the aerogel radiator and the impact of sensor noise. We compare two aerogel configurations: the initial design (n = 1.019) and the current default (n = 1.026). The latter, characterized by improved optical properties and a higher refractive index, demonstrates enhanced π/K separation at high momenta, effectively extending the operational overlap with the C 2 F 6 gas radiator (n = 1.00076 at 25 °C, as implemented in the simulation software). Additionally, the study investigates the impact of Silicon Photomultiplier (SiPM) dark noise, showing that a 300 kHz noise rate per 3mm x 3mm channel leads to a moderate reduction (approximately 1.5 GeV/c) in the 3σ separation threshold. These results validate the current dRICH design and quantify the purity levels achievable for both radiators under expected experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗