Impedance Measurement of Inverter-Coupled Generation Using a Multimegawatt Grid Simulator
This presentation provides an overview of interver-coupled generation using a multimegawatt grid simulator.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This presentation provides an overview of interver-coupled generation using a multimegawatt grid simulator.
Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.
Abstract Here we provide an update to global gridded annual and monthly crop datasets. This new dataset uses the crop categories established by the Global Agro-Ecological Zones (GAEZ) Version 3 model, which is based on the Food and Agricultural Organization of the United Nations (FAO) crop production data. We used publicly available data from the FAOSTAT database as well as GAEZ Version 4 global gridded dataset to generate circa 2015 annual crop harvested area, production, and yields by crop production system (irrigated and rainfed) for 26 crops and crop categories globally at 5-minute resolution. We additionally used available data on crop rotations, cropping intensity, and planting and harvest dates to generate monthly gridded cropland data for physical areas for the 26 crops by production system. These data are in standard georeferenced gridded format, and can be used by any global hydrology, land surface, or other earth system model that requires gridded annual or monthly crop data inputs.
(DG)2 is an impact analysis tool for electrical utilities to perform spatio-temporal analysis with solar and battery energy storage systems. The purpose of the tool is to help distribution utilities with identifying impacts and costs associated with locating a MW-scale solar farm and energy storage system at a certain location over other choices. This tool also assists utilities to assess the amount of reverse power flow at the transmission lines.
The objective of this technical memo is to describe the different methods that have been implemented and tested regarding the use of the MGRIT algorithm for generator and load ramping problems.
Abstract not provided.
The Center for Alternative Synchronization and Timing (CAST) views Precision Time Protocol (PTP) and Network Time Protocol (NTP) as critical elements of the grid, from generation to the grid edge. This tech bulletin discusses the operation of NTP. The document shows not only commercial but also open-source applications. In some cases, the commercial applications may already have existing feature sets to secure and monitor NTP streams. From a security standpoint, using subscription NTP is risky unless the open bidirectional ports on local firewalls and routers are properly monitored and controlled.
Explore the source record for details and available documents.
Visualization of hourly generation, load, unserved load, and locational marginal energy prices in the western United States during a July 22-28 heatwave event in 2018. In addition to hourly time series data of each of the parameters, choropleth maps showing the hourly value for each balancing authority are provided as well as a county-level choropleth map of temperature.
Explore the source record for details and available documents.
Abstract not provided.
Here, the accuracy and computational cost of a large eddy simulation are highly dependent on the computational grid. Building optimal grids manually from a priori knowledge is not feasible in most practical use cases; instead, solution-adaptive strategies can provide a robust and cost-efficient method to generate a grid with the desired accuracy. We adapt the residual estimation algorithm developed by Toosi and Larsson for Discontinuous Galerkin Spectral Elements Methods (DGSEM) to guide the grid-adaptation process. The core of the method is the computation of the estimated modeling residual using the polynomial basis functions used in DGSEM, and the averaging of the estimated residual over each element. The final method is assessed in multiple channel flow test cases and for the transonic flow over an airfoil, in both cases making use of mortar interfaces between elements with hanging nodes. The method is found to be robust and reliable, and to provide solutions on grids with significantly fewer elements at comparable accuracy compared to when using human-generated grids.
With photovoltaic (PV) generation substantially increases, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV generation. On the one hand, the increase of PV generation necessitates the needs of more flexible resources. On the other hand, PV generation, because of its low operation cost, has been replacing the conventional generation in the system which is the main flexible resources in the current system. Consequently, there is a trend to require the renewable generation including PV to provide flexible ancillary services to further accommodate more PV integration. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. It shows that not only the system reliability but also PV's profitability can be improved with PV providing more ancillary services.
Inverter-based storages are poised to play a prominent role in future power grid with massive renewable generation. Grid-forming inverters (GFMs) are emerging as a dominant technology with synchronous generators (SG)-like characteristics through primary control loops. Advanced secondary-layer control schemes, e.g., consensus algorithms, allow GFM-interfaced storage units to participate in frequency regulations and restore nominal frequency following grid disturbances. However, it is imperative to ensure critical frequency safety limits are not violated while the grid transitions from pre- to post-disturbance operating point. This paper presents a novel safety-enforced consensus method, having three distinct objectives: safe transient frequency evolution, minimizing frequency deviation, and coordinated power sharing. The proposed technique is illustrated using a GFM-interfaced grid-wide storage network on the IEEE 68-bus system under multiple grid transient scenarios.
A simplified model of a redundant power grid is used to study integration of fluctuating renewable generation. The grid consists of large number of generator and consumer nodes. The net power consumption is determined by the difference between the gross consumption and the level of renewable generation. The gross consumption is drawn from a narrow distribution representing the predictability of aggregated loads, and we consider two different distributions representing wind and solar resources. Each generator is connected to D consumers, and redundancy is built in by connecting R {le} D of these consumers to other generators. The lines are switchable so that at any instance each consumer is connected to a single generator. We explore the capacity of the renewable generation by determining the level of 'firm' generation capacity that can be displaced for different levels of redundancy R. We also develop message-passing control algorithm for finding switch sellings where no generator is overloaded.
Abstract not provided.
This paper discusses the modeling, analysis, and testing in a real-time simulation environment of the Lanai power grid system for the integration and control of PhotoVoltaic (PV) distributed generation. The Lanai Island in Hawaii is part of the Hawaii Clean Energy Initiative (HCEI) to transition to 30% renewable green energy penetration by 2030. In Lanai the primary loads come from two Castle and Cook Resorts, in addition to residential needs. The total peak load profile is 12470 V, 5.5 MW. Currently there are several diesel generators that meet these loading requirements. As part of the HCEI, Lanai has initially installed 1.2 MW of PV generation. The goal of this study has been to evaluate the impact of the PV with respect to the conventional carbon-based diesel generation in real time simulation. For intermittent PV distributed generation, the overall stability and transient responses are investigated. A simple Lanai 'like' model has been developed in the Matlab/Simulink environment (see Fig. 1) and to accommodate real-time simulation of the hybrid power grid system the Opal-RT Technologies RT-Lab environment is used. The diesel generators have been modelled using the SimPowerSystems toolbox swing equations and a custom Simulink module has been developed for the High level PV generation. All of the loads have been characterized primarily as distribution lines with series resistive load banks with one VAR load bank. Three-phase faults are implemented for each bus. Both conventional and advanced control architectures will be used to evaluate the integration of the PV onto the current power grid system. The baseline numerical results include the stable performance of the power grid during varying cloud cover (PV generation ramping up/down) scenarios. The importance of assessing the real-time scenario is included.
Sensor anomalies in power grids can have significant impacts on the operation of the grid due to the increased reliance of the grid operation on data-driven applications. However, there is a lack of datasets that accurately capture these anomalies as many of the anomalies go undetected using the current bad data detectors. High-fidelity labeled datasets are essential for developing robust applications that can detect and mitigate the impacts of anomalies. In this paper, we propose a hardware-in-the-loop testbed model that can emulate the grid behavior with high-fidelity. This testbed is used to inject anomalies at various levels in the grid architecture and generate labeled datasets. These high-fidelity datasets can be used for development and validation of data-driven applications for detection and mitigation of anomalies in grids and other cyber-physical systems.