Search NASA⌕ Search

SEARCH · Search NASA

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Standards and Guidelines for the Design of Trunnions of RAM Transport Packages - 17365

Trunnion systems of packages for the transport of radioactive materials have to guarantee the safe handling of package during crane operations (lifting, tilting) and to secure package tie down to the transport vehicle, if the trunnions are used as attachment points during transport. The design of trunnions is based on IAEA Regulations SSR-6, the supporting Advisory Material SSG-26 and further appropriate technical standards and/or guidelines. For package approval procedures in Germany the guideline BAM-GGR 012 has to be applied. If a package is handled inside a german nuclear power plant, the standard KTA 3905 has to be fulfilled additionally. In this paper the requirements of KTA 3905 [4] concerning the trunnion systems as load attaching points (LAP) are discussed in connection with the recommendations in the guideline BAM-GGR 012 [3]. This guideline is prepared at BAM Federal Institute for Materials Research and Testing for analysis and assessment of bolted lid and trunnion systems of Type B(U) transport packages. The quality assurance questions concerning trunnion systems are discussed as well. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review Guidelines for Biosphere Safety Assessment of Low-Level Waste Disposal Repository in Taiwan - 19606

Conducting reviews of radiological dose assessments is a crucial step toward the approval of long-term radiological safety requirements for low-level radioactive waste (LLW) disposal facilities. However, the concentration of radionuclides released from the near field into the biosphere and the radiation exposure levels to an individual can influence the performance acceptability of the LLW disposal facility and safety of the disposal environment. Therefore, all LLW must be managed and disposed of such that it minimizes risk to individuals and the environment. A dose of 0.25 mSv/year is the limit for individuals expected to receive the highest level of exposure to residual radioactivity. In Taiwan, a review for license applications has been proposed for LLW disposal facilities. These review guidelines are based on the Standard Review Plan (NUREG-1200) and are amended according to the environmental conditions in Taiwan. These guidelines can help reviewers to perform safety assessment reviews of applications for the construction and operation of LLW disposal facilities. The review guidelines for biosphere safety assessment include radiological dose assessment, description of waste characteristics, radionuclide transport characteristics, radiation dose under normal and unusual conditions, radionuclide release into the biosphere, and interpretation of evaluation results in various transfer mechanisms. These guidelines can also serve as references for regulatory departments conducting safety assessments of radiological doses in LLW disposal facilities in Taiwan. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Considerations for Resilience Guidelines for Clean Energy Plans: For the Oregon Public Utility Commission and Oregon Electricity Stakeholders

This document summarizes relevant approaches, research, models, and national examples for state utility regulators tasked with developing utility guidelines for risk-based resiliency planning. In 2021, the Oregon Legislature enacted a 100 percent clean electricity by 2040 standard that requires the Oregon Public Utility Commission (PUC) to oversee utility planning for aggressive clean energy deployment through Clean Energy Plans (House Bill 2021, Sec. 4). In addition to meeting emissions reductions targets, Clean Energy Plans must also: "Include a risk-based examination of resiliency opportunities that includes costs, consequences, outcomes, and benefits based on reasonable and prudent industry resiliency standards and guidelines established by the Public Utility Commission." This report will support the Oregon Public Utility Commission in developing resilience guidelines. Other state public utility commissions may also benefit from this research.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Guidelines and Suggestions for Balloon Gondola Design

This paper discusses the current gondola design requirements for the Columbia Scientific Balloon Facility (CSBF). The CSBF is responsible for launching and supporting balloon borne scientific instruments and has some current updated guidelines that will be discussed in this presentation. As the sophistication of Payload systems have increased in size and complexity new guidelines have been implemented in order to make these instruments stay within the acceptable launch risks. Additionally, there is a requirement to submit a proper stress analysis report that states the flight design requirements have been met. Suggestions are discussed in this presentation that establish the proper guidelines to submit these.

Guidelines for Balloon Gondola Design↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Experts' perspective on the performance of Chinese technical guidelines for Plan Environmental Impact Assessment

This research was to evaluate the Technical Guideline (HJ/T130-2003) effectiveness based on data resource from a questionnaire survey and interviews on EIA experts. The result demonstrated that the guideline served mainly as a quality control measure for PEIA products, and only a small proportion of experts considered it effective due to its inconsistency with the newly released Chinese PEIA Regulation (2009) and poor practicability. Current status of SEA implementation in China was also studied in terms of application fields, effectiveness evaluation, and major issues to affect SEA, to conclude that SEA implementation in China is premature, and with limited effectiveness. The major problem was the lack of effective methodologies and technical tools. Recommendations for revising the PEIA Guideline and advices to improving SEA implementation in China were accordingly proposed.

54 ENVIRONMENTAL SCIENCES↗

Factors Associated With Guideline-Concordant Use of Radiotherapy After Mastectomy in the National Comprehensive Cancer Network

Purpose: We examined the rates and determinants of appropriate and inappropriate use of postmastectomy radiotherapy (PMRT), as defined by the National Comprehensive Cancer Network (NCCN) practice guidelines, among women with Stage I-II breast cancer (American Joint Committee on Cancer, 5th edition). Methods and Materials: Using clinical characteristics, 1,620 consecutive patients at eight NCCN institutions who had undergone mastectomy between July 1997 and June 2002 were classified into three cohorts according to whether the guidelines (1) recommended PMRT, (2) recommended against PMRT, or (3) made no definitive PMRT recommendation. We defined the absence of PMRT in the first cohort as underuse and receipt of PMRT in the second cohort as overuse. Multivariate logistic regression analysis was applied to investigate the association of clinical and sociodemographic factors with PMRT. Results: Overall, 23.8% of patients received PMRT. This included 199 (83.6%) of 238 in the 'recommend PMRT' cohort, 58 (5.6%) of 1,029 in the 'recommend against PMRT' cohort, and 127 (38.6%) of 329 in the 'consider PMRT' cohort. The only factor associated with underuse in the 'recommend PMRT' cohort was nonreceipt of chemotherapy (odds ratio [OR], 0.08; p <0.0001). In addition to tumor characteristics, the factors associated with overuse in the 'recommend against PMRT' cohort included age <50 years (OR, 2.28; p = 0.048), NCCN institution (OR, 1.04-8.29; p = 0.026), higher education (OR, 3.49; p = 0.001), and no reconstructive surgery (OR, 2.44; p = 0.019). The factors associated with PMRT in the 'consider PMRT' cohort included NCCN institution (OR, 1.1-9.01; p <0.0001), age <50 years (OR, 2.26; p = 0.041), and tumor characteristics. Conclusion: The results of our study have shown that concordance with definitive treatment guidelines was high. However, when current evidence does not support a definitive recommendation for PMRT, treatment decisions appear to be influenced, not only by patient age and clinical characteristics, but also by institution-specific patterns of care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Selective Nodal Irradiation for Head and Neck Cancer Using Intensity-Modulated Radiotherapy: Application of RTOG Consensus Guidelines in Routine Clinical Practice

Purpose: We have been using intensity-modulated radiotherapy (IMRT) for selective neck irradiation. This article presents an analysis of patterns of failure and their dosimetric correlation. Methods and Materials: Between October 2003 and January 2008, 83 patients with head-and-neck cancer were treated with IMRT. Nodal levels were contoured as per the Radiation Therapy Oncology Group (RTOG) consensus guidelines. Results: There were 32 relapses with 23 local relapses (21 local relapses alone and 2 local and regional relapses, simultaneously), 9 regional relapses (including 2 simultaneous local and regional relapses), and 5 distant relapses, of which 2 patients had local relapses. At 2 and 3 years, the locoregional relapse-free survival rates were was 68.3% and 60.8%, respectively, while the overall survival rates were 84.1% and 81.7%, respectively. Subgroup analyses revealed significant differences in locoregional relapse-free survival rates for total treatment times of <53 days vs. >53 days, a volume of CTV1PTV (i.e., the volume prescribed 70 Gy) <177 cc vs. >177 cc, a V100 for CTV1PTV of <91% vs. >91%, and a minimum dose to CTV1PTV of <54 Gy vs. >54 Gy. There were no failures in the elective nodal volume, substantiating both the nodal selection criteria and the RTOG consensus guidelines for delineation of neck node levels. Conclusions: IMRT for head-neck cancer is feasible, using elective nodal selection criteria along with RTOG consensus guidelines for the radiological boundaries of levels of neck nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

American Society for Radiation Oncology (ASTRO) and American College of Radiology (ACR) Practice Guideline for the Transperineal Permanent Brachytherapy of Prostate Cancer

Transperineal permanent prostate brachytherapy is a safe and efficacious treatment option for patients with organ-confined prostate cancer. Careful adherence to established brachytherapy standards has been shown to improve the likelihood of procedural success and reduce the incidence of treatment-related morbidity. A collaborative effort of the American College of Radiology (ACR) and American Society for Therapeutic Radiation Oncology (ASTRO) has produced a practice guideline for permanent prostate brachytherapy. The guideline defines the qualifications and responsibilities of all the involved personnel, including the radiation oncologist, physicist and dosimetrist. Factors with respect to patient selection and appropriate use of supplemental treatment modalities such as external beam radiation and androgen suppression therapy are discussed. Logistics with respect to the brachtherapy implant procedure, the importance of dosimetric parameters, and attention to radiation safety procedures and documentation are presented. Adherence to these practice guidelines can be part of ensuring quality and safety in a successful prostate brachytherapy program.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

American Society for Radiation Oncology (ASTRO) and American College of Radiology (ACR) Practice Guideline for the Performance of High-Dose-Rate Brachytherapy

High-Dose-Rate (HDR) brachytherapy is a safe and efficacious treatment option for patients with a variety of different malignancies. Careful adherence to established standards has been shown to improve the likelihood of procedural success and reduce the incidence of treatment-related morbidity. A collaborative effort of the American College of Radiology (ACR) and American Society for Therapeutic Radiation Oncology (ASTRO) has produced a practice guideline for HDR brachytherapy. The guideline defines the qualifications and responsibilities of all the involved personnel, including the radiation oncologist, physicist and dosimetrists. Review of the leading indications for HDR brachytherapy in the management of gynecologic, thoracic, gastrointestinal, breast, urologic, head and neck, and soft tissue tumors is presented. Logistics with respect to the brachytherapy implant procedures and attention to radiation safety procedures and documentation are presented. Adherence to these practice guidelines can be part of ensuring quality and safety in a successful HDR brachytherapy program.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure to Adhere to Protocol Specified Radiation Therapy Guidelines Was Associated With Decreased Survival in RTOG 9704-A Phase III Trial of Adjuvant Chemotherapy and Chemoradiotherapy for Patients With Resected Adenocarcinoma of the Pancreas

Purpose: In Radiation Therapy Oncology Group 9704, as previously published, patients with resected pancreatic adenocarcinoma received continuous infusion 5-FU and concurrent radiotherapy (5FU-RT). 5FU-RT treatment was preceded and followed by randomly assigned chemotherapy, either 5-FU or gemcitabine. This analysis explored whether failure to adhere to specified RT guidelines influenced survival and/or toxicity. Methods and Materials: RT requirements were protocol specified. Adherence was scored as per protocol (PP) or less than per protocol (<PP). Scoring occurred after therapy but before trial analysis and without knowledge of individual patient treatment outcomes. Scoring was done for all tumor locations and for the subset of pancreatic head location. Results: RT was scored for 416 patients: 216 PP and 200 <PP. For all pancreatic sites (head, body/tail) median survival (MS) for PP vs. <PP was 1.74 vs. 1.46 years (log-rank p = 0.0077). In multivariate analysis, PP vs. <PP score correlated more strongly with MS than assigned treatment arm (p = 0.014, p = NS, respectively); for patients with pancreatic head tumors, both PP score and gemcitabine treatment correlated with improved MS (p = 0.016, p = 0.043, respectively). For all tumor locations, PP score was associated with decreased risk of failure (p = 0.016) and, for gemcitabine patients, a trend toward reduced Grade 4/5 nonhematologic toxicity (p = 0.065). Conclusions: This is the first Phase III, multicenter, adjuvant protocol for pancreatic adenocarcinoma to evaluate the impact of adherence to specified RT protocol guidelines on protocol outcomes. Failure to adhere to specified RT guidelines was associated with reduced survival and, for patients receiving gemcitabine, trend toward increased nonhematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Delineation of the Postprostatectomy Prostate Bed Using Computed Tomography: Interobserver Variability Following the EORTC Delineation Guidelines

Purpose: The present study aims to assess the interobserver agreement of prostate bed delineation after radical prostatectomy using CT alone as proposed by the European Organization for Research and Treatment of Cancer (EORTC) guidelines. Methods and Materials: Six observers delineated the postoperative prostate bed (PB) and the original seminal vesicle position or remnants (SV) of 10 patients according to the EORTC guidelines. Contours were then compared for agreement between observers (the apparent volume overlap and generalized kappa statistics). Standard deviations were also calculated to measure the variability of the position of the outer margins. Results: The mean volume of 100% agreement ({+-}1 standard deviation, SD) was only 5.0 ({+-}3.3) ml for the PB and 0.9 ({+-}1.5) ml for the SV, whereas the mean union of all contours ({+-}1 SD) was 41.1 ({+-}11.8) ml and 25.3 ({+-}13.4) ml, respectively. The mean overall agreement corrected for chance was moderate for both the PB (mean kappa, 0.49; range, 0.35-0.62) and SV (mean kappa, 0.42; range, 0.22-0.59). The overall SD of the outer margins of the PB ranged from 4.6 to 7.0 mm Conclusion: The delineation of the postprostatectomy bed using CT shows only a moderate observer agreement when following the EORTC guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

One Decade Later: Trends and Disparities in the Application of Post-Mastectomy Radiotherapy Since the Release of the American Society of Clinical Oncology Clinical Practice Guidelines

Purpose: In 2001 ASCO published practice guidelines for post mastectomy radiotherapy (PMRT). We analyzed factors that influence the receipt of radiotherapy therapy and trends over time. Methods and Materials: We analyzed 8889 women who underwent mastectomy as primary surgical treatment for stage II or III breast cancer between 1995 and 2008 using data from the Kentucky Cancer Registry. We categorized patients according to ASCO group: group 1, PMRT not routinely recommended (T2, N0); group 2, PMRT controversial/evidence insufficient (T1-2, N1); group 3, PMRT recommended or suggested (T3-4 or N2-3). Probability of receiving PMRT was assessed using logistic regression. Results: Overall, 24.0% of women received PMRT over the study period. The rates of PMRT for group 1, 2, and 3 were 7.5%, 19.5%, and 47.3%, respectively. Since 2001, there was an increase in the use of PMRT (from 21.1%-26.5%, P<.0001), which occurred mainly among group 3 members (from 40.8%-51.2%, P<.0001). The average rate remained constant in group 1 (from 7.1%-7.4%, P=.266) and decreased in group 2 (from 20.0%-18.1%, P<.0001). On multivariate analysis, the rate of PMRT was significantly lower for women aged >70 years (vs. younger), rural Appalachia (vs. non-Appalachia) populations, and Medicaid (vs. privately insured) patients. Conclusions: ASCO guidelines have influenced practice in an underserved state; however PMRT remains underused, even for highest-risk patients. Barriers exist for elderly, rural and poor patients, which independently predict for lack of adequate care. Updated guidelines are needed to clarify the use of PMRT for patients with T1-2, N1 disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic Radiosurgery

Purpose: Spinal stereotactic radiosurgery (SRS) is increasingly used to manage spinal metastases. However, target volume definition varies considerably and no consensus target volume guidelines exist. This study proposes consensus target volume definitions using common scenarios in metastatic spine radiosurgery. Methods and Materials: Seven radiation oncologists and 3 neurological surgeons with spinal radiosurgery expertise independently contoured target and critical normal structures for 10 cases representing common scenarios in metastatic spine radiosurgery. Each set of volumes was imported into the Computational Environment for Radiotherapy Research. Quantitative analysis was performed using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE) with kappa statistics calculating agreement between physicians. Optimized confidence level consensus contours were identified using histogram agreement analysis and characterized to create target volume definition guidelines. Results: Mean STAPLE agreement sensitivity and specificity was 0.76 (range, 0.67-0.84) and 0.97 (range, 0.94-0.99), respectively, for gross tumor volume (GTV) and 0.79 (range, 0.66-0.91) and 0.96 (range, 0.92-0.98), respectively, for clinical target volume (CTV). Mean kappa agreement was 0.65 (range, 0.54-0.79) for GTV and 0.64 (range, 0.54-0.82) for CTV (P<.01 for GTV and CTV in all cases). STAPLE histogram agreement analysis identified optimal consensus contours (80% confidence limit). Consensus recommendations include that the CTV should include abnormal marrow signal suspicious for microscopic invasion and an adjacent normal bony expansion to account for subclinical tumor spread in the marrow space. No epidural CTV expansion is recommended without epidural disease, and circumferential CTVs encircling the cord should be used only when the vertebral body, bilateral pedicles/lamina, and spinous process are all involved or there is extensive metastatic disease along the circumference of the epidural space. Conclusions: This report provides consensus guidelines for target volume definition for spinal metastases receiving upfront SRS in common clinical situations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Are Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm Applicable to Other Malignancies—Assessment of Nodal Distribution in Gynecological Malignancies

Purpose: Intensity modulated radiation therapy is used to reduce dose to adjacent critical structures while maintaining adequate target coverage, but it requires precise target localization. We report the 3-dimensional distribution of para-aortic (PA) lymph nodes (LN) in pelvic malignancies. We propose a guideline to accurately define the PA LN by anatomic landmarks and compare our data with published guidelines for pancreatic cancer. Methods and Materials: A retrospective analysis was performed on 46 patients with pelvic malignancies and positive PA LNs. Positive LNs were defined based on size and morphology or fluorodeoxyglucose avidity. All PA LNs were characterized into 3 groups based on location: left PA (between aorta and left psoas muscle), aortocaval (between aorta and inferior vena cava), and right paracaval (between inferior vena cava and right psoas muscle). Patients with retrocrural LNs were also analyzed. Results: One hundred thirty-three positive PA LNs were evaluated. The majority of the PA LNs were in the left PA (59%) and aortocaval (35) regions, and only 8% were in the right paracaval region. All patients with positive right paracaval LNs also had involved left PA LNs, with only 1 exception. The highest PA LN involvement was at the level of the renal vessels and was seen in 28% of patients. Of these patients with disease extending to renal vessels, 38% had retrocrural LN involvement. Conclusions: The nodal contouring for the PA region should not be defined by a fixed circumferential margin around the vessels. The left PA and aortocaval spaces should be covered adequately because these are common locations of PA LNs. For microscopic disease superiorly, contouring should extend up to renal vessels rather than a fixed bony landmark. For patients who have nodal involvement at renal vessels, one can consider including retrocrural LNs. Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm are not applicable to gynecological malignancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modern Radiation Therapy for Primary Cutaneous Lymphomas: Field and Dose Guidelines From the International Lymphoma Radiation Oncology Group

Primary cutaneous lymphomas are a heterogeneous group of diseases. They often remain localized, and they generally have a more indolent course and a better prognosis than lymphomas in other locations. They are highly radiosensitive, and radiation therapy is an important part of the treatment, either as the sole treatment or as part of a multimodality approach. Radiation therapy of primary cutaneous lymphomas requires the use of special techniques that form the focus of these guidelines. The International Lymphoma Radiation Oncology Group has developed these guidelines after multinational meetings and analysis of available evidence. The guidelines represent an agreed consensus view of the International Lymphoma Radiation Oncology Group steering committee on the use of radiation therapy in primary cutaneous lymphomas in the modern era.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GUIDELINES FOR THE DESIGN, FABRICATION, TESTING, INSTALLATION AND OPERATION OF SRF CAVITIES

Superconducting Radio-Frequency (SRF) cavities containing cryogens under pressure pose a potential rupture hazard to equipment and personnel. Generally, pressure vessels fall within the scope of the ASME Boiler and Pressure Vessel Code however, the use of niobium as a material for the SRF cavities is beyond the applicability of the Code. Fermilab developed a guideline to ensure sound engineering practices governing the design, fabrication, testing, installation and operation of SRF cavities. The objective of the guideline is to reduce hazards and to achieve an equivalent level of safety afforded by the ASME Code. The guideline addresses concerns specific to SRF cavities in the areas of materials, design and analysis, welding and brazing, pressure relieving requirements, pressure testing and quality control.

42 ENGINEERING↗

Guideline 36 Conformance Test v2.0

ASHRAE Guideline 36 provides guidance for how typical commercial building HVAC systems should be controlled to reduce energy costs and improve the indoor environmental quality for occupants. An industry-led effort is developing test scripts for how control manufacturers can test that the control logic in their control products follows Guideline 36. This software intends to support that effort in two ways. First, by providing a testbed for control manufacturers to run the test scripts against their own control products and compare their generated results to the expected results provided by the test scripts. Second, by providing a testbed that can be used during the development of test scripts to rapidly and repeatably verify they exercise Guideline 36 logic as desired and generate accurate expected results that control products can be compared to. An initial version of the software has already been developed and released open-source by a previous CEC-funded project that implemented the first use case (https://github.com/LBNL-ETA/guideline36_conformance_test/blob/master/LICENSE.txt), while this software disclosure will add the functionality of the second use case, as well as update the software where needed, all open-source. We intend to extend and contribute to the existing open-source software repository.

Blum, David [Lawrence Berkeley National Laboratory↗